← All vessels
DAKOTA
Offshore Supply Vessel · Offshore class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named DAKOTA
DAKOTA is a 1999 offshore supply vessel. The Coast Guard has recorded 35 inspections since 1999, most recently in June 2024, along with 18 deficiencies and 1 operational control.
Records from 1999 to 2024. Most recent: inspection, 12 June 2024.
- Built
- 1999
- Last inspected
- 12 June 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1077124
9207601 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
XCRF7
489947
Flag
MEXICO
303149000 (licence lapsed)
Maury page id
psix-489947
Inspections, by type
…with no type recorded3
Years with a record
15 calendar years (1999–2024)
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it1226 - Convention (Subpart B), Gross Ton
367 - Convention (Subpart B), Net Ton
367 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WCY8949MMSI 303149000 · cancelled · compulsorily equipped · granted 10 January 2009, cancelled 10 August 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 35
12 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7933330
3 October 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6014660
4 June 2014
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4879696
24 February 2012
ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4250676
8 July 2009
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3528300
15 April 2009
Administrative Inspection · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3452932
28 July 2008
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3282277
21 June 2007
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2969010
7 May 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2924187
26 April 2007
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2916439
4 April 2007
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2904575
28 February 2007
Internal Structural Exam · Hull Examination · Administrative Inspection · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2879253
26 May 2006
COI Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2639938
31 January 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2576499
31 January 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2576507
4 January 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2569563
13 September 2005
Re-Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2491588
28 May 2004
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2115257
20 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2048373
23 March 2004
Annual Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2029650
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979369
1 July 2003
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1856587
14 January 2003
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1730177
9 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1673195
23 August 2002
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1665314
22 January 2002
Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1480191
30 November 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1077376
31 May 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366375
9 September 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 824761
28 August 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413774
20 December 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 89919
18 July 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 58286
8 July 1999
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1092478
2 June 1999
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 821988
2 June 1999
Initial Construction-Excluding Oversight · Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1388745
Deficiency record · 18
Documentation › Certificates/Documents › IOPP Certificate
Issued 4 June 2014
Resolved
AN IOPP CERTIFICATE SHALL BE ISSUD TO ANY SHIP OF 400 GT AND ABOVE. IOPP FORM WAS MUST BE UPDATED TO LIST THE VESSEL HAS ON BOARD A MEP.60(33) OILY WATER SEPARATOR.
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 24 February 2012
Resolved
Could not produce LRIT Conformance Test Report during inspections. Provide proof of LRIT prior to departure.
28FEB12: Vessel still does not have LRIT Conformance Test Report. Vessel must provde a Flage State approved corrective action plan. The corrective action plan was provided on the spot and the vessel is clear to depart U.S.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 24 February 2012
Resolved
Could not produce IAPP Cert during inspection. Provide IAPP Certificate prior to departure.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 February 2012
Resolved
Generator #1 circuit breaker does nnot close. Awaiting part "sync selector switch" to arive next Wednesday (29FEB12). Demonstrate proper operation of GEN#1 prior to departure.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 February 2012
Resolved
Chief Engineer could not demonstrate proper operation of OWS b/c vessel discharged all bilge during inport. Demonstrate proper operation of OWS prior to departure.
Communications › Long Range Identification and Tracking (LRIT) › Software Package Update
Issued 8 July 2009
Resolved
Provide verification of LRIT installation
Lifesaving › Rescue Boat › Propulsion Engine
Issued 8 July 2009
Resolved
Provide FRC maintenance manual, perform required maintenance iaw manual, implement FRC engine maintenance into lifesaving maintenance record.
Communications › Public Address System › Loudspeaker
Issued 8 July 2009
Resolved
Provide additional speakers on to service all normally manned spaces
Communications › Public Address System › Audio Distribution System Silencing
Issued 8 July 2009
Resolved
Demonstrate proper operation of Gen Alarm/PA interupt iaw SOLAS.
Electrical › Electrical Distribution System (service) › Cable
Issued 8 July 2009
Resolved
Remove unapproved wiring from bridge area servicing refrigerator and coffee pot.
Lifesaving › Launching Appliances › Davit
Issued 8 July 2009
Resolved
Demonstrate proper operation of FRC Davit
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 July 2009
Resolved
Demonstrate proper operation of alarm and light for light failure for Lower NUC light. All other alarms were working properly with the exception of this one light
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 8 July 2009
Resolved
Provide Flame Safety Lamp or O2 Depletion Meter.
Stability › Watertight Integrity › General
Issued 8 July 2009
Resolved
Several WTD's were unable to open easily due to lack of maintenance. Perform maintenance on all WTD's and demonstrate proper operation.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 April 2007
Resolved
Prove proper operation of Oily Water Separator.
Documentation
Issued 28 August 2000
Resolved
PROVIDE UPDATED FIRE SAFETY PLAN FOR APPROVAL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Lifesaving
Issued 2 June 1999
Resolved
PROVIDE THERMAL PROTECTIVE DEVICES FOR THE CREW IAW SOLAS.
Lifesaving
Issued 2 June 1999
Resolved
PROVIDE IMMERSION SUITS FOR THE RESCUE BOAT CREW IAW SOLAS CHAPTER III.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.