MAURY USCG vessel records Sign in
← All vessels

GENCO ACHERON

GENCO ACHERON is a 1999 freight ship. The Coast Guard has recorded 21 inspections since 1999, most recently in January 2016, along with 7 deficiencies and 7 operational controls.

Records from 1999 to 2016. Most recent: operational control imposed, 6 January 2016.

Built
1999
Last inspected
6 January 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9176711 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
490080
Flag
HONG KONG
—
Maury page id
psix-490080

Inspections, by type

…with no type recorded9
Years with a record 13 calendar years (1999–2016)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it37695 - Convention (Subpart B), Gross Ton
24141 - Convention (Subpart B), Net Ton
72495 - Dead Weight, Metric Ton
82658 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

6 January 2016 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5792329
16 October 2015 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5739986
13 May 2014 Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4856323
21 December 2010 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3914114
26 February 2010 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3687698
24 February 2010 Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3685135
18 December 2008 ISPS I Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3378693
17 December 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3379020
20 May 2007 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2935051
28 January 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2863036
10 November 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2532597
26 September 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2501880
1 November 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2231860
2 October 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1919392
5 December 2002 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1715103
28 August 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1667813
28 February 2002 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1490297
16 June 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291095
17 October 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 283231
10 March 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 275214
8 February 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 425464

Deficiency record · 7

Operations/Management › Drills/Instruction › Fire
Issued 24 February 2010 Resolved
Port State Control Officers conducted 2 fire drills and an abandon ship drill. Both fire drills were considered unsatisfactory. The fire team is unfamilar with their equipment, specific duties, and fire fighting tactics. The crews inability to demonstrate proper fire fighting poses a hazard to the vessel and crew, due to the inability of the crew to extinguish or prevent the spread of a fire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2010
Resolution: Received class report attesting to satisfactory completion of a fire drill.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 24 February 2010 Resolved
The inability of the crew to successfully demonstrate proper fire fighting procedures indicates a major non-conformity in way of vessels safety management system. Request an external audit be conducted prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2010
Resolution: Received confirmation from the RO that an external audit was completed.
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 24 February 2010 Resolved
04 Chemical suits are missing which are required to be onboard. Class to verify required suits are onboard prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2010
Resolution: Received class report attesting to delivery of 4 Chemical suits.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 24 February 2010 Resolved
Vessel is required to have 04 working SCBA's onboard. Currently only 03 are working as designed. Class to verify prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2010
Resolution: Received class report attesting to delivery of a new SCBA and proper operation of all 4.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 24 February 2010 Resolved
Maryland pilot informed USCG that vessel lost propulsion during iut's out-bound transit of COTP zone Baltimore. C/E reported water in the fuel lines/propulsion system. LR class surveyor will attend vessel to attest to the cause of loss of propulsion and proper repairs of the vessel's main propulsion system.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2010
Resolved 26 March 2010
Resolution: Attended vessel with class. Main propulsion was lost due to the Claifier being turned on instead of the Purifier. This enabled water that was mixed with the fuel to enter the main engine. Main propulsion tested sat.
Navigation › Piloting/Steering › Gyro Compass
Issued 10 November 2005 Resolved
Vessel's Gyrocompass became inoperable when the vessel arrived at the Pilot Station. Master verball requested a Letter of Deviation and made formal request once moored. Due to unavailability of parts, gyrocompass was not repaired in Point Comfort. Master requested a Letter of Deviation to depart the Port of Point Comfort with the inoperable gyrocompass.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 November 2005
Resolved 14 December 2005
Resolution: Received Technician''s Report #3005S13652. Gyrocompass was repaired in by Alphatron in Rotterdam and tested satisfactorily.
Documentation
Issued 17 October 2000 Resolved
Garbage record book entries not correct. Catagories entered as A,B,or C, Catagories need to be 1-5. Vessel also not logging discharge of category 1,plastics. According to log, no plastic was discharged for 9 months. Correctand maintain log book prior to next US port. MARPOL 73/78 AnnexV
Condition: Unknown
Due 21 December 2000
Resolved 21 December 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.