← All vessels
ENTERPRISE
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named ENTERPRISE
ENTERPRISE is a 1976 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1985, most recently in May 2024, along with 84 deficiencies.
Records from 1985 to 2024. Most recent: inspection, 2 May 2024.
- Built
- 1976
- Last inspected
- 2 May 2024
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 84 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
579423
WDI8330
49040
Flag
UNITED STATES
367434440, 367737530 (licence lapsed)
Maury page id
psix-49040
Inspections, by type
…with no type recorded4
Years with a record
35 calendar years (1985–2024)
The 69 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)39.0 ft × 13.4 ft × 6.6 ft
Registered tonnagegross 18 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMORGAN YACHT CORPORATION · LARGO, FL, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST PETERSBURG, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI8330MMSI 367737530 · expired · compulsorily equipped · granted 1 June 2016, cancelled 4 July 2026
WCZ6547MMSI 367434440 · expired · compulsorily equipped · granted 22 December 2009, cancelled 4 April 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 69
2 May 2024
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7905488
8 January 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7819798
3 February 2023
Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7611373
14 February 2022
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7396054
22 July 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7013146
13 May 2020
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6948787
9 January 2020
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6847196
15 May 2019
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6676283
14 February 2018
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6354848
6 December 2017
Internal Structural Exam · Administrative Inspection · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6319777
17 May 2016
Examination of Repairs · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5879251
13 January 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5796094
13 May 2012
Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4311495
12 May 2012
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4350813
9 January 2012
Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4221783
8 January 2010
Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3660726
18 March 2009
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3436055
21 April 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3232027
31 January 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3134133
22 January 2007
Hull Examination · Plan Review "T" Boat · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2854457
9 March 2006
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2597936
22 September 2005
Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2497657
16 February 2005
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2293329
9 February 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2000360
22 October 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1933773
19 September 2003
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1901743
12 August 2003
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1874436
20 February 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1744573
12 February 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1486120
24 January 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1479529
14 August 2001
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448335
28 June 2001
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1067759
2 March 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058138
5 February 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399538
15 May 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1049404
31 January 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460395
16 September 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 812596
17 August 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 777927
16 July 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1458668
18 March 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1453622
10 February 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399043
17 February 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1113535
8 July 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1413203
13 February 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1398608
1 February 1996
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1078485
11 July 1995
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1191321
18 January 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 831658
3 February 1994
Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 854461
14 July 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1157118
25 February 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1146894
27 February 1992
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 959281
22 July 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 940790
4 March 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232765
7 March 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1218238
21 February 1990
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1243136
9 January 1990
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214013
14 December 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 928075
2 October 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1332012
25 September 1989
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1207579
14 March 1989
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1204652
11 January 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 886587
14 July 1988
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1344955
22 February 1988
Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1196513
12 March 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1323565
26 February 1987
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1309878
15 January 1987
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1007964
13 June 1986
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 995140
12 March 1986
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1302104
28 February 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1287163
Deficiency record · 84
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 26 August 2025
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. In lieu of a rescue boat the vessel may use a rescue platform in accordance with local OCMI policy. When deployed, the platform must be out of the water. Adjust platform so that it rests out of water when deployed. 46 CFR 185.700(a)
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 26 August 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
Emergency instructions do not align with the vessel type or the actions taken by the crew. Instructions to be updated to align with the vessel type and the actions taken by the crew. 46 CFR 185.510(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 May 2024
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel was due for renewal COI inspection on 16FEB22 and has yet to receive a renewal COI inspection. Vessel shall not operate with passengers until new COI has been issued. - 46 CFR 176.100
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 May 2021
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel's annual was due no later 16MAY21. Vessel is still awaiting new mast and is unable to complete inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 July 2020
Resolved
The design, materials, and construction of mast, post, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. The hull structure must be adequately reinforced to ensure sufficient strength and resistance to plate buckling. The cognizant OCMI may require the owner to submit detailed calculations on the strength of the mast, post, yards, booms, bowsprits, and standing rigging to the Marine Safety Center for evaluation. Vessel plans to replace all Mast, booms, and standing/running rigging. Prior to replacing, submit drawings and calculations to the Marine Safety Center per MSC plan review guide H1-15.
46 CFR 177.330
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 July 2020
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination.
Make vessel available for examination of damage.
46CFR176.600(d)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 July 2020
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service.
Make mast suitable for the intended service.
46CFR177.330
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 May 2020
Resolved
46 CFR 180.64 Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
Vessel has EPIRB mounted under bimini top. Move EPIRB and mount to a float free location.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2020
Resolved
46 CFR 181.450 An independent modular smoke detecting unit must: Meet UL 217 (incorporated by reference, see 46 CFR 175.600) and be listed as a “Single Station Smoke detector—Also suitable for use in Recreational Vehicles,”
Smoke detector located in aft compartment does not meet requirements as a "Single Station Smoke detector-Also suitable for use in recreational vehicle." Replace with approved smoke detector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2019
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck.
MI observed emergency fuel shut off valve for main diesel engine inoperable. Repair / replace and prove proper operation of valve.
IAW: 46 CFR 182.20-40 (b)(3)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2019
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection.
MI observed portable fire extinguisher in way of head missing manufacturer's mounting bracket and sign. Install bracket and sign.
IAW: 46 CFR 181.520
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 15 May 2019
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
Emergency broadcast placard was posted with inaccurate call sign. Post broadcast placard with correct call sign in accordance with FCC Station License.
IAW: 46 CFR 184.506
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2019
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support.
IAW: 46 CFR 183.340 (b) (4)
MI observed the use of plastic tie wraps supporting cable runs in engine compartment. Install metal supports for cable runs and limit use of plastic tie wraps to bundling.
IAW:
Stability › Watertight Integrity › General
Issued 16 January 2018
Resolved
Replace engine room sea valve at starboard aft hull. 46 CFR 171.119(b)
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 16 January 2018
Resolved
Replace cracked headstay anchor bracket in kin to the satisfaction of marine inspector. 46 CFR 176.25-5
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 February 2017
Resolved
First Aid kit items expired.
Communications › Alarms/Indicators › Fire Alarm
Issued 16 February 2017
Resolved
Pre-engineered system (Fire-boy) did not function as designed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 February 2017
Resolved
Ring buoy had no vessel name & reflective tape does not reflect.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 26 February 2007
Resolved
Demonstrate main diesel engine shutdown and restart as required by fixed fire fighting extinguishing system per 46 CFR 181.420(a)(3).
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 January 2007
Resolved
Provide a USCG Approved waterlight for the ring buoy.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 22 January 2007
Resolved
Replace current independent smoke detector in the aft below deck cabin with a recognized UL 217 Recreational Vehicle smoke detector as identified by 46 CFR 181.450.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 22 January 2007
Resolved
Investigate and determine if installed 12VDC fixed fire detection system in the machinery compartment meets USCG accepted UL supervised system. If not, comply with item #4.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 22 January 2007
Resolved
Provide USCG approved 12 VDC fixed fire detection system for the machinery compartment.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 22 January 2007
Resolved
Provide B-II portable fire extinguisher for machinery compartment within 5 yr hydrostatic test date.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 22 January 2007
Resolved
Provide vessel with oil pollution placard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 9 March 2006
Resolved
Properly mount CO2 applicator as outlined in 46CFR181.400(b)(5)(ii). Right now, the bottle is mounted and they open a inspection cover and place the applicator inside the engine room. This allows air into the compartment and the applicator isn't permanently mounted as outlined in the regulation. POC came up with a correction while onboard, but will need a few days to install.
Stability › Severe Wind/Roll › General
Issued 22 September 2005
Resolved
Provide a 3rd party report on the condition of mast and associated sailing gear above the main deck.
Construction/Loadline › Structures
Issued 22 October 2003
Resolved
MAKE PERMANENT REPAIRS TO CHAIN PLATES, JIB HALYARD, AND FORESTAY AS OUTLINED IN RIGGING REPORT DATED 15OCT03. LEGACY COMPONENT DESC: Rigging
Construction/Loadline › Penetrations
Issued 19 September 2003
Resolved
REPLACE STARBOARD FORWARD OUTBOARD SEA VALVE PRIOR TO SPLASHING OF VESSEL. LEGACY COMPONENT DESC: Sea Valve
Construction/Loadline › Penetrations
Issued 19 September 2003
Resolved
REPLACE AFT PORT SEA VALVE PRIOR TO SPLASHING OF VESSEL. LEGACY COMPONENT DESC: Sea Valve
Construction/Loadline › Structures
Issued 19 September 2003
Resolved
PROVIDE 3RD PARTY RIGGING REPORT. LEGACY COMPONENT DESC: Rigging
Operations/Management › Drug and Alcohol Testing
Issued 24 January 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting › Fixed Fire Detection System
Issued 24 January 2002
Resolved
DEMONSTRATE/PROVE PROPER OPERATION OF ENGINE ROOM HEAT DETECTION. LEGACY COMPONENT DESC: Heat Detectors
Operations/Management › Navigation Safety
Issued 24 January 2002
Resolved
PROVIDE EXCERPTS OF COAST PILOT, LIGHT LIST AND NAVIGATION RULES. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Construction/Loadline
Issued 14 August 2001
Resolved
REPLACE 4 CRACKED PORTHOLES IN CABIN.
Construction/Loadline
Issued 14 August 2001
Resolved
FOUND CRACK IN RUDDER IN THE PINTEL AREA JUST ABOVE THE SKEG.
Construction/Loadline
Issued 5 February 2001
Resolved
INSTALL HIGH LEVEL BILGE ALARM IN ENGINE ROOM.
Engineering
Issued 5 February 2001
Resolved
INSTALL FLAME IMPENGEMENT BOWL ON FUEL STRAINER.
Lifesaving
Issued 5 February 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, REPLACE 406 MHZ EPIRB HYDROSTATIC RELEASE.
Documentation
Issued 31 January 2000
Resolved
MAKE APPROPRIATE CHANGES TO AND PROVIDE EVIDENCE OF ALIGNMENT OF OWNER ADDRESS ON BOTH THE CERTIFICATE OF INSPECTION AND THE CERTIFICATE OF DOCUMENTATION.
Fire Fighting
Issued 17 August 1999
Resolved
PROVE PROPER OPERATION OF FIXED FIRE FIGHTING EXTINGUISHING SYSTEM AT NEXT COAST GUARD INSPECTION.
Lifesaving
Issued 10 February 1999
Resolved
INSTALL 60' DARK FLOATING LINE ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Unknown
Issued 10 February 1999
Resolved
IMPLEMENT DRUG/ALCOHOL EMPLOYEE ASSISTANCE PROGRAM PER 46CFR16.401._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 10 February 1999
Resolved
INSTALL SMOKE DETECTOR IN BERTHING SPACES._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 10 February 1999
Resolved
LABEL VSL NAME AND CAPACITY ON LIFEFLOAT AND VSL NAME ON LIFEFLOAT PADDLES._x001C_ _x001C_ _x001C_
Lifesaving
Issued 10 February 1999
Resolved
INSTALL 100' PAINTER W/FLOAT FREE LINK ON LIFEFLOAT._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 10 February 1999
Resolved
INSTALL RETRO TAPE ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 13 February 1997
Resolved
PROVIDE MIS DRUG TESTING INFORMATION FORM
Lifesaving
Issued 13 February 1997
Resolved
PROVIDE CATEGORY 1, 406 MHZ EPIRB DESIGNED TO AUTOMATICALLY ACTIVATE AND FLOAT FREE. VESSEL'S ROUTE IS RESTRICTED TO NOT MORE THAN 3 MILES.
Fire Fighting
Issued 13 February 1997
Resolved
PROVIDE THREE (3) 2.5 GALLON FIRE BUCKETS.
Lifesaving
Issued 13 February 1997
Resolved
INSTALL REFLECTIVE MATERIAL ON RING BUOY.
Lifesaving
Issued 13 February 1997
Resolved
PROVIDE 406 MHZ EPIRB AND REPLACE LIFE FLOAT.
Unknown
Issued 18 January 1995
Resolved
Provide proof of drug tesing and membership in drug consortium.
Accommodation/Occupational Safety
Issued 18 January 1995
Resolved
Label forward emergency hatch "Emergency Escape Keep Clear".
Lifesaving
Issued 3 February 1994
Resolved
Restencil name of vessel & capacity on buoyant apparatus.
Lifesaving
Issued 3 February 1994
Resolved
Renew expired ornage smoke flares.
Lifesaving
Issued 21 February 1990
Resolved
PROVIDE 6 ADULT PFD'S. COMPLETE ABOVE PRIOR TO CARRYING MORE THAN 6 PASSENGERS WHEN CREW IS 2 OR 4 PASSENGERS WHEN CREW IS 4.
Documentation
Issued 9 January 1990
Resolved
CREDIT DRYDOCK DUE 10JUL91. PLEASE CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Deck/Cargo
Issued 9 January 1990
Resolved
AFT BILGE PUMP HOSE LOOSE ON O/B VALVE.
Construction/Loadline
Issued 9 January 1990
Resolved
STBD SHROUD STAY HAS WORN THREADS.
Deck/Cargo
Issued 9 January 1990
Resolved
MAIN MAST FDN PLT CORRODED AND FOAM ON STBD SIDE BROKE LOOSE.
Electrical
Issued 9 January 1990
Resolved
WIRE NUT SPLICES IN E/R.
Engineering
Issued 9 January 1990
Resolved
SHAFT LOG HOSE SOFT AND SPONGY.
Electrical
Issued 9 January 1990
Resolved
LOOSE CUT WIRES IN E/R.
Fire Fighting
Issued 14 March 1989
Resolved
INSTALL 2 ADDITIONAL B-II FIRE EXTINGUISHERS, TOTAL 3 ( 1- GALLEY, 2 AFT FOR ACCOM. & E/R.)
Fire Fighting
Issued 14 March 1989
Resolved
PROVIDE B-I FIRE EXTINGUISHER AT HELM.
Deck/Cargo
Issued 14 March 1989
Resolved
INSTALL MANUAL OVERRIDE SWITCH FOR 2 ELECT. BILGE PUMPS OR INSTALL A BILGE MAIN FOR THE FIXED HAND PUMP.
Lifesaving
Issued 14 March 1989
Resolved
PROVIDE WT CONTAINER FOR FLARES.
Documentation
Issued 14 March 1989
Resolved
POST EMERGENCY INSTRUCTIONS.
Documentation
Issued 14 March 1989
Resolved
PROVIDE VALID FCC RADIOTELEPHONY CERTIFICATE. ROUTE LIMITED TO 1000 FT. FROM SHORE UNTIL COMPLIED WITH.
Fire Fighting
Issued 14 March 1989
Resolved
REPLACE FIREPUMP HOSE AND PROVIDE SUCTION HOSE FOR PORTABLE PUMP.
Engineering
Issued 14 March 1989
Resolved
REPAIR FUEL SHUTOFF REMOTES.
Lifesaving
Issued 14 March 1989
Resolved
PROPERLY STENCIL AND INSTALL NEW NAMEPLATE ON BOUYANT APPARATUS AND COORECT ATTACHMENTS.
Engineering
Issued 14 March 1989
Resolved
RE-ATTACH MAIN ENGINE SEA STRAINER TO BULKHEAD.
Engineering
Issued 14 March 1989
Resolved
DOUBLE CLAMP GENERATOR SEA SUCTION HOSES AT STRAINER.
Navigation
Issued 14 March 1989
Resolved
REPLACE STBD. NAV. [name withheld].
Engineering
Issued 14 March 1989
Resolved
INSTALL HEAT SHIELD KIT FOR FUEL FILTER OR USCG ACCEPTABLE FUEL FILTER/
Engineering
Issued 14 March 1989
Resolved
REPLACE MAIN ENGINE SEA WATER OVERBOARD HOSE.
Accommodation/Occupational Safety
Issued 14 March 1989
Resolved
INSTALL 36" HIGH, 3 COURSE HAND RAILS ON WEATHER DECK.
Accommodation/Occupational Safety
Issued 14 March 1989
Resolved
REPAIR AFT PORT TOP RAIL PIN.
Documentation
Issued 11 January 1989
Resolved
NEXT DRYDOCK DUE 11JUL90.
Engineering
Issued 22 February 1988
Resolved
PROVIDE APPROVED FUEL LINE ON GENERATOR AND MAIN ENGINE.
Documentation
Issued 22 February 1988
Resolved
PROVIDE FCC CERTIFICATE AS EVIDENCE THAT THE INSTALLED RADIO IS IN COMPLIANCE WITH THEIR REGULATIONS.
Engineering
Issued 22 February 1988
Resolved
MAKE PERMANENT REPAIRS TO GENERATOR EXHAUST SYSTEM'S LEAK (DRY SYSTEM).
Ownership record