MAURY USCG vessel records Sign in
← All vessels

VERMILION

VERMILION is a 1977 fishing tender. The Coast Guard has recorded 65 inspections since 1985, most recently in July 2026, along with 56 deficiencies, 1 operational control and 7 casualty investigations between 2003 and 2025.

Records from 1985 to 2026. Most recent: inspection, 7 July 2026.

Built
1977
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7643679 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDJ9088
Flag
PANAMA
368022610
Maury page id
psix-49046

Inspections, by type

…with no type recorded24
Years with a record 28 calendar years (1985–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)166.3 ft × 40.0 ft × 14.0 ft
Registered tonnagegross 491 / net 333
ITC dimensions (L × B × D)166.3 ft × 40.0 ft × 14.0 ft
ITC tonnagegross 771 / net 257
BuilderHALTER MARINE SERVICES · MOSS POINT, MS, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portABBEVILLE, LA
Trade endorsementsFishery
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itFishing Tender
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it491 - Regulatory (Subpart C or D), Gross Ton
771 - Convention (Subpart B), Gross Ton
333 - Regulatory (Subpart C or D), Net Ton
257 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9088MMSI 368022610 · active · compulsorily equipped · granted 9 February 2018, expires 9 February 2028
WDC6637MMSI 367058853 · expired · compulsorily equipped · granted 10 July 2015, cancelled 30 August 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NS CHAMPION Tank Ship · MISLE 787970 · 23 March 2006 · activity 2675740

Inspection history · 65

7 July 2026 Type not recorded
No type recorded · USCGC SAWFISH (WPB 87357) · USCG Southeast District (CGD-SE) · Activity 8438085
17 June 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8161420
16 June 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8161857
10 July 2024 Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 7955836
25 June 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6987809
30 October 2018 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 6571792
16 July 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6483497
21 March 2018 Inclining Experiment · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6381456
5 October 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6022119
29 August 2014 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4968973
5 August 2011 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4106216
26 June 2008 Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3242688
21 May 2008 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3212926
24 May 2007 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2953279
22 June 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2689860
22 June 2006 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2729811
19 June 2006 Re-Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2710904
15 June 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2680339
23 March 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2675740
9 June 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2385006
14 February 2005 MTSA Verification · COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2292189
16 November 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2242248
10 November 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2242197
9 September 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2191443
9 June 2004 Annual Inspection · MTSA Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2093365
24 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1982911
13 June 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1818927
2 April 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1770531
3 March 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1759047
20 February 2003 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1745855
14 February 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1749509
5 February 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1749186
19 June 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1633874
18 June 2001 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1441894
20 March 2000 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1444322
15 February 2000 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1463561
9 June 1999 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1509913
26 March 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753894
21 March 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 108475
21 March 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 209772
20 December 1998 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1045712
17 November 1998 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1413444
10 April 1998 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1426083
30 March 1998 Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466509
5 January 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450116
20 December 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1094854
18 November 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1431715
28 February 1996 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1189520
7 February 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1405854
20 October 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 46690
20 December 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1407406
21 March 1994 Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1444813
20 January 1993 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1137906
10 August 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 936491
28 April 1992 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1267300
24 March 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 960892
21 March 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927533
5 March 1991 Excursion Permit
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1212233
28 February 1991 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 916840
5 February 1991 Inclining Experiment
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 905551
9 September 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1002836
20 April 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016452
24 February 1986 COI Inspection · Credit Drydock
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304161
16 November 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994773
26 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979342

Deficiency record · 56

Engineering › Freshwater System (cylinder head cooling) › Vent
Issued 5 August 2011 Resolved
Repair/Replace cooling water port on Port MDE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2011
Resolution: Item repaired
Electrical › Electric Generation Source (service) › Generator
Issued 5 August 2011 Resolved
Repair hunting governor on STBD generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2011
Resolution: item repaired.
Fire Fighting › Fire Hoses › Condition
Issued 5 August 2011 Resolved
Hydrotest fire hoses to 100psi IAW 46CFR 91.25-20(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 12 August 2011
Resolution: Test completed
Lifesaving › Inflatable Liferafts › Lamp (outside)
Issued 5 August 2011 Resolved
Repair Emergency lights for life raft embarkation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 12 August 2011
Resolution: Item repaired
Construction/Loadline › Structures › Manhole
Issued 26 June 2008 Resolved
Gasket on main deck water/ballast tank manhole cover wasted
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 June 2008
Resolution: Installed new gasket
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 June 2008 Resolved
Electrical panels/circuit breaker board not labeled correctly
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 July 2008
Resolution: labeled properly
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 26 June 2008 Resolved
Passenger toilet inoperative
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 27 June 2008
Resolution: repaired toilet
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 26 June 2008 Resolved
Install metal garbage cans in galley
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 27 June 2008
Resolution: Metal garbage can installed
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 26 June 2008 Resolved
Refrigerator/washer/dryer not secured for sea.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 27 June 2008
Resolution: Secured with straps and metal brackets
Fire Fighting › Fire Hoses › Condition
Issued 26 June 2008 Resolved
01 fire hose had pin hole leak.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 27 June 2008
Resolution: replaced fire hose
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 24 May 2007 Resolved
Provide copy of Navigation Rules on Bridge.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 12 July 2007
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 24 May 2007 Resolved
Repair depth sounding device.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 12 July 2007
Deck/Cargo › Mooring/Anchoring › Winch
Issued 24 May 2007 Resolved
Repair port anchor windlass.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 12 July 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 May 2007 Resolved
Provide battery box for alarm backup battery.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 12 July 2007
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 24 May 2007 Resolved
Renew flame screen on hydraulic vent.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 12 July 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 24 May 2007 Resolved
Paint starboard aft draft marks and deck line contrasting color to the hull.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 12 July 2007
Fire Fighting › Fire Main › Condition
Issued 22 June 2006 Resolved
Damaged due to fire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 22 June 2006 Resolved
Probable cause of fire.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Replaced all fuel lines with double jacketed high pressure lines.
Electrical › Electric Supply System (service) › Cable
Issued 22 June 2006 Resolved
Damaged due to fire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Construction/Loadline › Structures › Deck Plating
Issued 22 June 2006 Resolved
Damaged due to fire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 19 June 2006 Resolved
Renew or prove proper operation of the overspeed trip for the aft (#2) generator prime mover
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2006
Resolution: New trip installed and tested.
Construction/Loadline › Penetrations › Gasket
Issued 19 June 2006 Resolved
Provide proper (closed cell) rubber gasket material for all watertight doors below the main deck.
Condition: Improper/Lack of Maintenance
Due 31 August 2006
Resolved 18 July 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 19 June 2006 Resolved
Provide operable engine tachometer at the operating station for hte port engine tachometer
Condition: Unknown
Due 30 June 2006
Resolved 30 June 2006
Communications › Radio Communications › EPIRB
Issued 19 June 2006 Resolved
Provide proof of current EPIRB registration prior to operating beyond 20 NM from baseline.
Condition: Improper/Lack of Maintenance
Due 19 June 2006
Resolved 19 June 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 June 2006 Resolved
Provide bilge alarms for the steering room and the bow thruster space.
Condition: Unknown
Due 30 July 2006
Resolved 18 July 2006
Operations/Management › Drills/Instruction › Fire
Issued 14 February 2005 Resolved
Prior to 9 April, make vessel & crew available for fire and man overboard drills in the presence of and satisfaction to attending Coast Guard inspector.
Due 9 April 2005
Resolved 19 June 2006
Engineering › Generator (propulsion/auxiliary-electric)
Issued 19 June 2002 Resolved
Prove proper operation of the #1 and #2 SSG overspeed shutdowns.
Condition: Unknown
Due 1 July 2002
Resolved 15 November 2002
Resolution: Received report.
Communications › Radio Communications
Issued 19 June 2002 Resolved
Provide documentation of the proper operation of the SSB radio. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Due 1 July 2002
Resolved 15 November 2002
Resolution: Received report.
Unknown
Issued 20 March 2000 Resolved
Prove proper operation of port generator overspeed.
Condition: Unknown
Due 10 May 2000
Resolved 11 May 2000
Unknown
Issued 20 March 2000 Resolved
Install adequate rescue platform and conduct man overboard drill.
Condition: Unknown
Due 10 May 2000
Resolved 11 May 2000
Unknown
Issued 20 March 2000 Resolved
Renew/repair starboard side steering ram.
Condition: Unknown
Due 10 May 2000
Resolved 11 May 2000
Fire Fighting
Issued 17 November 1998 Resolved
SMOKE DETECTORS THROUGH-OUT CREW SPACES
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Engineering
Issued 17 November 1998 Resolved
INSTALL FLAME SHIELDS ON BOTH MDE RACOR FUEL SEPERATORS
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Lifesaving
Issued 17 November 1998 Resolved
PROVE PROPER OPERATION OF RESCUE BOAT MOTOR, INSURE ADJ FOR PROPER STARTING_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Lifesaving
Issued 17 November 1998 Resolved
FREE BOTH EGRESS LIGHTS FOR PROPER POSITION^
Condition: Unknown
Due 17 November 1998
Resolved 20 November 1998
Unknown
Issued 17 November 1998 Resolved
COMPLETE DAPI FORM A, VIA COMPANY REP. AUDIT, RETURN TO LOCAL OCMI FOR REVIEW.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Construction/Loadline
Issued 10 April 1998 Resolved
Vessel shall not operate as a U.S. Coast Guard Certificated vessel until Credit Drydock has been completed to the satification of cognizant OCMI Marine Inspector.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Electrical
Issued 18 November 1996 Resolved
Provide beltguard for both air compressors.
Condition: Unknown
Due 18 December 1996
Resolved 20 December 1996
Electrical
Issued 18 November 1996 Resolved
Provide Emergency lighting for both engine room escape ladders.
Condition: Unknown
Due 18 December 1996
Resolved 20 December 1996
Lifesaving
Issued 18 November 1996 Resolved
Prior to getting u/w provide onboard properly installed inflatable liferafts to accomodate all personnel aboard.
Condition: Unknown
Due 18 December 1996
Resolved 20 December 1996
Lifesaving
Issued 18 November 1996 Resolved
Prior to getting u/w provide onboard sufficient distress signals as required by 46CFR94.90-5
Condition: Unknown
Due 18 December 1996
Resolved 20 December 1996
Navigation
Issued 18 November 1996 Resolved
Prove proper operation of steering pump power failure alarm panel in pilothouse.
Condition: Unknown
Due 18 December 1996
Resolved 20 December 1996
Electrical
Issued 18 November 1996 Resolved
Remove "deadended" electrical cables from beneath fore and aft steering consoles in pilothouse.
Condition: Unknown
Due 18 December 1996
Resolved 20 December 1996
Engineering
Issued 18 November 1996 Resolved
Provide detailed Automation Test Procedures for Approval.
Condition: Unknown
Due 18 December 1996
Resolved 20 December 1996
Electrical
Issued 18 November 1996 Resolved
Prove operation of low air pressure alarm.
Condition: Unknown
Due 18 December 1996
Resolved 20 December 1996
Engineering
Issued 20 April 1987 Resolved
PROVIDE PROPER OPERATION OF PILOT HOUSE HIGH BILGE LEVEL ALARM BY NEXT DRY-DOCKING, BUT NOT LATER THAN 24 FEBRUARY 1988 OR REPLACE PRESENT UNIT.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Navigation
Issued 20 April 1987 Resolved
PROVIDE DEVIATION TABLE FOR MAGNETIC COMPASS.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Lifesaving
Issued 20 April 1987 Resolved
PROVIDE TWO COAST GUARD APPROVED AND SERVICED LIFERAFTS AND PROVIDE THE PROPER FLOAT FREE CRADLE FOR EACH RAFT. IF THE USCG APPROVED AND SERVICED LIFERAFTS ARE NOT ON BOARD THE VESSEL BY 20 MAY 1987, THE MASTER WILL NOT OPERATE THE VESSEL UNTIL THE LIFERAFTS ARE INSTALLED.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Navigation
Issued 20 April 1987 Resolved
PROVIDE PROPER OPERATION OF ALL NAVIGATION LIGHTS AND FAULT ALARMS.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Navigation
Issued 20 April 1987 Resolved
PROVE PROPER OPERATION OF SHIP'S TELEPHONE LOCATED AT THE AFT PILOT HOUSE STEERING STATION.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Engineering
Issued 20 April 1987 Resolved
PROVIDE 30 X 30 MESH SCREENS FOR ALL FUEL TANK VENTS.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Electrical
Issued 20 April 1987 Resolved
PROVIDE PROPER MARINE TYPE MOTOR CONTROLLER FOR ANCHOR WINDLASS OR RELOCATECONTROLLER.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Lifesaving
Issued 24 February 1986 Resolved
PROVIDE 12 U.S. COAST GUARD APPROVED HAND HELD PARACHUTE RED FLARE DISTRESSSIGNALS.
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986
Engineering
Issued 24 February 1986 Resolved
PROVE PROPER OPERATION OF PART MAIN ENGINE OVERSPEED TRIP.
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986
Lifesaving
Issued 24 February 1986 Resolved
PERFORM SERVICING ON EXPIRED INFLATABLE LIFERAFT IN PRESENT OF A U.S. COASTGUARD MARINE INSPECTOR OR PROVIDE 1-15 MAN U.S. COAST GUARD APPROVED LIFE- RAFT WITH UP TO DATE SERVICING.
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986
Engineering
Issued 24 February 1986 Resolved
PROVE PROPER OPERATION OF ENGINE ROOM ALARM PANEL.
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986

Casualty record · 7

5 February 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1749186
14 February 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1749509
3 March 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1759047
2 April 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1770531
22 June 2006Routine · role: Involved in a Marine Casualty · activity 2689860
28 November 2011Routine · role: Involved in a Marine Casualty · activity 4198729
16 June 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8161857
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SPT PROTECTOR (2003–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.