13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2025
Resolved
All unfired pressure vessels meet the applicable requirements of Subchapter F (Marine Engineering) of this chapter. The spring in a relief valve in service for pressures up to and including 250 pounds per square inch must not be reset for any pressure more than 10 percent above or 10 percent below that for which the relief valve is marked. The safety relief valve for the vessel's air receiver could not be tested.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 22 September 2025
Resolution: Satisfactorily tested the safety relief valve for the pressure vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2025
Resolved
A means of escape which is not readily apparent to a person from both inside and outside the space must be adequately marked in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”. Markings for the emergency exits from the lower berthing and engine room spaces were either incomplete or missing entirely.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 22 September 2025
Resolution: All means of escape hatches are properly marked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 September 2025
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Securing devices were missing from the forward void, aft port, center, and starboard voids, and engine room escape hatches.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2025
Resolved 22 September 2025
Resolution: All deck hatches have been fitted with securing devices.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 September 2025
Resolved
Each lighting fixture, globe, lens, or diffuser must have a guard or be made of high strength material. The protective cover for two fluorescent lighting fixtures in the engine room and one in the galley could not be properly secured and a nighttime/red light bulb in the lower berthing space was not fitted with a guard/cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2025
Resolved 1 October 2025
Resolution: The identified lighting fixtures have been secured by latches.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2025
Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. The vessel's two fire hoses were found to be deteriorated/inoperable and the nozzle was seized on one of the hoses.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2025
Resolution: New hoses and nozzles have been installed on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct annual maintenance and recharging of extinguishers. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Two of the vessel's required portable fire extinguishers have not been serviced in more than one year.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2025
Resolution: All portable fire extinguishers required by the COI have been serviced within the last year.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 July 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire, caused by or originating in electrical equipment, and electrical shock. Numerous dead end or loose wires were found under the operating station console.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2025
Resolution: All electrical hazards noted under the operating station console have been rectified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 July 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil that might create a fire hazard. Standing oil was noted inside the port main diesel engine fuel filter flame shield.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 9 September 2025
Resolution: Standing oil was removed from the fuel filter flame shield.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2025
Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. A suitable metal marine type strainer must be fitted in the fuel supply line in the engine compartment. One of the fuel filters for the crane's diesel engine was fitted with a plastic petcock.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 9 September 2025
Resolution: The fuel filter is now fitted with a metal petcock.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 July 2025
Resolved
A vessel on an oceans route must carry six hand red flare and six hand orange smoke distress signals. The vessel could only produce three hand red flare distress signals.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 9 September 2025
Resolution: The vessel now maintains on board the correct amount of each type of distress signal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2025
Resolved
Each lifeline on a ring life buoy must be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. The lifeline connected to the ring buoy on the starboard side of the pilot house was found to be deteriorated. Additionally, the ring buoy's retro-reflective tap was found to be deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 9 September 2025
Resolution: A new lifeline has been connected to the identified ring buoy and new retro-reflective tape applied.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 8 July 2025
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. The protective cover over one of the light fixtures in the galley could not be secured.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2025
Resolved 9 September 2025
Resolution: This deficiency is cleared and a new one with additional light fixture issues was issued during the 09SEP2025 COI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 July 2025
Resolved
A marine employer shall comply with the requirements of 46 CFR 4.06 and must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a Serious Marine Incident. The alcohol testing devices maintained on board expired in 2023.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 9 September 2025
Resolution: Numerous alcohol testing devices, with an expiration date in 2026, have been delivered to the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 July 2025
Resolved
A vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication, Coast Guard Light List, and tide tables. The Coast Guard Light List was not maintained on board and the U.S. Coast Pilot and tide tables were found to be outdated.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 9 September 2025
Resolution: Updated navigation publications are now maintained in the pilot house.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Vessel rep reported that the port MDE sustained a cracked exhaust manifold and not operating as designed. Vessel is to make repairs as needed and complete satisfactory sea trial with marine inspector prior to departing Sector Miami AOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2025
Resolved 24 June 2025
Resolution: Completed repairs as required, and conducted satisfactory sea trials.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 May 2025
Resolved
Each survival craft must be:Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Both port and stbd life floats painter lines were not correctly attached to the weak link. Correct on the spot.
Action required: 10 - Deficiency Rectified
Due 3 June 2025
Resolved 3 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2024
Resolved
All engines must have at least two means for
stopping the engines under any operating
conditions. The fuel oil shut off required at the engine
by 185.455(b)(4) will satisfy one means of stopping
the engine. Port main engine needs air dampener
repair so it will close fully and shutdown engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 28 May 2024
Resolution: Port engine air dampner emergency shutdown has been repaired and tested SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 June 2023
Resolved
The items contained in the first aid kit shall be as listed in table 160.041(b). Splint, wire missing from kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 8 July 2025
Resolution: The vessel maintains a full complement of first aid equipment on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2023
Resolved
Placards containing instructions for the donning and use of the life jackets on board the vessel must be posted. Renew life jacket donning placard to life vests on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 27 June 2023
Resolution: Updated placard.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 June 2023
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 27 June 2023
Resolution: Installed emergency broadcast instructions.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2022
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanane ttype connectros.
Both Port and STBD main batteries had wing nut type connectors.
46 CFR 183.05-20(c)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2022
Resolution: Submitted photos of correct terminal nuts on batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2022
Resolved
Wiring joints and splices shall be of the mechanically secure and made in junction boxes.
Mulitiple wires were spliced together with wire nuts under the wheel house navigation panel, hydraulic work tank in engine room and on STBD main engine.
46 CFR 183.05-50(b)(1)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2022
Resolution: Wiring was cleaned up and removed all wire nuts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2022
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating.
Port main engine had zip ties holding linkage together.
46 CFR 182.05-1(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2022
Resolution: Port Main engine linkage was corrected with proper hardware
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections.
Remove dead end wires under wheel houst navigation panel and above port main engine.
46 CFR 182.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2022
Resolution: All wiring was cleaned up and dead end wires were removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2021
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. The sea suction valve on the secondary bilge pumping configuration (ballast manifold) was not secured. Secure valve onto valve stem with nut.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 7 July 2021
Resolution: Vessel proved operational capability by pumping water from #3 fresh water tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2021
Resolved
All engines must have at least two means for stopping the engine(s) under any operating conditions. The means of stopping engines from the bridge would not fully shut down the main propulsion engines, leading the engines to continue breathing and running at a low rpm. Install suitable means to completely shut down both main propulsion engine from the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2021
Resolved 7 July 2021
Resolution: Vessel found wiring discrepancies as well as missing intake gaskets from repairs during dry dock. Corrected issues and proved satisfactory performance and shutdown.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2021
Resolved
Safety and relief valves for air service shall be provided with a substantial lifting device so that the disk can be lifted from its seat when the pressure in the vessel is 75 percent of that at which the valve is set to blow. Inspector could not lift the relief valve disc at a pressure of 150 psi. Renew pressure relieving device.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2021
Resolved 28 June 2021
Resolution: POC provided video of the sat. operational test of the pressure relief valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2021
Resolved
Each battery must be secured to protect against shifting with the roll and pitch of the vessel. The starboard engine room battery bank was not secured against shifting or rolling within the box. Install dunnage or other non-conductive material to prevent against shifting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Vessel installed dunnage in battery tray
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2021
Resolved
The general construction of the vessel must be such as to minimize fire hazards. Inspector found the dryer vent duct hose separated allowing lint to enter the machinery space. Replace duct hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Installed new dryer vent hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2021
Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Installed hose clamps
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 June 2021
Resolved
Each overnight accommodation space on a vessel with overnight accommodations must be fitted with an independent modular smoke detection and alarm unit IAW 46 CFR 181.450. Marine Inspectors observed that the lower berthing arrangements in the vessel did not have an installed modular smoke detection unit. Install a modular smoke detector in the space to the satisfaction of the attending Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Installed smoke detector
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 June 2021
Resolved
Doors on a cooking appliance must be provided with hinges and locking devices to prevent accidental opening in heavy seas. The oven door did not have a means to prevent the door from opening in heavy seas. Effect permanent repair to the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Installed locking device
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Marine Inspectors observed that the refrigerator in the galley was not permanently secured to the deck, or the bulkhead. Permanently secure the refrigerator to the deck, or bulked head to the satisfaction of the attending Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Secured refrigerator
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2021
Resolved
The frame or support of each semi-portable fire extinguisher must be welded or otherwise permanently attached to a bulkhead or deck. Marine Inspectors observed one portable fire extinguisher on the bridge and one portable fire extinguisher in the accommodation space that were not mounted to the bulkhead, or deck. Permanently install the portable fire extinguishers to the satisfaction of the attending Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Removed portable extinguishers not required by COI.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 25 June 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and publications. Marine Inspectors observed that the U.S. Coast Pilot and Coast Guard Light List were the 2020 edition. Acquire the 2021 editions and place them on board the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Provided up to date Coast Pilot and Light List
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2021
Resolved
Portable and semi portable extinguishers must be inspected and maintained IAW NFPA 10. Where manual inspections are conducted, records for manual inspections shall be kept on a tag or label attached to the fire extinguisher, or an inspection checklist maintained on fire. Marine Inspectors did not observe monthly inspection documentation for the portable fire extinguishers. Provide a corrective action to carry out and document monthly inspections for portable and semi portable fire extinguishers on the vessel to the satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Provided maintenance log
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2021
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. The alcohol test strips were expired. Acquire a suitable number of new alcohol test strips to be placed on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Provided up to date test strips
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 25 June 2021
Resolved
Each EPIRB must be tested monthly using the integrated test circuit and output indicator to determine that it is operative. The EPRIB test required shall be logged or otherwise documented. The operator could not provide proof of documentation of the monthly test of the EPRIB. Provide means to document the monthly test of the EPIRB and conduct monthly test for JUN 2021 to the satisfaction of the attending Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Provided log
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 June 2021
Resolved
A vessel must carry either a first-aid kit approved IAW 46 CFR 160.041, or a kit with equivalent contents and instructions. A first-aid kit must be easily be easily visible and readily available to the crew. The first-aid kit on the bridge and the medical chest in the crew accommodations were expired. Acquire and place on board at least one new suitable first-aid kit on the vessel to the satisfaction of the attending Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 7 July 2021
Resolution: Provided new first aid kit
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2021
Resolved
A vessel must have one more life buoys be approved IAW 46 CFR 160.50 in Sub-chapter Q. The grab line shall encircle the buoy and shall be held in place by beckets. Marine Inspectors observed that the grab line for the starboard side life buoy aft of the pilot house had apartially severed grab line. Replace the line, or life buoy to the satisfaction of the attending Marine Inspectors.
Action required: 10 - Deficiency Rectified
Due 25 June 2021
Resolved 25 June 2021
Resolution: The life buoy was entirely replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2020
Resolved
No conducting mats or grating must be provided on the deck in front of each switchboard and, if accessible from the rear, on the deck in the rear of the switchboard. Vessel must provide satisfactory evidence of mat meeting the no conducting standards to the satisfaction of the MI.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2020
Resolved 9 June 2020
Resolution: Vessel submitted photo of mat meeting ASTM standards
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2020
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Flexible hose on the center diesel generator was not labeled. Vessel must provide satisfactory evidence of J-1942 standards to the satisfaction of the MI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2020
Resolved 9 June 2020
Resolution: Vessel submitted photos of newly installed J-1942 hose.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2020
Resolved
A vessel's hull must not carry current as a conductor. The switchboard displayed a ground. Vessel must rectify the ground to the satisfaction of the attending MI.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2020
Resolved 17 June 2020
Resolution: Vessel submitted tech report attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2020
Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective switchboard that provides continuous indication of circuit status to ground with a provision to momentarily remove the indicating device from the reference ground. MI's discovered that continuous indication status was not able to be removed. Vessel must meet the intent of the regulation to the satisfaction of the attending MI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2020
Resolved 17 June 2020
Resolution: Vessel submitted tech report attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 June 2020
Resolved
Vessel is required to have 6 red flare distress signals. MI's discovered that all of the red distress signals had expired May 31, 2020. Vessel must obtain proper amount of distress signals to the satisfaction of the MI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2020
Resolved 9 June 2020
Resolution: Vessel provided photos of new red and hand flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2020
Resolved
Vessel must have three ring life buoys of not less than 24 inches in diameter with beckets for securing the grab line. Beckets are worn and must be replaced to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2020
Resolved 9 June 2020
Resolution: Vessel provided photo of new life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2019
Resolved
Life jacket must be approved in accordance with either 160.002, 160.005, or 16160.055 in sub-chapter Q. 08 life jackets had deteriorated to the point where thy were no longer acceptable to the attending [name withheld] will replace the 08 life jackets immediately identified and submit a plan/time line to MSU Texas City for replacing the remaining life jackets, which were deemed questionable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2019
Resolved 3 May 2019
Resolution: 22 new life jackets were aquired to replace the old life jackets.