MAURY USCG vessel records
← All vessels

MSC ABY X

MSC ABY X is a 1999 freight ship. The Coast Guard has recorded 8 inspections since 2022, most recently in July 2026, along with 3 deficiencies and 3 operational controls.

Records from 2022 to 2026. Most recent: inspection, 13 July 2026.

Built
1999
Last inspected
13 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 July 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2022–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9166778
489733
Flag
LIBERIA
Maury page id
psix-489733

Documentation record

Tonnage as PSIX records it91560 - Regulatory (Subpart C or D), Gross Ton
92198 - Convention (Subpart B), Gross Ton
149078 - Displacement, Ton
53625 - Convention (Subpart B), Net Ton
50110 - Regulatory (Subpart C or D), Net Ton
110387 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

13 July 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8436977
29 June 2026 PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8418590
11 January 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7848157
29 December 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7843339
24 December 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7842201
7 October 2022 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7573334
23 September 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7565006
14 January 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7380328

Deficiency record · 3

11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 9 July 2026 Resolved
During the lowering of the lifeboat, the PSCO observed that the wire rope used to lower the lifeboat from inside the craft had jumped off the sheave. As a result, the lifeboat could not be lowered reliably using the controls from inside the craft.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2026
Resolved 10 July 2026
Resolution: Received DNV Class report stating the sleeve bearing was lubricated and shaft bolt tightened to minimize clearance between the roller and the guard. Satisfactory high speed lowering test was completed and witnessed by surveyor.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 July 2026 Resolved
PSCO observed cut wires in multiple locations that crew was unable to determine if the wires were live or not. These wires were wrapped in electrical tape, but otherwise unprotected, creating an unsafe practice for the crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2026
Resolved 10 July 2026
Resolution: Received DNV class report stating. The cut wires, wire-to-wire connections wrapped only with electrical tape, and other unprotected wiring associated with the bridge glass heating equipment were removed and properly reinstalled.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 July 2026 Resolved
The PSCO observed that the painter line penetration was loose, resulting in loss of watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2026
Resolved 16 July 2026
Resolution: Eyelink was pushed back in and liferaft was verified that it is 100% functional by servicing company.

Ownership record