Records from 2016 to 2024. Most recent: inspection, 2 May 2024.
Documentation record
Registered dimensions (L × B × D)39.0 ft × 13.4 ft × 6.6 ft
Registered tonnagegross 18 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMORGAN YACHT CORPORATION · LARGO, FL, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST PETERSBURG, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
2 May 2024
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7905488
8 January 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7819798
3 February 2023
Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7611373
14 February 2022
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7396054
22 July 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7013146
13 May 2020
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6948787
9 January 2020
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6847196
15 May 2019
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6676283
14 February 2018
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6354848
6 December 2017
Internal Structural Exam · Administrative Inspection · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6319777
17 May 2016
Examination of Repairs · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5879251
13 January 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5796094
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 26 August 2025
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. In lieu of a rescue boat the vessel may use a rescue platform in accordance with local OCMI policy. When deployed, the platform must be out of the water. Adjust platform so that it rests out of water when deployed. 46 CFR 185.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2025
Resolved 3 September 2025
Resolution: Platform adjusted sat.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 26 August 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
Emergency instructions do not align with the vessel type or the actions taken by the crew. Instructions to be updated to align with the vessel type and the actions taken by the crew. 46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2025
Resolved 15 September 2025
Resolution: Emergency instruction amended.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 May 2024
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel was due for renewal COI inspection on 16FEB22 and has yet to receive a renewal COI inspection. Vessel shall not operate with passengers until new COI has been issued. - 46 CFR 176.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2025
Resolution: COI issued.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 May 2021
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel's annual was due no later 16MAY21. Vessel is still awaiting new mast and is unable to complete inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2023
Resolution: Vessel is not currently operating and undergoing re-certification process.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 July 2020
Resolved
The design, materials, and construction of mast, post, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. The hull structure must be adequately reinforced to ensure sufficient strength and resistance to plate buckling. The cognizant OCMI may require the owner to submit detailed calculations on the strength of the mast, post, yards, booms, bowsprits, and standing rigging to the Marine Safety Center for evaluation. Vessel plans to replace all Mast, booms, and standing/running rigging. Prior to replacing, submit drawings and calculations to the Marine Safety Center per MSC plan review guide H1-15.
46 CFR 177.330
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2020
Resolved 10 February 2023
Resolution: Vessel has been de-masted and will only operate as a motor yacht.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 July 2020
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination.
Make vessel available for examination of damage.
46CFR176.600(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2020
Resolution: Vessel currently in drydock conducting repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 July 2020
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service.
Make mast suitable for the intended service.
46CFR177.330
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2023
Resolution: Vessel has been de-masted and will only operate as a motor yacht.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 May 2020
Resolved
46 CFR 180.64 Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
Vessel has EPIRB mounted under bimini top. Move EPIRB and mount to a float free location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 22 May 2020
Resolution: EPIRB moved to aft deck away from any overhangs or covers.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2020
Resolved
46 CFR 181.450 An independent modular smoke detecting unit must: Meet UL 217 (incorporated by reference, see 46 CFR 175.600) and be listed as a “Single Station Smoke detector—Also suitable for use in Recreational Vehicles,”
Smoke detector located in aft compartment does not meet requirements as a "Single Station Smoke detector-Also suitable for use in recreational vehicle." Replace with approved smoke detector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 2 June 2020
Resolution: Operator purchased and installed smoke detector meeting single station smoke detector for use in recreational vehicles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2019
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck.
MI observed emergency fuel shut off valve for main diesel engine inoperable. Repair / replace and prove proper operation of valve.
IAW: 46 CFR 182.20-40 (b)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2019
Resolution: MI verified proper operation of emergency fuel shutoff valve.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2019
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection.
MI observed portable fire extinguisher in way of head missing manufacturer's mounting bracket and sign. Install bracket and sign.
IAW: 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 24 May 2019
Resolution: O/O properly mounted fire extinguisher in bracket and posted sign.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 15 May 2019
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
Emergency broadcast placard was posted with inaccurate call sign. Post broadcast placard with correct call sign in accordance with FCC Station License.
IAW: 46 CFR 184.506
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 24 May 2019
Resolution: O/O corrected emergency broadcast placard with FCC Station License call-sign.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2019
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support.
IAW: 46 CFR 183.340 (b) (4)
MI observed the use of plastic tie wraps supporting cable runs in engine compartment. Install metal supports for cable runs and limit use of plastic tie wraps to bundling.
IAW:
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 10 June 2019
Resolution: MI verified O/O replaced electric cable zip tie supports with metallic supports.
Stability › Watertight Integrity › General
Issued 16 January 2018
Resolved
Replace engine room sea valve at starboard aft hull. 46 CFR 171.119(b)
Action required: 705 - Other - as specified
Resolved 19 January 2018
Resolution: Ball valve replaced and operates SAT.
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 16 January 2018
Resolved
Replace cracked headstay anchor bracket in kin to the satisfaction of marine inspector. 46 CFR 176.25-5
Action required: 705 - Other - as specified
Resolved 14 February 2018
Resolution: Headstay plate repaired and tested under load SAT.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 February 2017
Resolved
First Aid kit items expired.
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 16 February 2017
Resolution: Replaced new in kind.
Communications › Alarms/Indicators › Fire Alarm
Issued 16 February 2017
Resolved
Pre-engineered system (Fire-boy) did not function as designed.
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 16 February 2017
Resolution: Connected solenoid shut-off wire.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 February 2017
Resolved
Ring buoy had no vessel name & reflective tape does not reflect.
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 16 February 2017
Resolution: Marked name and applied new tape to ring.