Records from 2016 to 2025. Most recent: inspection, 12 November 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 26
12 November 2025
ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8210651
1 October 2024
Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7976540
17 November 2023
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7795525
18 May 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7689686
18 May 2023
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7850929
25 January 2023
Re-Inspection · ACP COI Oversight · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7572292
8 September 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7505871
19 July 2022
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7507801
26 July 2021
Drydock Exam · ACP Drydock Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7268586
19 July 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7261559
16 April 2020
Re-Inspection · ACP COI Oversight · COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6937070
6 February 2019
ACP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6577735
28 September 2018
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6549225
1 May 2018
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6403565
6 March 2018
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6371328
1 March 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6343867
7 August 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6233103
17 April 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6126600
8 March 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6089962
28 October 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6034951
2 September 2016
Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5990429
22 August 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5939916
20 May 2016
MTSA Verification · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5882170
9 March 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829355
8 February 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5821178
26 January 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5797778
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2024
Resolved
In locations where means of ignition are present ...precautions shall be taken to prevent any oil ... from coming into contact with heated surfaces. Found missing/improper installation of insulation on EDG Turbo Charger, ROS Turbo Charger, and Superheated steam line leading to de-superheater on STBD power boiler.
74 SOLAS II-2 / 33
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2024
Resolved 15 October 2024
Resolution: see narrative
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Motor heater indicator for #1 Steering Gear Motor is showing the heater is not turning on when motor is off.
74 SOLAS (20 Consl.) I / 11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2024
Resolved 15 October 2024
Resolution: see narrative
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 November 2023
Resolved
The drills of the crew shall take place with in 24HR of the ship leaving a port in more than 25% of the crew have not participated in abandon ship and fire drills on board that particular ship in the previous month.
Vessel must perform fire and abandon ship drills in the presence of a CG MI. Prior to activation.
SOLAS 74 (Cons 14) III Reg 3.2
Action required: 705 - Other - as specified
Resolved 9 July 2026
Resolution: Crew performed Security, Fire and Abandonship drill; all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 November 2023
Resolved
Contracting governments undertake for each of its ships shall be sufficiently and effectively manned. A full
compliment of licensed officers and crew as per the COI
prior to activation.
SOLAS 74 (Cons 14) V, Reg 14.1
Action required: 705 - Other - as specified
Resolved 9 July 2026
Resolution: Attended vessel ensured all 29 crewmebers were onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 November 2023
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliance shall be in working order and ready for immediate use. Provide and put in place all lifesaving appliances. Prior to activation.
SOLAS 74 (Cons 14) III Reg 20.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 July 2026
Resolution: Ensured all lifesaving applaince were inplace.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 November 2023
Resolved
Every ship which does not carry a doctor shall be provided with an approved medicine chest with readily understandable instructions. Provide proper medicine supplies in the hospital space prior to activation.
ILO NO 147 Reg 26
Action required: 705 - Other - as specified
Resolved 9 July 2026
Resolution: Ensured all medicine was onboard and hospital space was adequate supplied.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 July 2022
Resolved
The vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The continued validity of a vessel’s COI is contingent upon the satisfaction of the annual, periodic and re-inspection requirements. Vessel has been granted a deferment for the completion of a annual inspection and must complete a satisfactory annual inspection by 16SEP22. Vessel's current COI issued dated 16APR2020-25 will remain valid throughout deferment period.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2022
Resolved 8 September 2022
Resolution: Vessel completed satisfactory annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 April 2020
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out based on the guidelines ... and in a manner having due regard to ensuring reliability of such appliances. The batteries on all the lights for the life jackets have expired. Lights shall be replaced within 30 days or prior to activation, whichever is sooner.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2020
Resolved 7 May 2020
Resolution: Lights renewed and verified by RO
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 16 April 2020
Resolved
Flammable Compressed Gas Cylinders must always be secured in Lockers or housings, must be vented to the open air near the top and bottom for positive circulation of vapors and must be protected from all sources of heat which may cause the cylinders to be heated to a temperature higher than 130 °F. MI identified spare propane compressed gas cylinders stored in unapproved locations such as the air intake space on the fan tail and within the Package Boiler Container. Provide appropriate storage for spare propane cylinders.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2020
Resolved 7 May 2020
Resolution: Vessel removed spare Propane cylinders.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 7 February 2019
Resolved
The company should establish procedures, plans, and instructions, including checklists as appropriate for key shipboard operations. There is no checklist or procedure for the crew to verify rescue boat inventory on a quarterly basis as per the MOU between MARAD and the USCG.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 February 2019
Resolution: Cleared by ABS verfied by MI.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 February 2019
Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. All escape hatches and scuttles on the main deck and through out the cargo areas either have visible light through the gasket seal or the dogging mechanisms are inoperable.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 February 2019
Resolution: Cleared by ABS verfied by MI.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 February 2019
Resolved
The purpose of this part is to require the fullest practical degree of protection from fire by regulation of the details of arrangement and construction. Containment, extinction, or detection of and fire in the space of origin. Fire boundary indication panel in fire control room for cargo was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 February 2019
Resolution: Cleared by ABS verfied by MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Hydraulic start solenoid for the emergency generator leaks excessive amounts of hydraulic fluid. This does not allow the accumulators to maintain adequate pressure for required starts.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Cleared by ABS verfied by MI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 February 2019
Resolved
Not less than 12 rocket parachute flares shall be carried and be stowed on or near the navigation bridge. Vessel only has 8 rockets flares onboard.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2019
Resolution: Vessel probided 4 additional rocket flares/
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 February 2019
Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. Ventilation access hatches on B deck are missing nuts and securing studs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 February 2019
Resolution: Cleared by ABS verfied by MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 February 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. MI identified multiple holes and 6-8" crack in boiler main exhaust stack.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 February 2019
Resolved
Maintenance testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fie fighting systems and appliances. CO2 fire suppression branch lines have not been blown through IAW manufacture maintenance requirements. There are records showing this being performed but there is no indication of the dirt traps ever being removed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Cleared by ABS verfied by MI.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 6 February 2019
Resolved
Each survival craft shall be stowed so that it is fully equipped as required by the Code, and that batteries not marked with an expiration date be renewed annually. Lifeboat batteries were not marked with an expiration and were noted with a manufacturing date of January 2017. Vessel must prove acceptable life of the battery and mark accordingly, or renew annually.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 February 2019
Resolution: Cleared by ABS verfied by MI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 6 February 2019
Resolved
Launching and embarkation appliances complying with the requirements of section 6.1 of the Code shall be provided for all survival craft. Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off power to prevent over- stressing the falls or the davits. The anti-two block safety on the rescue boat was too short, and not operating as designed to stop the winch during recovery. Prove proper operation as designed.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2019
Resolution: Cleared by ABS verfied by MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019
Resolved
The power available shall be sufficient to supply all those services which are, in the opinion of the Administration, necessary for the safety of all on board in an emergency. Emergency Diesel Generator gages are inoperable or are not accurate for the engine and the switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2019
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 February 2019
Resolved
The drills of the crew shall take place with in 24HR of the ship leaving a port in more than 25% of the crew have not participated in abandon ship and fire drills on board that particular ship in the previous month. Vessel must perform fire and abandon ship drills in the presence of a CG MI. Prior to activation.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 April 2020
Resolution: Reissued deficiency as worklist during COI Reinspection 16 April 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 February 2019
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliance shall be in working order and ready for immediate use. Provide and put in place all lifesaving appliances. Prior to activation.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 April 2020
Resolution: Reissued as a worklist item during the COI re-inspection16 April 20
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 February 2019
Resolved
All ship's irrespective of size, shall have nautical charts and publications to plan and display the ship's route for intended voyage and to plot and monitor positions throughout the voyage. Vessel shall provide charts and publication for intended voyages. Prior to activation.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 April 2020
Resolution: Reissued as a worklist item during the COI re-inspection16 April 20
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 February 2019
Resolved
Contracting governments undertake for each of its ships shall be sufficiently and effectively manned. Provide full compliment of licensed officers and crew as per the COI. Prior to activation.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 April 2020
Resolution: Reissued as a worklist item during the COI re-inspection16 April 20
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 February 2019
Resolved
Watertight door indicators shall be fitted which show, at all operating stations from which the doors are not visible, whether the door is open or closed.
Type III water tight door leading from engine room to the shaft alley does not demonstrate proper light configuration for the position of the door at remote indication stations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2019
Resolution: Corrected operation and indication of WTD all working properly.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 February 2019
Resolved
Maintenance , testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. There no records of annual testing of CO2 suppression systems for cargo spaces.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2019
Resolution: Report provided. Conducted by Breakwater Int. JUN2018
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 February 2019
Resolved
Fire extinguishers shall be periodically examined and subjected to such tests as the Adminstration may require. 03 fire extinguishers requires hydrostatic testing and recharging as per fire servicing report. Corrective action report is missing, and crew could identify the 03 fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2019
Resolution: Report provided for corrective active of fire extinguishers. Verfied each extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 6 February 2019
Resolved
Each cargo ship shall carry at least one rescue boat complying with the requirements of section 5.1 of the code, where it is required that the rescue boat shall be provided with sufficient fuel to maneuver at a speed of 6kts for a period of at least 4 hrs. Fuel on board the rescue boat was marked as outdated and renewed on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 February 2019
Resolution: Fuel replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 February 2019
Resolved
Each cargo ship shall carry at least one rescue boat complying with the requirements of section 5.1 of the code and the rescue boat shall be stowed in a state of continuous readiness for launching in not more than 5 min. In the Rescue Boat, the first aid kit was outdated and flashlight needed batteries replaced. New first aid kit was furnished and flashlight batteries were replaced on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 February 2019
Resolution: Flashlight and first aid kit replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 February 2019
Resolved
Employers must ensure that they and their crew members meet the requirements of this part (Chemical Testing). Vessel does not have proof current enrollment in a chemical testing program for 2019.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2019
Resolution: Current enrollment form provided.
Operations/Management › Drills/Instruction › Fire
Issued 1 March 2018
Resolved
Conduct satisfactory fire, abandon ship, and security drill prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2018
Resolution: Conducted satisfactory Fire, Abandon, and Security drills.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 1 March 2018
Resolved
Make permenant repairs to holed plating above aft emergency gear locker, below mooring chock located on deck.
Action required: 705 - Other - as specified
Due 15 April 2018
Resolved 1 May 2018
Resolution: Permanant repairs were made to the deck below the closed chock. Deck plating was cropped and renewed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 1 March 2018
Resolved
Mount vent control switch for aft C02 control for vehicle garage ventilation shut down.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 12 March 2018
Resolution: Ventilation shutdown switch was properly secured to the bulkhead in the aft CO2 room.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 7 August 2017
Resolved
Replace gaskets and pneumatic ram for hydraulic pump room for stern ramp damper.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 8 November 2017
Resolution: ABS surveyor attended vessel and verified proper operation of the damper and its ability to operate as designed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 March 2017
Resolved
Conduct fire, abandonship and security drills prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2017
Resolution: Drill were conducted.
Navigation › Piloting/Steering › Marine Charts
Issued 8 March 2017
Resolved
Provide updated navigational pubs and charts prior to getting underway
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2017
Resolution: Nav pubs and charts were provided.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 March 2017
Resolved
Provide minimum crew prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2017
Resolution: proper crew was on board as required by the vessels COI.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 8 March 2017
Resolved
Provide current copies of identified SOLAS documents.
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 17 April 2017
Resolution: Vessel provided (05) identifed SOLAS documents.
Deck/Cargo › Cargo Condition › Other Cargo Type
Issued 8 March 2017
Resolved
Replace missing dogs on escape hatches, B deck and D deck.
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 17 April 2017
Resolution: Vessel renewed dogs on (02) escape hatches on B deck and (01) hatch on D deck.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 27 January 2016
Resolved
Conduct satisfactory fire, security, and abandon ship drills prior to getting underway.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2017
Resolved 22 August 2016
Resolution: Conducted satisfactry fire, security, and abandon ship drills.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 27 January 2016
Resolved
Provide USCG approved SOLAS rescue boat engine.
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 9 March 2016
Resolution: Cleared and notified ABS