Records from 1985 to 2017. Most recent: inspection, 13 April 2017.
Documentation record
Registered dimensions (L × B × D)242.0 ft × 60.0 ft × 15.4 ft
Registered tonnagegross 1,804 / net 1,804
ITC dimensions (L × B × D)229.2 ft × 60.0 ft × 16.0 ft
ITC tonnagegross 3,893 / net 2,177
BuilderZIDELL EXPLORATIONS INC · PORTLAND, OR, UNITED STATES · built 1976
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 21 January 2026 · expires 31 January 2027
Service, as the file records itFish Processing Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1804 - Regulatory (Subpart C or D), Gross Ton
3893 - Convention (Subpart B), Gross Ton
1804 - Regulatory (Subpart C or D), Net Ton
2177 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
13 April 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6133116
6 June 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1053224
1 February 2000
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1045570
3 January 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 811868
26 October 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 434122
28 July 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1117763
23 July 1998
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1460215
30 July 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1119374
7 August 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1418031
26 September 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1419502
30 January 1995
Examination of Repairs · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1401978
21 September 1994
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1358534
9 September 1993
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1359642
19 October 1992
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1366756
16 July 1992
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 956007
8 January 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 953011
28 December 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1239426
13 November 1990
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1216124
24 February 1990
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 902518
12 January 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 916005
12 December 1988
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 886476
17 November 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1023911
22 June 1987
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1008105
10 December 1986
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1311118
11 April 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 522667
27 January 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1001383
7 August 1985
Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 984425
8 January 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 976395
Electrical
Issued 30 July 1997
Resolved
REMOVE WIRE FROM NUMBER 4 BALLAST TANK ON STARBOARD SIDE AFT. SUBMIT PLANS TO REROUTE WIRE ABOVE DECK OR REMOVE SAME FROM VESSEL AND DISABLE CIRCUIT.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Construction/Loadline
Issued 30 January 1995
Resolved
Make permanent repairs to fractures found in no. 2 port and stbd ballast tanks to the satisfaction of the attending Marine Inspector prior to placing the vessel in service.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Deck/Cargo
Issued 13 November 1990
Resolved
RENEW PRESSURE GAUGE ON AIR RECEIVER.
Condition: Unknown
Due 13 November 1990
Resolved 13 November 1990
Electrical
Issued 13 November 1990
Resolved
MAKE PROPER REPAIRS TO BATTERY BOX TO INCLUDE SEALING HOLE IN BOTTOM AND RENEWING LOAD LINING.
Condition: Unknown
Due 13 November 1990
Resolved 13 November 1990
Electrical
Issued 13 November 1990
Resolved
SECURE AND MAKE PROPER ELECTRICAL CONNECTIONS TO BATTERY CHARGER FOR NAVIGATION LIGHTS BATTERIES.
Condition: Unknown
Due 13 November 1990
Resolved 13 November 1990
Construction/Loadline
Issued 13 November 1990
Resolved
REMOVE EXCESSIVE LUBE OIL LOCATED UNDER BALLAST PUMP PRIME MOVER.
Condition: Unknown
Due 13 November 1990
Resolved 13 November 1990
Deck/Cargo
Issued 10 December 1986
Resolved
AIR RECEIVER TO BE MADE AVAILABLE FOR USCG MARINE INSPECTOR TO CONDUCT INTERNAL INSPECTION OR WITNESS HYDROSTATIC TEST, AS REQUIRED BY 46 CFR 61.10-5(6).
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986