← All vessels
MARGARET D
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named MARGARET D
MARGARET D is a 1976 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1981, most recently in November 2018, along with 23 deficiencies and 1 casualty investigation in 2018.
Records from 1981 to 2018. Most recent: inspection, 14 November 2018.
- Built
- 1976
- Last inspected
- 14 November 2018
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2018
Identity
578864
WYL8274
49019
Flag
UNITED STATES
366664660, 367686120 (licence lapsed)
Maury page id
psix-49019
Inspections, by type
…with no type recorded12
Years with a record
32 calendar years (1981–2018)
The 59 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
157 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
47 - Convention (Subpart B), Net Ton
157 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
47 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDI3226MMSI 367686120 · cancelled · compulsorily equipped · granted 29 July 2015, cancelled 5 May 2025
WYL8274MMSI 366664660 · cancelled · compulsorily equipped · granted 24 January 2015, cancelled 17 July 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 59
14 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580517
10 October 2018
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6645980
21 November 2017
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6341298
12 June 2017
Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6169269
13 July 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5936946
22 June 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5915154
11 August 2014
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4951558
12 July 2012
COI Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4377444
6 February 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4239370
29 September 2010
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3858752
29 October 2008
Inclining Experiment · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3350950
29 September 2008
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3333056
15 November 2007
COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3099415
8 January 2007
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2852456
19 September 2006
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2781882
27 August 2004
Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2177440
22 June 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2106648
18 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2008409
22 November 2002
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1709517
13 November 2002
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1704711
18 December 2001
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1475405
25 September 2000
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1362082
1 December 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 813301
5 October 1999
COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1459549
17 February 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393203
16 December 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1429060
5 June 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1127655
12 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114331
11 December 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408012
24 November 1997
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1388411
31 March 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 153408
17 October 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461743
23 August 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1088055
30 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 159242
17 October 1995
Hull Examination · COI Inspection · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1385558
3 November 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416039
16 November 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1159026
2 November 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1149119
4 February 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431280
11 February 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1263893
7 January 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1263892
6 August 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 939360
16 January 1991
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 925716
15 January 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1214209
15 January 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1214415
12 January 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 888466
6 January 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 892123
25 January 1988
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1326870
29 April 1987
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1024705
8 January 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013366
23 March 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1303934
9 January 1986
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1302887
27 August 1985
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 988504
11 January 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1284045
28 March 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 972828
11 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975572
11 January 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 963574
12 January 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973834
14 May 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971783
Deficiency record · 23
Fire Fighting › Fire Hoses › Condition
Issued 22 September 2004
Resolved
Found 50 foot X 1.5 inch fire hose leaking during pressure test. Renew with hose meeting requirements of 46 CFR 181.320.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 September 2004
Resolved
Provide 01 Adult Type I PFD in serviceable condition approved under 46 CFR 160.055 in accordance with 46 CFR 180.71 and mark in accordance with 46 CFR 185.604
Engineering › Steering Gear System › Linkage
Issued 27 August 2004
Resolved
Found starboard rudder post linkage running clearance excessive. Repair IAW manfactures recommended practices and demonstrate proper operation of steering system.
Construction/Loadline › Hull › Weld
Issued 27 August 2004
Resolved
Stanchion outboard and aft of of port propulsion engine found fractured at base. Crop and renew as original.
Accommodation/Occupational Safety › Ventilation
Issued 18 December 2001
Resolved
PROPERLY REPAIR GENERATOR ROOM BLOWER MOTOR
Construction/Loadline › Structures › Door
Issued 18 December 2001
Resolved
PROPERLY ADJUST ALL WATERTIGHT DOORS BELOW THE MAIN DECK
Engineering › Fuel Oil Service System › Valve
Issued 18 December 2001
Resolved
PRIOR TO SAILING REPAIR F/O DAY TANK EMERGENCY CUT-OFF REACH ROD.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 18 December 2001
Resolved
PROPERLY WELD CRACKS IN PORT O/B MDE FOUNDATION.
Accommodation/Occupational Safety
Issued 5 October 1999
Resolved
Properly label range disconnect breaker.
Construction/Loadline
Issued 5 October 1999
Resolved
Properly repair four broken welds in lazarette.
Electrical
Issued 5 October 1999
Resolved
Properly install pulley guards for both generators.
Lifesaving
Issued 5 October 1999
Resolved
Service EPIRB hydrostatic releasing mechanism.
Accommodation/Occupational Safety
Issued 5 October 1999
Resolved
Relabel engine room and lazarette/generator room door "emergency exit" labels.
Documentation
Issued 17 October 1995
Resolved
VESSEL SHALL BE READMEASURED DUE TO CHANGES OF VESSEL DIMENSIONS AND A UPDATED CERTIFICATE OF DOCUMENTATION SHALL BE PROVIDED TO REFLECT CHANGES IN TONNAGE AND DIMENSIONS OF THE VESSEL. VERIFICATION SHALL BE SENT DIRECTLY TO MSO MOBILE FOR ACTION._x001C_
Documentation
Issued 25 January 1988
Resolved
HAVE COASTWISE TRADE ENDORSEMENT ADDED TO CERTICATE OF DOCUMENTATION.
Construction/Loadline
Issued 9 January 1986
Resolved
REWELD CRACKED WELDS IN GUSSETS AND STIFFINERS PORT AND STARBOARD TRANSOM CORNERS.
Construction/Loadline
Issued 9 January 1986
Resolved
CLEAN GASKET ON WATERTIGHT DOOR AT AFT ENTRANCE TO BRIDGE.
Construction/Loadline
Issued 9 January 1986
Resolved
REPAIR LOWER AFT DOG ON STARBOARD BRIDGE WATERTIGHT DOOR.
Unknown
Issued 9 January 1986
Resolved
REPLACE BROKEN HANDLES ON VALVES AT ENGINE ROOM ENTRANCE MANIFOLD.
Construction/Loadline
Issued 9 January 1986
Resolved
REPAIR HANDRAIL ON PORT SIDE.
Construction/Loadline
Issued 11 January 1985
Resolved
REPAIR THE STERN TRANSOM OF THE VESSEL. ALL UPSET BRACKETS IN THE P/S CORNERS IN THE STERN COMP SHALL BE REPLACED. ALL ASSOC LONG IN THAT COMP WICH ARE DAMAGED SHALL BE REPLACED. ALL EXTERIOR HULL DAMAGE SHALL BE REPAIRED.
Electrical
Issued 11 January 1984
Resolved
PROVIDE AND TEST REMOTE ELECTRICAL SHUTDOWN SWITCHES FOR MACHINERY SPACE MECHANICAL VENTILATION AND AIR CONDITIONING UNIT.
Unknown
Issued 11 January 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL CYNTHIA N, DN578864.
Casualty record · 1
10 October 2018Routine · role: Involved in a Marine Casualty · activity 6645980
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.