Inspection history · 53
29 April 2026
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8340760
24 February 2026
Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8321165
11 February 2026
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8310230
7 May 2025
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8121280
11 July 2024
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7929345
15 May 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7918471
26 April 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7675472
13 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576970
6 July 2022
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7497174
14 May 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7450418
16 February 2022
DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7396689
11 May 2021
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7193244
26 June 2020
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6987656
8 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6950200
22 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6689370
10 July 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6469093
19 April 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6394223
17 February 2017
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6100430
11 August 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5940424
8 June 2016
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5872321
10 June 2015
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5128792
20 August 2014
Deficiency Check · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4948040
10 June 2014
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4872700
18 June 2013
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4619929
21 August 2012
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4411110
3 May 2012
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4304094
20 March 2012
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4248908
6 December 2011
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4202973
14 June 2011
Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4036998
17 August 2010
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3819110
18 June 2010
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3763165
2 June 2010
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3756421
17 June 2009
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3494910
18 September 2008
Annual Inspection · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3320088
23 April 2008
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3179265
20 March 2007
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2890455
28 June 2006
Deficiency Check · Administrative Inspection · Annual Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2689371
28 June 2005
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2425434
28 October 2004
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2229853
9 June 2004
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2093225
17 March 2003
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1759933
4 March 2003
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1752326
14 January 2003
Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1729613
21 March 2002
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1495643
22 August 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1071647
14 August 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1384850
20 March 2001
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1403355
6 September 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1054249
29 March 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1467671
22 March 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1097502
22 March 1999
Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446791
1 February 1999
Initial Construction-Excluding Oversight · Deadweight Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378587
12 January 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1420070
Construction/Loadline › Hull › Hull Plating
Issued 11 August 2016
Resolved
Crop and renew plate at starboard rake end, from head log to turn of the bilge over to first weld seam to port, approx 5'x8'.
Action required: 705 - Other - as specified
Resolved 23 September 2016
Resolution: Witnessed safisfactory airtest of welded insert.
Construction/Loadline › Hull › Weld
Issued 11 August 2016
Resolved
Repair 02 cracked welds in void #2 at deck longitudinals.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Examined repair welds.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 August 2016
Resolved
Re-paint draft marks and name of vessel.
Action required: 705 - Other - as specified
Resolved 1 November 2016
Resolution: Draft marks and vessel repainted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 August 2016
Resolved
Repair fence railing on starboard bow.
Action required: 705 - Other - as specified
Resolved 1 November 2016
Resolution: Fencing repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 11 August 2016
Resolved
Gauge bottom plate in way of all hatch covers and make readings available to the Coast Guard, written report not required.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Examined welds, witnessed air test of bottom plate inserts in #1,2,3, &4 voids.
Construction/Loadline › Hull › Weld
Issued 11 August 2016
Resolved
Repair cracked welds on vehicle ramp.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Examined repaire welds.
Construction/Loadline › Hull › Weld
Issued 11 August 2016
Resolved
Provide mill cert. for steel used in bow/bottom shell repairs.
Action required: 705 - Other - as specified
Resolved 26 August 2016
Resolution: Mill cert and filler metal cert provided.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 June 2015
Resolved
Vessel's anti-slip coating has worn creating a slipping hazard on barge deck through normal wear and tear. Provide plan for installation of new coating system. 46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 12 August 2015
Resolution: Completed installation of non-skid on main deck of barge and loading ramp.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 June 2015
Resolved
Vessel has required amount of child sized life jackets that are reversible with labeling only on one side. Label both sides or the outer edge. 46 CFR 185.604(g)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 June 2015
Resolved 18 June 2015
Resolution: Verified that life jackets were labled properly.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 June 2015
Resolved
Vessel had the required amount of lifebuoys onboard the vessel. Lifebuoys were missing approval placards on all three. Replace lifebuoys with proper placarding. 46 CFR 180.70(b)(1)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 June 2015
Resolved 18 June 2015
Resolution: Vessel replaced all three lifebuoys with new ones.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 20 August 2014
Resolved
Witnessed multiple pickups in the overhead along the longitudinal bulkhead thoughout the barge.
Action required: 705 - Other - as specified
Resolved 15 October 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 August 2014
Resolved
Deck rail on the starboard quarter has a minor bend in the rail. Chain link fencing needs to be repaired or replaced.
Action required: 705 - Other - as specified
Resolved 15 October 2014
Resolution: Entire deck rail and fence replaced with new.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 20 March 2012
Resolved
Conduct EAP training and document properly IAW 46 CFR part 16.
Due 3 April 2012
Resolved 3 May 2012
Fire Fighting › Fire Pumps › Power Source
Issued 14 June 2011
Resolved
Make permanent repairs to both fire pumps. Port pump had a patch on the pump housing and the stbd would not take suction. IAW 46 CFR 181.300.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2011
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 June 2011
Resolved
The passenger count is reduced to 43 and 2 crew until 2 adult lifejackets are provided onboard IAW 46 CFR 180.71 (a).
Action required: 705 - Other - as specified
Resolved 16 June 2011
Lifesaving › Lifebuoys › Serviceable
Issued 14 June 2011
Resolved
Replace stbd ring lifebuoy due to broken grab line IAW 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2011
Documentation › Logs/Records › Logbook (official)
Issued 28 June 2006
Resolved
Provide current training log book with description of training.
Due 28 July 2006
Resolved 26 July 2006
Construction/Loadline › Hull › Weld
Issued 28 June 2006
Resolved
Provide repair proposal for crack in forward rake on stbd side. After proposal is approval make repairs. Hourly rounds are to be make on compartment.
Due 30 August 2006
Resolved 12 October 2006
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 June 2006
Resolved
Replace retrorefletive tape on one adult life jacket.
Due 28 July 2006
Resolved 26 July 2006
Construction/Loadline › Hull › Bottom Plating
Issued 28 October 2004
Resolved
Provide gauging in areas identified by inspector.
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 3 November 2004
Resolution: Area gauged and found to be SAT
Construction/Loadline › Hull › Bottom Plating
Issued 28 October 2004
Resolved
Provide original scantling measurement
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 3 November 2004
Operations/Management › Drug and Alcohol Testing
Issued 4 March 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 15 March 2003
Resolved 17 March 2003
Construction/Loadline › Structures
Issued 4 March 2003
Resolved
PROVIDE LARGER SHACKLE FOR PORT TUG CONNECTION POINT
Action required: 705 - Other - as specified
Due 15 March 2003
Resolved 17 March 2003
Lifesaving › Lifebuoys
Issued 4 March 2003
Resolved
REPAIR OR REPLACE FLOAT LIGHT BRACKET FOR LIFERING LEGACY COMPONENT DESC: Stowage
Action required: 705 - Other - as specified
Due 15 March 2003
Resolved 17 March 2003
Construction/Loadline › Structures
Issued 14 January 2003
Resolved
RENEW ALL BOW RAMP HINGE PINS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2003
Resolved 30 January 2003
Construction/Loadline
Issued 14 August 2001
Resolved
REWELD THREE (3) FRAMES IN FORPEAK.
Condition: Unknown
Due 14 September 2001
Resolved 22 August 2001
Accommodation/Occupational Safety
Issued 29 March 2000
Resolved
REPLACE PLASTIC WASTE RECEPTICLES WITH NON-FLAMABLE TYPE.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Lifesaving
Issued 29 March 2000
Resolved
INSTALL 3-6 FOOT LINE ON RING BUOY LIGHT.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Lifesaving
Issued 29 March 2000
Resolved
PROVIDE PROCEDURE FOR CONDUCTING PASSENGER COUNT AND PASSENGER ORIENTATION.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Fire Fighting
Issued 29 March 2000
Resolved
SERVICE AFT BII PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Fire Fighting
Issued 29 March 2000
Resolved
REPLACE BRASS SOLID STREAM FIRE HOSE NOZZLES WITH ADJUSTABLE TYPE.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Deck/Cargo
Issued 12 January 1999
Resolved
PRIOR TO PLACING THE VESSEL IN SERVICE ON IT'S INTENDED ROUTE, PERFORM AN OPERATIONAL TEST OF THE ANCHORING SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999