Records from 2016 to 2026. Most recent: inspection, 1 June 2026.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 August 2025
No resolution recorded
Provide and reconfigure Nav lights meeting UL 1104. To include Port and starboard side lights, fore mast and stern lights. P/S lights need to be remounted to provide Nav light screens behind them. Prior to operating at night or during periods of reduced visibility.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 August 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 August 2025
Resolved
Provide alcohol test strips.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2025
Resolved 27 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2025
Resolved
Provide current EPIRB NOAA registration. Prior to operating beyond 3 Nautical miles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 August 2025
Resolved 3 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 April 2025
Resolved
Grind out suspect crack in metal on stbd rudder for examination.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
Resolution: Ground down and not cracked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2025
Resolved
Replace PVC in bilge manifold piping with same metallic piping in remainder of system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
Resolution: Replaced with metallic.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2025
Resolved
Double hose clamp bilge manifold sea water valve and starboard exhaust raw water supply.
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 April 2025
Resolved
Install machinery belt guard for genset in centerline.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2025
Resolved
Replace wing nut on aux battery with permanent connection.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2025
Resolved
Remove dead end wire on aft engine room bulkhead and remove dead end wire on bulkhead forward of starboard engine.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 April 2025
Resolved
Properly secure starboard upper deck railing to support 200 pound point load.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
Resolution: Fabricated new footer securing points out of aluminum and installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 July 2024
Resolved
Needs fisheries endorsement
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2024
Resolved 22 August 2024
Resolution: After some research vessel does not need fisheries endorsement if it does not offload catch.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 July 2024
Resolved
Liferafts and paddles did not have name of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 July 2024
Resolved
EPIRB hydro date not marked
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2024
Resolved
Life ring vessel name worn off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2024
Resolved
Electrical wires in E/R need to be secured every 24"
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2024
Resolved
Twist off wire tires not allowed.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 29 July 2024
Resolved
Top deck front ladder needs to be marked with no pax allowed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 July 2024
Resolved
Remove excessive oil from engine room bilges. E/R bilge by the generator had approx 2" of black oil.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 July 2024
Resolved
E/R smoke detector was on the floor with the battery compartment open. Required it to be mounted and serviceable.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2024
Resolved
Dead end wires in E/R must be removed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2024
Resolved 29 August 2024
Resolution: Removed
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 29 July 2024
Resolved
Bilge manifold was not labeled.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 29 July 2024
Resolved
VHF radio had MMSI but did not have lat/long.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2023
Resolved
Smoke detection systems not operating properly. The interconnectivity was not working.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2023
Resolved 26 September 2023
Resolution: Detectors properly connected while on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 September 2023
Resolved
Vessel failed to meet its inspection date and was restricted from operating until inspection complete.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2023
Resolved 26 September 2023
Resolution: Completed inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 September 2022
Resolved
Vessel had 04 [name withheld] PFDs that were recalled and not sufficient for maritime service. Lowered passenger count by four until PFDs replaced.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 4 January 2023
Resolution: Bought and installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 22 September 2022
Resolved
Vessel could not prove all crew were enrolled in a maritime consortium. Issued requirement to prove all vessel personnel enrolled.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: Provided proof
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 September 2022
Resolved
Vessel is required to have a properly mounted fire ax. The vessels fire ax was in a closet buried underneath items and took several minutes to find. Issued deficiency to mount fire ax.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: Mounted
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 22 September 2022
Resolved
Vessels AIS system did not work upon energizing system. Verified non-compliance through Marine Traffic.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 24 April 2023
Resolution: AIS displaying properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2022
Resolved
Vessels main fire pump did not work. Vessel was able to show use of auxiliary pump. Issued requirement to prove proper operation of vessels fire pump and to show proof of gauge at 60psi.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 4 January 2023
Resolution: O/O attests that fire pump is installed and operational.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 22 September 2022
Resolved
Vessel audible portion of the #3 tank high water alarm was inop. Issued requirement to fix it.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: Fixed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 September 2022
Resolved
Vessel is required to have current charts on board. Vessel is required to have a Coast Pilot on board. Vessel did not.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: On board
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 September 2022
Resolved
Vessel was missing items in the vessels first aid kit required by regulation. Specifically missing ammonia inhalants.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: Bought.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 September 2022
Resolved
Owner / operator shall schedule and successfully complete an annual inspection prior to the carriage of passengers as witnessed by the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2022
Resolved 22 September 2022
Resolution: Conducted annual inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022
Resolved
Cable and wiring required to be installed with metal support spaced not more than 24 inches apart IAW 46 CFR 183.340(b)(4).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022
Resolved
Electrical equipment must be bonded. In lazarette port side had non bonded wire IAW 46 CFR 183.372(a).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022
Resolved
Prevent electrical ignition of flammable vapor. In lazarette, light had missing plug to connection port IAW 46 CFR 183.200(d).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 June 2022
Resolved
Engine exhaust effectively insulated. Exhaust lagging on port inboard and starboard inboard exhaust pipes needs replaced up to cooling exhaust water IAW 46 CFR 182.425(b)(3).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 June 2022
Resolved
Provision must be made for closing all supply duct for space protected by a fixed gas extinguishing system. Vent to engine room (dog house) was not able to be fully closed IAW 46 CFR 182.465(h).
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 April 2022
Resolved
Vessel ran aground damaging both props, rudders and stripping FRP warp from the keel and various places on the port side.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2022
Resolved 7 June 2022
Resolution: Repairs were completed to the satisfaction of attending MI.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 June 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2020
Resolved
Replace both port and stbd aft cutlass bearings
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2020
Resolved 5 March 2020
Resolution: Replaced port and stbd aft cutlass bearings
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2019
Resolved
Label number and size of life jackets in stowage containers located on the 2nd deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2019
Resolved 29 May 2019
Resolution: Labels afixed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 May 2019
Resolved
Remove DOT tape from life float and install approved SOLAS retroflective tape.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 29 May 2019
Resolution: SOLAS tape used
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2019
Resolved
Missing spanner wrench for fire plug
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 9 June 2020
Resolution: Spanner wrench acquired.
Communications › Radio Communications › EPIRB
Issued 28 March 2018
Resolved
PWG01. Replace EPIRB Hydrostatic release. Operations are restricted to < 3nm until replaced. 46 CFR "New T" 180.64
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 2 April 2018
Resolution: replaced hydrostatic release
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 28 March 2018
Resolved
PWG02. Place a lifejacket light on all Type I PFDs. 46 CFR "New T" 180.75
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 2 April 2018
Fire Fighting › Fire Main › Material
Issued 28 March 2018
Resolved
PWG03 Place double hose clamps on flexible hose section on fire main. 46 CFR "Old T" 181.15-3
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 2 April 2018
Fire Fighting › Fire Main › Condition
Issued 28 March 2018
Resolved
PWG04 Place pressure gauge on fire pump outlet. 46 CFR "Old T" 181.10-1(c)
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 2 April 2018
Engineering › Fuel Oil Service System › Valve
Issued 28 March 2018
Resolved
PWG05 Place fuel cutoff valves at fuel tank for all machinery. 46 CFR 182.20-40(b)(3)
Action required: 705 - Other - as specified
Due 28 May 2018
Resolved 28 June 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 20 March 2017
Resolved
FCC Safety Radiotelephony Certificate Expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 31 March 2017
Documentation › Certificates/Documents › FCC SSL
Issued 20 March 2017
Resolved
FCC Station License Expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 31 March 2017
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 20 March 2017
Resolved
FCC Vessel Bridge-to-Bridge Certificate Expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 31 March 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 March 2017
Resolved
Provide most recent MIS report from Drug Consortium
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 5 April 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 March 2017
Resolved
Document and perform Man Overboard and Fire Drills. Document monthly test of EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 20 March 2017
Resolution: Corrected on the spot.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 March 2016
Resolved
Vessel must provide complete DAPI to include, company policy, after hours approved testing facility, and crew and supervisor drug awareness training. 46CFR16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 17 May 2016
Resolution: Vessel owner found company policy in Martitime handbook and recieved info on after hours testing.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 March 2016
Resolved
Vessle must provide means to lock MSD overboard discharge. 46CPR 184.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 28 March 2016
Resolution: Witnessed owner secure the MSD overboad discharge valve with stainless steel ring.
Navigation › Piloting/Steering › Marine Charts
Issued 24 March 2016
Resolved
Vessel must have updated charts. 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 17 May 2016
Resolution: New charts onboard.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 24 March 2016
Resolved
Ehaust pipe shall be gas tight and of sutiable construction. Cracked pipe and weld needs to be reparied. 46CFR182.15-20
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 17 May 2016
Resolution: Exhaust manifold has been replaced.