Records from 1984 to 2011. Most recent: inspection, 5 July 2011.
Construction/Loadline › Structures › Deck Plating
Issued 14 October 2008
Resolved
Submit repair proposal for rotted wood IWO lazarette overhead underneath aluminum decking. All repairs to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 28 November 2008
Resolved 14 May 2009
Communications › Alarms/Indicators › Fire Alarm
Issued 10 June 2008
Resolved
Prove proper operation of smoke detector in fuel tank compartment and both restrooms.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 10 June 2008
Resolved
Properly secure microwave in galley.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 10 June 2008
Resolved
Remove flammables stored non approved deck locker on 2nd deck.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 June 2008
Resolved
Provide valid Certificate of Documentation.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Personnel › Training › First Aid/CPR
Issued 10 June 2008
Resolved
Provide proof of CPR training for 50% of crew.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 June 2008
Resolved
Install anchor light
Action required: 705 - Other - as specified
Resolved 13 June 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 10 June 2008
Resolved
Label engine room ventilation closures.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Lifesaving › Lifebuoys › Serviceable
Issued 10 June 2008
Resolved
Repair or replace faded ring lifebuoy.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Personnel › Training › Familiarization Training
Issued 10 June 2008
Resolved
Provide crew training log for review.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 June 2008
Resolved
Remove gear in life jacket locker on stern stbd side.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 June 2008
Resolved
Provide donning placard at locker for type of life jacket stored.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 June 2008
Resolved
Provide copy of contract and proof of enrollment in consortium. Also provide list of employees covered.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 10 June 2008
Resolved
Provide valid alcohol testing devices.
Action required: 705 - Other - as specified
Resolved 14 October 2008
Documentation › Certificates/Documents › FCC SSL
Issued 10 June 2008
Resolved
Provide valid FCC station license. Current license expired 13 Apr 08.
Action required: 705 - Other - as specified
Resolved 14 October 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 June 2008
Resolved
Stow all excess gear and secure for sea.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Operations/Management › Drills/Instruction › Fire
Issued 10 June 2008
Resolved
Conduct fire and man overboard drills to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 10 June 2008
Resolved
Conduct propulsion and steering tests to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 10 June 2008
Resolved
Prove proper operation of Stbd Engine room ventilation closure.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 10 June 2008
Resolved
Make proper repairs to leak on Port black water holding tank. Vsl owner is required to pump down tank and secure from using until satisfactory repairs are completed.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 14 October 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 June 2008
Resolved
Provide machinery guard over rotating belt on back side of generator.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 14 October 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 May 2008
Resolved
Remove items from fwd peak for internal structural exam.
Action required: 705 - Other - as specified
Resolved 2 June 2008
Construction/Loadline › Hull › Keel
Issued 22 May 2008
Resolved
Grind back spot on keel as marked. (approx. 6' from stern)
Action required: 705 - Other - as specified
Resolved 2 June 2008
Construction/Loadline › Hull › Bottom Plating
Issued 22 May 2008
Resolved
Replace glass bottom fasteners. A total of seven were found.
Action required: 705 - Other - as specified
Resolved 2 June 2008
Stability › Watertight Integrity › General
Issued 22 May 2008
Resolved
Make viewing room glass bottom fwd bulkhead IWO bilge piping watertight.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 May 2008
Resolved
Remove or properly terminate dead end wires in fwd peak and viewing room.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 22 May 2008
Resolved
Service E/R fixed system and portable extinguishers and provide copy of servicing certificate to Coast Guard. Last servicing expired Feb 2008.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 22 May 2008
Resolved
Prove proper operation of e-lighting in viewing room.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 22 May 2008
Resolved
Properly secure light fixture IVO E/R fwd bulkhead.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 May 2008
Resolved
Provide cover for electrical box under bridge console.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 May 2008
Resolved
Properly secure ladder in lazerette.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Construction/Loadline › Structures › Superstructure
Issued 22 May 2008
Resolved
Grind back to good wood all rotting areas to lazerette overhead for Coast Guard inspection.
Action required: 705 - Other - as specified
Due 28 November 2008
Resolved 14 October 2008
Resolution: Visited the vsl on 14 Oct and decision was that due to the extend of the rotted wood issued a new requirement to submit repair proposal.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 May 2008
Resolved
Remove all combustibles from engine room.
Action required: 705 - Other - as specified
Resolved 13 June 2008
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 22 May 2008
Resolved
Reattach bonding wire under stbd fuel tank.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 May 2008
Resolved
Replace cover panel on hot water heater.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Engineering › Bilge Water Management System › Pump
Issued 22 May 2008
Resolved
Make permanent repairs to water leak on bilge pump.
Action required: 705 - Other - as specified
Resolved 10 June 2008
Construction/Loadline › Hull › Keel
Issued 22 May 2008
Resolved
Submit repair proposal from area of keel approx. 6 ft from stern.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Electrical › Electric Generation Source (service) › Generator
Issued 17 December 2007
Resolved
Make proper repairs to ship service generator. Prove proper operation of generator. No passengers are allowed on board vessel until repairs are completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2007
Resolved 6 March 2008
Resolution: onboard
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 4 December 2007
No resolution recorded
Provide means to determine when sewage tank is 3/4 full as per 33 CFR 159.85.
Action required: 705 - Other - as specified
Due 28 November 2008 — due date passed with no resolution recorded
Construction/Loadline › Structures › Superstructure
Issued 4 December 2007
No resolution recorded
Provide plans for second deck to include structural details by next quarterly exam.
Action required: 705 - Other - as specified
Due 28 November 2008 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 15 March 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 8 June 2007
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 15 March 2007
Resolved
Provide proof of EAP training for all listed crew members.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 8 June 2007
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 15 March 2007
Resolved
Properly mark stern of vessel with name and hailing port.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 8 June 2007
Fire Fighting › Means of Escape › Blocked
Issued 15 March 2007
Resolved
Remove egress obstruction in lower viewing port. Clear egress in main deck to bow. Remove sofa from main deck. Maintain egress IAW 46 CFR 177.500(f).
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 13 July 2007
Construction/Loadline › Structures › Door
Issued 15 March 2007
Resolved
Replace broken glass to door leading to bow. Properly repair aft sliding door.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 8 June 2007
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 15 March 2007
Resolved
Replace broken glass to pilot house looking aft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 8 June 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 March 2007
Resolved
Replace missing railing on starboard bow aft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 8 June 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 March 2007
Resolved
Properly mount water light for life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 8 June 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 March 2007
Resolved
Renew deck rail courses on upper deck IAW 46 CFR 177.920.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 8 June 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 March 2007
Resolved
Provide evidence of signed receipt letter from Seattle REC and old license was returned to REC Seattle as directed in CG letter 16721 dated 11 July 2006.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2007
Resolved 8 June 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 25 January 2007
Resolved
On the Passenger Vessel Safety Radio certificate provide the signature of the inspector, expiration date and contact phone number to the inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 8 June 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 January 2007
Resolved
Provie proper operation of man overboard light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2007
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 25 January 2007
Resolved
Renew hand rail netting on stern main deck. Repair cracked railing at starboard side boarding gate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 15 March 2007
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 25 January 2007
Resolved
Provide proof of A-Admirals contract with drug testing company.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 15 March 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 January 2007
Resolved
Relocate PFD'S to main deck from top deck. Provide 63 adult and 7 child size.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 15 March 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 January 2007
Resolved
Repair/ prove operation of starboard running light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 29 June 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 January 2007
Resolved
Provide proof of servicing and proper operation of fixed fighting system by a qualified servicing facility
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 15 March 2007
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 25 January 2007
Resolved
Remove flammable liquids from the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 15 March 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 January 2007
Resolved
Properly stow gear in fuel tank compartment. Not on exhaust piping, not hanging on electrical wires.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 8 June 2007
Personnel › Training › Familiarization Training
Issued 25 January 2007
Resolved
Provide documentation of initial training of [name withheld], covering everything in emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 15 March 2007
Operations/Management › Passenger Operations › Safety Orientation
Issued 25 January 2007
Resolved
Provide required information for passenger count per 46 CFR 185.504
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 8 June 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 25 January 2007
Resolved
Repair excessive oil leaks on port propulsion engine or prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 13 July 2007
Fire Fighting › Fire Bucket › Availability
Issued 25 January 2007
Resolved
Provide 2 more 2.5 gallon fire buckets onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 15 March 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 January 2007
Resolved
Present the vessel for quarterly inspection no more than 90 days after the COI is issued.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2007
Resolved 4 December 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 25 January 2007
Resolved
No passengers are allowed on upper deck until CG approval of installtion of upper deck has been made.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2007
Resolved 8 June 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 January 2007
Resolved
Properly log back ground checks IAW 49 CFR part 40 for all employees newly hired subject to DOT drug testing in the previous 2 years.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 29 June 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 January 2007
Resolved
Replace expired items in first aid kit (iodine and eye wash solution).
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2007
Resolved 29 June 2007
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 25 January 2007
Resolved
Provide spec sheets for resin used for hull repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 29 June 2007
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 January 2007
Resolved
Repair leaking valve on starboard fuel oil tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 13 July 2007
Construction/Loadline › Structures › Superstructure
Issued 25 January 2007
Resolved
Properly mount canopy frame on 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 29 June 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 25 January 2007
Resolved
Provide training log as required by 46 CFR 185.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 29 June 2007
Navigation › Piloting/Steering › Marine Charts
Issued 25 January 2007
Resolved
Provide current and corrected charts as required by 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 4 December 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 January 2007
Resolved
Repair and prove proper operation of navigation lights as required by 46 CFR 183.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 29 June 2007
Communications › Audible Communications › Bell
Issued 25 January 2007
Resolved
Provide ships bell as required by 33 CFR part 86.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 13 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 25 January 2007
Resolved
Provide B-II fire extinguisher for galley.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 13 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 January 2007
Resolved
Provide proper fire extinguisher brackets where required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 13 July 2007
Fire Fighting › Ventilation Systems › Operating Controls
Issued 25 January 2007
Resolved
Prove proper operation of engine room vent shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 29 June 2007
Personnel › Training › Compass, Magnetic and Gyro
Issued 25 January 2007
Resolved
Demonstrate proper use of deviation table.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 4 December 2007
Personnel › Training › Seamanship
Issued 25 January 2007
Resolved
Demonstrate proper use of tide and current tables.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 4 December 2007
Personnel › Training › Familiarization Training
Issued 25 January 2007
Resolved
Demonstrate proper operation of engine room fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 29 June 2007
Engineering › Fuel Oil Service System › Tank
Issued 25 January 2007
Resolved
Run fuel down below inspection cover on aft starboard fuel oil tank and make repairs to inspection port gasket.
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 13 June 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 January 2007
Resolved
Provide correct light list for area operating.
Due 31 July 2007
Resolved 4 December 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 25 January 2007
Resolved
Provide receipts for sewage pump out and maintain log to document when sewage tank has been pumped out.
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 14 October 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 January 2007
Resolved
Demonstrate adequate recovery of man overboard.
Due 13 October 2007
Resolved 4 December 2007
Personnel › Training › Navigation/Position Determination
Issued 25 January 2007
Resolved
[name withheld] shall complete refresher course for piloting and chart correction. Course shall be from a Coast Guard recognized source. Vessel is restricted to operations between Dania Beach Blvd. Bridge to Spanish River Bridge to include areas in between offshore no greater than (3) three miles. [name withheld] has (60) sixty days to complete refresher training.
Due 12 September 2007
Resolved 4 December 2007
Construction/Loadline › Structures › Superstructure
Issued 26 October 2006
Resolved
Passengers are restricted from the upper deck in accordance with Miami letter 16711/06890. Total passengers allowed on board is reduced to not more than 76 passengers.
Due 15 March 2007
Resolved 15 March 2007
Fire Fighting › Fire Pumps › Capacity
Issued 20 July 2006
Resolved
The vessel is limited to no more than 49 passengers until the fire pump and hose can show an adeqate stream of water in all spaces. The vessel shall carry three buckets with lanyards.
Action required: 705 - Other - as specified
Due 20 August 2006
Resolved 6 March 2008
Resolution: made a special note
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 July 2006
Resolved
Remove all stores from the top of the fuel tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2006
Resolved 20 July 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 July 2006
Resolved
Remove gear from stairs at viewing room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2006
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 13 July 2006
Resolved
Remove flammibles (paint, thinner) from aft locker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2006
Construction/Loadline › Structures › Door
Issued 13 July 2006
Resolved
Install aft door handle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2006
Personnel › Training › Familiarization Training
Issued 13 July 2006
Resolved
Prior to the inspector returning , the crew must perform 2 good drills u/w and log.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2006
Documentation › Certificates/Documents › FCC SSL
Issued 31 May 2006
Resolved
Provide current FCC Radio Safety Certificate.
Due 14 June 2006
Resolved 13 July 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 31 May 2006
Resolved
Remove extension cord to 2nd deck DJ power supply and hard wire.
Due 14 June 2006
Resolved 13 July 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 31 May 2006
Resolved
Provide permanent power supply to cooler 2nd deck.
Due 14 June 2006
Resolved 15 March 2007
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 31 May 2006
Resolved
Remove items and sanitize main deck bar cooler. Items covered in fungus.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 15 March 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 31 May 2006
Resolved
Provide proper handle for sewage three way valve on starboard engineroom.
Due 14 June 2006
Resolved 13 July 2006
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 31 May 2006
Resolved
Properly attach distribution system switchboard in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 15 March 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 May 2006
Resolved
Properly attach stairs to engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 13 July 2006
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 31 May 2006
Resolved
Remove from vessel excess stores in lower void, main deck head and pilot house.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 20 July 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 31 May 2006
Resolved
Properly wire freezer on main deck starboard and remove extension cord.
Due 14 June 2006
Resolved 20 July 2006
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 31 May 2006
Resolved
Properly mount freezer in main deck starboard.
Due 14 June 2006
Resolved 20 July 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 31 May 2006
Resolved
Renew retro tape and marking on life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 13 July 2006
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 31 May 2006
Resolved
Renew markings on life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 13 July 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2006
Resolved
Provide proper first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 13 July 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 May 2006
Resolved
Properly mount high water alarm in aft lazerette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 13 July 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 May 2006
Resolved
Provide high water alarm in space outside glass bottom and provide visual and audible indicators at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 13 July 2006
Stability › Watertight Integrity › General
Issued 31 May 2006
Resolved
Properly seal hole in port side hull aft lazerette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 13 July 2006
Personnel › Training › Familiarization Training
Issued 31 May 2006
Resolved
Provide familiarization training to new crew members to include underway drills. Document all training.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 20 July 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 31 May 2006
Resolved
Provide updated navigation pubs and charts.
Due 14 June 2006
Resolved 20 July 2006
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 31 May 2006
Resolved
Complete all work list items from recent hull exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 20 July 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 May 2006
Resolved
Present vessel and crew for safety drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 20 July 2006
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 31 May 2006
Resolved
Provide current CPR cards for 50% of crew.
Due 14 June 2006
Resolved 13 July 2006
Electrical › Electric Generation Source (service) › Power Requirement
Issued 31 May 2006
Resolved
Prove proper operation of both generators to include fixed system shut down.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 15 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2006
Resolved
FOREPEAK- Repair broken alarm wires and replace brown household wire with boat cable.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 31 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2006
Resolved
Bridge- Remove extension cords and multi-outlet tap; provide boat cable wiring to overhead lights; provide cover at 4 gang outlet in overhead.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 31 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2006
Resolved
Galley- provide a correct breaker listing; prove 30 amp breaker for stove is correct; remove dead end cables form behind helm station.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 13 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2006
Resolved
Upper Deck- repair broken 110 duplex box starboard side; remove extension cords; properly attach overhead lights to canopy (no wire ties)
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 31 May 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 April 2006
Resolved
Upper Deck- properly attach handrail stantions to deck (loose).
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 31 May 2006
Deck/Cargo › Cargo Stowage › General
Issued 19 April 2006
Resolved
Properly attach cooler on upper deck and provide weight. Weight should include cooler and contents.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 13 July 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2006
Resolved
Engine room- Porvide proper marine fixtures or remvoe fixtures in engine room.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 31 May 2006
Electrical › Electric Supply System (service) › Transformer
Issued 19 April 2006
Resolved
Engine room- properly install DC-AC converter or remove. ( no spring clips ).
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 13 July 2006
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 19 April 2006
Resolved
Engine room- remove oil from bilges of engine room.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 20 July 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 April 2006
Resolved
Bow, fore deck- properly attach handrail stantions starboard side at bow.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 13 July 2006
Construction/Loadline › Structures › Superstructure
Issued 19 April 2006
Resolved
Main salon- properly attach the three stations (top and bottom) in the salon.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 13 July 2006
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 19 April 2006
Resolved
Lazerette- renew or repair bonding wires at steering gear.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 13 July 2006
Construction/Loadline › Structures › Superstructure
Issued 19 April 2006
Resolved
Lazerette- renew threaded rods port and starboard in overhead of lazerette. ( used to hold down the upper deck ).
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 15 March 2007
Electrical › Electric Generation Source (service) › Generator
Issued 8 March 2006
Resolved
Prove proper operation of both generator sets.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2006
Resolved 9 March 2006
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2005
Resolved
Secure and or remove loose and dead end wires located in enigine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2005
Navigation › Piloting/Steering › Marine Charts
Issued 21 April 2005
Resolved
Procure and have available large scale updated chart of operation area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2005
Resolved 9 March 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 April 2005
Resolved
Establish shore based confirmation for passenger count.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2005
Resolved 9 March 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 21 April 2005
Resolved
Repair or install new VHF-FM radio, provide handset for internal communications.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 31 May 2006
Navigation › Piloting/Steering › Binnacle
Issued 21 April 2005
Resolved
Properly install compass binnacle,verify proper operations of light, and update deviation table.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 15 March 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 21 April 2005
Resolved
Remove or properly hard wire all exterior Christmas type lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 15 March 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 21 April 2005
Resolved
Post signage to indicate” fire extinguisher inside" for fire station #2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 15 March 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 April 2005
Resolved
Renew generator raw water suction hose. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 April 2005
Resolved
Remove "Excess" bulk of oily water from bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2005
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 21 April 2005
Resolved
Remove excess storage of spare parts, paints, and other combustables from the vesseol.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2005
Resolved 9 March 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 April 2005
Resolved
Clean, inspect, and renew retro on the 58 identified adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2006
Engineering › Diesel Engine (propulsion-electric) › Silencer (exhaust)
Issued 21 April 2005
Resolved
Remove generator exhaust muffler from atop fire pump and properly mount. Properly mount fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 13 July 2006
Engineering › Bilge Water Management System › Pump
Issued 21 April 2005
Resolved
Install new bilge pump forward of port main engine or cap off thru-hull at hull side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 28 April 2005
Construction/Loadline › Hull › Side Shell
Issued 21 April 2005
Resolved
Cap off thru-hull located port side steering room. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2005
Electrical › Electric Supply System (service) › Cable
Issued 17 June 2004
Resolved
Make permenet repairs to damaged electrical components in way of the shore power connection.
Condition: Damaged By Earlier Event
Due 2 July 2004
Resolved 17 June 2004
Construction/Loadline › Structures › Superstructure
Issued 17 June 2004
Resolved
Make permenent repairs to the superstructure and pilot house windows.
Condition: Damaged By Earlier Event
Due 17 June 2004
Resolved 17 June 2004
Resolution: Verified windows met specifications and observed fiberglass repairs were conducted "in kind."
Construction/Loadline › Hull › Bottom Plating
Issued 7 April 2004
Resolved
Prepare marked areas in way of hull for further inspection. (Blistered FRP/gel coat)
Condition: Improper/Lack of Maintenance
Due 7 April 2004
Resolved 9 April 2004
Construction/Loadline › Hull › Bottom Plating
Issued 7 April 2004
Resolved
Pull fasteners for glass bottom as discussed with attending CG inspector.
Condition: Improper/Lack of Maintenance
Due 7 April 2004
Resolved 9 April 2004
Engineering › Steering Gear System › Rudder Stock
Issued 7 April 2004
Resolved
Replace rudder stop in way of starboard rudder.
Condition: Improper/Lack of Maintenance
Due 7 April 2004
Resolved 9 April 2004
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 7 April 2004
Resolved
Secure ladder in way of aft lazarrette.
Condition: Improper/Lack of Maintenance
Due 7 April 2004
Resolved 9 April 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 7 April 2004
Resolved
Properly terminate loose wiring in overhead near aft bulkhead of fuel tank compartment.
Condition: Improper/Lack of Maintenance
Due 7 May 2004
Resolved 9 April 2004
Stability › Watertight Integrity
Issued 7 April 2004
Resolved
Plug openings in forward bulkhead of fuel tank spacenear overhead, starboard side.
Condition: Improper/Lack of Maintenance
Due 7 May 2004
Resolved 9 April 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 7 April 2004
Resolved
Properly terminate, or remove, loose wiring in way of engine room.
Condition: Improper/Lack of Maintenance
Due 7 May 2004
Resolved 9 April 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 April 2004
Resolved
Renew cracked and corroded exhaust hoses in engine room for both MDE's
Condition: Improper/Lack of Maintenance
Due 7 May 2004
Resolved 9 April 2004
Fire Fighting › Means of Escape › Doorways
Issued 7 April 2004
Resolved
Demonstrate operation of the hatch to galley.
Condition: Improper/Lack of Maintenance
Due 7 May 2004
Resolved 7 April 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 February 2004
Resolved
Repair leak in way of raw water pump (starboard) prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Due 9 February 2004
Resolved 13 February 2004
Communications › Audible Communications › SPD (Other)
Issued 9 February 2004
Resolved
Repair speaker in way of the salon prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Due 9 February 2004
Resolved 12 February 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 February 2004
Resolved
Re-attach the upper deck awning stanchion prior to 9 MAR 2004.
Condition: Improper/Lack of Maintenance
Due 9 March 2004
Resolved 13 February 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 9 February 2004
Resolved
Make the port MSD operable and remove storage from the facility.
Condition: Improper/Lack of Maintenance
Due 9 February 2004
Resolved 9 February 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 February 2004
Resolved
Repair gangway gate (rail) on port side aft, prior to completion of hull examination.
Condition: Improper/Lack of Maintenance
Due 9 February 2004
Resolved 13 February 2004
Construction/Loadline › Hull
Issued 9 February 2004
Resolved
Make permenant repairs to the port and starboard gunnels IWO damage. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Due 9 February 2004
Resolved 13 February 2004
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 9 February 2004
Resolved
Renew ladder in way of fore peak prior to completion of drydock.
Condition: Placed in Improper Service
Due 9 February 2004
Resolved 13 February 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 February 2004
Resolved
Provide a complete first aid kit prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Due 9 February 2004
Resolved 13 February 2004
Fire Fighting › Fire Pumps › Arrangement
Issued 9 February 2004
Resolved
Provide a portable fire/bilge pump prior to 9 MAR 2004.
Condition: Improper/Lack of Maintenance
Due 9 June 2004
Resolved 13 February 2004
Operations/Management
Issued 15 July 2003
Resolved
Vessel will require additional re-inspection prior to 15 OCT 03 due to past deficiency history.
Due 15 October 2003
Resolved 9 February 2004
Resolution: Vessel is no longer on a quarterly inspection schedule.
Documentation › Safety/Response Plans/Programs
Issued 16 April 2003
Resolved
Provide approved plans for MSD holding tanks installed on board. LEGACY COMPONENT DESC: General Arrangement Plans
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 12 May 2003
Operations/Management
Issued 15 April 2003
Resolved
Vessel is required to conduct additional re-inspection prior to 15 JULY 03.
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 10 July 2003
Resolution: Satisfactory in-service inspection completed.
Electrical › Electrical Distribution System (service)
Issued 15 April 2003
Resolved
Provide covers for unused breakers in the main electrical breaker in E/R. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 12 May 2003
Engineering › Bilge Water Management System
Issued 15 April 2003
Resolved
Provide hose clamps on bilge piping system. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 12 May 2003
Electrical › Electrical Distribution System (service)
Issued 15 April 2003
Resolved
Provide cover for 220 volt outlet in E/R. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 12 May 2003
Electrical › Electrical Distribution System (service)
Issued 15 April 2003
Resolved
Provide electrical cover for cut out electrical junction box on compressor STBD side aft E/R. LEGACY COMPONENT DESC: Junction Box
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 12 May 2003
Electrical › Electric Supply System (service)
Issued 15 April 2003
Resolved
Provide covers for battery terminals in E/R. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 28 April 2003
Resolved 12 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 15 April 2003
Resolved
Remove sewage from MSD and repiar leak on port side MSD. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 12 May 2003
Lifesaving › Lifejacket/PFD (General)
Issued 15 April 2003
Resolved
Re-disribute life jackets throughout vessel IAW 46 CFR 180.78. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 12 May 2003
Navigation › Piloting/Steering
Issued 8 April 2003
Resolved
Provide current navigation publications IAW 46 CFR 184.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 8 April 2003
Resolved
Provide servicing report that fixed firefighting system has been serviced by a qualified servicing facility IAW 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2003
Lifesaving › Hand Flares
Issued 8 April 2003
Resolved
Provide distress flares and smoke signals IAW 46 CFR 180.68. In addition, separate or dispose of old flares. DO NOT STOW IN SAME CONTAINER. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2003
Operations/Management › Lifesaving
Issued 8 April 2003
Resolved
Provide written or verbal count ashore of passengers on board vessel IAW 49 C FR 185.504. Provide plan to MSO Miami.
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 12 May 2003
Electrical › Electrical Distribution System (service)
Issued 8 April 2003
Resolved
Remove dead-end wires from forward compartment (FWD lazaret). LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 12 May 2003
Lifesaving › Lifebuoys
Issued 8 April 2003
Resolved
Mark ring lifebuoy on stern with legible block capital letters and replace retro tape. Provide new bracket so that waterlight can be stowed with buoy. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2003
Documentation › Markings/Placards
Issued 8 April 2003
Resolved
Properly mark emergency broadcast placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2003
Electrical › Electrical Distribution System (service)
Issued 8 April 2003
Resolved
Provide panel to cover exposed wires under helm. LEGACY COMPONENT DESC: Panelboard
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 12 May 2003
Electrical › Lighting (emergency)
Issued 8 April 2003
Resolved
Repair emergency light in glass bottom viewing room and show proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2003
Engineering › Bilge Water Management System
Issued 8 April 2003
Resolved
Provide additional training to crewmembers on bilge/fire operation and show USCG Marine Inspector proper operation of bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2003
Engineering › Bilge Water Management System
Issued 8 April 2003
Resolved
Provide a portable hand bilge pump IAW 46 CFR 182.25-10 (e).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2003
Engineering › Bilge Water Management System
Issued 9 October 2002
Resolved
SUBMIT A SCHEDULE FOR RENEWAL OF ALL BILGE PIPING WHERE WASTED. LEGACY COMPONENT DESC: Piping
Due 9 October 2002
Resolved 12 May 2003
Navigation
Issued 9 October 2002
Resolved
pROVIDE CHARTS AND PUBLICATIONS IN ACCORDANCE WITH 46 CFR 184.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2002
Resolved 12 May 2003
Engineering › Bilge Water Management System › Pump
Issued 9 October 2002
Resolved
OPERATOR UNABLE TO DEMONSTRATE PROPER OPERATION OF BILGE PUMP
Due 9 October 2002
Resolved 9 October 2002
Resolution: FOLLOWING SEVERAL ATTEMPTS OPERATOR WAS ABLE TO PROVE PROPER OPERATION OF BILGE PUMP.
Stability › Incline Test
Issued 1 July 2002
Resolved
REMOVE ALL EXCESS STORES, OR PROVIDE DOCUMENTATION OF WEIGHT ADDED, OR CONDUCT NEW STABILITY TEST TO VERIFY ADEQUATE STABILITY IN CURRENT LOADED CONDITION.
Due 30 July 2002
Resolved 12 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 1 July 2002
Resolved
REMOVE BOTH SOFAS OR PERMANENTLY MOUNT IN AN APPROVED AREA WHICH DOES NOT INTERFER WITH EGRESS ROUTES.
Due 10 July 2002
Resolved 12 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 1 July 2002
Resolved
RELOCATRE COMPUTER EQUIPMENT IN PILOT HOUSE TO ALLOW EGRESS FROM SPACE.
Due 1 September 2002
Resolved 12 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 July 2002
Resolved
PERMANENTLY COVER OR INSTALL GUARDS IN WAY OF VIEWING HOLE IN BRIDGE DECK TO PREVENT CREW MEMBER FROM FALLING IN HOLE. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 17 July 2002
Resolved 12 May 2003
Documentation
Issued 29 November 2001
Resolved
Provide proof of participation in approved drug program, prior to carry passengers.
Condition: Unknown
Due 29 November 2001
Resolved 5 December 2001
Lifesaving
Issued 29 November 2001
Resolved
Conduct training on all aspects of vessel emergency procedures & equipment to crew and demostrate proficiency to CG inspector.
Condition: Unknown
Due 29 November 2001
Resolved 5 December 2001
Accommodation/Occupational Safety
Issued 29 November 2001
Resolved
Repair PA system prior to carriage of passengers.
Condition: Unknown
Due 29 November 2001
Resolved 8 January 2002
Lifesaving
Issued 29 November 2001
Resolved
Repair or replace waterlight for ring lifebouy.
Condition: Unknown
Due 29 November 2001
Resolved 5 December 2001
Navigation
Issued 29 November 2001
Resolved
Provide bridge log with required entries prior to carriage of passengers.
Condition: Unknown
Due 29 November 2001
Resolved 5 December 2001
Lifesaving
Issued 29 November 2001
Resolved
Provide means for pick up of MOB prior to carriage of passengers.
Condition: Unknown
Due 1 January 2002
Resolved 8 January 2002
Accommodation/Occupational Safety
Issued 29 November 2001
Resolved
Re-stow miscellaneous equipment in fwd. void.
Condition: Unknown
Due 1 January 2002
Resolved 8 January 2002
Navigation
Issued 29 November 2001
Resolved
Provided current navigational pubs prior to carriage of passengers.
Condition: Unknown
Due 29 November 2001
Resolved 5 December 2001
Electrical
Issued 16 February 2001
Resolved
Electrical connections are non regulation screw type and require replacement.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Lifesaving
Issued 16 February 2001
Resolved
FWD gaurd rail is missing several retaining screws.
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Electrical
Issued 16 February 2001
Resolved
Battery cover is missing on 12volt battery.
Condition: Unknown
Due 17 February 2001
Resolved 20 February 2001
Electrical
Issued 16 February 2001
Resolved
15kw Generator is securing when electrical load is applied, repair or replace prior to carriage of passengers.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Lifesaving
Issued 16 February 2001
Resolved
Sliding doors are missing retaining locks
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Lifesaving
Issued 16 February 2001
Resolved
Fuel tank space is not accessible due to excessive amounts of loose gear/spare parts and general storage.
Condition: Unknown
Due 17 February 2001
Resolved 20 February 2001
Lifesaving
Issued 16 February 2001
Resolved
Provide certification for at least 50% of deckhands in CPR/first aid.
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Engineering
Issued 16 February 2001
Resolved
Machinery guards are missing on both electrical generators.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001
Resolved
Exhaust insulation is missing on sections of exhaust piping.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Lifesaving
Issued 16 February 2001
Resolved
FWD railing hight is inadequate
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Engineering
Issued 16 February 2001
Resolved
S/S Generator has excessive jacket water pump leak and requires repair or replacement prior to carriage of passengers.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Electrical
Issued 16 February 2001
Resolved
Electrical breaker panels through-out vessel have no labels.
Condition: Unknown
Due 17 February 2001
Resolved 20 February 2001
Accommodation/Occupational Safety
Issued 16 February 2001
Resolved
There is no ventilation installed for diesel fuel tank space.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Lifesaving
Issued 16 February 2001
Resolved
Galley range is not secured and is held in place by electrical cord.
Condition: Unknown
Due 17 February 2001
Resolved 20 February 2001
Engineering
Issued 16 February 2001
Resolved
Stbd. MDE has oil leak and requires repair or replacement prior to carriageof passengers.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Navigation
Issued 16 February 2001
Resolved
Navigation lights are incorrectly mounted and require repair or replacement.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Electrical
Issued 1 December 1999
Resolved
Remove wing nuts from battery terminals and provide proper securing nuts.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Accommodation/Occupational Safety
Issued 1 December 1999
Resolved
Provide a lock and chain for MSD overboard valve.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Electrical
Issued 1 December 1999
Resolved
Secure all hazardous wiring in the engine room.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Electrical
Issued 1 December 1999
Resolved
Provide machinery guards on 20KW gen set in engine room.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Navigation
Issued 1 December 1999
Resolved
Install an operational compass with illumination for night ops.
Condition: Unknown
Due 16 December 1999
Resolved 3 December 1999
Fire Fighting
Issued 1 December 1999
Resolved
Provide three additional B-II portable extinguishers prior to sailing.
Condition: Unknown
Due 1 December 1999
Resolved 3 December 1999
Navigation
Issued 1 December 1999
Resolved
Provide a radio distress placard.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Fire Fighting
Issued 1 December 1999
Resolved
Amend emergency check off lists to include operation of the fixed fire fighting system.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Documentation
Issued 1 December 1999
Resolved
Begin conducting and logging crew training in emergency procedures.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Engineering
Issued 1 December 1999
Resolved
Label all fuel oil shut off valves.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Lifesaving
Issued 1 December 1999
Resolved
Label max. amount of passengers allowed on upper deck on ladderwells leading to 02 deck.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Lifesaving
Issued 1 December 1999
Resolved
Label all life preserver stowage locations throughout the vessel.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Lifesaving
Issued 1 December 1999
Resolved
Provide life preserver donning placards for all styles of PFD's on board and post in vicinity of stowage locations.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 1 December 1999
Resolved
Properly install bilge high level alarms panel at the pilot staion. Currently, the panel is make-shift.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Navigation
Issued 1 December 1999
Resolved
Provide proper navigation lights IAW with COLREGS 72 & Inland NAVRULES.
Condition: Unknown
Due 1 December 1999
Resolved 3 December 1999
Lifesaving
Issued 1 December 1999
Resolved
Provide retro-tape for ring life buoys and ensure that the vsl name is not stenciled on retro tape.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Fire Fighting
Issued 1 December 1999
Resolved
Label fire extinguisher stations in the galley and viewing room.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Documentation
Issued 3 December 1998
Resolved
PROVIDE FCC SAFETY CERTIFICATE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 27 May 1998
Resolved
PRIOR TO THE CARRAGE OF PASSENGERS, MAKE PERMANENT REPAIRS TO FWD DECK SUPPORT BEAM WERE CRACKED; NEXT TO HATCH.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Engineering
Issued 27 May 1998
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, REPLACE SEA WATER INTAKE HOSE TO GENERATOR SET.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Accommodation/Occupational Safety
Issued 27 May 1998
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, REPLACE PVC FITTINGS THAT ARE IN THE SEA WATER WASHDOWN PUMP INTAKE LINE.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Lifesaving
Issued 21 September 1993
Resolved
Total persons allowed on board is reduced to 90 until 4 servicable life jackets are placed aboard.
Condition: Unknown
Due 21 October 1993
Resolved 24 September 1993
Engineering
Issued 21 September 1993
Resolved
Stencil "EMERGENCY FUEL SHUT OFF" on deck near access to fuel valves as directed by CG inspector.
Condition: Unknown
Due 21 September 1993
Resolved 24 September 1993
Accommodation/Occupational Safety
Issued 13 October 1992
Resolved
VENT MSD HOLDING TANKS TO EXTERIOR OF VESSEL.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Navigation
Issued 13 October 1992
Resolved
REPAIR/REPLACE PORT RUDDER CARRIER BEAM.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Engineering
Issued 13 October 1992
Resolved
REPLACE PORT INBOARD EXHAUST ELBOW AT POINT OF COOLING WATER INJECTION.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992