SPIRIT OF PENNEKAMP

SPIRIT OF PENNEKAMP is a 1999 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1999, most recently in October 2025, along with 64 deficiencies and 3 casualty investigations between 2003 and 2015.

Records from 1999 to 2025. Most recent: inspection, 22 October 2025.

Built
1999
Last inspected
22 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY8979
490702
Flag
UNITED STATES
367388390
Maury page id
psix-490702

Inspections, by type

…with no type recorded6
Years with a record 24 calendar years (1999–2025)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.2 ft × 28.2 ft × 6.8 ft
Registered tonnagegross 51 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROS ENT INC · LOREAUVILLE LA, UNITED STATES · built 1999
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Simplified, Gross Ton
41 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY8979MMSI 367388390 · active · compulsorily equipped · granted 13 February 2019, expires 23 February 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 48

22 October 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8239808
26 November 2024 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8038100
29 October 2024 Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8038605
4 October 2023 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7803156
17 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7668502
11 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7410230
22 October 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7356063
8 June 2021 DAPI Audit · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7220225
11 June 2020 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6974744
1 October 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6821425
10 July 2019 Administrative Inspection · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6744870
9 July 2018 Annual Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6473406
6 December 2017 Administrative Inspection · Internal Structural Exam · Hull Examination · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6538814
11 April 2017 DAPI Audit · Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6121640
2 February 2017 Deadweight Survey · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6214004
18 October 2016 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6024903
19 April 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5856930
3 June 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4881682
6 September 2011 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4137383
5 August 2011 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4105788
14 July 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4080315
3 January 2011 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3919309
26 October 2010 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3877749
27 April 2009 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3461944
3 October 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3337715
15 April 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3184425
14 September 2007 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3130028
25 April 2007 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2914634
12 September 2006 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2779112
24 April 2006 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2632443
18 April 2005 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2326321
4 January 2005 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2269061
23 September 2004 Drydock Extension
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2203270
28 April 2004 Annual Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2054617
28 July 2003 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1890088
30 April 2003 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1769774
10 September 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1675174
26 April 2002 MARPOL Annex V Examination · COI Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1599749
8 May 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1453888
9 September 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1373158
25 April 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1381876
5 February 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 104602
5 February 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 217565
25 October 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1127278
31 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1120969
10 August 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1112254
11 May 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885385
27 April 1999 Hull Examination · Initial Construction-Excluding Oversight · Deadweight Survey · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466603

Deficiency record · 64

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 October 2025 Resolved
01 life jacket needs to be replaced. Passenger count is lowered by 01 passenger until life jacket is on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 October 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 October 2025 Resolved
Fix Stern light. Vessel restricted to day time operations until stern light is fixed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 October 2025 Resolved
Life floats need SOLAS retro tape renewed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2025
Resolved 22 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 November 2024 Resolved
A vessel of more than 26 feet in length, but not more than 65 feet must carry a minimum of one life buoy of not less than 24 inches in diameter. Replace dilapidated ring buoy.
Action required: 66 - Prior to drilling or production operations
Resolved 26 November 2024
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 26 November 2024 Resolved
A vessel with more than one passenger deck must have the public address system operable from the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2024
Resolved 26 December 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 November 2024 Resolved
EPIRB is missing its reg. sticker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2024
Resolved 26 December 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 April 2022 Resolved
Throw line for life ring is dry rotted and fraying apart. Must replace 60 foot grab line with CG approved line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 21 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 June 2021 Resolved
Both fire nozzles are corroded and won't allow to be switched from stream to spray pattern. Must make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2021
Resolved 21 July 2021
Resolution: Replaced both fire nozzles, test SAT
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 June 2021 Resolved
Fire pump is leaking with a steady stream coming from around the shaft. Must make repairs and test the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2021
Resolved 15 July 2021
Resolution: Vessel replaced pump and motor, test SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 June 2021 Resolved
Pressure gauge on discharge side of fire pump is not working and can not read any pressure. Must make repairs and test the the satisfaction on attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2021
Resolved 15 July 2021
Resolution: New gauge, pump and motor. Test SAT
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 June 2021 Resolved
Anchor light is not bright enough to meet the distance requirements. Must make repairs and test to the satisfaction of attending CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2021
Resolved 21 July 2021
Resolution: Replaced lens and bulb, test SAT
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 June 2021 Resolved
NAV chart has a print date of 2014, but zero chart corrections were made. Must update chart with all corrections published since print date or buy new CG approve NAV chart.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 25 August 2021
Resolution: Bought new CG approved paper NAV Chart with print date of May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 June 2020 Resolved
Life ring on top deck has wasted grab line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 July 2020
Resolution: Life ring grab line was renewed and verified.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 June 2020 Resolved
Update charts, either paper or chart plotter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2020
Resolution: Vessel updated all paper charts.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2019 Resolved
Fwd fire station hose is damaged. Renew hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2019
Resolution: Forward fire hose was replaced with a new one.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2019 Resolved
Fwd fire station must have spanner wrench. Provide.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2019
Resolution: New spanner wrench was purchased and installed.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 10 July 2019 Resolved
Fuel vents must have 30X30 screen installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2019
Resolution: 30X30 wire mesh was purchased and added to goose neck vents for flame screens.
Lifesaving › Lifefloat › Lifeline
Issued 11 April 2017 Resolved
Life float grablines are wasted and must be replaced.
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 26 April 2017
Resolution: New grablines were installed.
Lifesaving › Lifefloat › Netting
Issued 11 April 2017 Resolved
3 life floats need new netting and platforms. Repair/Renew.
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 26 April 2017
Resolution: New netting and platforms were installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2017 Resolved
Lanyard for strobe is wasted and must be replaced.
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 26 April 2017
Resolution: New lanyard was supplied.
Fire Fighting › Fire Pumps › Pressure
Issued 11 April 2017 Resolved
Fire pump will not achieve full pressure. Repair/Renew
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 24 April 2019
Resolution: Deficiency was resolved prior and never reflected in MISLE.
Electrical › Electric Supply System (service) › Cable
Issued 11 April 2017 Resolved
Wire run in Port hull Window void is missing supports. Provide supports every 24".
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 26 April 2017
Resolution: New metal supports were installed.
Engineering › Bilge Water Management System › Manifold
Issued 20 October 2016 Resolved
Rebuild port and starboard bilge manifolds and check valves.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 7 November 2016
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 20 October 2016 Resolved
Replace starboard cutless bearing.
Action required: 705 - Other - as specified
Resolved 7 November 2016
Engineering › Steering Gear System › Piping
Issued 20 October 2016 Resolved
Replace corroded copper steering lines from engineroom to hydraulic cylinders.
Action required: 705 - Other - as specified
Resolved 7 November 2016
Construction/Loadline › Hull › Hull Plating
Issued 20 October 2016 Resolved
Replaced all 20 windows.
Action required: 705 - Other - as specified
Resolved 7 November 2016
Construction/Loadline › Hull › Hull Plating
Issued 20 October 2016 Resolved
Witness the vessel in the water with new windows in place.
Action required: 705 - Other - as specified
Resolved 9 November 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 14 July 2011 Resolved
Provide schematics and instructions for both CO2 bottle installations in accordance with 46 CFR 185.612.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 12 August 2011
Resolution: New schematic and instructions installed. All sat.
Fire Fighting › Fire Pumps › Pressure
Issued 14 July 2011 Resolved
Fire pump gauge inop stuck at 19 psi. Conducted operational test of fire main system, hose spray was very good, adequate pressure for proper operation exist. Renew with gauge that is compatible to salt water use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 12 August 2011
Resolution: New fire pump gauge installed, test sat.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 July 2011 Resolved
Update light list and coast pilot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 12 August 2011
Resolution: Updated light list and coat pilot provided onboard. All sat.
Personnel › Training › Fire Fighting Basic
Issued 14 July 2011 Resolved
Conduct training with crew on firefighting system. Vessel has two hose stations and pump is capable of only delivering enough pressure to one hose at a time. Improper instructions posted at fixed CO2 system. Properly train all crewmembers on use and activation of fire fighting systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2011
Resolution: Training conducted with all crewmembers during inspection. Any new crewmembers that come on board must receive the same training prior to operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 3 January 2011 Resolved
The system recently had modifications made to the operating controls. The operating instructions have not been updated to include the new control system. Provide new Fixed CO2 Firefighting system schematic and operating instructions.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 February 2011
Resolved 25 August 2011
Resolution: New operating instructions and schematic installed in accordance with modifications. All sat.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 26 October 2010 Resolved
Sand back chipped epoxy coating on strut and reapply.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2010
Stability › Watertight Integrity › General
Issued 26 October 2010 Resolved
Reapply liquid gasket to #2 inboard window starboard hull interior and as needed around exterior window framing/joints both port and STBD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2010
Stability › Watertight Integrity › General
Issued 26 October 2010 Resolved
Replace aft inboard window of port hull glass bottom as original due to crack.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2010
Stability › Watertight Integrity › General
Issued 26 October 2010 Resolved
IAW 46 CFR 182.720 provide valve on PVC through bulkhead from lazarette to engine room for MSD tanks. Valve shall meet requirement found in above reference.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2010
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 October 2008 Resolved
Renew cracked welds in 2nd compartment port side IWO deck at "I" beam just at start of tunnel. Vessel may complete repairs in Key Largo before 16OCT08. Extended to 10/20/08 due to yard schedule.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 20 October 2008
Electrical › Electric Generation Source (service) › Ground Detection
Issued 14 September 2007 Resolved
Correcty ground on AC power system.
Due 6 December 2007
Resolved 12 November 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 September 2007 Resolved
Provide machinery guards for port side generator.
Due 6 December 2007
Resolved 12 November 2007
Electrical › Electric Generation Source (service) › Generator
Issued 25 April 2007 Resolved
Prove proper operation of starboard generator; Prior to completion of yard availability 30SEP2007.
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 12 November 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2007 Resolved
Provide Coast Guard approved first aid kit.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 12 November 2007
Stability › Watertight Integrity › General
Issued 12 September 2006 Resolved
Seal all wire runs throughout the vessel.
Action required: 705 - Other - as specified
Resolved 20 September 2006
Construction/Loadline › Hull › Strut/Cross Tie
Issued 12 September 2006 Resolved
Provide repair proposal for both strut. Make proper repairs to same.
Action required: 705 - Other - as specified
Resolved 20 September 2006
Construction/Loadline › Structures › Deck Plating
Issued 12 September 2006 Resolved
Repair cracked welds in void L and F.
Action required: 705 - Other - as specified
Resolved 20 September 2006
Fire Fighting › Fire Main › Condition
Issued 12 September 2006 Resolved
Properly repair corroded fire main in starboard outboard void.
Action required: 705 - Other - as specified
Resolved 22 September 2006
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 12 September 2006 Resolved
Provide flame screen for fuel oil vents.
Action required: 705 - Other - as specified
Resolved 20 September 2006
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 September 2006 Resolved
Properly repair through hole fitting in way of void #2.
Action required: 705 - Other - as specified
Resolved 20 September 2006
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 4 January 2005 Resolved
Provide documentation of qualified welder and materials list for repairs to be completed.
Due 5 January 2005
Resolved 13 January 2005
Construction/Loadline › Structures › Deck Plating
Issued 4 January 2005 Resolved
Make proper repairs to all areas identified at hull exam 01/04/05. See Activity report #2269061
Due 5 January 2005
Resolved 13 January 2005
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 4 January 2005 Resolved
Properly mount and replace missing insulation in engine rooms.
Due 5 January 2005
Resolved 13 January 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 January 2005 Resolved
Make proper repairs to starboard main engine exhaust piping.
Due 5 January 2005
Resolved 13 January 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 4 January 2005 Resolved
Make proper repairs to saltwater leak on port A/C unit salt water overboard piping. remove PVC nipple from both P/S A/C saltwater ovbd discharge lines.
Due 5 January 2005
Resolved 13 January 2005
Engineering › Fuel Oil Service System › Hose
Issued 4 January 2005 Resolved
Replace corroded fuel oil hose to port main engine
Due 5 January 2005
Resolved 13 January 2005
Fire Fighting › Fire Main › Material
Issued 4 January 2005 Resolved
Replace wasted section of piping located at entrance of starboard engine room.
Due 5 January 2005
Resolved 13 January 2005
Communications › Radio Communications › EPIRB
Issued 30 April 2003 Resolved
Renew hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Due 6 May 2003
Resolved 2 May 2003
Resolution: Corrected. Received fax copy of invoice indicating hydrostatic release was purchased.
Accommodation/Occupational Safety
Issued 11 May 1999 Resolved
Provide a sign with the maximum number of passengers allowed on the upper deck._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1999
Resolved 25 June 1999
Engineering
Issued 11 May 1999 Resolved
Provide guards over both shafts in the engine room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1999
Resolved 25 June 1999
Engineering
Issued 11 May 1999 Resolved
Provide double hose clamps on all cooling system connections._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1999
Resolved 25 June 1999
Accommodation/Occupational Safety
Issued 11 May 1999 Resolved
Provide head protection on the aft ladder to the upper deck._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1999
Resolved 25 June 1999
Engineering
Issued 11 May 1999 Resolved
Provide an easier method to close the vents to the engine room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Fire Fighting
Issued 11 May 1999 Resolved
Provide approved variable nozzles for both fire hoses._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1999
Resolved 25 June 1999
Documentation
Issued 27 April 1999 Resolved
Provide an Employee Assistance Program and associated training for the ships crewmen as required by 46 CFR subchapter A, part 16.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Documentation
Issued 27 April 1999 Resolved
Prior to the carriage of passengers, place on board a U.S. Coast Guard issued Stability Letter.
Condition: Unknown
Due 3 May 1999
Resolved 18 May 1999
Fire Fighting
Issued 27 April 1999 Resolved
Prior to the carriage of passengers, conduct a man overboard, abandon ship,and fire fighting drill as required by 46 CFR 185.57 and 46 CFR 185.524 in the presence of a U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999

Casualty record · 3

28 July 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1890088
5 August 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4105788
23 January 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5065826
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.