Records from 1999 to 2012. Most recent: inspection, 23 January 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
23 January 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4218442
14 December 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3910688
1 December 2009
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3642137
10 November 2008
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3361450
23 October 2008
Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3349389
21 October 2006
ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2806615
20 March 2006
PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2629220
13 October 2005
Type not recorded
No type recorded · USCGC SEAHAWK (WPB 87323) · USCG Southeast District (CGD-SE) · Activity 2513978
12 September 2005
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2490270
27 February 2005
ISPS III Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2299768
2 July 2004
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2117856
20 February 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2012791
24 January 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1734882
3 April 2002
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1600614
15 March 2002
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1494613
3 October 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294270
30 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 276376
8 March 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 426258
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 23 January 2012
Resolved
Chief mate does not possess a valid flag state endorsement, nor a current application on file. Company switched manning companies and had not obtained Chief officer's current flag state endorsement. STCW 95 I/4.1.1 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2012
Resolution: Received flag state endorsement.
Operations/Management › Drills/Instruction › Fire
Issued 1 December 2009
Resolved
Crew failed abandon ship, fire and man overboard drills
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2009
Resolved 4 December 2009
Resolution: Demonstrated satisfactory drills.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 October 2008
Resolved
OWS automatic stopping device is not alarming and stopping with content over 15 ppm. Class must attest to proper operation of OWS nlt 23NOV08.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 10 November 2008
Resolution: Received Class report attesting to the proper repair and operation of the OWS.
Pollution Prevention/Response › Prevention Equipment
Issued 15 March 2002
Resolved
Unable to demonstrate operation of the OWS oil content monitor. Vessel prohibited from using OWS until proper operation is demonstrated. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 2 April 2002
Resolution: Received faxed copy of class report stating repairs have been made to the OWS.
Navigation
Issued 8 March 1999
Resolved
VSL DOES NOT HAVE ADEQUATE PUBS FOR US WATERS OF ITS INTENDED VOYAGE. US NAVIGATION RULES AND 33 CODE OF FEDERAL REGULATIONS PARTS 125 - 199 NOT PRESENT. NO INTERNATIONAL EQUIVALENT ON BOARD VESSEL.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000