HR MARION

HR MARION is a 1999 freight ship. The Coast Guard has recorded 31 inspections since 1999, most recently in August 2014, along with 19 deficiencies.

Records from 1999 to 2014. Most recent: inspection, 9 August 2014.

Built
1999
Last inspected
9 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9164029 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
489305
Flag
LIBERIA
—
Maury page id
psix-489305

Inspections, by type

…with no type recorded11
Years with a record 11 calendar years (1999–2014)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5920 - Convention (Subpart B), Net Ton
11894 - Convention (Subpart B), Gross Ton
22829 - Displacement, Ton
17058 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 31

9 August 2014 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4948836
3 August 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4942528
26 May 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4865574
21 May 2014 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4864131
14 May 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4854924
5 August 2011 COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4100342
23 February 2010 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3684817
3 September 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3317248
18 June 2008 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3240445
22 August 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2756344
20 June 2006 Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2680064
14 February 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2584879
14 December 2005 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2551515
2 November 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2527359
21 September 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2498318
20 May 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2363406
12 February 2005 NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2291215
10 February 2005 NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2290270
20 October 2004 NPV Safety Exam · Ballast Water Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2224560
26 September 2004 ISPS I Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2203254
26 September 2004 Enhanced Seaway Inspection (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2203258
22 July 2003 Security Inspection · MARPOL Annex I Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1868141
16 July 2003 Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1842351
7 July 2003 Ballast Water Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1838680
6 December 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 296111
24 October 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 283249
27 October 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 433945
16 October 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 433641
31 August 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 432322
21 May 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 428725
6 May 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 428264

Deficiency record · 19

Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 14 May 2014 Resolved
The Electrical power available shall be sufficient to supply all those serices essential for safety in an emergency. Emergency generator would start and run but would not produce power. 74SOLAS98 CHE II-1 Reg 43.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2014
Resolution: Vessel submitted proper documentation of repair. See attached report.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 May 2014 Resolved
Any fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. Found numerous engine room smoke detectors being held up in place by plastic wire ties. Smoke detector in purifier room inoperable, changed at the time of examination. 74 SOLAS 91 Ammend. CH II-2 Reg 13.1.1
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 21 May 2014
Resolution: Vessel submitted proper documentation of repair. See attached report.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 May 2014 Resolved
Fire Doors of Class "A" boundaries in galleys shall be self closing. Found class "A" galley door to not close or operate automatically. 74 SOLAS 98 Amend. CH II-2 Reg 30.4.1
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 20 May 2014
Resolution: Vessel submitted proper documentation of repair. See attached report.
Accommodation/Occupational Safety › Ventilation › General
Issued 14 May 2014 Resolved
Machinery spaces of category "A" spaces shall be adequately ventilated and maintained. Found port side ventilation housing in engine room to be deteriorated completely through and being supported by a piece of wood. 74 SOLAS 98 CH II-1 Reg 35
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 20 May 2014
Resolution: Vessel submitted proper documentation of repair. See attached report.
Operations/Management › Pollution › Control of Garbage
Issued 18 June 2008 Resolved
2120 Garbage: Management Plan is not ship specific. Plan has blank spaces for ship specifics to be filled in, but they are blank. No crew position is identified as in charge. No processing and disposal conditions are identified. Create ship specific plan to the satisfaction of flag/class.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 June 2008
Resolved 3 September 2008
Resolution: Received E-mail with scanned approval of GMP from GL. Deficiency Rectified.
Navigation › Piloting/Steering › Swing Meter
Issued 14 June 2006 Resolved
Prove the proper operation of the rudder angle indicator on the bridge where it is currently not working SOLAS 74 II-2 /29 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2006
Resolution: Rudder angle indicator fixed.
Lifesaving › Buoyant Smoke Signals › General
Issued 14 June 2006 Resolved
replace the port life buoy self activating smoke signal with a properly activating corrosion free device. The existing smoke signal has excessive corrosion on the device. SOLAS 74 AMD III/31.3 Action 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2006
Resolution: Replaced with a new one.
Engineering › Pressure Vessel › Relief Valve
Issued 14 June 2006 Resolved
Remove the lamp on the relief valve for the incinerator and operate the incinerator to the satisfaction of class.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2006
Resolution: letter from class, certifying that clamp has been removed and incinerator is in proper working order.
Navigation › Piloting/Steering › Marine Charts
Issued 20 October 2004 Resolved
Charts, Light List, Coast Pilot were not currently correct.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 10 February 2005
Resolution: Agent contacted MSO San Francisco to verify chart and publication corrections.
Engineering › Fuel Oil Service System › Valve
Issued 20 October 2004 Resolved
Emergency fuel shut off for the emergency gererator was inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 February 2005
Resolution: Emergency generator remote fuel shut-off repaired, examined and tested, Result was found satisfactory by [name withheld] surveyor.
Fire Fighting › Fire Pumps › Pressure
Issued 16 July 2003 Resolved
Prove proper operation of emergency fire pump.
Due 16 July 2003
Resolved 16 July 2003
Resolution: Pump was air bound. Corrected prior to end of examination.
Fire Fighting › Miscellaneous Items › Paints/Varnishes/Other Finishes
Issued 10 July 2003 Resolved
Weather Deck Fire Plan being updated by 2nd Mate, to be stored to proper location prior to entering Seaway.
Action required: 705 - Other - as specified
Due 11 July 2003
Resolved 11 July 2003
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 7 July 2003 Resolved
All full cans of paint in foc'sleto be stored properly in paint locker prior to entry of the Seaway.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 11 July 2003
Navigation
Issued 31 August 1999 Resolved
Charts and publications to be on board.
Condition: Unknown
Due 6 September 1999
Resolved 3 September 1999
Navigation
Issued 6 May 1999 Resolved
PRIOR TO NEXT US PORT, PROPERLY LOG REQUIRED PRE-ARRIVAL AND DEPARTURE TESTS.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Lifesaving
Issued 6 May 1999 Resolved
PRIOR TO NEXT US PORT, STENCIL SHIPS NAME AND HOME PORT ON FORWARD LIFE RING AND PROVIDE LIGHT.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Navigation
Issued 6 May 1999 Resolved
PRIOR TO DEPARTURE, PROVIDE RADAR PLOTTING SHEETS.
Condition: Unknown
Due 6 May 1999
Resolved 7 May 1999
Lifesaving
Issued 6 May 1999 Resolved
PRIOR TO DEPARTURE PROVIDE FOUR (4) ROCKET PARACHUTE FLARES.
Condition: Unknown
Due 6 May 1999
Resolved 7 May 1999
Navigation
Issued 6 May 1999 Resolved
PRIOR TO DEPARTURE PROVIDE TIDAL CURRENT TABLE.
Condition: Unknown
Due 6 May 1999
Resolved 7 May 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.