Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 June 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WZC8518
Flag
UNITED STATES
Maury page id
psix-48963

Documentation record

Registered dimensions (L × B × D)154.1 ft × 32.0 ft × 5.8 ft
Registered tonnagegross 99 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMPBELL INDUSTRIES · SAN DIEGO, CA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLARKSPUR, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 3 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 37 inspections, each with its date, unit and type; 51 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 37

10 June 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8397815
2 February 2026 Drydock Exam · Deficiency Check · Internal Structural Exam · Vessel Attendance
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8304613
21 October 2025 Internal Structural Exam · COI Inspection · Vessel Attendance · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8249671
10 March 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8091814
6 March 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8089391
30 January 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8072566
20 February 2024 Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7867923
17 October 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7809543
20 April 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7672562
6 December 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7604413
28 November 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7600715
23 June 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7486111
23 May 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7457473
5 March 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7407320
3 March 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7405905
11 February 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7395022
3 February 2022 Deficiency Check · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7390254
2 February 2022 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7389915
9 December 2021 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7356158
27 November 2020 Deficiency Check · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7102561
8 June 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6971566
2 March 2020 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6919317
5 February 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6944525
25 November 2019 Inclining Experiment · Internal Structural Exam · In-Service Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6862028
26 September 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6821905
18 June 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6717621
18 June 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6720209
9 January 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6608223
21 June 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6452803
9 February 2018 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6558847
8 February 2018 Drydock Exam · Plan Review (Other than "T") · Examination of Repairs · Annual Inspection · Deficiency Check · Inclining Experiment · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6362136
11 December 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6322271
4 December 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6318107
1 March 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6097279
29 November 2016 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6049150
28 March 2016 Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5848023
19 February 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5818578

Deficiency record · 51

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. The sensor alarm panel on the bridge was not displaying the second engine monitoring screen. 46 CFR 120.200 (a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 16 June 2026
Resolution: Did a system hard reboot and all systems functioning normal.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2025 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant OCMI. Marine Inspector identified the piping for the fire pump discharge on the port side had corrosion build up and requires cleaning for further assessment. (46 CFR 119.700)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 23 March 2026
Resolution: Observed satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2025 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Marine Inspector identified the engine room starboard aft fire damper was unable to fully close. (46 CFR 118.410(b)(10))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 4 November 2025
Resolution: Received work report attesting to functional fire dampers being able to close properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2025 Resolved
Water for cooling an exhaust pipe, other than a vertical exhaust, must be injected into the exhaust system as near to the engine manifold as practicable. The water must pass through the entire length of the exhaust pipe. Marine Inspector identified flexilbe hose connected to port main engine muffler was leaking small amount of water at high RPMs where the hose to muffler fitting was connected. (46 CFR 119.425(b)(3))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 17 March 2026
Resolution: Muffler and hose replaced during drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 October 2025 Resolved
Each ring life buoy on a vessel must be readily accessible. Marine Inspector observed that each life ring was missing retroreflective tapes. (46 CFR 117.70 (b)(2))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 4 November 2025
Resolution: Received satisfactory photos of retro tape on life rings.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 October 2025 Resolved
The fire detection and alarm system must be so arranged and installed that the presence of a fire in any of the protected spaces will be automatically registered visibly and audibly in the pilothouse. MI identified an error on the fire detection panel during op testing; both port and starboard display as starboard. (46 CFR 115.810(a)(7))
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 March 2026
Resolution: Observed satisfactory repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 October 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel ... giving consideration to provisions for a seaworthy hull ... and necessary facilities for passengers and crew. Marine Inspector observed and marked 07 cracked welds in void spaces and discussed their locations with the operator. (46 CFR 116.100(a))
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 March 2026
Resolution: Verified repaired welds.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 March 2025 Resolved
Vessels… carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H. Doors in “A” class bulkheads shall… have a latch with a minimum throw of ¾ inch. Installed latch mechanism on the forward lounge doors identified malfunctioning on the bottom and without proper upper latch catch. 46 CFR 177.10-5(a) 46 CFR 72.05-25(b)(3) (OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 1 May 2025
Resolution: Operator replaced latches on the fire screen doors and demonstrated operation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 March 2025 Resolved
The fire detection and alarm system must be so arranged and installed that the presence of a fire in any of the protected spaces will be automatically registered visibly and audibly in the pilothouse. MI identified an error on the fire detection panel during op testing. 46 CFR 115.810(a)(7)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 24 March 2025
Resolution: Vessel provided documentation that a technician had confirmed that there was no error in the system, as the system had recently been serviced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 March 2025 Resolved
Vessels… carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H. Doors in “A” class bulkheads shall… be of hollow steel or equivalent metal construction. Identified holes in multiple onboard doors in “A” class bulkheads. 46 CFR 177.10-5(a) 46 CFR 72.05-25(b)(1) (OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 22 April 2025
Resolution: Observed that doors throughout vessel were properly plugged.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 March 2025 Resolved
Vessels… carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H. Doors in “A” class bulkheads shall… meet the following requirements: Rugs and carpets shall not pass through doorways, but linoleum and similar coverings may do so. Forward main deck stairway doors found with carpet passing beneath. 46 CFR 177.10-5(a) 46 CFR 72.05-25(b)(6) (OLD T)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 24 March 2025
Resolution: Vessel provided photographic evidence showing that proper repairs were made to remove carpet from passing between door passageways.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 10 March 2025 Resolved
At each ... inspection for certification, the marine inspector shall view the vessel afloat and shall ...Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. Marine Inspector identified that the sewage overboard piping was deteriorated. Conduct repairs to the satisfaction of the attending MI at the next dry-dock. 46 CFR 176.25-5(a)(1) OLD T
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2026
Resolution: Condition of piping found satisfactory and did not require repair.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2025 Resolved
Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Marine Inspector identified that the CO2 Placards required for protected spaces was missing on the exteriors of the port and starboard CO2 storage spaces, and Engine Room. Add safety placards to the exterior entry points of each CO2 storage and protected space to the satisfaction of the attending Marine Inspector. 46 CFR 122.612(i)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 22 April 2025
Resolution: Observed proper installation of CO2 placard on all doors, specifically engine room door, which was not previously photographed by vessel operator.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2025 Resolved
All electrical equipment and circuits must be clearly marked and identified. Marine Inspector identified that various distribution panels on board did not properly identify "spare" breakers which appeared to be in use. 46 CFR 120.220(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 24 March 2025
Resolution: Operator provided photographic evidence of properly identified spares on breaker panels.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2025 Resolved
Each... ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Marine Inspector identified that the ring life buoys located on the sun deck did not clearly mark vessel's name. 46 CFR 122.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 24 March 2025
Resolution: Operator provided photographic evidence of corrected ring life buoy markings.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 March 2025 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not complete annual inspection within the alloted time frame. Conduct satisfactory annual inspection to the satisfaction of the MI prior to the carriage of passengers. 46 CFR 115.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2025
Resolution: Vessel completed satisfactory annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2025 Resolved
..Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel's reduction gear box cooler failed. Prior to the carriage of passengers, carry out gear box cooler repairs and conduct internal sea trials to the satisfaction of the MI. 46 CFR 119.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2025
Resolution: Cooler was replaced and sat op tests were conducted.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 October 2023 Resolved
A door (A-Class fire control boundaries) must be of self-closing type capable of closing against a 3.5 degree list of the vessel. During inspection, fire service door at midhsips, port side, would not latch closed when activated from the control space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2023
Resolved 21 November 2023
Resolution: Door latch fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2023 Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 6 inches (15.2 centimeters) above the deepest subdivision load line must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Vessel is equipped with drip-less shaft seals. During inspection, Marine Inspector found that port shaft seal had slipped underneath the tensioning device. Engineers were able to replace tensioning device and repair the shaft seal installation to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2023
Resolved 17 October 2023
Resolution: Engineers were able to replace tensioning device and repair the shaft seal installation to the satisfaction of the attending Marine Inspector during annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 October 2023 Resolved
Each rescue boat and ring life buoy must be marked with Type II retro reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Life buoys on the upped deck, port and starboard have worn retro reflective tape that needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2023
Resolved 21 November 2023
Resolution: Reflective tape replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 October 2023 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. There is a unterminated electrical wire passing through frame 45 that must be removed and the cable pass through sealed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2023
Resolved 21 November 2023
Resolution: Unterminated wire removed and bulkhead penetration sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 October 2023 Resolved
Exhaust gas must not leak from the piping or any connections. There is an exhaust leak from the turbo on the port main engine.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2023
Resolved 21 November 2023
Resolution: Turbo mounting studs replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 October 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. There is a crack under a Tank Support, forward of frame #47, Longitudinal Frame, port side, keel that needs repair.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 21 March 2024
Resolution: Verified weld repair.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 October 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. The hull is pitted from corrosion in the following locations: Under Strainer Bucket Void. Portside, between frames 14 and 15. Between frames 33 and 36, centerline. Between frames 24 and 25, stbd, centerline
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 8 April 2024
Resolution: Verified hull inserts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 October 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Second deck port Balcony Support has been damaged and must be repaired.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 21 March 2024
Resolution: Verified balcony support repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 December 2022 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Leaking bilge pipe in port fuel tank must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 16 December 2022
Resolution: Provided satisfactory photographs of repair.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 December 2022 Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard and, if accessible from the rear, on the deck in the rear of the switchboard. Nonconducting mats must be provided in the starboard false stack compartment and E/R switchboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 16 December 2022
Resolution: Received satisfactory photographs of non-conducting mats.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 December 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Condense kits and expired items must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 19 December 2022
Resolution: Received satisfactory photograph of first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 December 2022 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Port main deck outdoor light is missing its bulb and protective cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 16 December 2022
Resolution: Received satisfactory photograph of repaired light fixture.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 23 May 2022 Resolved
Fuel oil found in engine room bilge pocket. Remove and clean area.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 June 2022
Resolved 17 June 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2022 Resolved
SWBD panel not properly sealed; motor controller (MC) for Generator breaker missing. Provide temporary seal over MC till spare part becomes available and make permanent repairs.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2022
Resolved 24 June 2022
Resolution: Vessel rep replaced missing motor controller for generator breaker. Sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2022 Resolved
Engine room entry fire extinguisher missing from storage bracket. Locate and install fire extinguisher.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 17 June 2022
Resolved 17 June 2022
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 March 2022 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel experienced starboard engine transmission failure.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2022
Resolution: Verified proper repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 December 2021 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Inspection of all fuel systems; Substantial fuel leak found on outboard side of port engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 December 2021
Resolved 10 December 2021
Resolution: Failed o-rings on two fuel injectors on port ME found and replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 December 2021 Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Missing insulation found on fire boundary bulkhead on forward side of engine room. Correct by the next credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 3 February 2022
Resolution: Verified newly installed fire insulation through photos.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 9 December 2021 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel window on main deck port bow missing with temporary repair in place. Correct by next credit drydock
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 29 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 December 2021 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each life jacket, work vest, and marine buoyant device. Two life jackets require renewed retro reflective tape and one life jacket found with large tear at the base.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 9 January 2022
Resolution: Operator replaced damaged life jackets with new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 December 2020 Resolved
Each survival craft must be secured to the vessel by a painter with a float free link permanently attchaed to the vessel. Manual release mechanism impedes operation of hydrostatic release. Arrangement shall be made to insure all hydrostatic releases are fully operational independently prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2020
Resolution: Attached photos of the survival craft manual release mechanism on all vessel life rafts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2020 Resolved
Each life jacket must be marked with Type 1 retroflective material. 107 adult and 28 children life jackets with worn and non operational reflective tape. Replace with new reflective tape.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2020
Resolved 15 December 2020
Resolution: Maintenance Deck Hands replaced or repaired all life jackets lacking reflective tape or having seized buckles.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 November 2020 Resolved
Each vessel must have adaquete emergency lighting fitted along the line of escape to the main deck from passenger accomodation spaces. 02 emergency lights inoperable. Replace in-kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2020
Resolved 17 December 2020
Resolution: Maintenance Mechanics replaced two (2) burned out emergency lights on the main deck.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 November 2020 Resolved
Fire control boundary must be constructed and capable of preventing the passage of smoke and flame for one hour. MI observed three holes that penetrated through A60 door fwd port.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2020
Resolved 18 December 2020
Resolution: Two (2) A60 doors on the upper deck had holes where a previous style of door closure was installed. Maintenance Mechanics installed Nutsert fasteners to plug the existing holes and replaced a missing cover over one of the door closures.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 March 2020 Resolved
Penetrations in A-Class fire control boundaries for electrical cables must be constructed to prevent the passage of flame and smoke for one hour. HVAC room on upper deck is listed as an A-0 boundary and has a multi-cable transit (MCT) without fire protection installed. Install proper fire protection in MCT. 46 CFR 116.415(a)(2)(ii)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2020
Resolved 9 April 2020
Resolution: Accepted photo for MCT installation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 March 2020 Resolved
A-Class bulkheads must be composed of steel or equivalent material. In addition, they must be so insulated with approved structural insulation. Forward aluminum bulkhead in HVAC room on upper deck is listed as A-0 but is not fitted with insulation. Utility closet (A-0) on upper deck is also missing insulation on two bulkheads. Install proper insulation for both spaces to meet A-0 standard prior to next credit drydock. 46 CFR 116.415(a)(2)(i)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 13 January 2022
Resolution: Operator successfully installed insulation on bulkheads.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 February 2020 Resolved
The cognizant Officer in Charge, Marine Inspection (OCMI) determines the total number of persons permitted to be carried on a vessel. The vessel is restricted to operating with a reduction of 150 passengers, with an additional limitation of 50 passengers maximum allowed on the uppermost (Sun) deck. The total number of passengers allowed on the vessel is 600. This restriction will be lifted upon successful completion of a Stability Test and receipt of an approved Stability Letter by the USCG Marine Safety Center. 46 CFR 115.112
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 8 June 2020
Resolution: Approved stability letter recieved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 November 2018 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. All portable fire extinguishers onboard were overdue for servicing. Service portable fire extinguishers and provide documentation prior to carrying passengers. 46 CFR 115.810(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2018
Resolved 2 November 2018
Resolution: Global Fire attended vessel, serviced all portable fire extinguishers and provided documentation.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 1 November 2018 Resolved
When in accordance with 170.120 in subchapter S of this chapter, a vessel must be provided with a stability letter. Vessel does not have an updated stability letter from recent incline test that was completed. Provide approved stability letter prior to carrying passengers. 46 CFR 115.306
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2018
Resolved 15 November 2018
Resolution: Stability letter provided.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 November 2018 Resolved
Double doors capable of independent operation and latching may have a clearance between the doors of not more than 3.2 millimeters. However, if one door must always be closed first, means shall be provided to ensure that the doors close in the proper order. Self closing doors on starboard side main separating accommodation spaces would not fully close. Prove proper closure of doors. 46 CFR 116.435(b)(5)(i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 2 November 2018
Resolution: Shipyard adjusted doors and demonstrated proper closure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2018 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter. Starboard Sun Deck life buoy has faded vessel name lettering and wasted retroreflective tape. Main Deck life buoy outer material is peeling from the main body. Repair or replace life buoys. 46 CFR 117.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 16 November 2018
Resolution: Recieved photos for corrected life buoys.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 1 November 2018 Resolved
A fire control plan (FCP) must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. FCP not posted on Sun Deck and Upper Deck IAW shipboard FCP. Current FCP does not list compartment titles and structural fire protection boundaries. Update FCP and post in designated locations. 46 CFR 116.530
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 11 February 2019
Resolution: Verified corrected FCP onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 November 2018 Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel did not have FCC Station License onboard. Provide valid station license. 47 CFR 80.13(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 2 November 2018
Resolution: Operators provided valid copy of station license.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 February 2016 Resolved
Propeller has a crack in the blade root of one of the 5 propeller blades. The crack was reported as being approximately 75% of the blade length opened up to about 1/8” gap. Operator voluntarily taking boat out of service and vessel needs to complete drydock prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2016
Resolved 4 April 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.