← All vessels
TEN III
TEN III is a 1997 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 2001, most recently in March 2026, along with 111 deficiencies and 2 operational controls.
Records from 2001 to 2026. Most recent: inspection, 2 March 2026.
- Built
- 1997
- Last inspected
- 2 March 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 111 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
WDG2656
489710
Flag
UNITED STATES
—
Maury page id
psix-489710
Inspections, by type
…with no type recorded5
Years with a record
23 calendar years (2001–2026)
The 49 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
5 - Regulatory (Subpart C or D), Net Ton
5 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 49
2 March 2026
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8318299
10 December 2025
Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8280263
30 April 2025
Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8127072
16 December 2024
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8047772
25 November 2024
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8038889
16 January 2024
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7849548
19 April 2023
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7670612
17 January 2023
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7622083
22 November 2021
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7358301
21 October 2021
Deficiency Check · Re-Inspection · Administrative Inspection · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7337493
6 April 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7189685
14 December 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7118037
31 March 2020
Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6933885
14 May 2019
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6683572
13 April 2019
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6671424
28 December 2018
Administrative Inspection · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6605022
6 March 2018
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6605433
28 January 2017
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6083777
15 December 2016
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6083776
13 January 2016
Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5791727
6 January 2016
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5792634
28 May 2014
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4871825
8 May 2014
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4852964
13 February 2012
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4243101
2 February 2012
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4236457
29 January 2012
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 4233756
19 September 2011
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4148658
4 February 2011
COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3936889
30 November 2010
Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3900664
5 March 2010
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3695730
16 February 2010
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3680244
24 March 2009
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 3438898
17 March 2009
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3434661
19 November 2008
Hull Examination · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3372425
19 March 2008
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3167147
13 September 2007
Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 3082806
7 March 2007
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2883174
4 September 2006
Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 2775920
31 May 2006
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2665545
3 May 2006
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2685500
7 February 2006
Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2580439
8 March 2005
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2305357
19 November 2004
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2244129
9 February 2004
Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2002698
21 February 2003
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1747294
15 November 2002
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1705217
27 February 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1489604
5 February 2002
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1482506
15 February 2001
MARPOL Annex V Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1373227
Deficiency record · 111
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
04 Adult life jackets and 04 child life jackets were found damaged and unserviceable. Replace as need. Total person on board count reduced to 22.
46 CFR 180.71(a)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 December 2025
Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— six(06) hand red flare distress signals and six(06) hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
Distress flares are expired. Replace.
46 CFR 180.68(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 December 2025
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel.
Port holes in the cabin are damaged, replace in kind.
46 CFR 177.1020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 November 2024
Resolved
Forward compartment bilge high water level visual and audible alarm is inoperable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 November 2024
Resolved
Ring buoy's retro-reflective tape is worn.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 November 2024
Resolved
The port and stbd side lights are not mounted correctly to meet the required range of degree. In addition, the all around anchor light is inoperable. Vessel is restricted to day light operations.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 November 2024
Resolved
Four red distress signals are expired. Vessel is restricted to day time operations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 January 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The port main engine start switch was intermittently functioning. 46 CFR 182.100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2023
Resolved
Tighten loose port engine mount bolt.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2021
Resolved
Waste receptacles must be constructed of non-combustible materials with no openings in the sides or bottom. Replace missing receptacle and maintain on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Wipe clean all lifejackets and replace deteriorated reflective tape with new. Remove lifejackets marked with different vessel names other than TEN III must be removed off the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2021
Resolved
Missing sign for upper deck prohibiting passengers from being carried on upper deck. Replace sign on both sides of ladder leading to upper deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 October 2021
Resolved
Per cite, sufficient ventilation for machinery cooling is available. Repair port and starboard ventilation covers to stay open in order to allow natural air to flow into the engine room space when mains are operating. Replace missing hook or hold back.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 October 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication and Coast Guard Light List. Vessel missing U.S. Coast Pilot and Light List. Replace with new and maintain on board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2021
Resolved
All escape hatches and other emergency exists used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: EMERGENCY EXIT, KEEP CLEAR”.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 21 October 2021
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Update vessel’s call sign on placard.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 October 2021
Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to the mounted at the primary operating station. Repair compass and prove operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 October 2021
Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose, which do not rely on the spring tension of the clamp for compression force and are installed beyond the bead or flare. Replace missing second hose clamp on electrical submersible pump in forward void. Ensure all spaces with electrical submersible pump are double clamped on both ends.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 October 2021
Resolved
A hatch exposed to the weather must be weather tight. Remove debris for proper drainage to overboard.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 21 October 2021
Resolved
Replace missing placard near MSD overboard valve prohibited discharge of sewage within 3 miles from shore.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2021
Resolved
Repair overhead insulation in engine room to the satisfaction of the USCG MI.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 October 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Repair and prove operation of forward cabin lights and fan to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 October 2021
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. Portable fire extinguishers stowed away in forward cabin and not at designated locations in approved brackets. Relocate extinguishers at locations required where it is clearly visible and location marked.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 June 2021
Resolved
46 CFR 183.420: All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Prove proper operation of anchor and navigational lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021
Resolved
46 CFR 182.720(e)(3)(v)(B): Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose, which do not rely on the spring tension of the clamp for compression force and are installed beyond the bead or flare. Replace missing second hose clamp on electrical submersible pump in engine room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 June 2021
Resolved
46 CFR 179.360: A hatch exposed to the weather must be watertight. Replace gasket on stbd engine room hatch cover on main deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2021
Resolved
46 CFR 182.100: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Replace missing shutoff handle to stbd water pump valve in engine room and stbd overboard valve to as original design.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2021
Resolved
46 CFR 182.100: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Properly reconnect grounding wires in engine room for main engines and auxiliary machinery.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 June 2021
Resolved
46 CFR 183.340(b)(4) All cable and wire must be installed with a metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Properly install electrical cables and replace missing chaffing guard on wire hangars throughought vessel's internals.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 December 2020
Resolved
46 CFR 176.600: A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination an an internal structural at least once every two years. The owner has informed USCG that the required drydock examination will not be conducted prior to the due date. Vessel is restricted from carrying passengers for hire until a credit drydock examination has been completed to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2020
Resolved
46 CFR 185.520(a): Redo man overboard drills to the satisfaction of the attending USCG Marine Inspector before carrying passengers for hire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2020
Resolved
46 CFR 182.720(e)(3)(v)(B): Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose, which do not rely on the spring tension of the clamp for compression force and are installed beyond the bead or flare. Replace missing second hose clamp on electrical submersible pump in forward void.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2020
Resolved
46 CFR 184.710: A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents. Replace missing required items and expired medicines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 July 2020
Resolved
46 CFR 182.100: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Replace leaking hose for shaft cooling system with new at upcoming dry dock in December 2020.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 16 July 2020
Resolved
46 CFR 182.610(b): Control of the main steering gear, including control of any necessary associated devices (motor, pump, valve, etc.) must be provided from the operating station. Vessel's secondary operating station for steering located above the main deck is inoperable. Repair and prove operation of steering, shifter and throttle at upcoming dry dock in December 2020. Vessel's primary means of steering on main deck is still operational and functions as intended.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 14 May 2019
Resolved
Any vessel of at least five net tons which engages in Coastwise trade, must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel's net tonnage is 5, and engages in Coastwise trade as defined in 46 CFR 67.3 and 67.19. Vessel must carry a valid Certificate of Documentation in accordance with cite while carrying passengers for hire in U.S. waters. Vessel may also apply for Registry endorsement per 46 CFR 67.17.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2019
Resolved
Replace reflective tape on adult and child life jackets with new; remove mold and dirt from adult and child life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 April 2019
Resolved
Replace expired hydrostatic release for EPIRB with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2019
Resolved
Post sign to show where adult and life jackets are stowed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 April 2019
Resolved
Remark faded sign for engine room natural ventilation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2019
Resolved
Replace life ring with original and replace grab line on life ring with USCG marine approved type.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 April 2019
Resolved
Replace missing heat shield/insulation on engine room hatch covers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 April 2019
Resolved
Replace gasket with new and for marine use on aft steering hatch cover.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 April 2019
Resolved
Program vessel's MMSI number into VHF radio and include MMSI number of other owned vessels including USCG's Command Center.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2019
Resolved
Replace missing thimble on anchor line.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2019
Resolved
Mark words for emergency exit in red: Emergency Exit Do no Block.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2018
Resolved
Mark in 2" block letters vessel Name and homeport on ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2018
Resolved
Replace missing detachable clip on line attached to ring buoyant light.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 March 2018
Resolved
Show proof of working light for compass.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 March 2018
Resolved
Vessel is required to have 6 red and 6 orange for Limited Coastwise or 12 combination flares for night and day use.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2018
Resolved
Replace 2 gallon fire buckets with 2.5 gallon buckets. Must be marked with vessel name and lanyard attached.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 March 2018
Resolved
Replace missing reflective tape on ring buoy with new.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 March 2018
Resolved
Vessel log book must be maintained on board and monthly tests conducted for EPIRB. Vessel owner/operator required to ensure monthly tests are done regardless if vessel is not in service during slow periods. Failure to conduct monthly tests will result in a potential enforcement action. In addition, vessel owner will start documenting drills, EPIRB tests and inspection of lifesaving equipment on a monthly basis. Effective immediately.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 March 2018
Resolved
Replace wasted reflective tapes on life jackets for both adults and children. Life jackets must be maintained in serviceable condition and stored in a clean and dry location.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2017
Resolved
Secure diesel fuel leak on top of the engine and make proper repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2017
Resolved
Secure oil leak and make proper repair to port side engine breather.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 28 January 2017
Resolved
Complete repairs to port side cabin window with missing screws.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 January 2017
Resolved
Make proper repairs to overhead lights in engine room compartment.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 28 January 2017
Resolved
Make proper repair to starboard side throttle at operator station.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 28 January 2017
Resolved
Replace missing vessel call sign at operator station.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2017
Resolved
Install metal hangers every 24" to secure wires/cables in engine room compartment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2017
Resolved
Remove 600V marine grade cable no longer in use inside the engine room compartment, starboard side or show proof that the conductors are properly capped on both ends.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 13 January 2016
Resolved
Make proper repairs to deteriorated fire insulation in the engineroom.
Engineering › Fuel Oil Service System › Hose
Issued 13 January 2016
Resolved
Replace all non-approved fuel hose with approved fuel hose, i.e. SAE J-1942 or equivalent.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 January 2016
Resolved
Ensure all licensed personnel and those in safety sensitive positions are enrolled in a drug testing program.
Lifesaving › Lifefloat › Serviceable
Issued 13 January 2016
Resolved
Promary lifesaving, i.e. lifefloat, is in poor condition and is not serviceable. Route restricted to not more than 3 miles from shore.
Lifesaving › Lifefloat › Approval
Issued 7 January 2016
Resolved
Requirements for Out of Water Survival Craft and replacement of Life Floats and Rigid Buoyant Apparatus. See Special Note for guidance and timelines.
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 May 2014
Resolved
Provide updated US Coast Pilot [name withheld] and radio broadcast placard.
Lifesaving › Lifebuoys › Serviceable
Issued 8 May 2014
Resolved
Replace ring buoy (24" with retro and name).
Communications › Radio Communications › EPIRB
Issued 8 May 2014
Resolved
Renew EPIRB battery.
Communications › Radio Communications › EPIRB
Issued 8 May 2014
Resolved
Renew EPIRB hdrostatic release.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 8 May 2014
Resolved
Secure sewage overboard valve (zip tie or lock)
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 May 2014
Resolved
Repair anchor light.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 May 2014
Resolved
Provide tamper seal for fireboy manual pull.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 May 2014
Resolved
Update FCC Safety Radio Certificate with new call sign.
Electrical › Electrical Distribution System (service) › Cable
Issued 8 May 2014
Resolved
Repair bonding wire in steering space.
Stability › Watertight Integrity › General
Issued 30 November 2010
Resolved
Port side shaft log dripless boot loose. Repair/replace to as new condition and replace broken hose clamp. Complete prior to credit drydock.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 30 November 2010
Resolved
Port side propeller cracked and corroded. Replace as new. Correct prior to credit drydock.
Construction/Loadline › Hull › Hull Plating
Issued 30 November 2010
Resolved
Repair/replace FRP delamination around struts and lazarette on starboard side. Complete prior to credit drydock.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 30 November 2010
Resolved
Forward watertight deck hatch, repair/replace watertight gasket as necessary. Complete prior to credit drydock.
Stability › Watertight Integrity › General
Issued 30 November 2010
Resolved
Repair leaks in main deck over forward portion of lazarette, port side. Complete prior to credit drydock.
Construction/Loadline › Penetrations › Valve Flange
Issued 30 November 2010
Resolved
Pull for examination 2 valves on starboard machinery space (bilge valves). Valves seized, repair/replace as necessary. Complete prior to credit drydock.
Construction/Loadline › Hull › Bottom Plating
Issued 30 November 2010
Resolved
Repair area of damaged mat/woven (dry) in vicinity of port mid strut/shaft. Complete prior to credit drydock.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 16 February 2010
Resolved
Per mfr, alcohol test kits onboard must be stored at temps <80 deg F, which is impractable in Guam for vsl stowage. Explain and/or provide means to comply with post casualty 2hr alcohol testing requirements.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 February 2010
Resolved
Service B-1 portable fire ext.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 16 February 2010
Resolved
Update emergency broadcast placard with current call sign.
Operations/Management › Passenger Operations › Safety Orientation
Issued 16 February 2010
Resolved
Provide means to ensure passenger safety brief is understood by passengers. (language issue)
Operations/Management › Drug and Alcohol Testing › Collection Sites
Issued 16 February 2010
Resolved
Ensure drug testing program has means to comply with 32hr post casualty drug testing requirements (i.e. collection facility only open M-F, yet vsl operates M-Su)
Documentation › Certificates/Documents › FCC SSL
Issued 17 March 2009
Resolved
Update/correct FCC Station Lic to reflect compulsory equipped (SB).
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 March 2009
Resolved
Provide current Coast Pilot and Light List or excerpts for areas operated.
Construction/Loadline › Structures › Ventilators
Issued 17 March 2009
Resolved
Free-up stuck remote vent closures for machinery space vents.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 2 December 2008
Resolved
Replace plastic hose on connections below the waterline with HD marine grade hose for use below waterline.
Construction/Loadline › Structures › Deck Plating
Issued 2 December 2008
Resolved
Repair leak on deck, portside aft outboard, near fuel fill.
Construction/Loadline › Structures › Superstructure
Issued 19 November 2008
Resolved
Ensure portlights (above main deck) are water tight.
Construction/Loadline › Structures › Scuttle
Issued 19 November 2008
Resolved
Replace cracked hatch, fwd cabin. Ensure watertight.
Construction/Loadline › Penetrations › Valve Flange
Issued 19 November 2008
Resolved
Replace plastic thru hull fittings with metallic.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 19 November 2008
Resolved
Repair fractures on engine mounts, stbd inboard aft, port inboard aft and fwd.
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 November 2008
Resolved
Replace rotted plywood for machinery space vents where needed with marine grade plywood.
Construction/Loadline › Structures › Deck Plating
Issued 19 November 2008
Resolved
Repair/seal leak on deck, portside overhead fwd in machinery space.
Construction/Loadline › Hull › Hull Plating
Issued 19 November 2008
Resolved
For credit hull exam. Make vsl available for inspection once back in the water
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 March 2008
Resolved
Stern light not working.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 March 2008
Resolved
Compass light needs to be repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 19 March 2008
Resolved
Tourqe down port mde fwd engine mount.
Engineering › Sea-water System (primary cooling) › Valve
Issued 19 March 2008
Resolved
Free stbd MDE sea suction valve.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 19 March 2008
Resolved
Repair or replace gauge panel so the gauges can be read. Sun bleached making it difficult to read gauges.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 March 2007
Resolved
Seperate adult and child lifejackets.
Operations/Management › Drills/Instruction › Fire
Issued 7 March 2007
Resolved
Provide proof of fire drills in log book.
Documentation › Certificates/Documents › FCC SSL
Issued 7 February 2006
Resolved
Provide valis radio safety certificate.
Operations/Management › Drills/Instruction › Fire
Issued 7 February 2006
Resolved
Provide proof of drills and EPIRB tests in log book.
Communications › Alarms/Indicators › Fire Alarm
Issued 7 February 2006
Resolved
Demonstrate proper operation of fixed firefighting alarms.
Engineering › Bilge Water Management System
Issued 5 February 2002
Resolved
Replace missing portable hand bilge pump. LEGACY COMPONENT DESC: Pump
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.