Records from 1981 to 1999. Most recent: inspection, 31 August 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
31 August 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 79641
14 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810384
7 June 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1436223
22 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125545
24 March 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 65973
11 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 14235
4 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798608
29 June 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 83890
25 June 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130171
24 May 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452406
18 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 96836
5 February 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 122837
30 June 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424432
12 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778021
11 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 217531
7 May 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902062
30 April 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907475
18 April 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916141
21 February 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1217742
24 January 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212616
23 January 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232470
13 December 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222251
6 December 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920770
5 December 1989
Permit to Proceed · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910473
5 December 1989
MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920383
24 November 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1225669
18 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337907
13 April 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022373
27 March 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326794
8 December 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334314
31 October 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320098
29 January 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1293513
12 February 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1287158
28 January 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 976007
20 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285007
11 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963433
11 October 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973222
11 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272717
14 October 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281605
12 October 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 964746
14 March 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 964315
Lifesaving
Issued 24 May 1998
Resolved
Conduct operational test of lifeboat release gear under a load of 1.1 timesthe mass of the boat when loaded with its full complement of equipment and capacity, in presence of attending marine inspector or class surveyor. Alternative testing may be submitted to [name withheld] for review.
Condition: Unknown
Due 24 May 1998
Resolved 24 May 1998
Navigation
Issued 24 May 1998
Resolved
Adjust foghorn to sound at the interval of two seconds on and eighteen seconds off. Prove proper operation and log properly.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Lifesaving
Issued 24 May 1998
Resolved
Provide a 4 kilogram weighted lifering buoy for each of the bridge quick- release stations.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Electrical
Issued 24 May 1998
Resolved
Conduct satisfactory test of total rig emergency shutdown and log properly.
Condition: Unknown
Due 17 August 1998
Resolved 17 August 1998
Lifesaving
Issued 30 June 1997
Resolved
REPAIR AND PROPERLY LABEL GENERAL ALARM SYSTEM. SPECIFICALLY, REPAIR GENERAL ALARM BELLS IN KOOMEY ROOM AND ON BOW AND STERN MAIN DECK. MAKE ALARM SYSTEM AUDIBLE FROM ALL LOCATIONS.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Electrical
Issued 30 June 1997
Resolved
COMPLETE INSTALLATION OF DRILLER'S CONSOLES AND ENSURE PROPER OPERATION OF ALL PURGE ALARMS PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Navigation
Issued 30 June 1997
Resolved
DISPLAY MANEUVERING CHARACTERISTICS IN PILOTHOUSE.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Electrical
Issued 30 June 1997
Resolved
INSTALL FAN GUARD AND PROPERLY SECURE BATTERIES IN MAIN DECK BATTERY ROOM.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Engineering
Issued 30 June 1997
Resolved
ENSURE PROPER OPERATION OF FUEL OIL TRANSFER PUMPS, REMOTE FUEL OIL TRANSFER PUMP SHUTDOWNS AND POST FUEL OIL TRANSFER PROCEDURES. PROPERLY LABEL REMOTE FUEL OIL TRANSFER PUMP SHUTDOWN.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Engineering
Issued 30 June 1997
Resolved
OBTAIN AMERICAN BUREAU OF SHIPPING CERTIFICATION OF DYNAMIC POSITIONING SYSTEM.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Navigation
Issued 30 June 1997
Resolved
REPAIR ENGINE ORDER TELEGRAPH.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Fire Fighting
Issued 30 June 1997
Resolved
PROPERLY LABEL FIXED CO2 SYSTEM ALARM IN SCR ROOM.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Electrical
Issued 30 June 1997
Resolved
REPLACE OR REPAIR STARBOARD NO. 2 MOTOR AMPERAGE GAUGE.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Deck/Cargo
Issued 30 June 1997
Resolved
UPDATE REGISTER OF CARGO GEAR.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Lifesaving
Issued 30 June 1997
Resolved
PROPERLY LOG ALL REQUIRED DRILLS AND TESTS IN ACCORDANCE WITH 46 CFR 109. PLACE REQUIRED TRAINING MANUAL AND MAINTENANCE MANUAL FOR LIFESAVING GEAR ON BOARD IN ACCORDANCE WITH SOLAS CHAPTER III, REGULATION 18.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Fire Fighting
Issued 30 June 1997
Resolved
MAKE STAIRTOWER DOORS SELF-CLOSING AND CAPABLE OF LATCHING.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Documentation
Issued 30 June 1997
Resolved
OBTAIN AMERICAN BUREAU OF SHIPPING APPROVAL OF OPERATIONS MANUAL, CONSTRUCTION PORTFOLIO, FIRE CONTROL PLAN AND CLASSIFIED LOCATION PLAN.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Lifesaving
Issued 30 June 1997
Resolved
COMPLETE AMERICAN BUREAU OF SHIPPING WORKLIST FOR SAFETY EQUIPMENT CERTIFICATE.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Electrical
Issued 30 June 1997
Resolved
REMOVE ALL DEAD-END WIRING AND PROPERLY SECURE ALL WIRING WITH METAL BANDINGS.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Fire Fighting
Issued 5 December 1989
Resolved
PROVIDE TO [name withheld] OF DOT FACILITY APPROVAL FOR CO2 BOTTLES DONE IN DUBAI UAE OR HAVE RE-HYDROSTATICLLY TESTED AT APPROVED DOT FACILITY.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Engineering
Issued 5 December 1989
Resolved
03) INSTALL BILGE SENSOR IN PIPE TUNNEL
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Accommodation/Occupational Safety
Issued 5 December 1989
Resolved
PROVIDE FOR PLAN REVIEW COMPLETE INSTALLATION INFORMATION FOR THE FOLLOWINGA) NEW HOT WATER HEATERS, B) NEW WATER MAKER, C) TWO NEW AIR COMPRESSORS.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Deck/Cargo
Issued 5 December 1989
Resolved
01) SUPPLYTO [name withheld] SPECS, AND SOCIETY CLASSIFICATION DATA FOR PORTABLE HELO FUEL TANKS ON DECK (2) TWO EA.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Lifesaving
Issued 29 January 1986
Resolved
PROVIDE 2 TRAINABLE LIGHTS, ONE AT EACH LIFEBOAT STATION, TO BE CONNECTED TO EMERGENCY LIGHTING CIRCUIT.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Electrical
Issued 29 January 1986
Resolved
PROVIDE A GENERAL ALARM SOUND OR LIGHT DEVICE FOR NO. 3 CRANE.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Lifesaving
Issued 29 January 1986
Resolved
REPAIR PORT LIFEBOAT GRAB RAIL, STBD SIDE AFT.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Fire Fighting
Issued 29 January 1986
Resolved
REPLACE 2 NITROGEN BOTTLES FOR HELO DECK BV DC EXTINGUISHERS.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Fire Fighting
Issued 29 January 1986
Resolved
PROVIDE 1 ADDITIONAL 12' APPLICATOR FOR THE STBD HELO DECK FIRE HYDRANT.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Fire Fighting
Issued 29 January 1986
Resolved
PROVIDE A PRESSURE ACTIVATED SWITCH IN CO2 LINE FOR PAINT LOCKER VENTILATION FANS.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Construction/Loadline
Issued 29 January 1986
Resolved
ARRANGE HELO DECK DRAINS SO AS TO EMPTY INTO THE SEA VICE ONTO A LOWER DECK.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Lifesaving
Issued 29 January 1986
Resolved
VESSEL IS LIMITED TO THE CARRIAGE OF 100 PERSONS TOTAL UNTIL SUCH TIME AN ADDITIONAL USCG APPROVED 20 MAN INFLATABLE LIFERAFT IS PROVIDED, BUT NOT LATER THATN 29 MARCH 1986.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Accommodation/Occupational Safety
Issued 29 January 1986
Resolved
PROVIDE BORESCOPE FOR THE INTERNAL EXAMINATION OF THE MOTION COMPENSATION AND RISER TENSIONER CYLINDERS (20 TOTAL) IN LIEU OF BORESCOPE. NOW DESTRUCTIVE TESTING IN THE PRESENCE OF A CG INSPECTOR IS ACCEPTABLE.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Lifesaving
Issued 29 January 1986
Resolved
REPAIR STBD LIFEBOAT GRAB RAIL, PORT SIDE AFT.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Fire Fighting
Issued 29 January 1986
Resolved
PROVIDE 4 ADDITIONAL 4' APPLICATORS FOR ENGINEROOM HYDRANTS AS NECESSARY.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Lifesaving
Issued 28 January 1985
Resolved
TEST OUT BOTH LIFEBOATS IN WATER AND NEW DAVIT FALLS.
Condition: Unknown
Due 28 January 1985
Resolved 28 January 1985
Electrical
Issued 28 January 1985
Resolved
REPAIR LIGHT BRACKET TO DECK BOW LIGHT STBD.
Condition: Unknown
Due 28 January 1985
Resolved 28 January 1985
Deck/Cargo
Issued 28 January 1985
Resolved
INSTALL FLAME SCREEN TO ONE MARINE PORTABLE TANK.
Condition: Unknown
Due 28 January 1985
Resolved 28 January 1985
Deck/Cargo
Issued 28 January 1985
Resolved
SUBMIT PLAN FOR APPROVAL OF MARINE PORTABLE TANKS.
Condition: Unknown
Due 28 January 1985
Resolved 28 January 1985
Unknown
Issued 28 January 1985
Resolved
REPAIR EVAPORATOR.
Condition: Unknown
Due 28 January 1985
Resolved 28 January 1985
Fire Fighting
Issued 28 January 1985
Resolved
REPAIR FOAM TANK
Condition: Unknown
Due 28 January 1985
Resolved 28 January 1985
Fire Fighting
Issued 28 January 1985
Resolved
INSTALL FIRE CONTROL PLAN AT GANG WAY.
Condition: Unknown
Due 28 January 1985
Resolved 28 January 1985
Lifesaving
Issued 20 January 1984
Resolved
PROVIDE RETRO REFLECTIVE MATERIAL ON APPROXIMATELY 100 LIFE PRESERVES WITH 31 SQ. INCHES ON BOTH SIDES. 46 CFR 108.514 (F).
Condition: Unknown
Due 20 January 1984
Resolved 20 January 1984
Documentation
Issued 20 January 1984
Resolved
SUBMIT HAZARDOUS LOCATION PLAN TO [name withheld] FOR APPROVAL AND PROVIDEAPPROVED COPY ON BOARD THE VESSEL 46 CFR 111.05-5.
Condition: Unknown
Due 20 January 1984
Resolved 20 January 1984
Documentation
Issued 20 January 1984
Resolved
(CONTINUE FROM 5) 46 CFR 107.305 BB, CC, DD, EE, AND FF.
Condition: Unknown
Due 20 January 1984
Resolved 20 January 1984
Documentation
Issued 20 January 1984
Resolved
PROVIDE COAST GUARD APPROVED OPERATING MANUAL ON BOARD 46 CFR 109.121.
Condition: Unknown
Due 20 January 1984
Resolved 20 January 1984
Documentation
Issued 20 January 1984
Resolved
SUBMIT LIFESAVING PLAN TO [name withheld] FOR APPROVAL (AFTER INSTALLATIONOF ADDITIONAL LIFESAVING EQUIPMENT) AND PROVIDE APPROVED COPY ON BOARD
Condition: Unknown
Due 20 January 1984
Resolved 20 January 1984
Unknown
Issued 20 January 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE WESTERN OFFSHORE NO. IX
Condition: Unknown
Due 20 January 1984
Resolved 20 January 1984
Fire Fighting
Issued 20 January 1984
Resolved
PROVIDE TWO (2) UL OR FM APPROVED OXYGEN METERS 46 CFR 108.497 (C).
Condition: Unknown
Due 20 January 1984
Resolved 20 January 1984
Unknown
Issued 11 October 1982
Resolved
IF EQUIPMENT IS INTRINSICALLY SAFE PROPERLY INSTALL POWER LEADS USING EX- PLOSION PROOF JUNCTION BOXES AND EYS SEALS.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Electrical
Issued 11 October 1982
Resolved
MAKE ALL ELECTRICAL EQUIPMENT INSIDE AND WITHIN A 10' RADIUS OF BOTH PAINT LOCKERS SUITABLE FOR CLASS I, DIV II AREAS.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Electrical
Issued 11 October 1982
Resolved
REMOVE/REPLACE NEWLY INSTALLED GEOSERVICES EQUIPMENT IN MUD PIT AREA OR PROVIDE DOCUMENTATION THAT EQUIPMENT IS INTRINSICALLY SAFE.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
SUBMIT HAZARDOUS LOCATIONS PLAN TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Electrical
Issued 11 October 1982
Resolved
ON THE DRILL FLOOR A) PROVIDE EYS FITTING AT THE FOLLOWING LOCATIONS: 1. OVERHEAD JUNCTION BOXES (2) ABOVE THE MUD PUMP RPM GAUGE BOX 2. OVERHEAD JUNC
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
TION BOXES (4) ABOVE THE DESK 3. JUNCTION BOX ABOVE RECORD-A-GRAPH (4) MUL-TIBLE JUNCTION BOXES (2) UNDER DRILLERS CONSOLE (OR AIR PURGE BOXES) B) PRO
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
VIDE GENERAL ALARM HORN SUITABLE FOR HAZARDOUS LOCATIONS D) REMOVE NON-EXP-LOSION PROOF JUNCTION BOX AND TWO (2) WIRE SPLICES FROM BEHIND SUB SEA TV
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
UNIT E) PROVIDE DOCUMENTATION THAT INSTALLED INCADESCENT LIGHTS ARE SUITA- BLE FOR CLASS I DIV 2 AREAS G) REPLACE (1) NON-EXPLOSION PROOF JUNCTION BOX
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
BEHIND WATER COOLER H) REPLACE (1) NON-EXPLOSION PROOF JUNCTION BOX INTER- COM/ SPEAKER BOX AT DRILLERS CONSOLE.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Electrical
Issued 11 October 1982
Resolved
IN THE SHALE SHAKER AREA: A) REMOVE/REPLACE 2 NON-EXPLOSION PROOF SWITCHES ON THE AFT BULKHEAD B) REPLACE 2 NON-EXPLOSION PROOF MOTOR CONTROLLER ON
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
AFT BULKHEAD C. REPLACE 1 NON-EXPLOSION PROOF JUNCTION BOX D. INSTALL EYS SEALS THROUGHOUT (APPROX 8 SEALS NEEDED.)
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
AVAILIABLE FOR INSPECTION AT THE DISCRETION OF THE OCMI.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
SUBMIT STABILITY CALCULATIONS AND REVISED OPERATING MANUAL TO MMT NEW ORLEANS, LA FOR APPROVAL.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
PROVIDE 2 ASME RELIEF VALVES WITH HAND RELIEVING DEVICES, VALVES TO BE SET AT 40 PSIG AND INSTALLED ON 2 REMAINING BULK TANKS.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
BULK TANKS NOT TO BE USED UNTIL VALVES ARE INSTALLED.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Unknown
Issued 11 October 1982
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL WESTERN OFFSHORE NO IX, DN579406
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982
Electrical
Issued 11 October 1982
Resolved
REPLACE (1) NON-EXPLOSION PROOF JUNCTION BOX INTERCOM/SPEAKER BOX AT DRILLER CONSOLE.
Condition: Unknown
Due 11 October 1982
Resolved 11 October 1982