Documentation record
Registered dimensions (L × B × D)28.0 ft × 10.0 ft × 8.0 ft
Registered tonnagegross 15 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPREMIUM PARASAIL BOATS · CAPE CORAL, FL, UNITED STATES · built 1999
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portDUCK, NC
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 6 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2018
Resolved
An exposed hazard, such as rotating machinery, must be properly protected by a cover, guard, or rail. Provide guard on rotating machinery to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 177.960)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2018
Resolved 23 October 2018
Resolution: Placed guard over rotating machinery hazard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 October 2018
Resolved
Shutoff valves installed so as to close against fuel flow. Replace handle to fuel shutoff vavle to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 182.455(b)(4))
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2018
Resolved 23 October 2018
Resolution: Replaced handle to operate emergency fuel shutoff valve efficiently.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 October 2018
Resolved
A visual and audible alarm must be provided at the operating station. Provide visual alarm to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 182.530(a))
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2018
Resolved 23 October 2018
Resolution: Repaired bilge high level alarm system to display both visual and audible alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2018
Resolved
The number and identification of the items stowed inside and their sizes, must be marked in clearly legible letters and numbers. Provide two more adult life jackets or re-label the number to accommodate actual number of life jackets currently on board. (46 CFR 185.604(f))
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2018
Resolved 23 October 2018
Resolution: Added two addition adult life jackets to accommodate total number they have on board the vessel.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 October 2018
Resolved
Abandon ship, man overboard, and fire drills and training shall be logged or otherwise documented. Operator shall conduct and log drills and training. (46 CFR 185.520(f) and 46 CFR 185.524(d))
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2018
Resolved 23 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 October 2018
Resolved
Vessel must carry adequate and up-to-date charts. Provide updated charts to the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2018
Resolved 23 October 2018
Resolution: Replaced old charts.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 September 2017
Resolved
Vessel's Radio Safety Certificate has expired. Have radio equipment re-certified by an FCC inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 4 October 2017
Resolution: Vessel rep provided a current Radio Safety Certificate for the SKY KING.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 September 2017
Resolved
Navigation lights were found to be inoperable. Repair lights to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 4 October 2017
Resolution: Vessel operator installed enw navigation lights. Vessel's navigation lights were tested and found to be operational.
Engineering › Fuel Oil Service System › Valve
Issued 18 September 2017
Resolved
Emergency shutoff valve at the fuel tank does not completely secure. Repair to the satisfcation of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2017
Resolved 4 October 2017
Resolution: Vessel's fuel supply shutoff was repaired and an operational test indicated satisfactory function.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 September 2017
Resolved
The flexible discharge hose for the vessel's hydraulic oil cooler is deteriorated. Renew flexible hose in accordance with SAE J-1942 and J-1475 as required for flexible hoses and fittings used in vital fluid power systems.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2017
Resolved 4 October 2017
Resolution: Overboard discharge line has been replaced in kind.
Fire Fighting › Ventilation Systems › Ducts
Issued 18 September 2017
Resolved
Engine compartment blower ventilation ducting and torn engine air supply ducting prevent the engine compartment from becoming gas tight for the purposes of firefighting. Make engine compartment gas tight as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2017
Resolved 4 October 2017
Resolution: All engine compartment ventilation ducting had been repaired and engine compartment made gas tight.
Stability › Watertight Integrity › General
Issued 18 September 2017
Resolved
Through-hull penetration for the vessel's hydraulic oil cooler does not have a shutoff valve located at the hull penetration. Install a positive action valve at the hull penetration prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2017
Resolved 4 October 2017
Resolution: Vessel rep had installed a shutoff valve for the cooler at the hull penetration as required.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2017
Resolved
Dead end wires found in the engine compartment. Remove dead end wires to the satisaction of the CG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 4 October 2017
Resolution: Dead end wires have been removed from the engine compartment as required.
Engineering › Bilge Water Management System › Pump
Issued 18 September 2017
Resolved
Discovered vessel has no visual indicators for bilge pump operation. Install visual indicators at the operating station to show operation of individual bilge pumps.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2017
Resolved 4 October 2017
Resolution: Visual indicators for bilge pumps were installed at the operating station. Testing of the bilge pump indicators was conducted for verification; all sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 October 2016
Resolved
Found Anchor Light Cracked. Replace Anchor Light to the satisfaction of the attending CGMI.
Action required: 705 - Other - as specified
Due 17 October 2016
Resolved 5 June 2017
Resolution: Operator Installed new Anchor Light; All Sat.