Records from 2009 to 2025. Most recent: inspection, 10 March 2025.
Inspection history · 27
10 March 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8085693
6 February 2025
In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8075971
8 April 2024
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7887985
8 February 2024
Deficiency Check · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7847135
31 January 2024
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7858504
25 January 2024
Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7855479
6 June 2023
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7684903
1 December 2022
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7616430
25 July 2022
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7507499
10 January 2022
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7381198
17 August 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7271996
8 July 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6971260
19 June 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6717824
30 May 2019
Deficiency Check · COI Inspection · Plan Review (Other than "T")
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6675582
11 January 2019
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6609206
3 August 2018
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6490744
31 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6400704
11 May 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6143989
26 April 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6133355
21 April 2017
Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6127947
3 March 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6098679
23 February 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065371
22 August 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5980257
1 August 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5960888
7 July 2016
Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5935090
7 July 2016
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5979957
15 April 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5852912
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 March 2025
Resolved
Main propulsion machinery must be provided with automatic shut-off controls in accordance with part 62 of this subchapter. Provide technical reports proving proper operation of Both MDE, Both SSDG and Bow Thruster Engine shutdowns of Low Lube Oil, Over speed and High Jacket Water (J/W Alarm only).
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: Operator provided technical reports and demonstrated stbd SSDG on load during Marine Inspector attendance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 March 2025
Resolved
Each self-propelled vessel and each mobile offshore drilling unit must have at least two electric generating sources. Vessel self-reported that the #1 SSDG was unable to start the previous day, technicians troubleshooting to potentially the alternator and are working on fixing it.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: Vessel demonstrated #1 SSDG on load to Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 March 2025
Resolved
For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse. Indicator lights for watertight doors in E/R found not operating, nor does the indicator light for the Rudder Room high bilge light operate, does provide an audible alarm.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: WTD indicators observed operating during MI attendence.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 March 2025
Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. #1 SSDG Ground Detector push button found broken and falling back into switchboard enclosure.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2025
Resolution: Push button was repaired and observed during Marine Inspector attendence.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2025
Resolved
There must be ground detection for each; Ship's service power system. Found Off line #1 SSDG with one active ground.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2025
Resolution: SSDG observed operating and no ground faults indicated.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 March 2025
Resolved
Distress flares. Each OSV must carry not less than 12 rocket parachute flares approved under approval series 160.136. Vessel only has 11 flares on board.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: MI observed correct quantity of flares onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 March 2025
Resolved
A vessel of less than 100 GRT must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. Emergency lights inoperable in main deck/galley, 01 level house, engine room and embarkation station.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2025
Resolution: E lighting was functional during loss of power test in presence of MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 March 2025
Resolved
Each hatch exposed to the weather must be watertight. Each hatch cover must have captive chain or other device to prevent its loss. Lazarette hatch gasket seal was deteriorated and captive chain weld was broken off.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: Lazarette hatch seal and chain in place during Marine Inspector visit.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 April 2024
Resolved
Each liferaft must be arranged for float free launching.
Both port and starboard life rafts were not connected to the weak link on the hydrostatic release unit via the sea painter. Life rafts would not automatically inflate in the event of vessel sinking. Instructed crew on proper installation as per manufacturer instructions.
46 CFR 133.130(b)(7)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 April 2024
Resolved 8 April 2024
Resolution: Crew correctly installed sea painters to weak link.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 February 2024
Resolved
2nd deck overhead wire junction (IVO stbd ac) deteriorated
Action required: 705 - Other - as specified
Resolved 15 February 2024
Resolution: Overhead junction had been reworked and appeared sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 February 2024
Resolved
2nd deck tonnage opening IVO deck access WTD severely wasted at base.
Action required: 705 - Other - as specified
Resolved 14 February 2024
Resolution: Tonnage opening was removed, lower 8" cropped and rewelded, treated, and reinstalled. WTD operates sat, and tonnage plate now seals on bulkhead.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2022
Resolved
Each connection to a conductor or a terminal part of a conductor must be made within an enclosure and have a pressure-type connector on each conductor; have a solder lug on each conductor; have a splice made with a pressure-type connector to a flexible lead or conductor; or be splice-soldered, brazed, or welded to a flexible lead or conductor. Dead end wires observed aft of superstructure on 01 deck. Remove dead end wires or provide proper termination.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel removed dead end wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2022
Resolved
No flexible cord may be used except: (1) As allowed under Sections 400-7 and 400-8 of NFPA NEC 2002; and (2) In accordance with Table 400-4 in NFPA NEC 2002. Freezers were found with permanent extension cords in the accomodations and in the tank tunnel. Remove extension cords. If installation of new electrical outlets is required, submit modified electrical plans to the Marine Safety Center.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel repositioned freezers to not require exension cords.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 25 July 2022
Resolved
On each cooking appliance, sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed. Sea rails were not found. Provde sea rails.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel located and installed sea rails.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2022
Resolved
The remote stopping-systems required by § 129.540 of this subchapter must be clearly marked to show what system each controls. Markings were painted over and worn for remote stopping devices on main deck. Provide proper markings.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel re-labeled stops and blanked off damaged spare button.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 July 2022
Resolved
Each ring life buoy must be marked in block capital letters with the vessel's name and be marked with Type I or II retro-reflective material approved under subpart 164.018 of this chapter. The arrangement of the retro-reflective material must comply with IMO Resolution A.658(16). Ring life buoy found on port side aft with black paint obscuring vessel name and retro reflective tape.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel replaced ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 July 2022
Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valves located at the tank. If valves are installed on the inside of the tank, they may be made of cast iron and arranged for remote control only. Additional valves for local control must be located in the space where the system exits from the tank or adjacent tanks. Remote shut-off valves were found to be seized and not easily operated from main deck. Repair and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel greased valves and provided video showing operation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 August 2021
Resolved
A vessel of less than 100 gross tons must have adequate
emergency lighting fitted along the line of escape to
the main deck from accommodations and working
(machinery) spaces below the main deck. Forward and Aft
tunnel passageway emergency lighting were inoperable.
Correct lighting deficiency to satisfaction of attending
Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 4 October 2021
Resolution: Corrected lighting deficiency to satisfaction of attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 August 2021
Resolved
Each vessel must be fitted with a compass suitable for
the intended service of the vessel. Vessel's magnetic
compass was determined to be at least 10 degrees off
after checking against the vessels other onbaord
equipment. Have compass corrected to satisfaction of
attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 23 August 2021
Resolution: Compass corrected to satisfaction of attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 17 August 2021
Resolved
Employers must ensure that they and their crew members
meet the requirements of Part 16 - Chemical Testing.
Employees were not able to provide any proof of
enrollment in the vessel's chemical testing program.
Provide proof of crew members enrollment in chemical
testing program from employer/consortium to attending
Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 23 August 2021
Resolution: Provided proof of crew members enrollment in chemical testing program from employer/consortium to attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2021
Resolved
Lifebuoy must be fitted with a buoyant lifeline that is
of a breaking strength which is not less than 1,124
pounds-force. Grab line on port bridge wing lifebuoy was found wasted. Proof strength or replace as per
regulation and to attending Marine Inspectors
satisfaction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 23 August 2021
Resolution: Replaced grab line as per regulation and to attending Marine Inspectors satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2021
Resolved
The self-igniting light must be approved under approval
series 46 CFR 161.010 and must be attached to the
buoyant apparatus or lifefloat by a 12-thread manila or
equivalent lanyard that is at least 5.5 meters (18 feet)
long. This lanyard (found on self-igniting light forward
of wheelhouse) was found wasted. Replace to satisfaction
of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 23 August 2021
Resolution: Replace lanyard to satisfaction of attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 July 2020
Resolved
Vital systems that are automatically or remotely controlled must be provided with instrumentation to monitor system parameters. Vessel was unable to to demonstrate function of safety shutdowns and alarms for the MDEs, SSDGs, and bow thruster high cooling water temp alarm, overspeed, and low lube oil pressure. Demonstrate proper operation of shutdowns and alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 31 July 2020
Resolution: Sector LA/LB inspector witnessed tests of alarms and shut downs.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 July 2020
Resolved
VHF DSC radios are not provided with MMSI and GPS. Provide compliant VHF DSC radios.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 29 July 2020
Resolution: Vessel programmed MMSI and provided GPS to DSC VHF radios.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 July 2020
Resolved
Captive chains not connected to steering and engine room escape hatches. Connect captive chains.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 29 July 2020
Resolution: Vessel provided captive chains for both hatches.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 May 2019
Resolved
Provide 11 additional immersion suits for a total of 31; Vessel restricted to 20 persons on board when operating north of 32 degrees north latitude.
Action required: 705 - Other - as specified
Resolved 19 June 2019
Resolution: Additional suits provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2019
Resolved
Properly mark storage location of life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 19 June 2019
Resolution: Stowage marked.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 May 2019
Resolved
Properly mark location of fuel oil shutoff valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 19 June 2019
Resolution: Valves labeled.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 30 May 2019
Resolved
Update Safety (Fire) plan and submit for approval to include 31 lifejackets and 31 immersion suit locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 22 July 2019
Resolution: Approved amended Safety (Fire) Plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2019
Resolved
Properly wire alarm systems on main and auxiliary machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 19 June 2019
Resolution: Alarm systems properly wired.
Engineering › Fuel Oil Service System › Valve, Control
Issued 31 May 2018
Resolved
Label remote fuel shutoff valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 July 2018
Resolved 25 June 2018
Resolution: Labled
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 31 May 2018
Resolved
Prove operation of low L/O and overspeed shutdowns, high J/W temp alarms for BMDE, BSSDG, and BT.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2018
Resolution: Tested SAT
Construction/Loadline › Structures › Transverse Bulkhead
Issued 31 May 2018
Resolved
Replace compression block for MCT in ER FWD BLKHD.
Action required: 705 - Other - as specified
Due 1 July 2018
Resolved 25 June 2018
Resolution: Repaired
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 May 2018
Resolved
Complete drills
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2018
Resolution: Drills Conducted
Navigation › Collision/Grounding Avoidance › Transponder
Issued 31 May 2018
Resolved
Prove proper operation of AIS
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2018
Resolution: Working Properly
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 May 2018
Resolved
Update fire control plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 25 June 2018
Resolution: UPDATED and submitted to OCMI for approval
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 31 May 2018
Resolved
Provide DAPI program manual
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 25 June 2018
Resolution: Manual on board
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2018
Resolved
Update/replensish first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 25 June 2018
Resolution: New kit on board
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 31 May 2018
Resolved
Update NTVRP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 25 June 2018
Resolution: UPDATED
Construction/Loadline › Structures › Scupper
Issued 31 May 2018
Resolved
Repair hole in scuttle and remove shore tie from penetration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2018
Resolution: Repaired
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Number
Issued 21 April 2017
Resolved
Prior to carriage of grade D or lower flammable or combustable cargos; install B-V semi-portable fire extinguisher.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: B-V installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 April 2017
Resolved
Provide hydro test results of CO2 extinguisher on the bridge.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: Extinguisher passed hydro test.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 21 April 2017
Resolved
Provide copy of NOI for VGP.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: NOI provided.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 April 2017
Resolved
Clean up gear adrift in E/R.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: E/R gear cleaned up.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 21 April 2017
Resolved
Provide rescue platform.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: Rescue ladder provided on board.
Construction/Loadline › Structures › Superstructure
Issued 23 February 2017
Resolved
Repair 3 window seals above pilot house aft operating station.
Condition: Improper/Lack of Maintenance
Due 23 March 2017
Resolved 3 March 2017
Resolution: 04 aft operating station window frames were cropped and renewed.
Engineering › Steering Gear System › Ram Seal
Issued 23 February 2017
Resolved
Evaluate and repair as needed the stbd steering ram during sea trial with CG marine inspector.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 28 February 2017
Construction/Loadline › Structures › Superstructure
Issued 23 February 2017
Resolved
Repair hole in house behind main deck door.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 28 February 2017
Engineering › Compressed Air System (start air) › Valve
Issued 23 February 2017
Resolved
Demonstrate proper operation of air tank relief valves in place.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 28 February 2017
Stability › Incline Test › General
Issued 1 August 2016
Resolved
Vessel to provide stability calculations for addition of A frame crane
Due 31 October 2016
Resolved 27 October 2016
Resolution: re-issued
Stability › Incline Test › General
Issued 1 August 2016
Resolved
Provide an updated stability letter and/or stability book approved by MSC showing installation of the a-frame crane on the stern.
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 15 December 2016
Resolution: VESSEL REMOVED A-FRAME FROM VESSEL
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 7 July 2016
Resolved
Submit A-frame plans to MSC for approval prior to operating the equipment.
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 1 August 2016
Stability › Intact Stability (when using lifting gear) › General
Issued 7 July 2016
Resolved
Once A-frame design is approved by MSC, complete design verification and system testing in the presence of MI prior to operation of A-Frame.
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 1 August 2016
Engineering › Lubricating Oil Service System › Hose
Issued 7 July 2016
Resolved
Make proper repairs to hydraulic hose and complete a pressure test.
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 1 August 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 April 2016
Resolved
Replace (3) batteries for life ring(s).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 22 August 2016
Resolution: NEW BATTERIES INSTALLED
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 April 2016
Resolved
PLace machinery guard for starboard winch system for the four-point mooring system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 22 August 2016
Resolution: Guard on winch installed
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 15 April 2016
Resolved
Lock the sewage overboard discharge valve to prevent accidental discharge.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 15 April 2016
Resolution: Discharge valve properly locked.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 April 2016
Resolved
Ship name labels severely faded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 15 April 2016
Resolution: Lifebuoy labels renewed with permanent ink.