Records from 2005 to 2025. Most recent: inspection, 24 November 2025.
Inspection history · 16
24 November 2025
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8273360
18 December 2023
Hull Examination · Administrative Inspection · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7840068
7 December 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7840845
26 May 2023
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7700144
6 February 2023
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7632566
20 January 2023
Deficiency Check · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7624306
20 January 2023
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7627358
19 September 2022
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7561917
22 November 2021
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7355826
2 October 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7069588
3 October 2019
Deficiency Check · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6835859
20 December 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6601030
10 October 2017
Hull Examination · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6285086
26 September 2017
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6275701
24 September 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6276137
19 July 2016
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5945616
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2023
Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Remove line on lights and add 18' line.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: 18' of line was added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 December 2023
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Clean bulkhead in way of wet spot inside engine room entrance and test. Crop and renew as original if needed.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: Area was cleaned, primed, and painted. No holes were found.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2023
Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Multiple pipes on the system were found to have patches or wastage. Crop and renew as original.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: Holed pipes were inserted with new piping and tested. No issues noted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2023
Resolved
A space containing diesel machinery must be fitted with adequate means such as dripproof ventilators, ducts, or louvers, to provide sufficient air for proper operation of main engines and auxiliary engines. 1 vent cover was warped. Repair/replace as original.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: Vent cover was straighted and fit tested. No issues noted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 December 2023
Resolved
The inspections and tests shall insure that the equipment and associated structure are in satisfactory operating conditions and fit for the service for which they are intended. The fire monitor piping prior to reaching the nozzle was leaking. Crop and renew.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: Piping was cropped and renewed and pressure tested. No leaks noted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 December 2023
Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight:(1)each hatch on a watertight trunk that extends at least 12 inches above the weather deck. The aft controlling station has an exposed hole on the side that is not watertight. Repair to restore weathertight integrity.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: A weathertight plate was installed over the opening.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 January 2023
Resolved
Other Alarms- Vessels described in 46 CFR 175.110 (d) must submit plans to the cognizant OCMI for the installation and use of monitoring device to ensure the wakefulness of the watchman required by paragraph (a). The Coast Guard will work with the vessel implementation schedule once the plans are accepted. The device must (1)ensure the wakefulness of the crew in the event the watchman is unresponsive.(2)remain operable during the nighttime watch and (3)be arranged to ensure proper coverage of the passenger accommodations spaces, common areas and spaces with potential fire hazards. Vessel is restricted from carrying overnight passengers until an approved system is installed to the satisfaction of the attending marine inspector.
46 CFR 185.410 (b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 26 May 2023
Resolution: Attended vsl and witnessed a sat test of the newly installed watchman alarm system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 January 2023
Resolved
Fire safety - Vessels described by 46 CFR 175.110 (c) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access including accommodation spaces and machinery spaces. Vessel has not installed the fire detection system as required. System must be approved by cognizant OCMI and inspected after installation by USCG Marine Inspector.
46 CFR 181.405 (c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 7 March 2023
Resolution: System installed and tested to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load under such requirements without exceeding its design limitations. While transiting to Port Aransas the vessel experienced a loss of lube oil pressure in the STBD MDE, vessel was en-route to repair a damaged blower on the Port MDE. Vessel was dead in the water requiring tow. Vessel will be towed to [name withheld] for repairs and may not depart until repaired to the satisfaction of the attending Marine Inspector.
46 CFR 182.200 Old T cite 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 January 2023
Resolution: Repairs made to both MDE's and tested to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2020
Resolved
Repair/replace all leaking valves in bilge line.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel repaired all leaking bilge valves.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 October 2020
Resolved
Repair leaking fitting on aft steering pump.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel replaced leaking hydraulic line with a new one.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 October 2020
Resolved
Replace all faded and fraying lines on all 3 life floats.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel replaced all frayed lines on their life floats with new line.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 October 2020
Resolved
Peform satisfactory fire and abandon ship drills.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Conducted satisfactory fire and abandon ship drills.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 October 2020
Resolved
Open forward hatch to fore-peak space and make available for inspection.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel opened fore peak hatch and space was inspected satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2020
Resolved
Repair emergency escape hatch in engine room and ensure it opens properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Engine room emergency escape hatch was repaired and operates satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2020
Resolved
Remove extension cord in engine room for the port shaft pump and make permanent connection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel installed new outlets.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2020
Resolved
Remove extension cords in galley by the freezers and underneath the television and make permanent connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel installed new outlets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2020
Resolved
Tighten packing gland on port and starboard shafts to stop ingress of water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel tightened packing glands on both shafts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2020
Resolved
Replace 3 life jackets where retro-reflective tape was painted over. Total persons allowed on vessel reduced to 33 until new life jackets are purchased.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel purchased 3 lifejackets and stenciled them properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 October 2020
Resolved
Replace lines on port and starboard bridge life rings.
Action required: 10 - Deficiency Rectified
Due 2 October 2020
Resolved 2 October 2020
Resolution: Owner replaced life rings with two new ones.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 2 October 2020
Resolved
Ensure GPS is connected to the radio with DSC. 47 CFR 80.905.
Action required: 10 - Deficiency Rectified
Due 2 October 2020
Resolved 2 October 2020
Resolution: Owner reconnected GPS wires to radio with DSC.