Records from 1999 to 2000. Most recent: operational control imposed, 25 January 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 25 January 2000
Resolved
PORT LIFE RING BUOY ON QUICK RELEASE SYSTEM REQUIRES REFLECTIVE TAPE REPAIR. S EE SOLAS 74/78 III /19.2.
Condition: Unknown
Due 31 January 2000
Resolved 15 February 2000
Navigation › Piloting/Steering › Marine Charts
Issued 25 January 2000
Resolved
STEERING MANEUVING CHART MISSING/REQUIRED. SEE 33 CFR 164.5.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 2 May 2013
Fire Fighting
Issued 25 January 2000
Resolved
FIRE DOORS IN THE ENGINE ROOM AND THE GALLEY DO NOT CLOSE PROPERLY, SELF/ CLOSING DEVICES DO NOT NOT COMPLETELY SEAL DOORS. SEE SOLAS 74/78 II- 2/34.1.
Condition: Unknown
Due 31 January 2000
Resolved 15 February 2000
Lifesaving
Issued 25 January 2000
Resolved
PAINT AND THINNER CANS CAN NOT PRPERLY SEAL. SEE SOLAS I/11(a).
Condition: Unknown
Due 25 January 2000
Resolved 15 February 2000
Fire Fighting
Issued 25 January 2000
Resolved
PROPER FIRE DRILL REQUIRED. SEE SOLAS 74/78 III/18.3
Condition: Unknown
Due 31 January 2000
Resolved 15 February 2000
Documentation
Issued 25 January 2000
Resolved
INTERNATIONAL/INLAND RULES OF THE ROAD MISSING. SEE 33 CFR 164.33.
Condition: Unknown
Due 31 January 2000
Resolved 15 February 2000
Lifesaving
Issued 25 January 2000
Resolved
GMDSS OPERATOR COULD NOT SWITCH RADIO TO DC POWER OPERATION. SEE SOLAS 74/78 II/5-1/REG. 43/2.3.2.3
Condition: Unknown
Due 31 January 2000
Resolved 15 February 2000
Lifesaving
Issued 25 January 2000
Resolved
QUICK RELEASE BOUY SYSTEM DOES NOT OPERATE PROPERLY. SEE SOLAS 74/78 III/7.1.
Condition: Unknown
Due 31 January 2000
Resolved 15 February 2000
Lifesaving
Issued 10 July 1999
Resolved
PROPERLY INSTALL QUICK RELEASE BRIDGE WING LIFE BOUYS (WITH LIGHT/SMOKE ATTACHMENTS). REQUIRED SMOKE AND LIGHT FOR LIFE BUOYS ARE NOT ATTACHED. THEQUICK RELEASE ARRANGEMENTS DO NOT ALLOW THE LIFE BUOYS TO BE RELEASED IMMEDIATELY.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Navigation
Issued 10 July 1999
Resolved
PROVE LOSS OF PHASE ALARM (ON BRIDGE) FOR STEERING IS OPERATIONAL. LOSS OF PHASE ALARM ON BRIDGE DOES NOT SOUND OR INDICATE FAILURE WHEN ELECTROHYDRAULIC STEERING MOTOR LOSES PHASE.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Lifesaving
Issued 10 July 1999
Resolved
MANUAL CONTROL WIRE FOR RELEASE GEAR IN PORT LIFE BOAT NEEDS TO BE REPAIRED. AS CURRENTLY INSTALLED, THE LIFEBOAT IS UNABLE TO BE LOWERED TO THE WATER USING THE MANUAL CONTROL WIRE.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Lifesaving
Issued 10 July 1999
Resolved
PORT AND STARBOARD LIFEBOAT RELEASING GEAR NEEDS TO BE PROPERLY INSTALLED, AS DESIGNED AND APPROVED. RELEASING GEAR FOR PORT AND STARBOARD LIFEBOATS DO NOT RELEASE.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Lifesaving
Issued 10 July 1999
Resolved
PROVIDE WEAK LINK FOR LIFE RAFTS.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Lifesaving
Issued 10 July 1999
Resolved
ABANDON SHIP DRILL & FIRE DRILL UNSAT. THE LIFEBOAT WAS UNABLE TO BE RELEASED. POWER AND VENTILATION DURING FIRE DRILL WAS NOT SECURED AND SCBA WAS IMPROPERLY WORN. FIRE PARTY CONFUSED AS TO ROLE OF PERSON IN FIRE SUIT.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Engineering › Thrusters › Hose
Issued 10 July 1999
Resolved
REPAIR OIL LEAK IN BOW THRUSTER COMPARTMENT
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 2 May 2013
Lifesaving
Issued 10 July 1999
Resolved
SHIP'S OFFICERS & CREW MUST DEMONSTRATE ADEQUATE ABANDON SHIP DRILL, FIRE DRILL, STEERING DRILL, AND ADEQUATE OVERALL KNOWLEDGE OF SHIP'S SYSTEMS. UNFAMILIAR WITH LIFEBOAT LOWERING OPERATION, LOCATION OF ELECTRICAL SWITCHBOARDS, EQUIPMENT USE/WEAR, & EMERGENCY STEERING SYSTEM OPERATION.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Fire Fighting
Issued 10 July 1999
Resolved
REMOVE HOLD BACK DEVICES FROM FIRE DOORS.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 10 July 1999
Resolved
CONDUCT AND LOG TESTS REQUIRED BEFORE ENTERING OR GETTING UNDERWAY FROM PORT.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 2 May 2013
Lifesaving
Issued 10 July 1999
Resolved
NO WATCH ROTATION LIST MATCHES SHIP'S LOG ENTRIES. PROVE ADEQUATE WORK/RESTROTATION. NO INFORMATION POSTED OR PROVIDED TO INDICATE STCW 95 STANDARDS REGARDING WATCHKEEPING ARE BEING MAINTAINED.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Fire Fighting
Issued 10 July 1999
Resolved
PROVIDE INSTRUCTIONS, LABELS, AND SYSTEM LINE DIAGRAM FOR OPERATION OF CO2 SYSTEM, POSTED AT CONTROL STATION IN CO2 ROOM.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 July 1999
Resolved
PROVIDE NON-CONDUCTIVE MATS OR GRATING AT THE FRONT AND REAR OF ELECTRICAL SWITCHBOARDS IN ENGINE ROOM (MAIN CONTROL) AND EMERGENCY CONTROL ROOM.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 2 May 2013
Navigation
Issued 10 July 1999
Resolved
PROVIDE CORRECTED CHARTS FOR AREA.
Condition: Unknown
Due 24 July 1999
Resolved 24 July 1999