MAURY USCG vessel records Sign in
← All vessels

MISTY

MISTY is a 1999 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1999, most recently in May 2026, along with 78 deficiencies.

Records from 1999 to 2026. Most recent: inspection, 27 May 2026.

Built
1999
Last inspected
27 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM 4761
490396
Flag
UNITED STATES
—
Maury page id
psix-490396

Inspections, by type

…with no type recorded3
Years with a record 25 calendar years (1999–2026)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 47

27 May 2026 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8373083
23 July 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8210446
25 November 2024 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8040703
21 August 2024 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7980131
30 August 2023 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7780848
8 December 2022 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7609023
8 August 2022 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7529226
21 July 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7264472
7 June 2021 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7206437
7 December 2020 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7109130
6 August 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7013193
7 November 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6844910
23 June 2019 Type not recorded
No type recorded · Station Chincoteague · USCG East District (CGD-E) · Activity 6722982
1 May 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6673341
5 December 2018 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6595752
29 May 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6428034
7 May 2018 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6409117
28 August 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6251150
6 December 2016 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6081874
8 July 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5938536
17 June 2016 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5909616
25 May 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5996435
6 August 2015 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5197512
12 August 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4952418
5 August 2014 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4940760
3 July 2012 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4365835
18 May 2012 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4261965
27 July 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4144305
14 January 2011 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3926741
13 January 2011 Hull Examination · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3924250
17 March 2009 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3434825
7 May 2008 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3189908
11 October 2007 Deadweight Survey · Examination of Repairs · Plan Review "T" Boat
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3166080
13 July 2005 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2425391
28 April 2005 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2344839
8 March 2005 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2305627
17 May 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2072112
9 June 2003 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1813012
19 March 2003 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1759098
2 May 2002 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1616094
2 April 2002 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1600113
17 September 2001 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1428090
6 June 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1066669
27 March 2001 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1418876
31 August 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 822174
2 May 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1421893
2 April 1999 Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446779

Deficiency record · 78

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 May 2026 Resolved
Vessel had severely faded exit signage on all 03 passenger exit locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2026
Resolved 3 June 2026
Resolution: New exit labels installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2026 Resolved
Master did not properly address passengers with reduced manning procedures in accordance with vessels documented procedures.
Action required: 10 - Deficiency Rectified
Resolved 27 May 2026
Resolution: cleared on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 August 2024 Resolved
Then number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A. 760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50mm (2 inches) high. Symbols must be at least 100mm (4 inches) square. 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 27 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 August 2023 Resolved
Table 181.500(b)—Required Portable Fire Extinguishers. Operating Station 10-B:C quantity- 01. Vessel had 01 5-B:C portable extinguisher at the operating station. 46 CFR 181.500(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2023
Resolved 11 September 2023
Resolution: Photo evidence recieved of new fire extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2023 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Both fuel fill pipes incorporated flexible house. The metallic section were not joined by a grounding wire. 46 CFR 182.445(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2023
Resolved 11 September 2023
Resolution: Photo evidence recieved of properly grounded fill pipes on both tanks.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 August 2023 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel operator could not provide portable fire extinguisher servicing report at time of inspection. 46 CFR 176.810(b)(1)(iv)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2023
Resolved 11 September 2023
Resolution: Photo evidence recieved of servicing report for fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 August 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Container markings were deteriorated and confusing. 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2023
Resolved 11 September 2023
Resolution: Photo evidence recieved of new markings on life jacket containers.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 August 2023 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Container was not watertight and marked flares. 46 CFR 185.614
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2023
Resolved 11 September 2023
Resolution: Photo evidence recieved of new watertight container with proper markings for distress signals.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 30 August 2023 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have any emergency instructions on board. 46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2023
Resolved 11 September 2023
Resolution: Photo evidence recieved of appropriate emergency instructions which were mounted correctly.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 August 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Some of the passenger seating was found to be partially unsecured to the deck. Required to be resolved prior to the completion of the next dry dock. 46 CFR 176.830(a)
Action required: 705 - Other - as specified
Due 31 December 2024
Resolved 23 July 2025
Resolution: Inspected satisfactory passenger seating.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 December 2022 Resolved
46 CFR 176.610(a) During examination all accessible parts of the vessel's underwater body shall be made available for examination. Identified cracked weld on the port pontoon forward spray plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 August 2023
Resolution: Checked port pontoon spray shield repair; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2022 Resolved
46 CFR 176.804(e) At each initial and subsequent inspection for certification of the vessel, the owner or managing operator shall be prepared to conduct tests and have vessel ready for inspections of machinery, fuel and piping systems, including inspection of all fuel systems. Fuel lines are deteriorated and need to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 August 2023
Resolution: Checked replaced fuel lines; all sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 July 2021 Resolved
Vessel's radio did not work properly during radio check. Complete repairs to the satisfaction of the MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2021
Resolution: MI's attended vessel, completed sat radio check.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 July 2021 Resolved
Vessel's Consortium had multiple employees expired. O/O provided updated list for Consortium. Corrected on the spot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2021
Resolution: O/O provided updated list for Consortium. Corrected on the spot. Verified during def check.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 July 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2021
Resolution: Operator completed required training and provided documentation.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 June 2021 Resolved
To maintain Single Operator Permit, Owner must provide documentation that each credentialed mariner who operates vessel is able to complete required safety emergencies by themselves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: Vessel got u/w with additional Captain to complete satisfactory man overboard drill
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 June 2021 Resolved
Life rings Type II retroreflective tape was wasted. Replace tape to satisfaction of OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: O/O marked life ring with new Type II tape
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2021 Resolved
Each vessel must be equipped with two portable lights. Vessel only had one light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: O/O placed two operable flashlights on board.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 June 2021 Resolved
Vessels charts and publication were expired. Required to provide up to date charts and pubs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2021
Resolution: MI's verified updated charts on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 June 2021 Resolved
Vessel's master did not keep ships whistle on board. Master provided vessel with a whistle.
Action required: 10 - Deficiency Rectified
Due 7 June 2021
Resolved 7 June 2021
Resolution: Vessel had adequate sound signalling device onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 June 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: O/O provided valid license
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 June 2021 Resolved
Vessel's FCC Safety Cert was expired. Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: O/O provided valid safety certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2020 Resolved
Number and indentification of the items stowed inside, and their sizes, must be marked clearly in legible letters and numbers on each container. Found life jacket stowage container labled incorrectly. Relable to reflect amount of life jackets stowed in location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 18 August 2020
Resolution: relabled life jacket stowage correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2020 Resolved
Each floating waterlight must be approved in accordance with 161.010. Found incorrect model number battery in waterlight. Replace with approved battery type.
Action required: 705 - Other - as specified
Due 20 August 2020
Resolved 18 August 2020
Resolution: Operator provided approved battery installed in waterlight.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 November 2019 Resolved
Portable fire extinguisher's annual maintenance tag was invalid. Vessel's portable extinguishers must be annually maintained by a state or local jurisdiction, and the owner or managing operator must provide satisfactory evidence. Provide fire extinguisher's servicing report. 46CFR176.810(b)(1)(iv)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 22 April 2020
Resolution: O/O submitted pictures of extinguisher with new servicing tag attached, and invoice from servicer. cleared def based on objective evidence of compliance.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2019 Resolved
Non-marine cable was being used to power navigation lights. Cable for power circuits must be listed UL Boat or UL Marine Cable. Remove non-marine cable. 46CFR183.340(d)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 22 April 2020
Resolution: O/O submitted pictures of boat cable installed and purchase receipt. Cleared def based on objective evidence of compliance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2019 Resolved
Found FWD and AFT portable fire extinguisher brackets corroded. Replace both with manufacturer approved marine grade brackets. 46CFR §181.520
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2019
Resolved 16 August 2022
Resolution: Vessel replaced fire extinguisher brackets.
Lifesaving › Hand Flares › Quantity
Issued 7 May 2018 Resolved
Vessel was missing two of the required six distress signals required.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 May 2018
Resolved 7 May 2018
Resolution: Vessel rep acquired the two required distress signals.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 May 2018 Resolved
Vessel's lifeline must be replaced with a line that meets the requirements (breaking strength) of 46 CFR 180.70(c).
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 May 2018
Resolved 7 May 2018
Resolution: Vessel acquired and installed appropriate lifeline.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2018 Resolved
The forward masthead navigation light does not have appropriate arc of visibility as per the applicable Nav Rules. Vessel is restricted from resticted visibility and night time ops.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 29 May 2018
Resolution: The forward masthead navigation light was replaced with one meeting arc of visibility req'ts in Nav. Rules.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2018 Resolved
Remove twist-on wire nuts for masthead navigation lights and make ready for inspection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 29 May 2018
Resolution: Twist-on wire nuts were removed in new masthead navigation light installation.
Electrical › Electric Generation Source (service) › Switch
Issued 7 May 2018 Resolved
Cables and wires aboard the vessel are not supported with metal supports.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 29 May 2018
Resolution: Cables are wires were supported with metal supports.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2018 Resolved
Permanently install stern light in compliance with applicable Nav. Rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 29 May 2018
Resolution: Stern light was permanently installed to the satisfaction of the attending marine inspector.
Lifesaving › Hand Flares › Quantity
Issued 28 August 2017 Resolved
Vessel has only four red flares. Vessel is required to carry six total distres signals. Acquire two more distress signals of the appropriate type. 46 CFR 180.68(b)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 August 2017 Resolved
Port side running light is malfunctioning. All vesels mut have navigation lights. Vessel is restricted to daytime operations. 46 CFR 183.420
Condition: Improper Installation
Due 11 September 2017
Resolved 6 September 2017
Resolution: Attended the vessel and witnessed the proper operation of the port side navigation light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 August 2017 Resolved
Vessel has expired aspirin in first aid kit. First aid kit must be in compliance with 46 CFR 160.041. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Due 11 September 2017
Resolved 6 September 2017
Resolution: Vessel updated first aid kit with new bottle of aspirin.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 28 August 2017 Resolved
Vessel does not have fire extinguisher servicing documentation. Owner shall provide satisfactory evidence of extinguisher servicing. 46 CFR 176.810(b)(1)
Condition: Improper/Lack of Maintenance
Due 11 September 2017
Resolved 6 September 2017
Resolution: Vessel provided satisfactory portable fire extinguisher servicing records.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 August 2017 Resolved
Vessel does not have up-to-date tide and current tables. Vessel must carry adequate and up-to-date tide and current tables. 46 CFR 184.420(a)(3 & 4)
Condition: Invalid
Due 11 September 2017
Resolved 6 September 2017
Resolution: Vessel provided current copies of tide and current charts for their area of operation.
Navigation › Piloting/Steering › Marine Charts
Issued 17 June 2016 Resolved
Found navigation charts are expired. Replace with up-to-date charts.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 8 July 2016
Resolution: Provided current charts.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 June 2016 Resolved
Found First Aid kit not w/in compliance. Provide proof of items replaced IAW 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 8 July 2016
Resolution: Provided replacement items for first aid kit.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 June 2016 Resolved
Found waterlight inoperable. Provide proof of proper operation. Vessel is limited to daytime operations.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 8 July 2016
Resolution: Waterlight was operable.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 17 June 2016 Resolved
Found employees not enrolled in the consortium, Owner to to provide proof of employees’ enrollment in consortium.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 8 July 2016
Resolution: Provided updated drug consortium with seasonal hires.
Navigation › Piloting/Steering › Marine Charts
Issued 6 August 2015 Resolved
Vessel does not have up to date charts or tidal current tables. Provide up to date charts and currents to the satisfaction of the CGMI.
Due 3 September 2015
Resolved 31 August 2015
Resolution: Vessel provided proof of current charts and tidal currents.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 5 August 2014 Resolved
Master was unable to locate his mariner credentials for over an hour.
Action required: 705 - Other - as specified
Resolved 5 August 2014
Resolution: Master eventually located his license, which was on board the vessel the entire time in a waterproof container. Stressed the importance of possessing original license and not copies while operating the vessel.
Fire Fighting › Fire Bucket › Lanyard
Issued 5 August 2014 Resolved
Vessel's fire buckets were missing their required lanyards. Master had previously removed the lanyards to mark a submerged hazard to navigation, but failed to replace them.
Action required: 705 - Other - as specified
Resolved 5 August 2014
Resolution: Master replaced the lanyards during annual inspection.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 5 August 2014 Resolved
Flexible fuel fill pipes on fuel tanks not properly joined by a conductor for protection against generation of a static charge when filling with fuel. Provide marine inspector with evidence of proper grounding.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 September 2014
Resolved 8 August 2014
Resolution: Received e-mail from vessel''s master providing photographic evidence of properly bonded flexible fuel fill pipes.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 August 2014 Resolved
Contents of first aid kit on board vessel were expired. Provide marine inspector with evidence of complete and valid first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2014
Resolved 12 August 2014
Resolution: Master provided photographic/electronic evidence of the purchase of complete and valid first aid kit.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 May 2012 Resolved
Vessel had one all around white light in place of separate mast head light and stern light. Due to vessel size, greater than 12 meters, vessel is required to have a separate mast head light and stern light in addition to an all around white light. Vessel is restricted to operate during daylight hours only and is not to operate in times of restricted visibility.
Condition: Improper Installation
Due 18 June 2012
Resolved 3 July 2012
Communications › Visual Communication › Warning Sign (gangway)
Issued 7 May 2008 Resolved
Post all placards and emergency instructions
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 21 May 2008
Resolution: Cited this date.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 7 May 2008 Resolved
Develop plan to record passenger counts per 46 CFR 185.505
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 21 May 2008
Resolution: Sighted this date
Construction/Loadline › Markings › Fresh Water Load Line
Issued 7 May 2008 Resolved
Mark loading marks on hull per approved stability letter
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 21 May 2008
Resolution: Sighted this day.
Engineering › Bilge Water Management System › Pump
Issued 7 May 2008 Resolved
Prove hand bilge pump will reach all compartments per 46 CFR 185.520
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 21 May 2008
Resolution: Sighted this day.
Documentation › Certificates/Documents › Construction and Equipment Certificate (DSC)
Issued 7 May 2008 Resolved
Obtain approved plans for all modifications
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2008
Resolved 7 May 2008
Resolution: Sighted this day.
Construction/Loadline › Hull › Stool
Issued 8 March 2005 Resolved
REMOVE CONDENSATION BUILD-UP FROM ALL PORT PONTTON CHAMBERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 8 March 2005
Construction/Loadline › Hull › Stringer
Issued 8 March 2005 Resolved
REPAIR THE FOUR PONTOON TO DECK FRAME CONNECTIONS ON THE STARBOARD INBOARD AFT AREA WHERE THE BOLTS HAVE PULLED THRU THE FRAME.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 8 March 2005
Electrical › Electrical Distribution System (service)
Issued 9 June 2003 Resolved
Provide wiring IAW 46CFR Part 183 under steering console. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Electrical › Electrical Distribution System (service)
Issued 9 June 2003 Resolved
Raise and properly support wiring for outboard motor from water level (STBD) pontoon LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 June 2003 Resolved
Replace expired asprin and eye wash from first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Electrical › Electrical Distribution System (service)
Issued 9 June 2003 Resolved
Remove or re-wire fwd spot lights. LEGACY COMPONENT DESC: Conductor
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Resolution: Removed
Lifesaving › Hand Flares
Issued 9 June 2003 Resolved
Provide two (additional) CG approved distress signals. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2003
Electrical › Electrical Distribution System (service)
Issued 9 June 2003 Resolved
Remove all wire nuts from accomodation light as well as am/fm radio. Solder or use butt connectors. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Engineering › Steering Gear System
Issued 9 June 2003 Resolved
Remove old steering arm from fwd section of engine.
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Navigation › Collision/Grounding Avoidance
Issued 9 June 2003 Resolved
Repair all around stern/anchor light. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Navigation › Piloting/Steering
Issued 9 June 2003 Resolved
Provide nautical chart for area of operation. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Navigation › Piloting/Steering
Issued 9 June 2003 Resolved
Provide light list, coast pilot and tide tables. Applicable sections from these pubs may be photocopied or provide Reeds Nautical Almanac LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Resolution: Reeds provided
Engineering › Gasoline Engine (propulsion)
Issued 9 June 2003 Resolved
Show proper operation of port outboard motor prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2003
Resolution: Outboard repaired, operational test SAT
Operations/Management
Issued 9 June 2003 Resolved
Provide 46 CFR Subchapter "T"
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 12 June 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 2 April 2002 Resolved
Replace bracket for B-I fire extinguisher. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 2 May 2002
Resolved 2 May 2002
Resolution: VISITED VESSEL, CLEARED DEFICIENCY.
Electrical › Electrical Distribution System (service)
Issued 2 April 2002 Resolved
Bundle wires and cables together for STBD engine where they exit the stern of the vessel and make their turn for the engine. Make so wires and cables are not being exposed to thru-water wave action LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 2 May 2002
Resolved 2 May 2002
Construction/Loadline › Hull
Issued 2 April 2002 Resolved
Repair port engine bracket. Fracture is approx 6 inches long on inboard side of port engine bracket and runs longitudinally. Haul vessel out of water so Marine Inspector can better assess extent of fracture. LEGACY COMPONENT DESC: Bracket
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2002
Resolved 2 May 2002
Resolution: BIG AL''S WELDING COMPLETED REPAIRS. BEAD RUN ON TOP AND BOTTOM OF PORT ENGINE BRACKET. BRACKET WAS ORIGINALLY BENT VICE WELDED. STRESS FROM MOTORS HAD FRACTURED THESE AREAS WHICH WERE BENT. REPAIR SAT.
Construction/Loadline
Issued 17 September 2001 Resolved
Make permenant repair to stbd pontoon. Replace as original or submit repairplan proposal. To be completed prior to carrying passengers.
Condition: Unknown
Due 18 September 2001
Resolved 17 September 2001
Lifesaving
Issued 27 March 2001 Resolved
OBTAIN LIFEJACKET DONNING PLACARDS FOR BOTH STYLE OF LIFEJACKETS.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Navigation
Issued 27 March 2001 Resolved
REPAIR STERN LIGHT.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001 Resolved
REPAIR HOLE IN HULL ON STARBOARD BOW COMPARTMENT.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Fire Fighting
Issued 27 March 2001 Resolved
SERVICE AND HYRDO TEST ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Lifesaving
Issued 2 May 2000 Resolved
PROVIDE PROCEDURE FOR CONDUCTING PASSENGER SAFETY ORIENTATION.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Lifesaving
Issued 2 May 2000 Resolved
PROVIDE UPDATED FIRST AID KIT IN ACCORDANCE WITH 46CFR160.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Documentation
Issued 2 May 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.