MAURY USCG vessel records
← All vessels

MISS FRANCES

MISS FRANCES is a 1976 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in June 2026, along with 58 deficiencies — 1 with no resolution recorded —, 1 operational control and 2 casualty investigations between 2018 and 2022.

Records from 2016 to 2026. Most recent: inspection, 1 June 2026.

Built
1976
Last inspected
1 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 June 2026
…with no type recorded3
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC5008
Flag
UNITED STATES
Maury page id
psix-48962

Documentation record

Registered dimensions (L × B × D)71.6 ft × 20.2 ft × 6.1 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1976
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPOINT JUDITH, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BEACH RUNNER Passenger (Uninspected) · MISLE 315654 · 4 August 2018 · activity 6500440USCGC LAWRENCE LAWSON (WPC 1120) Public Vessel, Unclassified · MISLE 1420169 · 4 August 2018 · activity 6500440

Inspection history · 21

1 June 2026 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8385517
26 August 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8217858
22 April 2025 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8112948
29 July 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7970319
27 March 2024 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7885975
26 September 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7797909
12 September 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7557151
12 September 2022 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7561932
30 April 2022 Damage Survey · Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7441221
30 April 2022 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7467311
1 June 2021 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7212343
15 March 2021 Deficiency Check · COI Inspection · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7149365
1 May 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6946788
24 February 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6914403
1 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6674442
4 August 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6500440
28 March 2018 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6379794
16 March 2018 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6373276
20 March 2017 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6106102
27 February 2017 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6097832
25 February 2016 Deficiency Check · DAPI Audit · Hull Examination · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5821610

Deficiency record · 58

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 August 2025 No resolution recorded
Provide and reconfigure Nav lights meeting UL 1104. To include Port and starboard side lights, fore mast and stern lights. P/S lights need to be remounted to provide Nav light screens behind them. Prior to operating at night or during periods of reduced visibility.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 August 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 August 2025 Resolved
Provide alcohol test strips.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2025
Resolved 27 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2025 Resolved
Provide current EPIRB NOAA registration. Prior to operating beyond 3 Nautical miles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 August 2025
Resolved 3 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 April 2025 Resolved
Grind out suspect crack in metal on stbd rudder for examination.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
Resolution: Ground down and not cracked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2025 Resolved
Replace PVC in bilge manifold piping with same metallic piping in remainder of system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
Resolution: Replaced with metallic.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2025 Resolved
Double hose clamp bilge manifold sea water valve and starboard exhaust raw water supply.
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 April 2025 Resolved
Install machinery belt guard for genset in centerline.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2025 Resolved
Replace wing nut on aux battery with permanent connection.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2025 Resolved
Remove dead end wire on aft engine room bulkhead and remove dead end wire on bulkhead forward of starboard engine.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 April 2025 Resolved
Properly secure starboard upper deck railing to support 200 pound point load.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2025
Resolved 9 May 2025
Resolution: Fabricated new footer securing points out of aluminum and installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 July 2024 Resolved
Needs fisheries endorsement
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2024
Resolved 22 August 2024
Resolution: After some research vessel does not need fisheries endorsement if it does not offload catch.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 July 2024 Resolved
Liferafts and paddles did not have name of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 July 2024 Resolved
EPIRB hydro date not marked
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2024 Resolved
Life ring vessel name worn off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2024 Resolved
Electrical wires in E/R need to be secured every 24"
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2024 Resolved
Twist off wire tires not allowed.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 29 July 2024 Resolved
Top deck front ladder needs to be marked with no pax allowed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 July 2024 Resolved
Remove excessive oil from engine room bilges. E/R bilge by the generator had approx 2" of black oil.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 July 2024 Resolved
E/R smoke detector was on the floor with the battery compartment open. Required it to be mounted and serviceable.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2024 Resolved
Dead end wires in E/R must be removed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2024
Resolved 29 August 2024
Resolution: Removed
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 29 July 2024 Resolved
Bilge manifold was not labeled.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 29 July 2024 Resolved
VHF radio had MMSI but did not have lat/long.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2024
Resolved 30 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2023 Resolved
Smoke detection systems not operating properly. The interconnectivity was not working.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2023
Resolved 26 September 2023
Resolution: Detectors properly connected while on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 September 2023 Resolved
Vessel failed to meet its inspection date and was restricted from operating until inspection complete.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2023
Resolved 26 September 2023
Resolution: Completed inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 September 2022 Resolved
Vessel had 04 [name withheld] PFDs that were recalled and not sufficient for maritime service. Lowered passenger count by four until PFDs replaced.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 4 January 2023
Resolution: Bought and installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 22 September 2022 Resolved
Vessel could not prove all crew were enrolled in a maritime consortium. Issued requirement to prove all vessel personnel enrolled.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: Provided proof
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 September 2022 Resolved
Vessel is required to have a properly mounted fire ax. The vessels fire ax was in a closet buried underneath items and took several minutes to find. Issued deficiency to mount fire ax.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: Mounted
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 22 September 2022 Resolved
Vessels AIS system did not work upon energizing system. Verified non-compliance through Marine Traffic.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 24 April 2023
Resolution: AIS displaying properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2022 Resolved
Vessels main fire pump did not work. Vessel was able to show use of auxiliary pump. Issued requirement to prove proper operation of vessels fire pump and to show proof of gauge at 60psi.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 4 January 2023
Resolution: O/O attests that fire pump is installed and operational.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 22 September 2022 Resolved
Vessel audible portion of the #3 tank high water alarm was inop. Issued requirement to fix it.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: Fixed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 September 2022 Resolved
Vessel is required to have current charts on board. Vessel is required to have a Coast Pilot on board. Vessel did not.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: On board
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 September 2022 Resolved
Vessel was missing items in the vessels first aid kit required by regulation. Specifically missing ammonia inhalants.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 23 September 2022
Resolution: Bought.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 September 2022 Resolved
Owner / operator shall schedule and successfully complete an annual inspection prior to the carriage of passengers as witnessed by the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2022
Resolved 22 September 2022
Resolution: Conducted annual inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022 Resolved
Cable and wiring required to be installed with metal support spaced not more than 24 inches apart IAW 46 CFR 183.340(b)(4).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022 Resolved
Electrical equipment must be bonded. In lazarette port side had non bonded wire IAW 46 CFR 183.372(a).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022 Resolved
Prevent electrical ignition of flammable vapor. In lazarette, light had missing plug to connection port IAW 46 CFR 183.200(d).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 June 2022 Resolved
Engine exhaust effectively insulated. Exhaust lagging on port inboard and starboard inboard exhaust pipes needs replaced up to cooling exhaust water IAW 46 CFR 182.425(b)(3).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 June 2022 Resolved
Provision must be made for closing all supply duct for space protected by a fixed gas extinguishing system. Vent to engine room (dog house) was not able to be fully closed IAW 46 CFR 182.465(h).
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 1 July 2022
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 April 2022 Resolved
Vessel ran aground damaging both props, rudders and stripping FRP warp from the keel and various places on the port side.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2022
Resolved 7 June 2022
Resolution: Repairs were completed to the satisfaction of attending MI.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 June 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2020 Resolved
Replace both port and stbd aft cutlass bearings
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2020
Resolved 5 March 2020
Resolution: Replaced port and stbd aft cutlass bearings
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2019 Resolved
Label number and size of life jackets in stowage containers located on the 2nd deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2019
Resolved 29 May 2019
Resolution: Labels afixed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 May 2019 Resolved
Remove DOT tape from life float and install approved SOLAS retroflective tape.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 29 May 2019
Resolution: SOLAS tape used
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2019 Resolved
Missing spanner wrench for fire plug
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 9 June 2020
Resolution: Spanner wrench acquired.
Communications › Radio Communications › EPIRB
Issued 28 March 2018 Resolved
PWG01. Replace EPIRB Hydrostatic release. Operations are restricted to < 3nm until replaced. 46 CFR "New T" 180.64
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 2 April 2018
Resolution: replaced hydrostatic release
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 28 March 2018 Resolved
PWG02. Place a lifejacket light on all Type I PFDs. 46 CFR "New T" 180.75
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 2 April 2018
Fire Fighting › Fire Main › Material
Issued 28 March 2018 Resolved
PWG03 Place double hose clamps on flexible hose section on fire main. 46 CFR "Old T" 181.15-3
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 2 April 2018
Fire Fighting › Fire Main › Condition
Issued 28 March 2018 Resolved
PWG04 Place pressure gauge on fire pump outlet. 46 CFR "Old T" 181.10-1(c)
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 2 April 2018
Engineering › Fuel Oil Service System › Valve
Issued 28 March 2018 Resolved
PWG05 Place fuel cutoff valves at fuel tank for all machinery. 46 CFR 182.20-40(b)(3)
Action required: 705 - Other - as specified
Due 28 May 2018
Resolved 28 June 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 20 March 2017 Resolved
FCC Safety Radiotelephony Certificate Expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 31 March 2017
Documentation › Certificates/Documents › FCC SSL
Issued 20 March 2017 Resolved
FCC Station License Expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 31 March 2017
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 20 March 2017 Resolved
FCC Vessel Bridge-to-Bridge Certificate Expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 31 March 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 March 2017 Resolved
Provide most recent MIS report from Drug Consortium
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 5 April 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 March 2017 Resolved
Document and perform Man Overboard and Fire Drills. Document monthly test of EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 20 March 2017
Resolution: Corrected on the spot.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 March 2016 Resolved
Vessel must provide complete DAPI to include, company policy, after hours approved testing facility, and crew and supervisor drug awareness training. 46CFR16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 17 May 2016
Resolution: Vessel owner found company policy in Martitime handbook and recieved info on after hours testing.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 March 2016 Resolved
Vessle must provide means to lock MSD overboard discharge. 46CPR 184.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 28 March 2016
Resolution: Witnessed owner secure the MSD overboad discharge valve with stainless steel ring.
Navigation › Piloting/Steering › Marine Charts
Issued 24 March 2016 Resolved
Vessel must have updated charts. 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 17 May 2016
Resolution: New charts onboard.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 24 March 2016 Resolved
Ehaust pipe shall be gas tight and of sutiable construction. Cracked pipe and weld needs to be reparied. 46CFR182.15-20
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 17 May 2016
Resolution: Exhaust manifold has been replaced.

Casualty record · 2

4 August 2018Routine · role: Transiting Vicinity of Primary Subject · activity 6500440
30 April 2022Routine · role: Involved in a Marine Casualty · activity 7467311
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

PORGY IV (2018), PECONIC STAR III (2022). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.