M/V CLEAN OCEAN

M/V CLEAN OCEAN is a 1999 offshore supply vessel. The Coast Guard has recorded 59 inspections since 1999, most recently in March 2025, along with 70 deficiencies, 1 operational control and 3 casualty investigations between 2009 and 2022.

Records from 1999 to 2025. Most recent: inspection, 10 March 2025.

Built
1999
Last inspected
10 March 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9202352 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE7605
489911
Flag
UNITED STATES
367395280
Maury page id
psix-489911

Inspections, by type

…with no type recorded8
Years with a record 25 calendar years (1999–2025)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)130.0 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 90 / net 50
ITC dimensions (L × B × D)130.0 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 423 / net 136
BuilderBOLLINGER SHIPYARDS LOCK · LOCKPORT, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 September 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
423 - Convention (Subpart B), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
136 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE7605MMSI 367395280 · active · compulsorily equipped · granted 20 December 2018, expires 14 February 2029
WDB7456MMSI 338887000 · cancelled · compulsorily equipped · granted 23 April 2004, cancelled 18 February 2009 · licensed under a name not among this hull’s recorded names (not shown)
WCY9479MMSI 338887000 · cancelled · compulsorily equipped · granted 24 March 1999, cancelled 3 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MARTHA JANE Commercial Fishing Vessel · MISLE 473517 · 1 December 2022 · activity 7616430

Inspection history · 59

10 March 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8085693
6 February 2025 In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8075971
8 April 2024 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7887985
8 February 2024 Deficiency Check · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7847135
31 January 2024 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7858504
25 January 2024 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7855479
6 June 2023 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7684903
1 December 2022 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7616430
25 July 2022 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7507499
10 January 2022 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7381198
17 August 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7271996
8 July 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6971260
19 June 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6717824
30 May 2019 Deficiency Check · COI Inspection · Plan Review (Other than "T")
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6675582
11 January 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6609206
3 August 2018 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6490744
31 May 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6400704
11 May 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6143989
26 April 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6133355
21 April 2017 Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6127947
3 March 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6098679
23 February 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065371
22 August 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5980257
1 August 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5960888
7 July 2016 Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5935090
7 July 2016 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5979957
15 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5852912
20 October 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5771010
18 August 2015 Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5220348
25 June 2014 COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4893146
13 July 2012 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4377018
14 February 2012 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4244231
7 February 2012 Drydock Extension
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4240266
27 July 2011 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4095846
23 April 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3458987
23 February 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3440153
9 February 2009 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3418511
29 January 2009 Damage Survey · Inclining Experiment · Deadweight Survey · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3451687
23 June 2008 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3260496
9 July 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2991509
21 March 2007 Hull Examination · Re-Inspection · Internal Structural Exam · MTSA Verification · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2920014
22 February 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2875966
31 March 2006 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2613428
23 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571386
22 March 2005 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2316279
4 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303603
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290106
4 January 2005 Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2269187
28 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2230358
25 February 2004 Hull Examination · Re-Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2012754
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971952
16 September 2003 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1906460
25 June 2003 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1824572
3 July 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1640586
2 July 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1640278
5 April 2002 Cargo Tank Internal · Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1598814
2 April 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433809
9 June 2000 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1472467
5 April 1999 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433463

Deficiency record · 70

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 March 2025 Resolved
Main propulsion machinery must be provided with automatic shut-off controls in accordance with part 62 of this subchapter. Provide technical reports proving proper operation of Both MDE, Both SSDG and Bow Thruster Engine shutdowns of Low Lube Oil, Over speed and High Jacket Water (J/W Alarm only).
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: Operator provided technical reports and demonstrated stbd SSDG on load during Marine Inspector attendance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 March 2025 Resolved
Each self-propelled vessel and each mobile offshore drilling unit must have at least two electric generating sources. Vessel self-reported that the #1 SSDG was unable to start the previous day, technicians troubleshooting to potentially the alternator and are working on fixing it.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: Vessel demonstrated #1 SSDG on load to Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 March 2025 Resolved
For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse. Indicator lights for watertight doors in E/R found not operating, nor does the indicator light for the Rudder Room high bilge light operate, does provide an audible alarm.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: WTD indicators observed operating during MI attendence.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 March 2025 Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. #1 SSDG Ground Detector push button found broken and falling back into switchboard enclosure.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2025
Resolution: Push button was repaired and observed during Marine Inspector attendence.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2025 Resolved
There must be ground detection for each; Ship's service power system. Found Off line #1 SSDG with one active ground.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2025
Resolution: SSDG observed operating and no ground faults indicated.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 March 2025 Resolved
Distress flares. Each OSV must carry not less than 12 rocket parachute flares approved under approval series 160.136. Vessel only has 11 flares on board.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: MI observed correct quantity of flares onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 March 2025 Resolved
A vessel of less than 100 GRT must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. Emergency lights inoperable in main deck/galley, 01 level house, engine room and embarkation station.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2025
Resolution: E lighting was functional during loss of power test in presence of MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 March 2025 Resolved
Each hatch exposed to the weather must be watertight. Each hatch cover must have captive chain or other device to prevent its loss. Lazarette hatch gasket seal was deteriorated and captive chain weld was broken off.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2025
Resolution: Lazarette hatch seal and chain in place during Marine Inspector visit.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 April 2024 Resolved
Each liferaft must be arranged for float free launching. Both port and starboard life rafts were not connected to the weak link on the hydrostatic release unit via the sea painter. Life rafts would not automatically inflate in the event of vessel sinking. Instructed crew on proper installation as per manufacturer instructions. 46 CFR 133.130(b)(7)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 April 2024
Resolved 8 April 2024
Resolution: Crew correctly installed sea painters to weak link.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 February 2024 Resolved
2nd deck overhead wire junction (IVO stbd ac) deteriorated
Action required: 705 - Other - as specified
Resolved 15 February 2024
Resolution: Overhead junction had been reworked and appeared sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 February 2024 Resolved
2nd deck tonnage opening IVO deck access WTD severely wasted at base.
Action required: 705 - Other - as specified
Resolved 14 February 2024
Resolution: Tonnage opening was removed, lower 8" cropped and rewelded, treated, and reinstalled. WTD operates sat, and tonnage plate now seals on bulkhead.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2022 Resolved
Each connection to a conductor or a terminal part of a conductor must be made within an enclosure and have a pressure-type connector on each conductor; have a solder lug on each conductor; have a splice made with a pressure-type connector to a flexible lead or conductor; or be splice-soldered, brazed, or welded to a flexible lead or conductor. Dead end wires observed aft of superstructure on 01 deck. Remove dead end wires or provide proper termination.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel removed dead end wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2022 Resolved
No flexible cord may be used except: (1) As allowed under Sections 400-7 and 400-8 of NFPA NEC 2002; and (2) In accordance with Table 400-4 in NFPA NEC 2002. Freezers were found with permanent extension cords in the accomodations and in the tank tunnel. Remove extension cords. If installation of new electrical outlets is required, submit modified electrical plans to the Marine Safety Center.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel repositioned freezers to not require exension cords.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 25 July 2022 Resolved
On each cooking appliance, sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed. Sea rails were not found. Provde sea rails.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel located and installed sea rails.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2022 Resolved
The remote stopping-systems required by § 129.540 of this subchapter must be clearly marked to show what system each controls. Markings were painted over and worn for remote stopping devices on main deck. Provide proper markings.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel re-labeled stops and blanked off damaged spare button.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 July 2022 Resolved
Each ring life buoy must be marked in block capital letters with the vessel's name and be marked with Type I or II retro-reflective material approved under subpart 164.018 of this chapter. The arrangement of the retro-reflective material must comply with IMO Resolution A.658(16). Ring life buoy found on port side aft with black paint obscuring vessel name and retro reflective tape.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel replaced ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 July 2022 Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valves located at the tank. If valves are installed on the inside of the tank, they may be made of cast iron and arranged for remote control only. Additional valves for local control must be located in the space where the system exits from the tank or adjacent tanks. Remote shut-off valves were found to be seized and not easily operated from main deck. Repair and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 2 August 2022
Resolution: Vessel greased valves and provided video showing operation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 August 2021 Resolved
A vessel of less than 100 gross tons must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. Forward and Aft tunnel passageway emergency lighting were inoperable. Correct lighting deficiency to satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 4 October 2021
Resolution: Corrected lighting deficiency to satisfaction of attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 August 2021 Resolved
Each vessel must be fitted with a compass suitable for the intended service of the vessel. Vessel's magnetic compass was determined to be at least 10 degrees off after checking against the vessels other onbaord equipment. Have compass corrected to satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 23 August 2021
Resolution: Compass corrected to satisfaction of attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 17 August 2021 Resolved
Employers must ensure that they and their crew members meet the requirements of Part 16 - Chemical Testing. Employees were not able to provide any proof of enrollment in the vessel's chemical testing program. Provide proof of crew members enrollment in chemical testing program from employer/consortium to attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 23 August 2021
Resolution: Provided proof of crew members enrollment in chemical testing program from employer/consortium to attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2021 Resolved
Lifebuoy must be fitted with a buoyant lifeline that is of a breaking strength which is not less than 1,124 pounds-force. Grab line on port bridge wing lifebuoy was found wasted. Proof strength or replace as per regulation and to attending Marine Inspectors satisfaction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 23 August 2021
Resolution: Replaced grab line as per regulation and to attending Marine Inspectors satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2021 Resolved
The self-igniting light must be approved under approval series 46 CFR 161.010 and must be attached to the buoyant apparatus or lifefloat by a 12-thread manila or equivalent lanyard that is at least 5.5 meters (18 feet) long. This lanyard (found on self-igniting light forward of wheelhouse) was found wasted. Replace to satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 23 August 2021
Resolution: Replace lanyard to satisfaction of attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 July 2020 Resolved
Vital systems that are automatically or remotely controlled must be provided with instrumentation to monitor system parameters. Vessel was unable to to demonstrate function of safety shutdowns and alarms for the MDEs, SSDGs, and bow thruster high cooling water temp alarm, overspeed, and low lube oil pressure. Demonstrate proper operation of shutdowns and alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 31 July 2020
Resolution: Sector LA/LB inspector witnessed tests of alarms and shut downs.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 July 2020 Resolved
VHF DSC radios are not provided with MMSI and GPS. Provide compliant VHF DSC radios.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 29 July 2020
Resolution: Vessel programmed MMSI and provided GPS to DSC VHF radios.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 July 2020 Resolved
Captive chains not connected to steering and engine room escape hatches. Connect captive chains.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 29 July 2020
Resolution: Vessel provided captive chains for both hatches.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 May 2019 Resolved
Provide 11 additional immersion suits for a total of 31; Vessel restricted to 20 persons on board when operating north of 32 degrees north latitude.
Action required: 705 - Other - as specified
Resolved 19 June 2019
Resolution: Additional suits provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2019 Resolved
Properly mark storage location of life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 19 June 2019
Resolution: Stowage marked.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 May 2019 Resolved
Properly mark location of fuel oil shutoff valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 19 June 2019
Resolution: Valves labeled.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 30 May 2019 Resolved
Update Safety (Fire) plan and submit for approval to include 31 lifejackets and 31 immersion suit locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 22 July 2019
Resolution: Approved amended Safety (Fire) Plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2019 Resolved
Properly wire alarm systems on main and auxiliary machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 19 June 2019
Resolution: Alarm systems properly wired.
Engineering › Fuel Oil Service System › Valve, Control
Issued 31 May 2018 Resolved
Label remote fuel shutoff valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 July 2018
Resolved 25 June 2018
Resolution: Labled
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 31 May 2018 Resolved
Prove operation of low L/O and overspeed shutdowns, high J/W temp alarms for BMDE, BSSDG, and BT.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2018
Resolution: Tested SAT
Construction/Loadline › Structures › Transverse Bulkhead
Issued 31 May 2018 Resolved
Replace compression block for MCT in ER FWD BLKHD.
Action required: 705 - Other - as specified
Due 1 July 2018
Resolved 25 June 2018
Resolution: Repaired
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 May 2018 Resolved
Complete drills
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2018
Resolution: Drills Conducted
Navigation › Collision/Grounding Avoidance › Transponder
Issued 31 May 2018 Resolved
Prove proper operation of AIS
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2018
Resolution: Working Properly
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 May 2018 Resolved
Update fire control plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 25 June 2018
Resolution: UPDATED and submitted to OCMI for approval
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 31 May 2018 Resolved
Provide DAPI program manual
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 25 June 2018
Resolution: Manual on board
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2018 Resolved
Update/replensish first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 25 June 2018
Resolution: New kit on board
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 31 May 2018 Resolved
Update NTVRP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 25 June 2018
Resolution: UPDATED
Construction/Loadline › Structures › Scupper
Issued 31 May 2018 Resolved
Repair hole in scuttle and remove shore tie from penetration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2018
Resolution: Repaired
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Number
Issued 21 April 2017 Resolved
Prior to carriage of grade D or lower flammable or combustable cargos; install B-V semi-portable fire extinguisher.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: B-V installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 April 2017 Resolved
Provide hydro test results of CO2 extinguisher on the bridge.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: Extinguisher passed hydro test.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 21 April 2017 Resolved
Provide copy of NOI for VGP.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: NOI provided.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 April 2017 Resolved
Clean up gear adrift in E/R.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: E/R gear cleaned up.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 21 April 2017 Resolved
Provide rescue platform.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 12 May 2017
Resolution: Rescue ladder provided on board.
Construction/Loadline › Structures › Superstructure
Issued 23 February 2017 Resolved
Repair 3 window seals above pilot house aft operating station.
Condition: Improper/Lack of Maintenance
Due 23 March 2017
Resolved 3 March 2017
Resolution: 04 aft operating station window frames were cropped and renewed.
Engineering › Steering Gear System › Ram Seal
Issued 23 February 2017 Resolved
Evaluate and repair as needed the stbd steering ram during sea trial with CG marine inspector.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 28 February 2017
Construction/Loadline › Structures › Superstructure
Issued 23 February 2017 Resolved
Repair hole in house behind main deck door.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 28 February 2017
Engineering › Compressed Air System (start air) › Valve
Issued 23 February 2017 Resolved
Demonstrate proper operation of air tank relief valves in place.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 28 February 2017
Stability › Incline Test › General
Issued 1 August 2016 Resolved
Vessel to provide stability calculations for addition of A frame crane
Due 31 October 2016
Resolved 27 October 2016
Resolution: re-issued
Stability › Incline Test › General
Issued 1 August 2016 Resolved
Provide an updated stability letter and/or stability book approved by MSC showing installation of the a-frame crane on the stern.
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 15 December 2016
Resolution: VESSEL REMOVED A-FRAME FROM VESSEL
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 7 July 2016 Resolved
Submit A-frame plans to MSC for approval prior to operating the equipment.
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 1 August 2016
Stability › Intact Stability (when using lifting gear) › General
Issued 7 July 2016 Resolved
Once A-frame design is approved by MSC, complete design verification and system testing in the presence of MI prior to operation of A-Frame.
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 1 August 2016
Engineering › Lubricating Oil Service System › Hose
Issued 7 July 2016 Resolved
Make proper repairs to hydraulic hose and complete a pressure test.
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 1 August 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 April 2016 Resolved
Replace (3) batteries for life ring(s).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 22 August 2016
Resolution: NEW BATTERIES INSTALLED
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 April 2016 Resolved
PLace machinery guard for starboard winch system for the four-point mooring system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 22 August 2016
Resolution: Guard on winch installed
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 15 April 2016 Resolved
Lock the sewage overboard discharge valve to prevent accidental discharge.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 15 April 2016
Resolution: Discharge valve properly locked.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 April 2016 Resolved
Ship name labels severely faded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 15 April 2016
Resolution: Lifebuoy labels renewed with permanent ink.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 25 June 2014 Resolved
Show proof of OSRO for Cook Inlet or include Western Alaska to VRP Interim Operating Authorization.
Due 30 June 2014
Resolved 25 June 2014
Resolution: Company was able to show proof of OSRO for Cook Inlet - Corrected on the spot.
Lifesaving › Line-Throwing Appliances › Lines
Issued 25 June 2014 Resolved
Provide one additional service line @ 600' & one auxilliary line @ 500' for shoulder gun line throwing device.
Due 4 July 2014
Resolved 4 July 2014
Resolution: Proof of items needed shown.
Stability › Watertight Integrity › General
Issued 25 June 2014 Resolved
Renew or replace gasket on each watertight door in engine room.
Due 17 July 2014
Resolved 17 July 2014
Resolution: Replaced incorrect gasket material.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 25 June 2014 Resolved
Remove old H2S monitoring electrical wiring in way of bow thruster prime mover.
Due 17 July 2014
Resolved 17 July 2014
Resolution: Removed.
Fire Fighting › Fire Hoses › Connections
Issued 25 June 2014 Resolved
Permanently affix spanner wrenches for hoses @ each fire station.
Due 26 June 2014
Resolved 26 June 2014
Resolution: Spanner wrenches affixed by pieces of line.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 27 July 2011 Resolved
Port air receiver missing information plate. Previous name plate missing and could not be located. Provide new air receiver at next dry-docking.
Action required: 705 - Other - as specified
Due 6 February 2012
Resolved 17 April 2012
Resolution: Vessel installed new pressure vessel for port side. Serial # 686274 MAWP 200 psi
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 23 June 2008 Resolved
outboard aft chockfast on port main engine is cracked. Renew chockfast.
Due 23 July 2008
Resolved 19 June 2009
Resolution: While conducting the COI it was noted that the chockfast had been repaired and the requirement not cleared.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 25 June 2003 Resolved
Demonstrate proper operation of engineroom shut downs and alarms on Port and Starboard main engine.
Due 25 July 2003
Resolved 16 September 2003
Resolution: [name withheld] electrical attended vessel with CG and demonstrated all alarms and shutdowns.
Engineering › Diesel Engine (auxiliary)
Issued 25 June 2003 Resolved
demonstrate proper operation of port and starboard generator set prime mover shutdowns.
Due 25 July 2003
Resolved 16 September 2003
Resolution: [name withheld] electric was onboard with CG to demonstrate all alarms and shutdowns.
Documentation › Logs/Records
Issued 25 June 2003 Resolved
Conduct and log required drills and inspections in accordance with part 131, subpart E of 46 CFR subchapter L. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Due 25 July 2003
Resolved 16 September 2003
Resolution: Vessel has started new drill log.
Operations/Management › Navigation Safety
Issued 25 June 2003 Resolved
Provide updated charts. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 25 July 2003
Resolved 16 September 2003
Resolution: Vessel has been supplied with new charts.
Operations/Management › Navigation Safety
Issued 25 June 2003 Resolved
Provide and retain as required, Local notice to mariners for area of operation. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 25 July 2003
Resolved 16 September 2003
Resolution: All local notice to Mariners are on board.

Casualty record · 3

23 February 2009Routine · role: Involved in a Marine Casualty · activity 3440153
7 July 2016Routine · role: Acknowledged Pollution Source · activity 5979957
1 December 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7616430
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.