← All vessels

SUNDY

SUNDY is a 1977 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1985, most recently in April 2026, along with 100 deficiencies and 2 casualty investigations between 2016 and 2022.

Records from 1985 to 2026. Most recent: inspection, 1 April 2026.

Built
1977
Last inspected
1 April 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF5627
Flag
UNITED STATES
367465450, 368098420
Maury page id
psix-49071

Inspections, by type

…with no type recorded6
Years with a record 38 calendar years (1985–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.1 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 37 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE IND. INC. · SEATTLE, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSOLDOTNA, AK
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF5627MMSI 367465450 · active · compulsorily equipped · granted 3 September 2020, expires 2 September 2030
WDK8888MMSI 368098420 · active · compulsorily equipped · granted 7 June 2019, expires 7 June 2029
WTB9989MMSI not assigned · expired · compulsorily equipped · granted 23 June 1998, cancelled 23 August 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

1 April 2026 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8340971
9 September 2025 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8230355
7 August 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7976337
26 July 2024 Type not recorded
No type recorded · Maritime Safety & Security Team Seattle (91101) · Activity 7967959
14 March 2024 Internal Structural Exam · Examination of Repairs · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7877863
23 August 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7776170
5 June 2023 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7709661
9 December 2022 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7708090
7 October 2022 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7573716
27 July 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7517796
11 April 2022 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7429165
5 January 2022 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7376236
25 June 2021 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7235872
1 July 2020 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6984191
30 March 2020 Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6933870
15 November 2019 In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6858057
4 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6827916
29 May 2019 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6665710
9 June 2018 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6814507
11 April 2018 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6393705
31 July 2017 DAPI Audit
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6228370
19 July 2017 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6393719
5 November 2016 Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6110586
20 April 2016 Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5860466
17 March 2016 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5834838
10 September 2015 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5238778
17 June 2014 Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4891589
19 June 2012 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4349543
19 May 2012 Type not recorded
No type recorded · USCGC LONG ISLAND (WPB 1342) · USCG Arctic District (CGD-A) · Activity 4320081
3 February 2012 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4238085
18 January 2012 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4227256
1 December 2011 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4200486
1 July 2011 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4064537
23 April 2008 DAPI Audit · Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3192437
8 March 2007 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2884469
22 April 2006 Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2631253
13 December 2004 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2258680
5 May 2004 Re-Inspection · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2062124
3 July 2003 Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1866810
23 May 2002 Hull Examination · Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1629986
23 May 2001 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1373489
9 June 2000 Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1369686
13 July 1999 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1097001
10 June 1999 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1438854
26 May 1998 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 790022
15 May 1997 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1100082
10 May 1996 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1085130
22 April 1996 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1080630
9 May 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 891558
10 May 1994 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1354693
12 April 1994 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1449679
12 May 1993 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1385075
26 May 1992 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1264937
19 May 1992 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1260586
21 May 1991 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1309527
23 April 1991 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1307973
4 September 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1214681
14 May 1990 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 926301
5 June 1989 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1351979
6 May 1988 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1198958
27 August 1987 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1010836
4 June 1987 Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1335689
6 June 1986 Credit Drydock · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1300263
23 May 1985 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1289611

Deficiency record · 100

02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 August 2024 Resolved
Ensure laz hatch is attached to the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 1 October 2024
Resolution: chain attached hatch to vsl
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 August 2024 Resolved
Vessel is required 03 approved fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 1 October 2024
Resolution: approved fire buckets onboard
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 August 2024 Resolved
Port running light is inop. Repair. Vessel is restricted to operating during daylight and good visibility until light is operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 1 October 2024
Resolution: port running light repaired
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 August 2024 Resolved
Vessel did not have any records of drills or training. Provide drill log.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 1 October 2024
Resolution: log onboard
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 August 2023 Resolved
No FCC Operator's Permit, provide
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 25 March 2024
Resolution: provided
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 23 August 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 25 March 2024
Resolution: provided
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 August 2023 Resolved
Provide drills and training log.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 24 August 2023
Resolution: drills logged
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 August 2023 Resolved
Laz high water alarm was inop, repair or renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2023
Resolution: renewed, test sat
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 August 2023 Resolved
Stern light is inop. Repair/renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 25 March 2024
Resolution: repaired
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 23 August 2023 Resolved
Provide sign for MSD discharge valve "Do not open within 03 miles of land"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 24 August 2023
Resolution: marked
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 August 2023 Resolved
Provide 02 additional adult Type I PFDs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 25 March 2024
Resolution: provided
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 23 August 2023 Resolved
Make fwd engine room bulkhead watertight
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 24 August 2023
Resolution: made watertight
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 August 2023 Resolved
Ensure engine room hatch drains are operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 25 March 2024
Resolution: operational
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 August 2023 Resolved
Laz hatch leaks between frame and deck, repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 25 March 2024
Resolution: repaired
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 August 2023 Resolved
Provide 03 fire buckets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2023
Resolution: provided
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 August 2023 Resolved
Provide means to secure engine room ventilation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 25 March 2024
Resolution: covers fabricated
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 August 2023 Resolved
Label stowage of PFDs
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 25 March 2024
Resolution: labeled
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 August 2023 Resolved
Ensure crew enrolled in CG approved drug testing program and there is an agreement for owner to be notified if enrolled under another company.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2023
Resolution: enrolled
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 August 2023 Resolved
Ensure there is a donning placard for vest style PFD
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 25 March 2024
Resolution: removed vest style pfd
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2022 Resolved
Where rigid nonmetallic material (plastic) is permitted, protection from mechanical damage must be specifically considered and all protective covering or shields must be installed to the satisfaction of the cognizant [name withheld] hose coming from rear of STBD main engine that controls the anchor was found worn and resting against the tail shaft. Temporary repairs were made to keep hose from touching tail shaft, and shall be replaced prior to operating the vessel as an inspected vessel. 46 CFR 182.720(d)(2)
Action required: 705 - Other - as specified
Resolved 23 August 2023
Resolution: corrected
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 July 2022 Resolved
Renew charts and pubs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2022
Resolved 25 March 2024
Resolution: charts and pubs renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 June 2021 Resolved
Conducting vessel maintenance to port main engine fuel supply system. Unable to operate portside engine for sea trials. Vessel to conduct sea trials with an attending marine inspector once repairs are completed and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2021
Resolution: conducted satisfactory sea trials
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 June 2021 Resolved
Port main engine maintenance is prohibiting an accurate test of fixed fire extinguishing system Vessel to conduct test of fire boy unit prior to carrage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2021
Resolution: test sat
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 June 2021 Resolved
Engine room high water alarm was found to be inoperable. Replace and test with CG marine inspector prior to carraige of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2021
Resolution: alarm was renewed and tested sat
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 June 2021 Resolved
Vessel needs to have 03 fire buckets with lanyard attached to the handles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 1 July 2021
Resolution: fire buckets on board
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 June 2021 Resolved
Vessel needs to provide a hand bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 1 July 2021
Resolution: purchased
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 June 2021 Resolved
Vessel needs to post a life jacket placard for each type of jacket on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 1 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 30 June 2021 Resolved
Vessel master to show proof of holding a valid FCC marine radio operator permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 1 July 2021
Resolution: verified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 June 2021 Resolved
Label "Emergency Exit/Keep Clear" at on deck forward hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 1 July 2021
Resolution: marked
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2019 Resolved
The Coast Guard, on its own initiative, may inspect or reinspect, at any time, any vessel subject to inspection under subtitle II, Title 46 of the U.S. Code. Make vessel available for inspection of all firefighting, lifesaving equipment, preparations for emergency procedures, and means of escape prior to departure from Kodiak Island, AK.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2019
Resolution: Overnight passenger accomodation verification complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 May 2019 Resolved
Fixed bilge pump must pump out a minimum of 10GPM.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 5 July 2019
Resolution: repairs made to plating and hose replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 May 2019 Resolved
Repair damaged engine room vent cowl - starboard side on top of house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 3 July 2019
Resolution: repairs satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Cable and wiring in engine room must have metal supports every 24"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 5 June 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 May 2019 Resolved
Remote fuel shut off station must be marked - 1" high letters
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 5 June 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 29 May 2019 Resolved
Seal up 4 bulkhead penetrations between Laz and Engine Room
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 5 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 May 2019 Resolved
Secure electric bilge pump in Laz
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 5 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Cap open-ended wire in Laz
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 5 June 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 May 2019 Resolved
Provide FCC station license
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 8 July 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 May 2019 Resolved
Test EPIRB monthly and log in Ship's log
Action required: 705 - Other - as specified
Due 1 September 2019
Resolved 10 September 2019
Lifesaving › Lifebuoys › Serviceable
Issued 19 June 2012 Resolved
Replace life buoy.
Due 6 July 2012
Resolved 21 June 2012
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 June 2012 Resolved
Replace/repair bilge high water alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 June 2012 Resolved
Provide proof of annual servicing and demonstrate proper operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 19 June 2012 Resolved
Replace cable with splice for fireboy engine shut down.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2012
Accommodation/Occupational Safety › Heating › Piping
Issued 19 June 2012 Resolved
Properly mount fuel pump and wiring for heater.
Due 6 July 2012
Resolved 21 June 2012
Accommodation/Occupational Safety › Heating › Fuel Containers/Tanks
Issued 19 June 2012 Resolved
Install flame screen on f/o filter for heater.
Due 6 July 2012
Resolved 21 June 2012
Operations/Management › Drills/Instruction › Fire
Issued 19 June 2012 Resolved
Demonstrate proper fire & MOB drill.
Due 6 July 2012
Resolved 21 June 2012
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 1 July 2011 Resolved
Provide FCC marine radio operator permit for master.
Due 1 May 2012
Resolved 27 April 2012
Communications › Audible Communications › SPD (Other)
Issued 1 July 2011 Resolved
Provide sound producing device.
Due 7 July 2011
Resolved 12 July 2011
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 July 2011 Resolved
Provide current light list.
Due 7 July 2011
Resolved 12 July 2011
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 July 2011 Resolved
Provide current U.S. Coast Pilot.
Due 7 July 2011
Resolved 12 July 2011
Navigation › Piloting/Steering › Marine Charts
Issued 1 July 2011 Resolved
Provide current Charts.
Due 7 July 2011
Resolved 12 July 2011
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 1 July 2011 Resolved
Provide tide/current tables.
Due 7 July 2011
Resolved 12 July 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 July 2011 Resolved
Provide proof of crew enrollment in DAPI program.
Due 1 May 2012
Resolved 30 April 2012
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 July 2011 Resolved
Provide 01 adult and 01 child PFDs. Reduce Pax to 22/2 child.
Due 7 July 2011
Resolved 1 July 2011
Resolution: Procided the required PFDs with vessel name on them.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2011 Resolved
Make stern light operational.
Due 7 July 2011
Resolved 12 July 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 July 2011 Resolved
Service fixed fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2011
Resolved 1 July 2011
Resolution: Fixed fire extinguisher was serviced.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 July 2011 Resolved
Service portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2011
Resolved 1 July 2011
Resolution: Portable fire extinguishers were serviced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 July 2011 Resolved
Conduct MOB/underway drills.
Due 7 July 2011
Resolved 12 July 2011
Operations/Management › Drills/Instruction › Fire
Issued 1 July 2011 Resolved
Provide emergency instructions.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 12 July 2011
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 1 July 2011 Resolved
Provide emergency radio broadcast placard.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 12 July 2011
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 1 July 2011 Resolved
Ensure firl hoses are SAE J1942 or equivalent.
Action required: 705 - Other - as specified
Due 1 May 2012
Resolved 1 May 2012
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 July 2011 Resolved
Remove wing nuts and install standard nuts on battery terminals in E/R.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 12 July 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 July 2011 Resolved
Properly install battery terminals/wiring in center void.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 12 July 2011
Engineering › Bilge Water Management System › Piping
Issued 1 July 2011 Resolved
Determine purpose of black piping in centerline bilge-remove/cap if unneeded.
Action required: 705 - Other - as specified
Due 14 July 2011
Resolved 12 July 2011
Documentation › Certificates/Documents › FCC SSL
Issued 1 July 2011 Resolved
Provide FCC radio station license.
Due 7 July 2011
Resolved 12 July 2011
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 1 July 2011 Resolved
Provide FCC safety radio certificate.
Due 1 May 2012
Resolved 27 April 2012
Lifesaving › Buoyant Apparatus › Lifeline
Issued 1 July 2011 Resolved
Provide 60' safety line for life ring.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 1 July 2011
Resolution: 60'' of poly line was provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 July 2011 Resolved
Provide oven latch.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 30 June 2016
Resolution: Stove only to be used in port.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 July 2011 Resolved
Provide stove rails for burner area.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 30 June 2016
Resolution: Vessel labeled stove to be operated only when in port.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 1 July 2011 Resolved
Provide life raft launching placard.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 12 July 2011
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 July 2011 Resolved
Provide PFD donning placard.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 12 July 2011
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 July 2008 Resolved
Vsl only had 24 serviceable Type I PFDs. Vsl restricted to 24 total persons until full compliment of PFDs is provided.
Action required: 705 - Other - as specified
Resolved 30 June 2016
Resolution: Verified that all life jackets were on board.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 10 July 2008 Resolved
The center pilot house window was cracked. Requied vsl to replace window with approved safety glass or equivalent. No PAX allowed in pilot house until repair is made to satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 10 August 2008
Resolved 30 June 2016
Resolution: Rcvd phone call from master stating that the window was repaired.
Lifesaving
Issued 10 June 1999 Resolved
PROVIDE PROOF OF EPIRB REGISTRATION.
Condition: Unknown
Due 10 June 1999
Resolved 10 June 1999
Navigation
Issued 10 June 1999 Resolved
REPLACE DAMAGED SEAL IN STEERING CYLINDER.
Condition: Unknown
Due 10 June 1999
Resolved 10 June 1999
Lifesaving
Issued 26 May 1998 Resolved
PROVIDE RECORD OF MONTHLY EPIRB TESTING.
Condition: Unknown
Due 26 May 1998
Resolved 27 May 1998
Lifesaving
Issued 26 May 1998 Resolved
PROVIDE RECORD OF DRILLS AND TRAINING.
Condition: Unknown
Due 26 May 1998
Resolved 27 May 1998
Fire Fighting
Issued 15 May 1997 Resolved
PROVIDE ONE ADDITIONAL BII PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 22 May 1997
Resolved 3 June 1997
Navigation
Issued 15 May 1997 Resolved
PROVE PROPER OPERATION OF RADAR.
Condition: Unknown
Due 22 May 1997
Resolved 3 June 1997
Lifesaving
Issued 15 May 1997 Resolved
REPLACE ROTTEN BIGHTS ON LIFEFLOAT LIFELINE.
Condition: Unknown
Due 22 May 1997
Resolved 3 June 1997
Lifesaving
Issued 15 May 1997 Resolved
PROVIDE 6 ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 22 May 1997
Resolved 3 June 1997
Lifesaving
Issued 10 May 1996 Resolved
SECURE PAINTER TO LIFEFLOAT.
Condition: Unknown
Due 10 May 1996
Resolved 28 May 1996
Documentation
Issued 10 May 1996 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING FOR CREW.
Condition: Unknown
Due 16 May 1996
Resolved 28 May 1996
Lifesaving
Issued 10 May 1996 Resolved
REPLACE ROTTEN LINE FROM WATERLIGHT TO LIFEFLOAT.
Condition: Unknown
Due 16 May 1996
Resolved 28 May 1996
Lifesaving
Issued 10 May 1996 Resolved
REPLACE ROTTEN LINE ON RING BUOY.
Condition: Unknown
Due 16 May 1996
Resolved 28 May 1996
Lifesaving
Issued 10 May 1996 Resolved
REPLACE ROTTEN 60 FOOT LINE THAT IS ATTACHED TO RING BUOY.
Condition: Unknown
Due 16 May 1996
Resolved 28 May 1996
Engineering
Issued 10 May 1996 Resolved
PROVE PROPER OPERATION OF STARBOARD FUEL OIL SHUTOFF VALVE.
Condition: Unknown
Due 16 May 1996
Resolved 28 May 1996
Engineering
Issued 10 May 1996 Resolved
INSTALL 30 X 30 MESH VENT SCREEN IN PORT FUEL TANK VENT.
Condition: Unknown
Due 16 May 1996
Resolved 28 May 1996
Navigation
Issued 22 April 1996 Resolved
REPLACE BOLTS IN STEERING ARM THAT ATTACH TO RUDDER POST WITH PROPER SIZE BOLTS. THERE IS EXCESSIVE PLAY IN BOLTS NOW.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Construction/Loadline
Issued 9 May 1995 Resolved
INSTALL LOCKING MECHANISM TO ENGINEROOM HATCH COVERS.
Condition: Unknown
Due 11 May 1995
Resolved 12 May 1995
Construction/Loadline
Issued 9 May 1995 Resolved
INSTALL KEEPER LINE/CHAIN TO LAZARETTE HATCH COVER.
Condition: Unknown
Due 11 May 1995
Resolved 12 May 1995
Navigation
Issued 9 May 1995 Resolved
TIGHTEN/ REPAIR RUDDER PACKING ON PORT RUDDER TO PREVENT EXCESSIVE FLOODING.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Engineering
Issued 21 May 1991 Resolved
Provide guards on both main engines over fwd belts.
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Documentation
Issued 21 May 1991 Resolved
Provide evidence of stability test for exposed waters criteria for conduct test.
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Engineering
Issued 14 May 1990 Resolved
PEPLACE FUEL FILL HOSES ON BOTH FUEL TANKS. REPLACE FUEL PIPES BETWEEN FUEL TANK AND EMERG FUEL VALVES.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Lifesaving
Issued 14 May 1990 Resolved
PROVIDE PADDLES ON LIFE FLOAT.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Engineering
Issued 14 May 1990 Resolved
INSTALL GUARD OVER STBD ENG ALTENATOR AND BELTS.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Documentation
Issued 4 June 1987 Resolved
PROVIDE PROOF OF APPLICATION FOR FCC LICENSE/SHIPS RADIO STATION LICENSE.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Documentation
Issued 6 June 1986 Resolved
PROVIDE THE VESEL,S ORIGINAL CERT. OF DOCUMENTATION PRIOR TO 20 JUNE 1986.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Documentation
Issued 23 May 1985 Resolved
PROVIDE A STABILITY LETTER OR EVIDENCE OF A SATISFACTORY STABILITY TEST.
Condition: Unknown
Due 23 May 1985
Resolved 23 May 1985

Casualty record · 2

5 November 2016Routine · role: Involved in a Marine Casualty · activity 6110586
9 December 2022Routine · role: Involved in a Marine Casualty · 1 injured · activity 7708090
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.