Records from 2006 to 2019. Most recent: inspection, 15 April 2019.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 August 2018
Resolved
At each inspection, lifesaving equipment shall be inspected to determine its serviceability. Found 12 adult lifejackets in need of repair, to include retroreflective tape and markings.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 August 2018
Resolved 13 August 2018
Resolution: Corrected prior to completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 August 2018
Resolved
All vessels shall carry pyrotechnic distress signals. Found 08 of 12 red hand flares expired and remaining 04 flares will expire in 02 months.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 13 August 2018
Resolved 13 August 2018
Resolution: Corrected prior to completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 August 2018
Resolved
At each insepction, lifesaving equipment shall be inspected to determine its serviceability. Retroreflective tape on the ring buoy is deteriorated and the battery in the floating light is expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 August 2018
Resolved 13 August 2018
Resolution: Corrected prior to completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 August 2018
Resolved
At each inspection, lifesaving equipment shall be inspected to determine its serviceability. Found all four lifefloats with expired batteries in the floating waterlights, and paddles with incorrect vessel name, and some deteriorated retro
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2018
Resolved 20 September 2018
Resolution: Verified items are corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 August 2018
Resolved
Each lifefloat shall be conspicuously marked with the number of persons allowed on each lifefloat. Found two lifefloats marked for an incorrect number of persons. The two lifefloats are rated for 11 persons, but one is marked for 12 persons and one is marked for 15 persons.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2018
Resolved 20 September 2018
Resolution: Verified both lifefloats are now correctly marked for 11 persons.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 13 August 2018
Resolved
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 August 2018
Resolved 13 August 2018
Resolution: Upper deck was correctly marked prior to completion of inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 August 2018
Resolved
Vessels required to be fitted with radio installations shall comply with the regulations of the federal communications commission. Both the FCC radio station authorization certificate and teh FCC safety radio telephone certificate bear the wrong vessel name.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2018
Resolved 20 September 2018
Resolution: Updated certificates are provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 August 2018
Resolved
A durable placard must be posted next to all radio telephone installations with emergency broadcast instructions and information specific to the vessel. Current placard does not have the correct vessel name.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2018
Resolved 20 September 2018
Resolution: Broadcast placard is up to date.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 August 2018
Resolved
Guards or protective devices shall be provided in all hazardous places. Found no guards fitted over stbd main engine pto pump and alternator, and none fitted over stbd generator belts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2018
Resolved 15 April 2019
Resolution: Vessel was sold foreign and no longer active in United States.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 August 2018
Resolved
At each inspection generators shall be examined and tested to determine fitness for service. Stbd generator could not be tested to determine fitness for service.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2018
Resolved 20 September 2018
Resolution: Verified operation of stbd generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 August 2018
Resolved
All electrical panels shall be protected by dripproof protection. Panel at control station is missing blanks (protective inserts).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2018
Resolved 15 April 2019
Resolution: Vessel was sold foreign and no longer active in United States.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 May 2018
Resolved
All watertight closures in decks shall be examined for operation and condition. Three of four deck hatches have fractures in framing. Make proper repairs or renew hatches. 46 CFR 176.25-5
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 13 August 2018
Resolution: Verified three new watertight deck hatches installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 May 2018
Resolved
Populsion machinery exhaust shall be gastight throughout its length. An approx. 6 inch crack is present in teh port engine exhaust where cooling water is injected. Make permanent repairs as discussed; drill stop & weld. 46 CFR 182.20-20
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2018
Resolved 5 June 2018
Resolution: Verified proper repair has been made.
Engineering › Bilge Water Management System › Valve
Issued 17 August 2017
Resolved
Each bilge suction line shall be provided with a stop valve at the control manifold. Provide a permanent means for operating the bilge manifold valve for the passenger compartment.
Condition: Improper/Lack of Maintenance
Due 17 September 2017
Resolved 31 October 2017
Resolution: New valve and handle installed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 August 2017
Resolved
An audible alarm shall be provided at the operation station to indicate high water.
Due 24 September 2017
Resolved 31 October 2017
Resolution: Audible alarm was replaced and operating correctly.
Lifesaving › Lifefloat › Not on Board
Issued 18 May 2016
Resolved
Provide lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Resolution: Operator installed lifefloats.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 18 May 2016
Resolved
Provide lights for ALL life jackets.Vessel restricted to LBS plus limited coastwise route.
Action required: 705 - Other - as specified
Resolved 17 August 2017
Resolution: Amended COI to LBS and limited coast wise.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 18 May 2016
Resolved
Provide single side-band radio. Restricted to LBS plus limited coastwise route.
Action required: 705 - Other - as specified
Resolved 17 August 2017
Resolution: Amended COI to Lakes Bays and Sounds and limited Coastwise.
Engineering › Bilge Water Management System › Not Operational
Issued 18 May 2016
Resolved
Repair bilge pump/piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Resolution: Operator repaired bilge pumping system. Tested SAT.