MAURY USCG vessel records Sign in
← All vessels

WAY OF LIFE

WAY OF LIFE is a 1999 commercial fishing vessel. The Coast Guard has recorded 26 inspections since 1998, most recently in May 2017, along with 38 deficiencies.

Records from 1998 to 2017. Most recent: inspection, 3 May 2017.

Built
1999
Last inspected
3 May 2017
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE7907
490742
Flag
UNITED STATES
367399220 (licence lapsed)
Maury page id
psix-490742

Inspections, by type

Years with a record 16 calendar years (1998–2017)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 13.0 ft × 3.5 ft
Registered tonnagegross 12 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARMEN BOATS INC · MARION, MD, UNITED STATES · built 1999
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portABELL, MD
Trade endorsementsFishery
DocumentationValid · issued 6 January 2026 · expires 31 January 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE7907MMSI 367399220 · expired · compulsorily equipped · granted 13 March 2009, cancelled 18 May 2019 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

3 May 2017 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6137953
28 June 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5945435
20 July 2015 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5187109
15 July 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4109120
13 July 2011 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4080210
24 March 2009 Hull Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3439474
28 May 2008 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3222144
3 April 2007 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2880776
27 June 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2732692
28 March 2006 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2611609
12 April 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2338093
6 April 2005 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2327535
30 June 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2123226
29 November 2003 Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1955914
8 April 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1778607
26 March 2003 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1778563
10 April 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1603034
10 April 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1604008
27 March 2001 Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1366575
30 March 2000 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1361609
24 May 1999 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 798683
18 March 1999 Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1360771
2 March 1999 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 809973
12 February 1999 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1467102
16 December 1998 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1433431
23 January 1998 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1121208

Deficiency record · 38

Navigation › Piloting/Steering › US Coast Pilot
Issued 13 July 2011 Resolved
Current Coast Pilot not maintained o/b, replace as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2011
Resolution: New edition of Coast Pilot obtained and maintained o/b vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 13 July 2011 Resolved
Current charts not o/b vessel, provide as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2011
Resolution: New charts obtained & maintained o/b vessel.
Communications › Audible Communications › Horn/Whistle
Issued 13 July 2011 Resolved
2nd horn not available o/b vessel, provide as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2011
Resolved 14 July 2011
Resolution: 2nd Air Horn purchased and maintained o/b the vessel.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 July 2011 Resolved
Visible alarm for the high water alarm in the engine space inoperable, replace/repair as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2011
Resolved 26 July 2011
Resolution: Visible alarm for the engine room high water alarm replaced as new.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 July 2011 Resolved
Five (5) of the adult PFDs & two (2) of the childrens PFDs wasted, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2011
Resolution: Five adult & 2 children PFDs replaced as new.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 July 2011 Resolved
Solas reflective tape on five (5) of the adult PFDs wasted, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2011
Resolution: SOLAS tape on 5 adult and 1 child PFDs replaced as new.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 July 2011 Resolved
Alcohol test strips not maintained o/b vessel, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2011
Resolved 19 July 2011
Resolution: Alcohol test kits purchased & maintained o/b the vessel.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 13 July 2011 Resolved
Means to record persons o/b not available at the dock. Move passenger count mail box back to pier by vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2011
Resolved 21 July 2011
Resolution: Passenger count mailbox purchased and mounted at the end of the dock.
Documentation › Certificates/Documents › FCC SSL
Issued 24 March 2009 Resolved
FCC Safety Certificate expired. Renew
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 23 July 2009
Resolution: Received e-mail Pics from O/Op showing the correction of the deficiency listed above.
Engineering › Bilge Water Management System › Pump
Issued 24 March 2009 Resolved
Replace all 1500 Rule bilge pumps with U/L listed bilge pumps.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 21 July 2009
Resolution: Received e-mail Pics from O/Op showing the correction of the deficiency listed above.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 March 2009 Resolved
Provide on board new alcohol test kits (2). Kits on board expired April 2009.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 23 July 2009
Resolution: Received e-mail Pics from O/Op showing the correction of the deficiency listed above.
Lifesaving › Hand Flares › Storage
Issued 28 May 2008 Resolved
Provide approved container for hand held flares.
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 7 July 2008
Resolution: Received a call and e-mail from O/Op who stated the above deficiency had been rectified.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 May 2008 Resolved
Provide onboard alcohol test kits for master and mate.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 7 July 2008
Resolution: Received a call and e-mail from O/Op who stated the above deficiency had been rectified.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 3 April 2007 Resolved
Install a type-approved fire detection system in the engine compartment by July31, 2007.
Action required: 705 - Other - as specified
Due 1 April 2008
Resolved 28 May 2008
Resolution: Examined and satisfactorily tested a new installed pre-engineered fire boy system.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 June 2006 Resolved
Update expired items in first aid kit IAW 46 CFR 160.041.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2006
Resolved 4 July 2006
Resolution: Received fax from O/Op stating that the above deficiency had been corrected.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 27 June 2006 Resolved
Tighten shaft coupling prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2006
Resolved 4 July 2006
Resolution: Received fax from O/Op stating that the above deficiency had been corrected.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 27 June 2006 Resolved
Provide on board log book for chartered trips.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2006
Resolved 4 July 2006
Resolution: Received fax from O/Op stating that the above deficiency had been corrected.
Construction/Loadline › Structures › Door
Issued 27 June 2006 Resolved
Provide 6" coaming for entrance to cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2006
Resolved 4 July 2006
Resolution: Received fax from O/Op stating that the above deficiency had been corrected.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 June 2006 Resolved
Provide 1 Type I adult PFD on board .
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2006
Resolved 27 June 2006
Resolution: Item received prior to end of inspection.
Engineering › Bilge Water Management System › Not Operational
Issued 27 June 2006 Resolved
Bilge and High water alarms running off same switch. Separate and properly install both bilge and high water alarm systems.
Action required: 705 - Other - as specified
Due 18 July 2006
Resolved 29 August 2006
Stability › Watertight Integrity › Coaming
Issued 12 April 2005 Resolved
Provide 6-inch coaming for entrance to cabin.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 12 May 2005
Deck/Cargo › Holds/Tanks › Hatch
Issued 12 April 2005 Resolved
Provide catch cable for lazarette hatch cover.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 12 May 2005
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 April 2005 Resolved
Renew insulation on port side, interior of engine box.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 12 May 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 April 2005 Resolved
Tighten line for aft railing.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 12 May 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 April 2005 Resolved
Provide 3-6 foot lanyard for lifering water light with corrosion resistant clip.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 12 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 April 2005 Resolved
Renew retro-reflective tape on 6 selected lifejackets.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 12 May 2005
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 April 2003 Resolved
Renew retroreflective tape on PFD's designated by marine inspector LEGACY COMPONENT DESC: Retroreflective Material
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2003
Lifesaving › Buoyant Apparatus
Issued 8 April 2003 Resolved
Label lifefloat paddles with vessel name
Due 8 May 2003
Resolved 6 May 2003
Stability › Unintentional Flooding
Issued 8 April 2003 Resolved
Label high water alarms
Due 8 May 2003
Resolved 6 May 2003
Personnel › Manning/Qualifications
Issued 8 April 2003 Resolved
Provide proof of Red Cross First Aid/CPR certification for master LEGACY COMPONENT DESC: CPR Certified Personnel
Due 8 May 2003
Resolved 17 June 2003
Lifesaving
Issued 30 March 2000 Resolved
Attatch retro tape to two (2) adult lifejackets.
Condition: Unknown
Due 30 April 2000
Resolved 26 July 2000
Lifesaving
Issued 30 March 2000 Resolved
12-person Life-Float: a. Replace weak-link with an approved type for a 12-person L/F. b. Provide 2 4-foot paddles that float w/ vsl name. c. Make float-light line 18 feet. d. Make up pendents.
Condition: Unknown
Due 30 April 2000
Resolved 26 July 2000
Fire Fighting
Issued 30 March 2000 Resolved
Service 15# CO2 for fixed portable system.
Condition: Unknown
Due 30 April 2000
Resolved 26 July 2000
Fire Fighting
Issued 30 March 2000 Resolved
Service B2 fire extinguisher.
Condition: Unknown
Due 30 April 2000
Resolved 26 July 2000
Fire Fighting
Issued 30 March 2000 Resolved
Provide one (1) B1 fire extinguisher.
Condition: Unknown
Due 30 April 2000
Resolved 26 July 2000
Lifesaving
Issued 18 March 1999 Resolved
PROVIDE CORROSION RESISTANT CLIP FOR ATTACHING WATERLIGHT TO RING LIFE BUOYLANYARD.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Navigation
Issued 18 March 1999 Resolved
MOUNT "EMERGENCY INSTRUCTIONS" AT THE OPERATING STATION.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Lifesaving
Issued 18 March 1999 Resolved
PROVIDE WATERTIGHT CONTAINER FOR FIRST AID KIT.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.