Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 26 January 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 22 calendar years (1999–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA4208
489246
Flag
UNITED STATES
Maury page id
psix-489246

Documentation record

Registered dimensions (L × B × D)254.9 ft × 78.0 ft × 14.5 ft
Registered tonnagegross 3,021 / net 906
ITC dimensions (L × B × D)254.9 ft × 78.0 ft × 14.5 ft
ITC tonnagegross 3,021 / net 906
BuilderNEWPARK SHIPBUILDING & REPAIR · HOUSTON, TX, UNITED STATES · built 1997
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3021 - Convention (Subpart B), Gross Ton
906 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 36 inspections, each with its date, unit and type; 33 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ORION Towing Vessel · MISLE 150757 · 14 February 2008 · activity 3148192TITAN Towing Vessel · MISLE 148292 · 22 June 1999 · activity 118175

Inspection history · 36

26 January 2026 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8299460
13 December 2024 Periodic Inspection · MARPOL Annex I Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8036920
30 October 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7815045
22 August 2023 Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7774158
7 December 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7605772
18 October 2021 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7327947
29 July 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7270490
19 February 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7142949
19 May 2020 Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6956097
7 April 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6937522
12 November 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6856020
22 May 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6690869
25 October 2018 Administrative Inspection · Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6563923
20 February 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6357671
20 January 2017 In-Service Inspection · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6069574
6 January 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5784613
14 May 2014 Drydock Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4858858
8 April 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4829563
23 January 2014 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4786790
10 November 2011 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4213363
7 December 2010 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3906453
24 September 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3598843
2 June 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3478018
11 February 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3416619
14 February 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3148192
10 October 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3068547
3 November 2006 Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2807416
20 January 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2570089
3 March 2005 Annual Inspection · Administrative Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2302817
6 January 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2270059
21 September 2004 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2201038
8 December 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1958338
16 April 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1775009
19 March 2003 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1755339
14 February 2000 Initial Certification · Hull Examination · MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1479389
22 June 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 118175

Deficiency record · 33

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 January 2026 Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 90.35 of this subchapter, will be considered as satisfactory evidence of the structural efficiency of the vessel. Two fractured welds found which require grind/reweld; 1C third truss frame from the access ladder, 1SI third truss frame from access ladder. 46 CFR 92.01-10
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 February 2026
Resolution: Accepted photo of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 December 2024 Resolved
Each inflatable lifesaving appliance and marine evacuation system must be serviced—Within 12 months of each subsequent servicing, except when servicing is delayed until the next scheduled inspection of the vessel, provided the delay does not exceed 5 months. Vessel's inflatable life raft was found to be overdue for inspection. Vessel's route is restricted to Lakes, Bays, and Sounds. 46 CFR 199.190 (g)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2024
Resolved 13 December 2024
Resolution: Received picture and servicing certificate evidence of a valid inflatable life raft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 October 2023 Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15 percent. Barge was unable to test overspeed during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2023
Resolved 21 November 2023
Resolution: Witnessed satisfactory test.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 22 August 2023 Resolved
In the inspection of hulls, the standards established by ABS shall be accepted as standard by the inspectors. Aft ladder on main deck leading up to winch house is holed at the 90 degree turn where the ladder support is welded to the house.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2023
Resolved 2 October 2023
Resolution: Accepted photo for repair to ladder.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 October 2021 Resolved
Each inflatable life raft must be approved under series 160.151 and be equipped with a SOLAS A pack. Vessels inflatable life raft servicing certificate is overdue. To the satisfaction of the attending USCG Marine Inspector, show proof of a valid certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2021
Resolved 2 November 2021
Resolution: Received inflatable life raft servicing report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2021 Resolved
Each lifebuoy must be marked in block capital leters with the name of the vessel and the name of the port. All life-rings on deck were found to be missing the vessels name and homeport.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2021
Resolved 5 April 2021
Resolution: All life-rings have been labeled with the vessels name and homeport.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2021 Resolved
Lifebuoys with attached self-igniting lights must be equally distributed. The float light attached to the bow ring-buoy was found to be inoperable. 46 CFR 199.70(a)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2021
Resolved 5 April 2021
Resolution: Repiar conducted and the bow ring-buoy float light is now operational.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 February 2021 Resolved
Where fitted emergency lighting and power systems are operated and inspected at least once in each week that the vessel is navigated to be assured that the system is in proper operating condition. Emergency lighting within the electrical room was to be inoperable. 46 CFR 97.15-30(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2021
Resolved 5 April 2021
Resolution: Emergency lighting within the electrical room has been repaired and is now operatonal.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 19 February 2021 Resolved
It shall be the duty of the master and chief engineer to see that the vessel is in a clean and sanitary condition. The Marine Sanitation Device was found to be leaking. 46 CFR 97.15-10(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2021
Resolved 5 April 2021
Resolution: Deteriorated hose connnected to the Marine Sanitation Device has been replaced, leak resolved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 February 2021 Resolved
It shall be the duty of the owner, master, or person in charge to see tht the vessel's firefighting equipment is at all times ready for use. A portable fire extinguisher on the deck was found to have a damaged pressure gauge. 46 CFR 97.15-60(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 February 2021
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 February 2021 Resolved
It shall be the duty of the owner, master, or person in charge to see tht the vessel's firefighting equipment is at all times ready for use. A portable fire extinguisher in vicinity of the marine sanitation device was found to be installed within an improperly sized (too large) bracket. 46 CFR 97.15-60(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2021
Resolved 5 April 2021
Resolution: A properly sized portable fire extinguisher bracket has been installed.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 21 February 2018 Resolved
Provide documentation of annual review of SOPEP.
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 26 February 2018
Resolution: The barge submitted documentation proving the annual reviewal of the SOPEP.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 February 2018 Resolved
Replace missing port navigation light.
Action required: 705 - Other - as specified
Resolved 26 February 2018
Resolution: The barge replaced the nav light.
Lifesaving › Lifebuoys › Serviceable
Issued 21 February 2018 Resolved
Repair 5 life rings as needed: grablines, light batteries, light clip, SOLAS tape, restencil name and homeport.
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 26 February 2018
Resolution: All life rings were repaired as needed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2016 Resolved
Complete a satisfactory annual inspection prior to operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2016
Resolved 20 January 2016
Resolution: Inspected completed satisfactorily; endorsed COI for annual inspection.
Documentation › Certificates/Documents › Construction and Equipment Certificate (DSC)
Issued 6 January 2016 Resolved
Prove annual servicing for fuel hose.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2016
Resolved 20 January 2016
Resolution: Servicing certificate provided.
Lifesaving › Inflatable Liferafts › Servicing
Issued 6 January 2016 Resolved
Ensure liferaft is serviced
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2016
Resolved 20 January 2016
Resolution: Servicing certificate provided.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 6 January 2016 Resolved
Prove Aux Gen overspeed
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2016
Resolved 20 January 2016
Resolution: Engine properly shutdown when subjected to overspeed trip test.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 6 January 2016 Resolved
Prove main gen low lube oil pressure
Condition: Invalid
Due 20 January 2016
Resolved 20 January 2016
Resolution: Engine properly shutdown when subjected to low lube oil pressure trip test.
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 6 January 2016 Resolved
Reconfigure crankcase breather hose in accordance with manufacturer specification.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 January 2016
Resolved 20 January 2016
Resolution: Breather hoses properly connected.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 January 2016 Resolved
Replace reflective tape and grab lines on 02 life rings. Waterlight tether too short.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2016
Resolved 20 January 2016
Resolution: rEFLECTIVE TAPE AND GRAB LINES REPLACED
Electrical › Electric Supply System (service) › Cable
Issued 7 December 2010 Resolved
Provide single line drawing of system to MSC for approval.
Action required: 705 - Other - as specified
Due 1 June 2011
Resolved 13 December 2011
Resolution: Received emailed letter from MSC (serial # E2-1104624). Scanned into MISLE case.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 February 2009 Resolved
ISSUED REQMT IN ERROR. Vessel does not need to comply w/either MTSA or ISPS. No change to Route needed, or made.
Due 11 February 2009
Resolved 12 February 2009
Resolution: ISSUED REQMT IN ERROR. Vessel does not need to comply w/either MTSA or ISPS. No change to Route needed, or made.
Lifesaving › Launching Appliances › Release Mechanism
Issued 11 February 2009 Resolved
Missing HRU or other float-free arrangement for liferaft.
Due 11 February 2009
Resolved 11 February 2009
Resolution: Corrected during inspection.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 11 February 2009 Resolved
SOPEP is out-of-date regarding phone numbers for local CG.
Due 11 February 2009
Resolved 11 February 2009
Resolution: Pen & ink changes made on the spot, POC requested update version from company.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 February 2009 Resolved
No NTVRP available on board
Due 11 February 2009
Resolved 11 February 2009
Resolution: NTVRP sent from company.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 10 October 2007 Resolved
Repair portable deck generator power supply cable vessel plug. The vessel plug from the generator becomes hot when the generator is operated. The generator may not be operated until the cable and/or plug connection is repaired.
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 10 October 2007
Resolution: Generator to vessel plug disassembled for repair while on board.
Construction/Loadline › Hull › Hull Plating
Issued 3 November 2006 Resolved
Per ABS requirements, conduct the following repairs: Install inserts in the following voids: 1P/Inboard - bottow plate IWO spud well; 2P/Outboard - deck & side shell; 3S/Outboard - bottom plate; 4C - deck plate; 5C - deck plate; 5P/Outboard - deck & side shell; 7S - bottom plate; 7S/Inboard - bottom plate. All inserts to be examined by vacuum box.
Action required: 705 - Other - as specified
Resolved 13 November 2006
Resolution: Repairs completed & cleared by ABS surveyor.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 March 2005 Resolved
90+ days late for annual inspection. Conduct annual inspection prior to operating beyond the boundary line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 31 March 2005
Resolution: Conducted satisfactory annual inspection.
Lifesaving › Lifejacket/PFD (General)
Issued 19 March 2003 Resolved
Provide 6 Type I lifejackets (with approval # 160.155, 160.176, 160.177) in adult sizes. Jackets need to be fitted with retro tape & be fitted with life jacket lights. Ref: 46 CFR 199.70 (b) & each jacket must be marked with the vessel's name. May not carry any crew underway until cleared. LEGACY COMPONENT DESC: Quantity
Due 19 April 2003
Resolved 16 April 2003
Resolution: Type I Lifejackets were on board and properly marked.
Documentation › Certificates/Documents
Issued 19 March 2003 Resolved
Provide FCC Radiotelegraphy Safety Certificate for the installation on board. LEGACY COMPONENT DESC: FCC RADIOTELEGRAPHY SAFETY CERT.
Due 19 April 2003
Resolved 4 April 2003
Engineering › Diesel Engine (auxiliary)
Issued 19 March 2003 Resolved
Insulate/lag the exhaust pipe an the aux. diesel generator (detroit diesel). Also, lag or insulate the turbocharger body (exhaust side). LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Due 19 April 2003
Resolved 16 April 2003
Resolution: Lagging on aux. diesel generator exhaust pipe and turbocharger properly installed.
Engineering › Diesel Engine (auxiliary)
Issued 19 March 2003 Resolved
Prove proper operation of the aux. (detroit diesel) diesel generator overspeed trip. LEGACY COMPONENT DESC: Overspeed Device
Condition: Unknown
Due 19 April 2003
Resolved 16 April 2003
Resolution: Aux. diesel generator overspeed trip properly operated.