MAURY USCG vessel records Sign in
← All vessels

MISS ALLIE

MISS ALLIE is a 1976 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1981, most recently in November 2025, along with 88 deficiencies, 1 operational control and 8 casualty investigations between 2005 and 2023.

Records from 1981 to 2025. Most recent: inspection, 24 November 2025.

Built
1976
Last inspected
24 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8964032 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH2572
Flag
UNITED STATES
367598990
Maury page id
psix-48941

Inspections, by type

…with no type recorded22
Years with a record 42 calendar years (1981–2025)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)95.4 ft × 26.0 ft × 6.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOLLINS SEAFOOD INC · LAROSE, LA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH2572MMSI 367598990 · active · compulsorily equipped · granted 12 October 2023, expires 18 December 2033
WDC6896MMSI 367062850 · expired · compulsorily equipped · granted 18 August 2005, cancelled 24 October 2015
WCJ3897MMSI 366942530 · expired · compulsorily equipped · granted 23 April 2004, cancelled 6 September 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCY9407MMSI not assigned · expired · voluntarily equipped · granted 17 March 1999, cancelled 23 May 2009
WCW7717MMSI not assigned · expired · compulsorily equipped · granted 30 July 1996, cancelled 30 September 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS MEGAN Offshore Supply Vessel · MISLE 589276 · 24 September 2017 · activity 6276137SHIP ISLAND Industrial Vessel · MISLE 1262629 · 9 October 2015 · activity 5739800BULL SHARK Offshore Supply Vessel · MISLE 479976 · 6 March 2014 · activity 4811852HUDSON RIVER Offshore Supply Vessel · MISLE 48371 · 9 June 1998 · activity 102219

Inspection history · 78

24 November 2025 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8273360
18 December 2023 Hull Examination · Administrative Inspection · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7840068
7 December 2023 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7840845
26 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7700144
6 February 2023 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7632566
20 January 2023 Deficiency Check · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7624306
20 January 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7627358
19 September 2022 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7561917
22 November 2021 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7355826
2 October 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7069588
3 October 2019 Deficiency Check · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6835859
20 December 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6601030
10 October 2017 Hull Examination · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6285086
26 September 2017 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6275701
24 September 2017 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6276137
19 July 2016 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5945616
9 October 2015 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5739800
29 September 2015 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5737105
6 March 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4811852
4 March 2014 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4815008
18 June 2012 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4340582
1 December 2011 Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4189142
2 August 2011 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4102605
20 July 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4088191
19 July 2011 DAPI Audit · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4078817
10 December 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3910237
17 June 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3239399
5 October 2007 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3073832
19 September 2007 Hull Examination · Administrative Inspection · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3061548
17 July 2007 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2998804
19 March 2007 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2925006
10 May 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2645543
5 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2641648
2 May 2006 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2638918
24 April 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2645031
19 April 2006 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2624085
20 March 2006 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2605653
22 August 2005 Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2471105
11 March 2005 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2311881
10 February 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2293885
12 July 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2130430
28 June 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2158542
9 June 2003 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1813183
15 July 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1646321
30 August 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1072810
29 August 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1071749
12 July 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405216
6 April 2000 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464938
24 November 1999 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812671
3 August 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 766393
30 July 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 209746
7 June 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420149
3 June 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807763
31 March 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119570
17 March 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418490
9 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102219
30 March 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460175
23 September 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 97466
25 March 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418148
7 June 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187698
11 April 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463229
17 April 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357134
13 May 1994 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436870
14 April 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432669
29 April 1992 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472999
16 May 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909026
11 April 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1235447
8 May 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924600
12 April 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1352290
25 May 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204780
6 April 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1026887
7 May 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294608
9 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291080
5 November 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 976929
4 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280454
6 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279711
17 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276252
19 June 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279336

Deficiency record · 88

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2023 Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Remove line on lights and add 18' line.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: 18' of line was added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 December 2023 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Clean bulkhead in way of wet spot inside engine room entrance and test. Crop and renew as original if needed.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: Area was cleaned, primed, and painted. No holes were found.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2023 Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Multiple pipes on the system were found to have patches or wastage. Crop and renew as original.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: Holed pipes were inserted with new piping and tested. No issues noted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2023 Resolved
A space containing diesel machinery must be fitted with adequate means such as dripproof ventilators, ducts, or louvers, to provide sufficient air for proper operation of main engines and auxiliary engines. 1 vent cover was warped. Repair/replace as original.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: Vent cover was straighted and fit tested. No issues noted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 December 2023 Resolved
The inspections and tests shall insure that the equipment and associated structure are in satisfactory operating conditions and fit for the service for which they are intended. The fire monitor piping prior to reaching the nozzle was leaking. Crop and renew.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: Piping was cropped and renewed and pressure tested. No leaks noted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 December 2023 Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight:(1)each hatch on a watertight trunk that extends at least 12 inches above the weather deck. The aft controlling station has an exposed hole on the side that is not watertight. Repair to restore weathertight integrity.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 January 2024
Resolved 26 January 2024
Resolution: A weathertight plate was installed over the opening.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 January 2023 Resolved
Other Alarms- Vessels described in 46 CFR 175.110 (d) must submit plans to the cognizant OCMI for the installation and use of monitoring device to ensure the wakefulness of the watchman required by paragraph (a). The Coast Guard will work with the vessel implementation schedule once the plans are accepted. The device must (1)ensure the wakefulness of the crew in the event the watchman is unresponsive.(2)remain operable during the nighttime watch and (3)be arranged to ensure proper coverage of the passenger accommodations spaces, common areas and spaces with potential fire hazards. Vessel is restricted from carrying overnight passengers until an approved system is installed to the satisfaction of the attending marine inspector. 46 CFR 185.410 (b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 26 May 2023
Resolution: Attended vsl and witnessed a sat test of the newly installed watchman alarm system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 January 2023 Resolved
Fire safety - Vessels described by 46 CFR 175.110 (c) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access including accommodation spaces and machinery spaces. Vessel has not installed the fire detection system as required. System must be approved by cognizant OCMI and inspected after installation by USCG Marine Inspector. 46 CFR 181.405 (c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 7 March 2023
Resolution: System installed and tested to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load under such requirements without exceeding its design limitations. While transiting to Port Aransas the vessel experienced a loss of lube oil pressure in the STBD MDE, vessel was en-route to repair a damaged blower on the Port MDE. Vessel was dead in the water requiring tow. Vessel will be towed to [name withheld] for repairs and may not depart until repaired to the satisfaction of the attending Marine Inspector. 46 CFR 182.200 Old T cite 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 January 2023
Resolution: Repairs made to both MDE's and tested to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2020 Resolved
Repair/replace all leaking valves in bilge line.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel repaired all leaking bilge valves.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 October 2020 Resolved
Repair leaking fitting on aft steering pump.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel replaced leaking hydraulic line with a new one.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 October 2020 Resolved
Replace all faded and fraying lines on all 3 life floats.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel replaced all frayed lines on their life floats with new line.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 October 2020 Resolved
Peform satisfactory fire and abandon ship drills.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Conducted satisfactory fire and abandon ship drills.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 October 2020 Resolved
Open forward hatch to fore-peak space and make available for inspection.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel opened fore peak hatch and space was inspected satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2020 Resolved
Repair emergency escape hatch in engine room and ensure it opens properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Engine room emergency escape hatch was repaired and operates satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2020 Resolved
Remove extension cord in engine room for the port shaft pump and make permanent connection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel installed new outlets.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2020 Resolved
Remove extension cords in galley by the freezers and underneath the television and make permanent connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel installed new outlets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2020 Resolved
Tighten packing gland on port and starboard shafts to stop ingress of water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel tightened packing glands on both shafts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2020 Resolved
Replace 3 life jackets where retro-reflective tape was painted over. Total persons allowed on vessel reduced to 33 until new life jackets are purchased.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 15 October 2020
Resolution: Vessel purchased 3 lifejackets and stenciled them properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 October 2020 Resolved
Replace lines on port and starboard bridge life rings.
Action required: 10 - Deficiency Rectified
Due 2 October 2020
Resolved 2 October 2020
Resolution: Owner replaced life rings with two new ones.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 2 October 2020 Resolved
Ensure GPS is connected to the radio with DSC. 47 CFR 80.905.
Action required: 10 - Deficiency Rectified
Due 2 October 2020
Resolved 2 October 2020
Resolution: Owner reconnected GPS wires to radio with DSC.
Construction/Loadline › Structures › Deck Plating
Issued 8 October 2015 Resolved
Complete deck and bullwarks repair to port side of vessel caused by collision with another vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2015
Resolution: All repairs were sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 July 2011 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 19 July 2011
Resolved 19 July 2011
Resolution: Completed COI.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 July 2011 Resolved
Cracks present on overhead exhaust supports. Reweld supports for port and starboard main engine exhaust piping.
Action required: 705 - Other - as specified
Due 19 August 2011
Resolved 2 August 2011
Resolution: Inspected welded supports for port and starboard main engine exhaust piping. All Sat.
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 19 July 2011 Resolved
Replace all unproper fuel hoses to meet SAE J-1942 standard on the port and stbd main engines.
Action required: 705 - Other - as specified
Due 19 August 2011
Resolved 2 August 2011
Resolution: Inspected All fuel hoses on port and starboard main engines, all meet SAE J-1942 standards. All Sat.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 19 July 2011 Resolved
Cracks present in fire bowl of raycor filter on port main engine. Replace fire bowl.
Action required: 705 - Other - as specified
Due 19 August 2011
Resolved 2 August 2011
Resolution: Raycor filter bowl replaced on port main engine. All Sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 July 2011 Resolved
Failure to give written notice 30-90days prior to expiration of Ceriticate of Inspection.
Action required: 705 - Other - as specified
Due 20 August 2011
Resolved 19 July 2011
Resolution: Completed COI.
Documentation › Logs/Records › Logbook (official)
Issued 17 June 2008 Resolved
Ensure proper entry in ship's log, especally drills, EPIRB test, and condition of vessel prior to departure.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 15 June 2010
Resolution: Drills and safety gear checks properly logged
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 June 2008 Resolved
Missing tide tables, current tables and notice to mariners publications
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 26 June 2008
Resolution: Received receipt of purchase.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 June 2008 Resolved
Hardwire permanently installed equipment in engine room.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 26 June 2008
Resolution: Received third party receipt.
Operations/Management › Drills/Instruction › Fire
Issued 17 July 2007 Resolved
Emergency drills and monthly EPIRB checks were not properly documented.
Action required: 705 - Other - as specified
Resolved 5 October 2007
Communications › Audible Communications › Horn/Whistle
Issued 17 July 2007 Resolved
The ship's whistle was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2007
Lifesaving › Lifebuoys › Immediately Available
Issued 17 July 2007 Resolved
One life ring buoy needed to be restenciled.
Action required: 705 - Other - as specified
Resolved 17 July 2007
Resolution: Corrected
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 17 July 2007 Resolved
A section of exhaust lagging on the starboard engine was missing.
Due 17 August 2007
Resolved 5 October 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 17 July 2007 Resolved
Additional emergency lighting was needed in the accommodation space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 July 2007 Resolved
An exhaust leak was found on the port engine.
Action required: 705 - Other - as specified
Resolved 5 October 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 17 July 2007 Resolved
The emergency exit from the engine room was not labeled.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2007
Resolution: Corrected
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 17 July 2007 Resolved
Flammables stores were found throughout the vessel and not kept withing the paint locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2007
Resolution: Corrected
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 17 July 2007 Resolved
A small fuel leak was found on the port and starboard engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2007
Resolution: Corrected by mechanic
Stability › Water on Deck › General
Issued 17 July 2007 Resolved
Excess water was found in the engine room bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 19 March 2007 Resolved
Place rubber mat in front of E/R switchboard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 19 March 2007 Resolved
Label switchboard
Due 19 April 2007
Resolved 21 March 2007
Engineering › Lubricating Oil Service System › Gauge
Issued 19 March 2007 Resolved
Repair leak at stbd MDE gauges
Due 19 April 2007
Resolved 21 March 2007
Engineering › Fuel Oil Service System › Piping
Issued 19 March 2007 Resolved
Repair leaks at port/stbd MDE's and at fuel station piping union
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 March 2007 Resolved
Renew missing exhaust lagging & remove oil stained port lagging
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 March 2007 Resolved
Remove dead wiring over port MDE
Due 19 April 2007
Resolved 21 March 2007
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 19 March 2007 Resolved
Clean both generator armatures
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 19 March 2007 Resolved
Renew emergency lighting at stbd E/R emergency exit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 March 2007 Resolved
Remount electtrical junction box above stbd MDE
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Engineering › Fuel Oil Service System › Filter
Issued 19 March 2007 Resolved
Place burn bowels on raycor fuel filters
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 19 March 2007 Resolved
Rig dryer vent to remove combustible lint from space.
Due 19 April 2007
Resolved 21 March 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 March 2007 Resolved
Label electrical circuit breakers by E/R fwd ladder.
Due 19 April 2007
Resolved 21 March 2007
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 5 May 2006 Resolved
Provide BWM plan IAW 33 CFR Subpart D
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 21 March 2007
Construction/Loadline › Hull › Hull Plating
Issued 5 May 2006 Resolved
Properly insert cut-out for starboard MDE gear box replacement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2006
Communications › Audible Communications › SPD (Other)
Issued 5 May 2006 Resolved
Provide Public address system.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 May 2006 Resolved
Provide not under command nav. lights.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 2 May 2006 Resolved
Vessel operated without full compliment of crew as required by vessel's COI
Action required: 705 - Other - as specified
Due 2 July 2006
Resolved 5 May 2006
Resolution: Full compliment of crew on-board.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 2 May 2006 Resolved
Failure to have a licensed master onboard an inspected small passenger vessel.
Action required: 705 - Other - as specified
Due 2 July 2006
Resolved 5 May 2006
Resolution: Provided licensed master.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 2 May 2006 Resolved
Failure to secure type III MSD prior to operating in an area where the discharge of raw sewage is prohibited by the EPA.
Action required: 705 - Other - as specified
Due 2 July 2006
Resolved 5 May 2006
Resolution: Provide lock with chain.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 2 May 2006 Resolved
Failure to submit a sailing short report.
Action required: 705 - Other - as specified
Due 2 July 2006
Resolved 5 May 2006
Resolution: Provided full compliment of crew.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 March 2006 Resolved
No valid COI on-board.
Due 16 May 2006
Resolved 20 April 2006
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 20 March 2006 Resolved
No BWM plan on-board.
Due 16 May 2006
Resolved 20 April 2006
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 March 2006 Resolved
Operating vessel without full compliment of crew.
Due 16 May 2006
Resolved 20 April 2006
Operations/Management › Pollution › Retention of Oily Mixture
Issued 25 August 2005 Resolved
Remove all diesel oil from the engine room bilge space.
Action required: 705 - Other - as specified
Resolved 20 April 2006
Construction/Loadline › Structures › Deck Plating
Issued 22 August 2005 Resolved
Crop and renew three (3) gussets as marked located on the port side of the lazarette.
Action required: 705 - Other - as specified
Resolved 20 April 2006
Construction/Loadline › Hull › Weld
Issued 22 August 2005 Resolved
Reweld three (3) gussets on the hull plating in way of the starboard main engine.
Action required: 705 - Other - as specified
Resolved 20 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 22 August 2005 Resolved
Crop and renew 2.5 ft X 3 ft section of bulwark located above the starboard transom.
Action required: 705 - Other - as specified
Resolved 20 April 2006
Construction/Loadline › Structures › Manhole
Issued 22 August 2005 Resolved
Crop and renew the uppermost rung in ladder located in the forepeak compartment.
Action required: 705 - Other - as specified
Resolved 20 April 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 July 2003 Resolved
Provide 2003 Light list.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 July 2003 Resolved
Provide 2003 Current/Tide tables.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Deck/Cargo › Holds/Tanks
Issued 7 July 2003 Resolved
Provide deck vents plugs for all deck vents. LEGACY COMPONENT DESC: Deck vents
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Lifesaving › Buoyant Apparatus
Issued 7 July 2003 Resolved
Provide new retro tape for all lifefloats. LEGACY COMPONENT DESC: Lifefloats
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 July 2003 Resolved
Repair starboard running light.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Engineering › Fuel Oil Service System › Hose
Issued 7 July 2003 Resolved
Repair port main engine fuel leak.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2003
Resolved 7 July 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 July 2002 Resolved
NO UPDATED 2002 LIGHT LIST AVAILABLE ONBOARD.
Due 15 August 2002
Resolved 15 July 2002
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 July 2002 Resolved
NO UPDATED COMPASS DEVIATION CARD ONBOARD.
Due 15 August 2002
Resolved 15 July 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 15 July 2002 Resolved
NO FLAME SCREENS LOCATED IN 4 FUEL OIL DECK VENTS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2002
Resolved 15 July 2002
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 15 July 2002 Resolved
NO MOUNTING BRACKET FOR CO2 BOTTLE HORN/HOSE ASSEMBLY.
Due 15 August 2002
Resolved 15 July 2002
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 15 July 2002 Resolved
NO EMERGENCY LIGHT LOCATED NEAR ESCAPE HATCH IN ENGINEROOM.
Due 15 August 2002
Resolved 15 July 2002
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 15 July 2002 Resolved
110 VOLT PANEL IN ENGINEROOM FRONT COVER NOT PERMENANTELY ATTACHED.
Due 15 August 2002
Resolved 15 July 2002
Fire Fighting
Issued 29 August 2001 Resolved
Deck monitor fire pump inop. Vsl allowed to xfer fuel in Berwick, LA. The master must ensure proper operation of 2ndary fire pump prior to fule xfer and prior to departure to La Rose, LA, where proper repair to the monitor pump will be completed.
Condition: Unknown
Due 29 August 2001
Resolved 29 August 2001
Fire Fighting
Issued 12 July 2001 Resolved
DEMONOSTRATE CREW PROFICIENCY IN FIRE FIGHTING AND ABONDON SHIP DRILLS TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 12 July 2001
Resolved 12 July 2001
Construction/Loadline
Issued 17 March 1999 Resolved
REPAIR/ REPLACE WASTED KNIFE EDGE AND WORN HINGES ON MAINDECK ENGINE ROOM WTD. COMPLETE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Construction/Loadline
Issued 17 March 1999 Resolved
REPAIR/ REPLACE BRIDGE WEATHER TIGHT DOOR. COMPLETE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Construction/Loadline
Issued 17 March 1999 Resolved
REPAIR/ REPLACE ENGINE ROOM WTH TO THE SATISFACTION OF THE ATTENDING MARINEINSPECTOR.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Construction/Loadline
Issued 17 March 1999 Resolved
REPAIR/ REPLACE WORN HINGES ON MAINDECK WTD TO CREWS LOUNGE. COMPLETE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Engineering
Issued 11 April 1991 Resolved
INSTALL PILOT HOUSE STARTS AND STOPS FOR MAIN ENGINES IAW 46 CFR 175.10-29.AS AN ALTERNATIVE MEANS OF COMMUNICATION, A SYSTEM INSTALLED UNDER _x001C_ 46 CFR 184.35-1 MAYBE CONSIDERED AND APPROVED BY THE OCMI.
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Documentation
Issued 5 November 1984 Resolved
OBTAIN A COMMUNICATIONS ACT SAETY RADIOTELEPHONY CERTIFICATE WITHIN THE NEXT NINETY (90) DAYS FROM THE FCC, NO LATER THAN 5FEB85.
Condition: Unknown
Due 5 November 1984
Resolved 5 November 1984

Casualty record · 8

10 February 2005Routine · role: Involved in a Marine Casualty · activity 2293885
11 March 2005Routine · role: Involved in a Marine Casualty · at CSX RR BRIDGE (011) · activity 2311881
24 December 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4507748
6 March 2014Routine · role: Involved in a Marine Casualty · activity 4811852
15 November 2014Routine · role: Involved in a Marine Casualty · activity 5032839
9 October 2015Routine · role: Involved in a Marine Casualty · activity 5739800
24 September 2017Routine · role: Involved in a Marine Casualty · activity 6276137
20 January 2023Routine · role: Involved in a Marine Casualty · activity 7627358
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 3

NAVIGATOR (2005), INT'L NAVIGATOR (2005), MISS BRIANNA (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.