Inspection history · 25
20 April 2026
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8352950
25 July 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8183410
18 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8190397
10 July 2024
COI Inspection · Administrative Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7948038
5 June 2024
Damage Survey · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7929313
5 June 2024
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7931682
24 April 2024
Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7912319
11 July 2023
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7739445
21 July 2022
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7504561
3 November 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7344944
29 July 2021
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7249123
13 July 2021
Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7254667
10 September 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7055772
29 July 2020
MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7001384
27 May 2020
Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6962005
29 July 2019
DAPI Audit · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6758389
16 July 2019
Drydock Exam · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7029288
28 June 2019
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6728428
18 July 2018
MTSA/ISPS Verification · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6472768
29 June 2018
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6459523
27 October 2017
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6296616
3 October 2017
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6296614
12 July 2017
MTSA/ISPS Verification · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6206293
15 July 2016
COI Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5917736
7 June 2016
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5898736
14 - Pollution Prevention › 143 - MARPOL Annex III › Other (MARPOL Annex III)
Issued 20 April 2026
No resolution recorded
Key personnel must complete training in 33CFR101.650(d)(2) by January 12, 2026.
Company does not have a CYSO and all key personnel have not yet completed the training as of this inspection.
33 CFR 101.650(d)(4)
705: 60 days
Action required: 705 - Other - as specified
Due 4 May 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 July 2025
Resolved
Aft lifebuoy taken out of service by marine inspector due to black staining and weathered material. Replace with new.
46 CFR 180.70
Action required: 10 - Deficiency Rectified
Due 28 July 2025
Resolved 25 July 2025
Resolution: Operator replaced with new lifebuoy verified by Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 July 2025
Resolved
Aft firehose station inside the main deck passenger accomodation space handle is wasted. Replace with new.
46 CFR 181.310
Action required: 10 - Deficiency Rectified
Resolved 25 July 2025
Resolution: Operator replaced the entire valve, stem and handle with new.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 10 July 2024
Resolved
At each initial and subsequent reinspection for certification the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. The main and auxiliary steering apparatus shall be tested by operation and the inspector shall examine the mechanism thereof throughout its length. Assistant steering rod corroded. Descale for reinspection or replace rod in-kind.
46 CFR 176.25-35
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2024
Resolution: Verified assistant steering rod replaced with new stainless 316 pipe. Verified movement/actuation of all components satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 July 2024
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended: Electrical cable. The cable shall be examined as far as practicable without under disturbance of the cable or electrical apparatus. Wiring under the operating station has dead end wiring, unsupported wiring. Secure wiring IAW 46 CFR 183.
46 CFR 176.25-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2024
Resolution: Verified satisfactory connections, supported wiring and secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2024
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the
following items to the extent necessary to determine that they are in proper operating condition and fit for
the service for which they are intended: all generators shall be checked. Replace missing STBD generator mounting bolts.
46 CFR 176.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 July 2025
Resolution: Verified all mounting fasteners installed on STBD gen motor mount during MISLE DD activity 8183185 on 08July2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 June 2024
Resolved
Starboard generator exhaust clamp is corroded. Descale corrosion for reinspection or replace the exhuast clamp back to original.
Action required: 705 - Other - as specified
Due 31 July 2024
Resolved 8 July 2025
Resolution: Cleared this deficiency from DD activity 8183185 on 08July2025. New exhaust clamp installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024
Resolved
Wire bundling along starboard bulkhead of void #2 is not supported by metal supports every 24" as required.
Action required: 705 - Other - as specified
Due 31 July 2024
Resolved 18 June 2024
Resolution: Verified wire supports installed in #2 void.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 July 2023
Resolved
A leak was discovered in the firemain piping in the compartment forward of the engine room at the threaded portion of the pipe where it crossed through the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2023
Resolved 31 July 2023
Resolution: Repair was completed by Subbase Drydock during the inspection, while in attendance by the marine inspector. Fire pump and firemain tested, and performed satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2021
Resolved
Replace wasted starboard main engine reduction gear cooling water discharge hose.
Action required: 705 - Other - as specified
Due 3 November 2021
Resolved 3 December 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 October 2020
Resolved
Provide metal supports every 24" installed to avoid chafing for all overhead cables below deck in all spaces including lower passenger space voids.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 29 July 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 22 October 2020
Resolved
Provide means to prevent water ingress to port bow ventilation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 29 July 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 October 2020
Resolved
Make electrical panel watertight located above pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 29 July 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 22 October 2020
Resolved
ISM non-conformities are not being documented using the correct non-comformity reporting sheet from the vessel safety management system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 29 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2020
Resolved
Starting batteries for main engine are at end life and out of service. Replace batteries in-kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2020
Resolved 22 October 2020
Resolution: Batteries replaced and observed satisfactory operational battery start of main engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 October 2020
Resolved
Provide battery disconnect switches between #1 and #2 generator starting batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2020
Resolved 22 October 2020
Resolution: Battery switches installed at #1 and #2 generators.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 October 2020
Resolved
Firemain piping under deck of starboard fire station had significant pressurized leak during electric fire pump operational test. Make proper repairs to firemain piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2020
Resolved 22 October 2020
Resolution: Firemain piping cropped and renewed. Operational test of firemain conducted and no water leak observed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 October 2020
Resolved
Permanent affix stern room bilge alarm light to bilge alarm panel and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2020
Resolved 22 October 2020
Resolution: Stern room bilge light tested sat and light permanently affixed to alarm panel on bridge.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 14 October 2020
Resolved
Provide updated senior deckhand crewlist.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2020
Resolved 22 October 2020
Resolution: Senior deckhand crewlist updated.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 October 2020
Resolved
Provide valid FCC Safety Radio Telephony Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2020
Resolved 22 October 2020
Resolution: FCC Safety Radio Telephony Certificate verified.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 14 October 2020
Resolved
Provide valid COD or VI registration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 22 October 2020
Resolution: Current VI registration verified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2020
Resolved
Port forward waterlight inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2020
Resolved 22 October 2020
Resolution: Port forward waterlight tested satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 May 2020
Resolved
Per MSIB 0920 and due to COVID-19, the vessel is granted a 90 day drydock extension to be conducted no later than 31OCT20. Vessel is not in operations at the moment and will require the drydock inspection prior to carrying passengers.
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 10 September 2020
Resolution: Completed satisfactory USCG DD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2018
Resolved
Replace holed cooling piping on starboard main diesel engine turbos.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Turbo lines replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 July 2018
Resolved
Remove excess wire terminals on reserve battery in way of wheel house.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Wires directed to a bus bar.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 July 2018
Resolved
Prove proper operation of high bilge alarm for main cabin bilge area.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: High bilge alarm repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 October 2017
Resolved
Repair fwd bow rails and stbd cabin window.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 October 2017
Resolved 27 October 2017
Resolution: Repaired satisfactorily.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 October 2017
Resolved
Repair rail stanchions aft stbd side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 October 2017
Resolved 27 October 2017
Resolution: Repaired satisfactorily.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 July 2016
Resolved
secure loose wiring below MDE monitoring guages
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 19 July 2016
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 15 July 2016
Resolved
Prove proper operation of AIS
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 19 July 2016