MAURY USCG vessel records Sign in
← All vessels

OCEAN YORKTOWN

OCEAN YORKTOWN is a 1976 mobile offshore drilling unit. The Coast Guard has recorded 34 inspections since 1981, most recently in April 2018, along with 127 deficiencies.

Records from 1981 to 2018. Most recent: inspection, 13 April 2018.

Built
1976
Last inspected
13 April 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYG6842
Flag
UNITED STATES
—
Maury page id
psix-48990

Inspections, by type

…with no type recorded19
Years with a record 11 calendar years (1981–2018)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it8593 - Regulatory (Subpart C or D), Gross Ton
7703 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

13 April 2018 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6391228
1 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927569
9 March 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931174
14 February 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927370
16 January 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925201
16 January 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238407
16 January 1991 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238409
6 February 1990 Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918268
27 November 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 904063
23 May 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898747
22 May 1989 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1044201
18 January 1989 Drydock Extension · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204888
8 June 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1205232
22 February 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029088
23 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334026
9 July 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326149
14 May 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332117
9 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007174
20 January 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322931
16 July 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299299
7 February 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999080
4 September 1985 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 989261
20 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 983495
19 April 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 984615
21 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979828
9 January 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977028
8 July 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280362
4 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282272
8 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280886
1 September 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271684
29 April 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970013
1 March 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969084
4 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271144
8 January 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277539

Deficiency record · 127

Unknown
Issued 14 February 1991 Resolved
CONDUCT WEIGHT TEST ON #4 LIFE BOAT.
Condition: Unknown
Due 26 April 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 14 February 1991 Resolved
CONDUCT INTERNAL INSPECTION ON FOUR DRY BULK TANKS. THE FOLLOWING TWO_x001C_ WERE INSPECTED THIS DATES; 7968 AND 7971.
Condition: Unknown
Due 26 April 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 14 February 1991 Resolved
SUBMIT PROOF THAT THE AIR RECEIVER ON THE DRILL FLOOR HAS ASME OR COAST GUARD APPROVAL AND REMOUNT PLATE TO SHOW MAXIMUM ALLOWABLE WORKING PRESSUREOR HYDROSTATICALLY TEST THE TANK IN THE PRESENCE OF A COAST GUARD INSPECTOR._x001C_
Condition: Unknown
Due 26 April 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 14 February 1991 Resolved
CONDUCT INTERNAL INSPECTION ON ALL HIGH PRESSURE AIR RECEIVERS EXCEPT THE _x001C_FOLLOWING SIX; PIT 75422, PIT 75347, PIT 75371, PIT 75337, PIT 75366 WHICH_x001C_WERE INSPECTED THIS DATE. INSPECTION TO INCLUDE RELIEF VALVES.
Condition: Unknown
Due 26 April 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 16 January 1991 Resolved
PROVIDE WIRE LIGHT GUARDS FOR FOUR SPOTLIGHTS IN MOON POOL AREA
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Electrical
Issued 6 February 1990 Resolved
PROVE PROPER PURGING OF MUD MONITOR UNIT, REMOTE TV MONITOR AND MUD FLOW INDICATOR
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Electrical
Issued 6 February 1990 Resolved
PROVIDE PROPER ALARM FOR LOSS OF PURGE ON SENSOR INTERFACE FOR MARTIN DECKER SYSTEM
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Electrical
Issued 6 February 1990 Resolved
PROVE EXLOG EQUIPMENT ON DRILL FLOOR IS INTRINSICALLY SAFE
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Electrical
Issued 6 February 1990 Resolved
REPAIR WORN CABLE ON BJ HYDRAULIC SYSTEM
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Construction/Loadline
Issued 6 February 1990 Resolved
MAKE REPAIRS TO THE 7S, 4S, 15S, AND 3P REMOTE TANK INDICATORS
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Electrical
Issued 6 February 1990 Resolved
POUR EYS FITTINGS ON SWACO UNIT
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Construction/Loadline
Issued 22 May 1989 Resolved
IN THE PRESENCE OF CG MARINE INSPECTOR, CONDUCT AN UNDERWATER EXAMINATION OF BOTH BARGE HULLS FROM THE 20 FT. WATERLINE AND BELOW.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 18 January 1989 Resolved
TEST EMERGENCY BATTERIES IN ACCORDANCE WITH 46 CFR 109.211 AND MAKE APPROPRIATE LOG ENTRY.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Lifesaving
Issued 18 January 1989 Resolved
STRIP LIFEBOATS IN ACCORDANCE WITH 46 CFR 109.217 NAD MAKE APPROPRIATE LOG ENTRY.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Lifesaving
Issued 18 January 1989 Resolved
STENCIL IN RED NEXT TO THE RELEASING GEAR OF ALL LIFEBOATS "DANGER - LEVER DROPS BOAT" OR "DANGER - LEVER RELEASES HOOKS."
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Unknown
Issued 18 January 1989 Resolved
ADJUST THE ALIGNMENT OF ALL INTERLOCKS ON THE PORT AND STARBOARD ELEVATORS AND SHOW PROPER OPERATION TO A COAST GUARD INSPECTOR.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
REPLACE THE WASTED CONDUIT RUN ON THE MAIN DECK LOCATED BY CAPSULE NUMBER 2.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Deck/Cargo
Issued 18 January 1989 Resolved
HAVE THE QUADRENNIAL INSPECTION PERFORMED ON THE CRANES.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PRIOR TO DRILLING MOUNT THE LOOSE ELECTRICAL JUNCTION BOX ON THE BACK WALL ON THE DRILL FLOOR.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
REPAIR THE ELECTRICAL PLUG CONNECTION ON THE DRAW WORKS HEATER CONNECTION.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PRIOR TO DRILLING INSTALL A VISUAL OR AUDIBLE LOSS OF AIR PURGE ALARM ON THE DRILLER'S CONSOLE MUD PIT VOLUME TOTALIZER.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PRIOR TO DRILLING POUR AND REPLACE PLUGS ON THE TWO OPEN EYS FITTINGS IN THE DRILLERS CONSOLE.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
REMOUNT THE LOOSE ELECTRICAL JUNCTION BOX PORTSIDE FORWARD IN THE MUD PIT ROOM,
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Unknown
Issued 18 January 1989 Resolved
REPAINT THE HELICOPTER DECK FUELING HOSE RACK ANY OTHER COLOR THAN RED.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
INSTALL A VISUAL OR AUDIBLE LOSS OF AIR PURGE ALARM ON THE TWO NON- EXPLOSION PROOF JUNCTIONS BOXES ON THE DRAWWWORKS MOTOR IN ACCORDANCE WITH NFPA 496.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Construction/Loadline
Issued 18 January 1989 Resolved
PROPERLY SUPPORT THE PIPE IN THE SHALE SHAKER ROOM PRESENTLY HELD BY ROPE.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
REPLACE THE HANGER ON THE AFTER OVERHEAD LIGHT IN THE SHALE SHAKER ROOM AND REMOUNT THE TWO LOOSE ELECTRICAL JUNCTION BOXES IN THE SAME AREA.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PRIOR TO DRILLING SEAL ALL AFTER BULKHEAD WIRE PENETRATIONS IN THE SHALE SHAKER ROOM.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Fire Fighting
Issued 18 January 1989 Resolved
PROVIDE TWO ADDITIONAL SETS OF FIREMAN'S SUIT GLOVES FOR FIREMANS OUTFITS.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Navigation
Issued 18 January 1989 Resolved
PROVIDE CORRECT ARTIFICIAL ISLAND FOG SIGNAL (18 SEC OFF, 2 SEC ON). CURRENT CONFIGURATION ALLOWS FOR UNDERWAY USE ONLY.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Construction/Loadline
Issued 18 January 1989 Resolved
REPAIR DOGS TO MAIN DECK HATCH PORT SIDE FORWARD (1-DOG MISSING, ALL ARE FROZEN).
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Construction/Loadline
Issued 18 January 1989 Resolved
SUBMIT REPAIR PROPOSALS FOR BALLAST TANK REPAIRS CURRENTLY IN PROGRESS AND FUTURE EXPECTED REPAIRS TO BALLAST TANK 9 PORT.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Deck/Cargo
Issued 18 January 1989 Resolved
REPLCE WASTED HYDRAULIC PIPING IN VICINITY OF PORT SIDE FORWARD WINCH. SCHEDULE TEST WITH COAST GUARD AFTER REPAIRS ARE COMPLETE.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Fire Fighting
Issued 18 January 1989 Resolved
REPLACE WASTED FIREMAIN ON BOTH SECTIONS OF FOAM HOSE #2 STATION
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Unknown
Issued 18 January 1989 Resolved
MARK HELO FUELING FACILITIES "WARNING-HELICOPTER FUELING STATION-KEEP LIGHTS AND FIRE AWAY"
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Unknown
Issued 18 January 1989 Resolved
SUBMIT WRITTEN PROOF THAT THE FORKLIFT IS APPROVED BY UL OR FM.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
REPLACE ALL CLASS 1 DIVISION 2 ELECTRICAL GROMMET CONNECTORS LOCATED WITHIN CLASS 1 DIVISION 1 AREAS WITH THE PROPER POURED EYS FITTINGS.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PRIOR TO DRILLING POUR EYS FITTING FOR THE COAXIAL CABLE TV CONNECTION ABOVE THE DRILLERS CONSOLE.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Lifesaving
Issued 18 January 1989 Resolved
REMOVE OIL FROM BILGE IN CAPSULE #2 AND CAPSULE #1. OIL IS APPROXIMATELY 4"-6" DEEP.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Unknown
Issued 18 January 1989 Resolved
SUBMIT PROOF THAT THE AIR RECEIVER ON THE DRILL FLOOR HAS ASME OR COAST GUARD APPROVAL AND REMOUNT PLATE TO SHOW MAXIMUM ALLOWABLE WORKING PRESSURE OR HYDROSTATICALLY TEST THE TANK IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Construction/Loadline
Issued 18 January 1989 Resolved
PRIOR TO DRILLING INSERT AND WELD CLOSE THE HOLE IN THE OVERHEAD IN THE MUD PIT ROOM NEAR PIT NUMBER 3.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PLACE A CAP ON THE OPEN ELECTRICAL OUTLET PORTSIDE FORWARD IN THE MUD PIT ROOM OVER THE EXHAUST FAN
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
PRIOR TO DRILLING SEAL ALL BULKHEAD WIRE PENETRATIONS IN THE FORWARD MUD PIT BULK HEAD.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Fire Fighting
Issued 18 January 1989 Resolved
PROVE CURRENT (LAST 12 YEARS) HYDRO DATE ON NITROGEN CYLINDER ATTACHED TO DRY CHEMICAL HOSE AT MOON POOL OR REPLACE WITH NEW CYLINDER.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Fire Fighting
Issued 18 January 1989 Resolved
HAVE ALL FIREFIGHTING EXTINGUISHERS SERVICED. SUBMIT COPY OF REPORT TO OCMIMORGAN CITY.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Lifesaving
Issued 18 January 1989 Resolved
MAKE OPERABLE THE LIGHT ON RING BOUY STARBOARD SIDE AMIDSHIPS.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
REMOUNT HANGERS ON SHEATHED WIRING ON BULKHEAD MAIN DECK STARBOARD SIDE FORWARD.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
REMOUNT JUNCTION BOX LOCATED IN VICINITY OF STARBOARD SIDE BOW OBSTRUCTION LIGHT.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Lifesaving
Issued 18 January 1989 Resolved
REPLACE DETERIORATED LINE ON RING BOUY STBD SIDE BOW.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Lifesaving
Issued 18 January 1989 Resolved
REPLACE DETERIORATED LINE ON SMOKE/LIGHT RING BOUY ON PORTSIDE BOWAREA. RE-CONFIGURE FOR QUICK RELEASE.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Electrical
Issued 18 January 1989 Resolved
REMOUNT JUNCTION BOX LOCATED IN VICINITY OF PORT AFT OBSTRUCTION LIGHT.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Fire Fighting
Issued 18 January 1989 Resolved
SUBMIT COPY OF FOAM ANALYSIS TO [name withheld].
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Lifesaving
Issued 22 February 1988 Resolved
PROVIDE TWO (2) ADDITIONAL HAND-HELD PARACHUTE FLARES.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Lifesaving
Issued 22 February 1988 Resolved
REPAIR EYEGUARD AT EYEWASH STATION IN SHAKER HOUSE.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Deck/Cargo
Issued 22 February 1988 Resolved
REMOVE, REPAIR OR REPLACE LOAD CELLS IN ALL THREE CRANES.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Lifesaving
Issued 22 February 1988 Resolved
REPLACE OUTDATED BUOYSMOKE ATTACHED TO RING LIFE BUOY.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Electrical
Issued 22 February 1988 Resolved
MAKE ALL FITTINGS ON ELECTRICAL APPLIANCES IN WAY OF HAZARDOUS LOCATIONS AROUND HELO FUELLING EQUIPMENT SUITABLE FOR THAT CLASSIFIED LOCATION AS DEPICTED ON YOUR APPROVED PLAN.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Fire Fighting
Issued 22 February 1988 Resolved
REPACK STARBOARD FIRE PUMP, AND PROVIDE PRESSURE GAUGE FOR SAME.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Electrical
Issued 22 February 1988 Resolved
PLACE GLASS SIGHT-GLASSES ON OIL LUBE STORAGE TANK AND PLACE ROD PROTECTORSOR EQUIVALENT AROUND SAME. TANK LOCATED IN GENERATOR ROOM.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Electrical
Issued 22 February 1988 Resolved
APPROPRIATELY HANG LARGE GREY POWER CABLE ON PUMP IN MUD PIT ROOM WITH NON-CORROSIVE METAL BANDS AND PLACE EYS OR SIMILAR ACCEPTABLE FITTINGS ON JUNCTION BOXES OF MUD PIT FLOAT/LEVEL INDICATORS. 46 CFR 111.80-5
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Engineering
Issued 22 February 1988 Resolved
REPAIR GROUND WIRE ON REFUELLING NOZZLE ON HELIDECK.
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Deck/Cargo
Issued 20 January 1987 Resolved
MAKE OPERABLE THE LIMIT SWITCHES MAIN & WHIP ON THE PORT AND STARBOARD CRANES. REPAIR EXPOPSED ELECTRICAL CONDUCTOR ON THE ENGINE TERMINAL BLOCK STBD CRANE.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Fire Fighting
Issued 20 January 1987 Resolved
REPAIR THE FOAM TURRENT (CANNON) ON THE HELO DECK. ALL LOCKS INOPERATIVE
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Electrical
Issued 20 January 1987 Resolved
RENEW ALL WASTED ELECTRICAL CABLE SUPPORTS (TRAYS OR STUDS) AND RENEW ALL TIE WRAPS (MINIMUM WIDTH 1/2 INCH) IN SHALE SHAKER ROOM.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Electrical
Issued 20 January 1987 Resolved
SECURE ALL LOOSE ELECTRICAL CABLES THROUGHOUT VESSEL AND REPLACE PLASTIC TIE WRAPS WITH METAL TIE WRAPS WITH MINIMUM WIDTH OF AT LEAST 1/2 INCH.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Lifesaving
Issued 20 January 1987 Resolved
REPAIR ALL EGRESS LADDER ON COLUMNS 1,3,4,6. LADDERS BENT ORE MISSING.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Lifesaving
Issued 20 January 1987 Resolved
REPAIR OR REPLACE ALL THE LIMIT SWITCHES ON ALL FOUR (4) LIFE BOATS, NUC 4-78
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Lifesaving
Issued 20 January 1987 Resolved
PROPERLY MOUBT HYDROSTATIC RELEASES ON ALL LIFE RAFTS. RELEASES ARE TO BE INSTALLED SO THAT THE REQUIRED TENSION IS PULLING VERTICALLY AND NOT PLACING THE RELEASES IN A BIND.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Lifesaving
Issued 20 January 1987 Resolved
INSSTALL DAVIT LAUNCHED RAFT SYSTEM TO BE INSTALLED IN PLACE OFF THE RAFT (INFLATABLE) MANUFACTED AFTER 1979 IS INSTALLED. NUC 4-78
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Electrical
Issued 20 January 1987 Resolved
MAKE OPERABLE TWO (2) EXPLASION PROOF LIGHTS LOCATED DRILL FLOOR AFT.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Electrical
Issued 20 January 1987 Resolved
MAKE OPERABLE AND DEMONSTRATE IN PRESENCE OF COAST GUARD THE PURGE ALARM ONDRILLERS CONSOLE.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Accommodation/Occupational Safety
Issued 20 January 1987 Resolved
REPAIR EXISTING WATERMAKER TO MANUFACTURER'S RAATED CAPACITY OR REMOVE FROM VESSEL.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Accommodation/Occupational Safety
Issued 20 January 1987 Resolved
REPAIR LEAK IN COLD WATER SUPPLY LINE TO WASHING MACHINE, STBD LAUNDRY.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Deck/Cargo
Issued 7 February 1986 Resolved
INSTALL A GUARD ON THE AIR TUGGER, NEAR NO. 3 CAPSULE.
Condition: Unknown
Due 7 February 1986
Resolved 7 February 1986
Electrical
Issued 7 February 1986 Resolved
REPLACE RENEWABLE LINK FUSES IN THE GENERAL ALARM SYSTEM WITH NON-RENEWABLETYPE.
Condition: Unknown
Due 7 February 1986
Resolved 7 February 1986
Fire Fighting
Issued 9 January 1985 Resolved
(A)REPLACE THE APPLICATOR AT FIRE STATION #20. (B)REPLACE THE 1-1/2" X 8" NIPPLE AT FIRE STATION #25 AND MAKE THE VALVE HANDLE ACCESSIBLE. (C)REPLACETHE VALVE HANDLE AT FIRE STATION # 18. (D) REPLACE THE VALVE HANDLE AND THEWASTED NIPPLE AT FIRE STATION #12.
Condition: Unknown
Due 9 January 1985
Resolved 9 January 1985
Electrical
Issued 9 January 1985 Resolved
REPAIR THE EMERGENCY LIGHTING IN THE STARBOARD PUMP ROOM.
Condition: Unknown
Due 9 January 1985
Resolved 9 January 1985
Unknown
Issued 9 January 1985 Resolved
INSTALL PRESSURE RELIEF DEVICES ON THE 3 CEMENT TANKS AND THE 3 BARITE TANKS TO RELIEVE AT 40 PSIG OR LESS.
Condition: Unknown
Due 9 January 1985
Resolved 9 January 1985
Lifesaving
Issued 9 January 1985 Resolved
REPLACE OR SERVICE THE MAGNETIC COMPASS IN CAPSULE NUMBER ONE.
Condition: Unknown
Due 9 January 1985
Resolved 9 January 1985
Unknown
Issued 9 January 1985 Resolved
INTERNALLY EXAMINE AND TEST THE RELIEF VALVE ON THE #2 RIG AIR RECEIVER.
Condition: Unknown
Due 9 January 1985
Resolved 9 January 1985
Lifesaving
Issued 8 March 1984 Resolved
AREPAIR LIMIT SWITCHES ON STERN LIFEBOAT. 46CFR111.95.
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Fire Fighting
Issued 8 March 1984 Resolved
PROVIDE TWO (2) OXYGEN AND EXPLOSIVE METERS WITH UNDERWRITER'S LABORATORIESAS PER 46CFR108.497(C)
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Accommodation/Occupational Safety
Issued 8 March 1984 Resolved
REPLACE DEFORMED CLIPS ON SAFETY CHAINS, STARBOARD BOW RAIL AND RAFT STATION 1. 46CFR108.217
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Lifesaving
Issued 8 March 1984 Resolved
MARK LIFEBOAT STATION 1, AS PER 46CFR97.37-40.
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Lifesaving
Issued 8 March 1984 Resolved
PAINT NUMBER OF THE STERN LIFEBOAT AS, PER 46CFR97.37-37.
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Lifesaving
Issued 8 March 1984 Resolved
ADJUST TRANSMISSION ON STERN LIFEBOAT TO ASSURE SMOTH OPERATION AHEAD. 46CFR109.217
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Unknown
Issued 8 March 1984 Resolved
REPAIR AND REINSTALL RELIEF VALVES IN MUD CHARGING LINES IN MUD PUMP ROOM. 46CFR56.80
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Electrical
Issued 8 March 1984 Resolved
PROPERLY SPLICE OR REMOVE CONNECTION IN MUD PUMP ROOM. 46CFR11.60
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Fire Fighting
Issued 8 March 1984 Resolved
PROVIDE 75 FOOT HOSES FOR FIRE STATIONS 18-21. 46CFR108.419
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Navigation
Issued 8 March 1984 Resolved
PROVIDE PROPER BULBS FOR ALL NAVIGATION LIGHTS. 46CFR11.75-17
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Electrical
Issued 8 March 1984 Resolved
PROVIDE PROTECTION FOR SIGHT GLASSES ON BOTH LUBE OIL TANKS IN GENERATIOR SPACE. 46CFR56.50-80
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Fire Fighting
Issued 8 March 1984 Resolved
REMOVE ALL RAGS AND OIL FROM AROUND ENGINES. 46CFR58.01-20
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Construction/Loadline
Issued 8 March 1984 Resolved
MARK INBOARD SIDE OF PAINT LOCKER, STARBOARD BOW.
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Navigation
Issued 8 March 1984 Resolved
CLEAN LENS ON PORT RUNNING LIGHT AND STERN LIGHT. 46CFR111.75.17
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Lifesaving
Issued 8 March 1984 Resolved
PROVIDE TWO BUOYANT TYPE LINE THROWING ROCKETS, AS PER 46CFR45-15(A)(1).
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Lifesaving
Issued 8 March 1984 Resolved
PROVIDE TWELVE HAND HELD ROCKET PROPELLED, PARACHUTE, RED DISTRESS SIGNAL, AS PER 46CFR108.521.
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Documentation
Issued 8 March 1984 Resolved
PROVIDE EVIDENCE OF DESIGNATION OF MASTER OR PERSON-IN-CHARGE, AS PER 46CFR109.107.
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Unknown
Issued 8 March 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU ZAPATA YORKTOWN, DN578592
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Documentation
Issued 8 March 1984 Resolved
PROVIDE EVIDENCE OF DESIGNBATION OF CRANE OPERATORS, AS PER 46CFR109.527.
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Documentation
Issued 8 March 1984 Resolved
PROVIDE EVIDENCE OF OPERATIONS MANUAL APPROVAL AS PER NVC 4-78.
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Electrical
Issued 8 March 1984 Resolved
SERVICE AND LOAD TEST OBSTRUCTION LIGHT BATTERIES. 46CFR111.15
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Electrical
Issued 8 March 1984 Resolved
REPAIR REVERSE POWER TRIP ON NUMBER TWO GENERATOR. 46CFR111.30
Condition: Unknown
Due 8 March 1984
Resolved 8 March 1984
Lifesaving
Issued 4 January 1983 Resolved
PROVIDE 1500' AUXILIARY LINE FOR LINE THROWING GUN.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Fire Fighting
Issued 4 January 1983 Resolved
HAVE ALL FIXED FIRE EXTINGUISHING SYSTEMS SERVICED; SUBMIT FOAM SAMPLE FOR ANALYSIS; PROVIDE DOCUMENTATION OF SERVICING TO [name withheld].
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
PROPERLY SUSPEND WIRING THROUGHOUT SHAKER HOUSE WITH METAL BANDING.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
(REQUIREMENT 13 CONTINUED) REPLACE BROKEN PLUG BOX COVER IN SHAKER HOUSE.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
(REQUIREMENT 13 CONTINUED) REPLACE MISSING BOLTS IN JUNCTION BOX AT AFT SHAKER.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
PROVIDE PURGING SYSTEM ON SENSOR INTERFACE BOX.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
(REQUIREMENT 14 CONTINUED) PROVIDE AUDIBLE VISUAL ALARM ON IRON ROUGHNECK PURGING SYSTEM.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
(REQUIREMENT 14 CONTINUED) REPAIR ALARM FOR DRILLER'S CONSOLE PURGING SYS- TEM.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
(REQUIREMENT 14 CONTINUED) REPLACE VISUAL ALARM FOR MUD VOLUME TOTALIZER PURGE SYSTEM.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
(REQUIREMENT 14 CONTINUED) PROVIDE PURGE SYSTEM AND ALARM ON MARTIN DECKER HEET RITE RECORDER.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Accommodation/Occupational Safety
Issued 4 January 1983 Resolved
(REQUIREMENT 14 CONTINUED) REPAIR VENT FAN IN DRILLER'S SHACK FOR POSITIVE VENTILATION.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
(REQUIREMENT 14 CONTINUED) PROPERLY ROUTE AND SUSPEND CABLE TO WIRE LINE UNIT.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
(REQUIREMENT 14 CONTINUED) REPLACE MISSING BOLT ON AIRCRAFT BEACON SWITCH ON DRILL FLOOR.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
REPAIR EMERGENCY LIGHT OVER WELDER'S BENCH.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Unknown
Issued 4 January 1983 Resolved
REPLACE RELIEF VALVE ON BULK AIR TANK WITH MAXIMUM 44 PSI, FITTED WITH HANDRELIEVING GEAR.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Unknown
Issued 4 January 1983 Resolved
REPLACE RELIEF VALVE ON AFT START AIR TANK (HOU74-1139) WITH MAXIMUM 220 PSI, FITTED WITH HAND RELIEVING GEAR.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Unknown
Issued 4 January 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL ZAPATA YORKTOWN, DN578592.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Unknown
Issued 4 January 1983 Resolved
REPLACE ONE (1) RUCKER BOTTLE RELIEF VALVE MISSING HAND RELIEVING GEAR.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Construction/Loadline
Issued 4 January 1983 Resolved
REPAIR THE FOLLOWING VALVES IN PUMP ROOMS: PORT-#10, 14 AND 15 BALLAST SUCTIONS, STARBOARD-BILGE SUMP DISCHARGE, #2 BALLAST PUMP SUCTION AND #10
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Unknown
Issued 4 January 1983 Resolved
(REQUIREMENT 2 CONTINUED) BALLAST SUCTION.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
PROPERLY SUSPEND WIRING TO STROKE COUNTERS ON #2 MUD PUMP.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
MAKE THE FOLLOWING CORRECTIONS TO EQUIPMENT IN MUD PITS: (A)PROVIDE SEAL ONJUNCTION BOX TO MUD CENTRIFUGE MOTOR. (B)REPLACE MISSING BOLT IN HORN
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Electrical
Issued 4 January 1983 Resolved
(REQUIREMENT 7 CONTINUED) DRIVER. (C) PROPERLY SUSPEND WIRING NEAR NATURAL VENTS BEHIND HORN.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Lifesaving
Issued 4 January 1983 Resolved
CHANGE OUT FUEL ON BOTH CAPSULES AND LIFEBOAT.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983
Lifesaving
Issued 4 January 1983 Resolved
PROVIDE ONE (1) ADDITIONAL PAINTER FOR BOTH CAPSULES.
Condition: Unknown
Due 4 January 1983
Resolved 4 January 1983

Ownership record