MAURY USCG vessel records Sign in
← All vessels

ANAIS

ANAIS is a 1966 freight ship. The Coast Guard has recorded 29 inspections since 1999, most recently in May 2008, along with 69 deficiencies and 17 operational controls.

Records from 1999 to 2008. Most recent: inspection, 16 May 2008.

Built
1966
Last inspected
16 May 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

E5U2061
490390
Flag
COOK ISLANDS
—
Maury page id
psix-490390

Inspections, by type

…with no type recorded20
Years with a record 8 calendar years (1999–2008)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it543 - Convention (Subpart B), Gross Ton
299 - Regulatory (Subpart C or D), Gross Ton
279 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

16 May 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3210679
14 May 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3206800
27 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3172170
25 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3170901
28 February 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3155020
21 February 2008 Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 3151111
5 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3125462
27 November 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3123643
26 November 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3104510
12 October 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3078350
30 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2919479
1 February 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2865170
1 February 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2872509
17 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2857655
18 April 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2627911
15 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2567271
27 September 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2502163
23 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2499221
1 September 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2480751
5 August 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2452070
26 May 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2079147
12 August 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1660174
15 February 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1486967
5 February 2002 Administrative Inspection · Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1484130
9 January 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1476935
9 January 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1482278
26 November 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 295569
2 October 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 287250
29 July 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428820

Deficiency record · 69

Electrical › Electric Generation Source (emergency) › Generator
Issued 28 February 2008 Resolved
Vessel has soft patches in day tank and fuel lines were installed without adminstration's approval. Improvised design at 3 way valve coming from additional filter not installed with class approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 28 February 2008 Resolved
Vessel is missing the Chief Engineer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 28 February 2008 Resolved
Chief Mate does not have a National license onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 28 February 2008 Resolved
Master needs to submit proof of original Flag Endorsement of National license.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 28 February 2008 Resolved
CCSSC not endorsed properly. Certificate is missing stamp or seal from Flag State.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pressure
Issued 28 February 2008 Resolved
Water pressure very low on emergency fire pump and main fire pump. Could not adequately reach all portions of the ship.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Fire Fighting › Fire Main › Condition
Issued 28 February 2008 Resolved
severe wastage with piping and valves in engine room for main fire system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 28 February 2008 Resolved
severe leakage of oil from MDE into bilge. Breather coated in oil. All components present a fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 February 2008 Resolved
Emergency fuel shut-off broken.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 12 October 2007 Resolved
light fixtures in engine room are not properly covered.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2007
Resolution: DEF corrected.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 October 2007 Resolved
bilge has excess oily mixtures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2007
Resolution: DEF corrected.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 October 2007 Resolved
Light list, Sailing Directions, and other required pubs not updated
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2007
Resolution: DEF corrected.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 12 October 2007 Resolved
FFE was not adequate to protect personnel from radiating heat, scalding, and burns.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2007
Resolution: DEF corrected.
Lifesaving › Buoyant Apparatus › Marking
Issued 1 February 2007 Resolved
Lifebuoys are not marked in accordance with regulations.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2007
Resolved 9 February 2007
Resolution: C.G. inspectors observed lifebuoys marked in accordance with regulations.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 February 2007 Resolved
Jacobs ladders observed in poor condition.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2007
Resolved 9 February 2007
Resolution: Jacobs ladder replaced.
Fire Fighting › Fire Hoses › Connections
Issued 1 February 2007 Resolved
Fire hose lockers missing spanner wrenches.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2007
Resolved 9 February 2007
Resolution: Replaced spanner wrenches for Fire hose lockers.
Lifesaving › Rescue Boat › Inflated Condition
Issued 1 February 2007 Resolved
Rescue boat leaking air in unknown location.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2007
Resolved 9 February 2007
Resolution: Proper repairs made to rescue boat.
Lifesaving › Inflatable Liferafts › Servicing
Issued 1 February 2007 Resolved
Liferafts last certification was in March 2005, overdue for servicing.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2007
Resolved 9 March 2007
Resolution: Liferafts serviced by authorized company in accordance with regulations.
Construction/Loadline › Markings › Load Line Mark
Issued 1 September 2005 Resolved
Loadline marking on hull is not tack welded, it was painted on . Prior to returning to US waters loadline mark must be permanently affixed to the hull of the vessel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 October 2005
Deck/Cargo › Cargo Stowage › General
Issued 1 September 2005 Resolved
Loaded vehicles were found on board with more than one quarter tank of fuel and the batteries were still connected to the ignition. Vsl required to unload cargo so USCG can inspect vehicles located in lower cargo hold. Vehicles must be loaded IAW 49CFR and de-hazmatted. Prior to loading, vehicles must be completely drained of all petroleum products and batteries disconnected
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2005
Construction/Loadline › Markings › Load Line Mark
Issued 5 August 2005 Resolved
Load line certifcate does not match loadline. Have flag state address.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2005
Lifesaving › Launching Appliances › Davit
Issued 5 August 2005 Resolved
Rescue boat davit wasted and missing bolts Fix to satisfaction of the administration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2005
Navigation › Piloting/Steering › Swing Meter
Issued 5 August 2005 Resolved
Rudder indicator angle is not calibrated with the bridge.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 September 2005
Construction/Loadline › Structures › Door
Issued 5 August 2005 Resolved
Have flag attest to the wooden door between steering and accomondation spaces.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 1 September 2005
Accommodation/Occupational Safety › Occupational Safety
Issued 5 February 2002 Resolved
No hot work allowed. LEGACY COMPONENT DESC: Welding/Hot Work
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 19 February 2002
Resolution: Received copy of Chemist Certificate #K49177
Accommodation/Occupational Safety › Occupational Safety
Issued 5 February 2002 Resolved
Do to the vessel having a second fire onboard, and the smell of diesel fuel throughout the vessel, a Marine Chemist must certify that the vessel is safe for hot work throughout the vessel. LEGACY COMPONENT DESC: Welding/Hot Work
Action required: 705 - Other - as specified
Due 12 February 2002
Resolved 8 March 2002
Resolution: Received Chemist Certificate #K49177
Documentation › Certificates/Documents
Issued 5 February 2002 Resolved
Vessel owner must arrange a meeting with the USCG MSO Miami office prior to 12 February 2002. At this meeting the owner must bring all original certificates for the vessel.
Action required: 705 - Other - as specified
Due 12 February 2002
Resolved 8 February 2002
Resolution: Conducted meeting, with SED, PMR, CRD, CGI, and Customs
Pollution Prevention/Response
Issued 5 February 2002 Resolved
All oil and water must be removed from the vessel and receipts provided to show the remove of the same.
Action required: 705 - Other - as specified
Due 12 February 2002
Resolved 19 February 2002
Resolution: Received copy of waste oil removal
System not recorded
Issued 26 November 2001 Resolved
Provide a class surveyor's report to MSO Miami attesting to the correction of all outstanding deficiencies including prior defs issued from 02 OCT 2001, prior to USCG re-inspection.
Condition: Unknown
Due 26 November 2001
Resolved 2 January 2002
Resolution: Deficiency cleared 02JAN02.
System not recorded
Issued 26 November 2001 Resolved
Prior to departure remove oily water from engine room bilge to an approved shore side facility and provide receipt to USCG MSO Miami.
Condition: Unknown
Due 26 November 2001
Resolved 2 January 2002
Resolution: Deficiency cleared 02JAN02.
Engineering
Issued 26 November 2001 Resolved
Prior to departure repair leak in the main engine cooling water pump.
Condition: Unknown
Due 26 November 2001
Resolved 2 January 2002
Resolution: Deficiency cleared 02JAN02.
Lifesaving
Issued 26 November 2001 Resolved
Prior to departue service port liferaft.
Condition: Unknown
Due 26 November 2001
Resolved 2 January 2002
Resolution: Deficiency cleared 02JAN02.
Navigation
Issued 2 October 2001 Resolved
Prove proper operation of navigation lights.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Fire Fighting
Issued 2 October 2001 Resolved
Perform satisfactory man-overboard and abandon ship drills in prescence of U.S. Coast Guard marine inspectors.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Navigation
Issued 2 October 2001 Resolved
Repair 20deg deviation between rudder angle indicator on the bridge and rudder stock.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Electrical
Issued 2 October 2001 Resolved
Provide guards on moving parts of main generator.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Navigation
Issued 2 October 2001 Resolved
Provide updated deviation table prior to next U.S. Port call.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Navigation
Issued 2 October 2001 Resolved
Adjust compasses so that both main and aux. compass are correct, prior to next U.S. port.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Fire Fighting
Issued 2 October 2001 Resolved
Secure upright fire extinguisher, engine room ladder.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 2 October 2001 Resolved
Repair hole wasted in overhead, main engine room, stbd. side aft.
Condition: Unknown
Due 10 October 2001
Resolved 1 September 2005
Electrical
Issued 2 October 2001 Resolved
Repair or replace cable to emergency generator shut down.
Condition: Unknown
Due 10 October 2001
Resolved 2 October 2001
Construction/Loadline
Issued 2 October 2001 Resolved
Pump excess oil from bilges in main engine room.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Navigation
Issued 2 October 2001 Resolved
Repair or replace main steering electrical motor in main steering gear room. Prior to departure.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Navigation
Issued 2 October 2001 Resolved
Correct rudder angle indicator on rudder stock to match bridge indicator.
Condition: Unknown
Due 10 October 2001
Resolved 2 October 2001
Fire Fighting
Issued 2 October 2001 Resolved
Refill both SCBA bottles for fire man's outfit.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Navigation
Issued 2 October 2001 Resolved
Repair or replace 360 deg. all around navigation light.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Construction/Loadline
Issued 2 October 2001 Resolved
Replace forward starboard cargo hold ballast tank cover.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Documentation
Issued 2 October 2001 Resolved
Translate all safety instructions and manuals into language understood by the crew.
Condition: Unknown
Due 10 October 2001
Resolved 2 October 2001
Documentation
Issued 2 October 2001 Resolved
Provide oiler in accordance with minimum safe manning document.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Navigation
Issued 2 October 2001 Resolved
Repair or replace daylight signal lamp.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Accommodation/Occupational Safety
Issued 2 October 2001 Resolved
Provide marine sanitation device on board vessel, in accordance with 33CFR 159.7
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Engineering
Issued 2 October 2001 Resolved
Repair fuel oil leak on the Main Generator.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Navigation
Issued 2 October 2001 Resolved
Provide line diagram for emergency steering on the bridge and the steering flat.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Electrical
Issued 2 October 2001 Resolved
Repair or replace explosion proof light fixtures in main engine compartment.
Condition: Unknown
Due 10 October 2001
Resolved 2 January 2002
Resolution: Deficiency cleared 02JAN02.
Lifesaving
Issued 2 October 2001 Resolved
Provide two lifebuoys on board in accordance with CCSS Certificate.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Lifesaving
Issued 2 October 2001 Resolved
Label lifebuoy on portside aft in accordance with LSA.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Lifesaving
Issued 2 October 2001 Resolved
Prove proper operation of rescue boat winch.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Fire Fighting
Issued 2 October 2001 Resolved
Provide Lifesaving/Firefighting Training Manual on board.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Fire Fighting
Issued 2 October 2001 Resolved
Provide instructions for lifesaving/firefighting maintenance, commence logging maintenance and required monthly/weekly PMS checks.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Fire Fighting
Issued 2 October 2001 Resolved
Replace fire hose mounted portside midship.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Electrical
Issued 2 October 2001 Resolved
Place emergency batteries forward in battery box.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Electrical
Issued 2 October 2001 Resolved
Repair exhaust leak for emergency generator.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Documentation
Issued 2 October 2001 Resolved
Maintain garbage log, prior to next U.S. port.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Lifesaving
Issued 2 October 2001 Resolved
Repair or replace starboard side grab-rail on rescue boat.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Electrical
Issued 29 July 1999 Resolved
install lagging on emergency generator exhaust piping above on main deck.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Fire Fighting
Issued 29 July 1999 Resolved
conduct fire and abandon ship drills in the presence of a USCG Inspector.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Documentation
Issued 29 July 1999 Resolved
prior to departure have class surveyor report addressing gross tonnage of vessel. Current intl tonnage cert does not have additional comment regarding tonnage as 299gt.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Electrical
Issued 29 July 1999 Resolved
replace lagging on emergency generator exhaust piping.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Fire Fighting
Issued 29 July 1999 Resolved
make permanent repairs to general purpose line in engine room.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.