Records from 2016 to 2026. Most recent: inspection, 29 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)40.9 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 31 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portORCAS ISLAND, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
29 April 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8320421
19 March 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8096585
28 February 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7872436
14 February 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868512
22 March 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7652715
5 April 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7426843
17 March 2022
Drydock Exam · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7413765
20 April 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7181693
21 May 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6957595
17 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6923577
29 April 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6670234
30 March 2018
COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6378846
9 March 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6364284
19 April 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6128509
6 December 2016
Simplified Stability Test
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6094352
4 May 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5869743
23 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5840102
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 March 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. A hull penetration in the starboard corner of the sewage holding tank space was identified and affecting the watertight integrity of the space. O/o is to secure the penetration and ensure the watertight integrity of the space.
46 CFR 179.320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 2 May 2025
Resolution: Vsl utilized pvc hole penetration plug appliance to rectify watertight integrity of space. Acceptable repair device due to location high above the waterline through hull. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 March 2025
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy.
46 CFR 180.70(d)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 2 May 2025
Resolution: Vsl installed corrosion resitant clip to affix waterlight properly to ring buoy. All sat.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 19 March 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Marking for remote fuel shutoff valves are hidden under matting. O/o is to ensure the above requirements are met and plainly visible.
46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 19 March 2025
Resolution: O/o provided evidence that markings indicating location of shut off valves are visible and uncovered.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 19 March 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. O/o did not have emergency instructions for the aforementioned conditions. O/o is to draft instructions tailored to the arrangement and equipment of the vessel, post them, and ensure their and their crew’s familiarity. Refer to 46 CFR 185.512 for further guidance and recommendations for meeting this requirement. Refer to 46 CFR 185.520 for further guidance on abandon ship and MOB drills and training. Refer to 46 CFR 185.524 for firefighting drills and training.
46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 5 May 2025
Resolution: 05May25: Received photo documentation of emergency instructions. Vessel found to be in compliance.
02APR25: Extended due to vessel hauling out and not operating.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 March 2025
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. O/o is to ensure the availability of three hand red flares on board the vessel.
46 CFR 180.68(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 19 March 2025
Resolution: O/o brought into service the required three red hand flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2022
Resolved
The number and identification of the items stowed inside and their sizes, must be marked in clearly legible numbers on each container for life jackets.
46 CFR 185.604(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 22 April 2022
Resolution: Updated stowage placard
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 5 April 2022
Resolved
Add deckhand to consortium.
46 CFR 16.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 22 April 2022
Resolution: Deckhand added to consortium
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 April 2022
Resolved
Provide crew training log book.
46 CFR 185.420 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 26 April 2022
Resolution: Provided training log.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2022
Resolved
Provide satisfacotry evidence of required servicing of fire extinguishers.
46 CFR 176.810(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 22 April 2022
Resolution: Fire extinguishers serviced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021
Resolved
There was only 01 chemical testing swab onboard, and it was expired. 02 testing swabs current swabs need to be onboard.46CFR185.212
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 30 January 2022
Resolution: Added 02 testing swabs
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 April 2021
Resolved
Retroflective tape on 05 life jackets is not in serviceable condition and must be replaced. 46CFR176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 29 July 2021
Resolution: retro tape was replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 April 2021
Resolved
Stability letter needs to be posted at the operating station of the vessel. 46CFR176.306
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2021
Resolved 30 January 2022
Resolution: Posted stability letter as required
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 April 2021
Resolved
Some of the medicines in the first aid kit are expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 29 July 2021
Resolution: medicines were updated
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 April 2021
Resolved
Up to date Coast Guard light list is required to be onboard. 46CFR184.420(a)(3)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 30 January 2022
Resolution: new light list onboard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2019
Resolved
Alcohol test strips are not on board and available in the event of a SMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 13 May 2019
Resolution: Obtained alcohol test strips - new test strips expire 2020-04-30
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 April 2019
Resolved
Lifefloats are not stowed in a manner that prevents shifting.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 13 May 2019
Resolution: Lifefloats have been stowed to prevent shifting.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 April 2019
Resolved
STBD side bow handrail support at flange has become detached from deck. Reattach at flange. 46 CFR 177.900(a)(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 13 May 2019
Resolution: Handrail has been permanantly attached.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2019
Resolved
Mast light has been unbolted from cabin roof deck. Reinstall mast light. 46CFR183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 13 May 2019
Resolution: Mast light has been re-installed and is operational.
Lifesaving › Lifefloat › Serviceable
Issued 19 April 2017
Resolved
Repair Holes in life float
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 20 May 2017
Resolution: Owner filled holes and repainted lifefloat.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 19 April 2017
Resolved
Repair small leak in STBD fuel tank vent hose and insure upward gradient.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 20 May 2017
Resolution: Vent was repaired.
Lifesaving › Lifefloat › Float-free Link
Issued 19 April 2017
Resolved
Life float missing float free link data tag. Replace with new tag/link.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 20 May 2017
Resolution: link replaced.