Records from 2002 to 2006. Most recent: inspection, 23 June 2006.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Documentation › Logs/Records › Oil Record Book
Issued 23 June 2006
No resolution recorded
Provide and maintain an oil record book.
Action required: 15 - Rectify deficiencies by next port
Documentation › Logs/Records › Garbage Recordkeeping
Issued 23 June 2006
No resolution recorded
Provide and maintain a proper garbage record keeping log.
Action required: 15 - Rectify deficiencies by next port
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 23 June 2006
No resolution recorded
Provide plugs for all fuel/oil fixed containment.
Action required: 15 - Rectify deficiencies by next port
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 23 June 2006
No resolution recorded
Provide line diagram for oil transfer procedures.
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 13 April 2004
No resolution recorded
Provide operable working lights for all life jackets.
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Lifejacket/PFD (General)
Issued 13 April 2004
Resolved
Life jackets are locked and tied in rice sacks. Ensure PFD's are accessible to crew. LEGACY COMPONENT DESC: Storage
Due 14 April 2004
Resolved 13 April 2004
Documentation › Logs/Records › Oil Record Book
Issued 13 April 2004
No resolution recorded
Provide and maintain oil record book.
Action required: 15 - Rectify deficiencies by next port
Documentation › Logs/Records › Garbage Recordkeeping
Issued 13 April 2004
No resolution recorded
Provide and maintain garbage record book.
Action required: 15 - Rectify deficiencies by next port
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 13 April 2004
No resolution recorded
Ensure all fuel and lube oil vents, over flow and fill ppipes have containment and plugs.
Action required: 15 - Rectify deficiencies by next port
Documentation › Certificates/Documents
Issued 13 April 2004
Resolved
Vessel has an expired IOPP certificate, provide a valid IOPP certificate. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2004
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 April 2004
No resolution recorded
Provide line diagram for oil transfer procedures.
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 April 2004
No resolution recorded
Stencil or mark vessel name on all life jackets.
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 April 2004
No resolution recorded
Mark life buoys with vessel name.
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 13 April 2004
Resolved
All fire extinguishers on board are inoperable. Provide 5 B-II fire extinguishers. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2004
Personnel › Certificates/Documents/Licenses › PIC
Issued 13 April 2004
No resolution recorded
Provide letter of designation for Person in Charge for oil transfers.
Action required: 15 - Rectify deficiencies by next port
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 April 2004
No resolution recorded
Vessel has an electric incinerator marine sanitation device with out bags. Provide bags for incinolet.
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Semiportable CO2 Fire Extinguishers
Issued 13 April 2004
Resolved
Vessel has an inoperable B-III fire extinguisher. Provide replacement B-III. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2004