MAURY USCG vessel records
← All vessels

ISLAND VIC

ISLAND VIC is a 1976 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2016, most recently in January 2024, along with 44 deficiencies — 6 with no resolution recorded —, 3 operational controls and 1 casualty investigation in 2003.

Records from 2003 to 2024. Most recent: inspection, 2 January 2024.

Built
1976
Last inspected
2 January 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 January 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH5316
Flag
UNITED STATES
Maury page id
psix-49011

Documentation record

Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

2 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7844508
17 July 2017 Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6208622
13 June 2017 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6173270
16 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6148219
15 March 2017 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6104602
8 August 2016 In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5967340
2 May 2016 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5894466

Deficiency record · 44

Construction/Loadline › Hull › Bottom Plating
Issued 20 July 2017 No resolution recorded
Work List: 3 holes found in bottom plating in way of starboard rudder. Crop and renew plate.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Bottom Plating
Issued 17 July 2017 Resolved
Work List: Crop and renew wasted metal on both aft corners of vessel. Expose internal baffles and transom plate in stern void until good metal is reached and crop and renew wasted plate as needed.
Action required: 705 - Other - as specified
Resolved 14 August 2017
Resolution: Cropped and renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 July 2017 No resolution recorded
Work list: Replaced wasted railing port side midship
Action required: 705 - Other - as specified
Engineering › Bilge Water Management System › Piping
Issued 17 July 2017 Resolved
Work List: Replace wasted bilge pickup piping in port side lazarette.
Action required: 705 - Other - as specified
Resolved 14 August 2017
Resolution: Bilge pickup piping replaced and verified.
Construction/Loadline › Hull › Transverse Frame
Issued 17 July 2017 Resolved
Work List: Crop and renew wasted angle beams in space aft of superstructure, second to aft bay, keel stiffeners.
Action required: 705 - Other - as specified
Resolved 14 August 2017
Resolution: Angle beams replaced.
Construction/Loadline › Hull › Bracket
Issued 17 July 2017 No resolution recorded
Work List: Replace pad eyes on vessel bulwarks aft where ramp safety chains attach due to elongation of pad eye holes.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Bracket
Issued 17 July 2017 No resolution recorded
Work List: Replace ramp hinges
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Stiffener
Issued 17 July 2017 Resolved
Work List: Replace wasted transverse flat bar stiffeners on ramp.
Action required: 705 - Other - as specified
Resolved 14 August 2017
Resolution: Replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 17 July 2017 Resolved
Work List: Replace wasted flange on transverse support in way of starboard rudder support assembly in starboard lazarette.
Action required: 705 - Other - as specified
Resolved 14 August 2017
Resolution: Replaced.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 July 2017 No resolution recorded
Work List: Provide specifications on existing and replacement shafts, propellers, and bearings.
Action required: 705 - Other - as specified
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 July 2017 No resolution recorded
Work List: Provide information for repowering, including HP. RPM and Weight for both existing and replacement engines.
Action required: 705 - Other - as specified
Engineering › Bilge Water Management System › Not Operational
Issued 13 June 2017 Resolved
Demonstrate proper operation of bilge system to include all bilge pickups, manifold labelling, and crew knowledge prior to carrying passengers or cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2017
Resolved 13 June 2017
Resolution: Vessel showed system operation.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 June 2017 Resolved
Demonstrate proper operation of all bilge high level alarms prior to carrying passengers or cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2017
Resolved 13 June 2017
Resolution: Vessel showed system operation.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 June 2017 Resolved
Remove excess oil from all bilge wells prior to carrying passengers or cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2017
Resolved 13 June 2017
Resolution: Vessel pumped bilges.
Engineering › Bilge Water Management System › Interface Detector
Issued 15 March 2017 Resolved
Remove excess oil and water in engine room bilge and show proper operation of bilge high level alarm. High level alarm was found disabled in the "off" position.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2017
Resolved 16 March 2017
Resolution: Liquid disposed of and bigle high level alarm tested.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 March 2017 Resolved
Provide current registration or documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2017
Resolved 16 March 2017
Resolution: Vessel provide current COD.
Communications › Radio Communications › EPIRB
Issued 15 March 2017 Resolved
Provide current NOAA EPIRB registration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2017
Resolved 16 March 2017
Resolution: Vessel provided EPIRB registration certificate.
Fire Fighting › Fire Main › Condition
Issued 15 March 2017 Resolved
Crop and renew fire main where bolt slug is inserted.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 16 March 2017
Resolution: Vessel cropped and renewed piping.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 March 2017 Resolved
Provide complete and current first aid kit.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 16 March 2017
Resolution: Vessel provided new first aid kit.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 15 March 2017 Resolved
Show proper operation of port emergency lighting,
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 16 March 2017
Resolution: Vessel showed operation.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 15 March 2017 Resolved
Replace starboard outboard engine exhaust lagging.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 29 March 2017
Resolution: Vessel reinstalled lagging.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 March 2017 Resolved
Provide cover for battery box.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 16 March 2017
Resolution: Vessel provided cover.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 March 2017 Resolved
Remove excess batteries or provide battery box.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 16 March 2017
Resolution: Vessel removed batteries.
Lifesaving › Lifefloat › Paddle
Issued 15 March 2017 Resolved
Provide and secure paddles for all life floats.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 16 March 2017
Resolution: Vessel provided paddles.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 15 March 2017 Resolved
Slow excess water ingress from port shaft packing.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 29 March 2017
Resolution: Vessel tightened shaft seals.
Fire Fighting › Fire Pumps › Power Source
Issued 22 November 2016 Resolved
CG-835s issued 08NOV16 and due 15NOV16 were not rectified. Vessel is prohibited from carrying passengers or cargo until CG-835s #'s 1, 3, 4, 7, 13, & 16 are corrected.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 November 2016
Resolved 23 November 2016
Resolution: Required fire pump operation demonstrated.
Documentation › Certificates/Documents › Stability Letter
Issued 9 November 2016 Resolved
During inspection it was noted that vessel regularly carries additional vehicles of lesser weight, and regularly utilizes the ballast tank to control trim due to draft restrictions. Prior to due date, submit to USCG MSC request for resolution by amending current stability letter based on previous calculations or submitting procedures for new stability calculations to reflect intended vsl operation
Action required: 705 - Other - as specified
Due 9 December 2016
Resolved 16 May 2017
Resolution: Revised stability letter issued by MSC.
Fire Fighting › Fire Pumps › Power Source
Issued 8 November 2016 Resolved
Replace belt and demonstrate operation of port inboard fire pump.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 17 January 2017
Resolution: Witnessed satisfactory operation of pump.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 8 November 2016 Resolved
Replace missing exhaust lagging on port outboard main engine.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 23 November 2016
Resolution: Lagging replaced.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 November 2016 Resolved
Repair or replace louver on port exhaust.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 23 November 2016
Resolution: Louver operation demonstrated.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 November 2016 Resolved
Close openings and show integrity of port engine room exhaust ducts.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 7 December 2016
Resolution: Engine room fire dampners operation and integrity demonstrated.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 November 2016 Resolved
Replace missing globes and guards on engine room lighting fixtures.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 22 November 2016
Resolution: Globes and guards installed.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 8 November 2016 Resolved
Make generator battery charging cable permanent installation.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 22 November 2016
Resolution: Batteries made permanent installation.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 November 2016 Resolved
Properly secure portable air compressor on starboard side of engine room.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 17 January 2017
Resolution: Inspected installation of new air compressor.
Communications › Radio Communications › EPIRB
Issued 8 November 2016 Resolved
Complete EPIRB testing log for tests every 30 days.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 22 November 2016
Resolution: EPIRB log established and completed.
Communications › Public Address System › Loudspeaker
Issued 8 November 2016 Resolved
Show proper operation of loud hailer/public address system.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 22 November 2016
Resolution: PA system showed operational.
Documentation › Markings/Placards › Garbage Placard
Issued 8 November 2016 Resolved
Replace garbage placard with current one.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 22 November 2016
Resolution: New placard provided.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 November 2016 Resolved
Provide current certificate of documentation on board. Currently vessel as an expired COD and email eveidence of submission for a new one.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 7 December 2016
Resolution: Current COD shown in MISLE
Fire Fighting › Fire Pumps › Gears
Issued 8 November 2016 Resolved
Replace clutch and show proper operation of starboard side inboard fire pump.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 23 November 2016
Resolution: Operation demonstrated to USCG inspectors.
Fire Fighting › Fire Main › Condition
Issued 8 November 2016 Resolved
Repair pinhole in bilge/fire manifold. Make permanent repairs to starboard bilge/fire manifold. Crop to good metal and renew.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 22 November 2016
Resolution: Permanent repairs made and demonstrated to attending USCG inspectors.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 November 2016 Resolved
Show proper operation of bilge high level alarms.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 8 November 2016
Resolution: Corrected on the spot.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 8 November 2016 Resolved
Demonstrate fire and man overboard drills to attending USCG inspector.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 7 December 2016
Resolution: Drills successfully demonstrated to attending USGC marine inspectors.
Engineering › Lubricating Oil Service System › Gauge
Issued 8 August 2016 Resolved
Pilothouse gauges for RPM, L/O Pressure and J/W temp not functioning. Until functioning, maintain a manned engine space.
Action required: 705 - Other - as specified
Resolved 8 November 2016
Resolution: During annual exam gauges were observed operating as required.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 8 August 2016 Resolved
Replace flame screens on fuel vents with 30 x 30 mesh.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 22 November 2016
Resolution: Flame screen replaced.

Casualty record · 1

25 March 2003Routine · role: Cargo Recipient · activity 1813046
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ISLA GRANDE (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.