MAURY USCG vessel records Sign in
← All vessels

AQUA DOG III

AQUA DOG III is a 1963 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 1999, most recently in March 2014, along with 45 deficiencies and 2 operational controls.

Records from 1999 to 2014. Most recent: inspection, 5 March 2014.

Built
1963
Last inspected
5 March 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

490239
Flag
UNITED STATES
—
Maury page id
psix-490239

Inspections, by type

Years with a record 14 calendar years (1999–2014)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

5 March 2014 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4810697
4 January 2011 Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3920356
10 March 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3697431
26 March 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3436111
21 February 2008 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3153205
18 January 2008 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3135490
14 February 2007 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2875902
9 January 2006 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2571691
26 May 2005 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2369861
14 September 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2195804
31 March 2004 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2040038
27 January 2003 Re-Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1736611
31 January 2002 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1483129
9 January 2002 COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1477072
9 February 2001 Re-Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1432444
13 April 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1049292
5 April 2000 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1415338
10 February 1999 Initial Certification · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1372504

Deficiency record · 45

Construction/Loadline › Hull › Bottom Plating
Issued 30 March 2011 Resolved
Crop and renew bottom plate where holed at stbd bow. 46 CFR 177.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2011
Resolution: Verified deteriorated section has been cropped and renewed.
Electrical › Electric Supply System (service) › Cable
Issued 7 January 2011 Resolved
Mount battery switch at operating station. (Switch is hanging by cable) 46 CFR 183.200(b)
Due 17 January 2011
Resolved 30 March 2011
Resolution: Verified corrected.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 January 2011 Resolved
Repair stern nav light. (nav light mount is broken and held on by electrical tape) 46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2011
Resolution: Verified corrected.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 January 2011 Resolved
Post emergency broadcast placard near radio. 46 CFR 184.506
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2011
Resolution: Verified now in place.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 January 2011 Resolved
Renew lens for stbd nav light. (lens has clouded over) 46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2011
Resolution: Verified new lens in place.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 7 January 2011 Resolved
Provide two portable lights. 46 CFR 183.430
Due 17 January 2011
Resolved 7 January 2011
Resolution: Item was corrected on the spot.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 7 January 2011 Resolved
Renew mounting bracket for fire extinguisher at operating station. 46 CFR 181.520
Due 17 January 2011
Resolved 30 March 2011
Resolution: Completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 January 2011 Resolved
Repair broken port exhaust pipe. 46 CFR 182.430
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2011
Resolution: New exhaust piping in place for both port and stbd engines.
Construction/Loadline › Hull › Bottom Plating
Issued 7 January 2011 Resolved
Crop and renew bottom plate where holed at bow. Where marked by USCG inspector. 46 CFR 177.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2011
Resolution: Completed for port bow.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 4 January 2011 Resolved
Provide two portable lights. 46 CFR 183.430
Due 17 January 2011
Resolved 17 January 2011
Resolution: Corrected on the spot.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 10 March 2010 Resolved
Ensure all batteries are secured and placed in an enclosure resistant to the battery electrolyte.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 11 March 2010
Resolution: Item corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 March 2010 Resolved
Prior to carrying passengers ensure fixed firefighting system is serviced.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2010
Resolution: Item corrected.
Engineering › Bilge Water Management System › Not Operational
Issued 10 March 2010 Resolved
Prior to carrying passengers ensure forward bilge alarm is operational.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2010
Resolution: Item corrected.
Engineering › Lubricating Oil Service System › Hose
Issued 10 March 2010 Resolved
Replace leaking hose between oil filter and engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 7 January 2011
Resolution: Did not discover a leaking hose during 7JAN11 inspection.
Engineering › Fuel Oil Service System › Hose
Issued 10 March 2010 Resolved
Replace worn fuel hose.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 7 January 2011
Resolution: New fuel hoses are installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 March 2010 Resolved
Re-clamp section on flexible hose on heat exchanger.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 7 January 2011
Resolution: All visible clamps appeared to properly secured.
Engineering › Fuel Oil Service System › Hose
Issued 10 March 2010 Resolved
Place chafing gear where indicated on the engine piping and hoses.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 7 January 2011
Resolution: Corrected.
Construction/Loadline › Structures › Superstructure
Issued 10 March 2010 Resolved
Repair cracked centerline portion of pipe that supports the overhead canopy. Vessel canopy is supported by two side stringers, at least 4 stanchions on each side in addition to the centerline pipe that is fractured near the center of the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 7 January 2011
Resolution: Found pipe supporting canopy to be sound during 7JAN11 inspection.
Lifesaving › Hand Flares › Not on Board
Issued 26 March 2009 Resolved
Vessel required to have three red hand flares and three orange smokes in an properly marked watertight container or have the COI changed to reflect vessel is only permited on short runs 30 minutes or less.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Item found and corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 March 2009 Resolved
Remove loose and exposed wires from engine room and steering compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Item corrected
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 March 2009 Resolved
Ensure logs for training/man overboard drills are placed on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Logs and training were on board vessel.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 March 2009 Resolved
Repair aft running light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Item repaired.
Engineering › Lubricating Oil Service System › Hose
Issued 26 March 2009 Resolved
Replace worn hydraulic hose below engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Hydraulic hose replaced.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 March 2009 Resolved
Stencil number of child life preservers on containers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Number re-stenciled.
Engineering › Fuel Oil Service System › Valve
Issued 26 March 2009 Resolved
Place handle on lid to fuel shutoff valve.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Item found and corrected.
Engineering › Fuel Oil Service System › Hose
Issued 26 March 2009 Resolved
Protect fuel line on diesel engine from chafing against moving parts.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Item found and corrected.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 26 March 2009 Resolved
Mount battery switch on pilot house control panel.
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Battery switch mounted.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 March 2009 Resolved
Secure battery housing in place.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Batteries secured and bolted down- corrected.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 26 March 2009 Resolved
Prove ability to steer using the front wheels alone.
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 9 April 2009
Resolution: Vessel operator demonstrated ability to disconnect the rudder from the front wheel steering gear.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 January 2008 Resolved
Prove proper operation of aft bilge high water alarm.
Due 18 February 2008
Resolved 21 February 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 18 January 2008 Resolved
Prove proper operation of turn signals, brake lights and caution lights.
Due 18 February 2008
Resolved 21 February 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 January 2008 Resolved
Replace expired items in 1st aid kit.
Due 18 February 2008
Resolved 14 February 2008
Engineering › Fuel Oil Service System › Hose
Issued 18 January 2008 Resolved
Replace cracked fuel line with approved type.
Due 18 February 2008
Resolved 21 February 2008
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 18 January 2008 Resolved
Complete preoperational safety checklist for amphibious vehicle to be completed each time prior to getting underway.
Due 18 February 2008
Resolved 21 February 2008
Engineering › Bilge Water Management System › Piping
Issued 14 February 2007 Resolved
Replace wasted hydraulic bilge pump lines with approved type.
Due 14 March 2007
Resolved 18 January 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 February 2007 Resolved
Service fixed firefighting system.
Due 14 March 2007
Resolved 18 January 2008
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 14 February 2007 Resolved
Develop and implement pre-operational safety checklist to be completed each voyage prior to getting underway.
Due 14 March 2007
Resolved 18 January 2008
Engineering › Bilge Water Management System › Pump
Issued 26 May 2005 Resolved
Repair Portside electric bilge pump.
Condition: Improper/Lack of Maintenance
Due 10 June 2005
Resolved 9 January 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 May 2005 Resolved
Repair starboard navigation running light.
Condition: Improper/Lack of Maintenance
Due 10 June 2005
Resolved 9 January 2006
Lifesaving › Lifejacket/PFD (Type I)
Issued 9 January 2002 Resolved
Lifejackets stenciled with "Panama" - Remove and stencil with vessel name. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 9 February 2002
Resolved 31 January 2002
Electrical › Electric Supply System (service)
Issued 9 January 2002 Resolved
Cover exposed batteries and terminals. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 9 February 2002
Resolved 31 January 2002
Electrical › Electric Supply System (service)
Issued 9 January 2002 Resolved
Demonstrate 3 consecutive engine starts - Possible bad starting batteries. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 9 February 2002
Resolved 31 January 2002
Personnel › Certificates/Documents/Licenses
Issued 9 January 2002 Resolved
Provide original Captain's license for inspection. LEGACY COMPONENT DESC: License, Master
Action required: 705 - Other - as specified
Due 9 February 2002
Resolved 31 January 2002
Documentation › Manuals/Policy Documentation
Issued 9 January 2002 Resolved
Provide proof of enrollment in drug & alcohol testing program for both Capt and Deckhand.
Action required: 705 - Other - as specified
Due 9 February 2002
Resolved 31 January 2002
Engineering › Lubricating Oil Service System
Issued 9 January 2002 Resolved
Reconnect oil drain hoses on propulsion engine.
Action required: 705 - Other - as specified
Due 9 February 2002
Resolved 31 January 2002

Ownership record