Records from 1985 to 1992. Most recent: inspection, 8 September 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 26 August 1991
Resolved
PROVIDE A SIGNED LOG ENTRY DOCUMENTING OPERATIONAL TESTS OF THE #2 SSG OVERSPEED SHUTDOWN, LUBE OIL PRESSURE SHUTDOWN, AND REVERSE POWER RELAY UPON COMPLETION OF REPAIRS. DEMONSTRATE THE SAME IN PRESENCE OF A COAST GUARD MARINE INSPECTOR AT NEXT INSPECTION.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Electrical
Issued 26 August 1991
Resolved
INSTALL EMERGENCY LIGHTING FORTHE PORT LIFERAFT STATION.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Construction/Loadline
Issued 26 August 1991
Resolved
MAKE PROPER REPAIRS TO THE #2 BALLAST PUMP IN THE PORT PUMP ROOM.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Documentation
Issued 26 August 1991
Resolved
PROVIDE ON BOARD REVISED/APPROVED CONSRUCTION PORTFOLIO.
Condition: Unknown
Due 26 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 26 August 1991
Resolved
REPLACE ALL MANILA LINE ON ALL LIFE RING BUOYS WITH POLYPROPYLENE LINE
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Documentation
Issued 26 August 1991
Resolved
PROVIDE ON BOARD FULL COMPLEMENT OF CREW AS REQUIRED BY 46 CFR PART 15 AND THE CURRENT CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Electrical
Issued 26 August 1991
Resolved
PROVE PROPER OPERATION OF LOSS OF PURGE SHUTDOWN FOR THE TV MONITORS ON THEDRILL FLOOR
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Electrical
Issued 26 August 1991
Resolved
MAKE PROPER REPAIRS TO THE FOLLOWING EMERGENCY LIGHT STATIONS: STBD FWD CORNER, PORT FWD CORNER, #1 & #2 LIFEBOATS, SWITCH GEAR ROOM, ENG RM BY THE#4 GENERATOR, AND THE MUD PUMP ROOM.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Engineering
Issued 26 August 1991
Resolved
TEST CLAYTON STEAM GENERASTOR #2 TO INCLUDE SAFETY LIMITS AND SET AND SEAL SAFETY VALVES
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Electrical
Issued 26 August 1991
Resolved
REPLACE TACHOMETER ON THE #1 SHIP SERVICE GENERATOR
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Electrical
Issued 7 March 1991
Resolved
PROVIDE TACHOMETERS WHERE MISSING ON ALL SHIP SERVICE GENERATORS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Engineering
Issued 7 March 1991
Resolved
PROVIDE PROPERLY RATED RELIEF VALVES FOR THE STARTING AIR RECEIVER AND THE SANITARY SYSTEM AIR RECEIVER (200 PSI OR LESS FOR STARTING AIR AND 100 PSI OR LESS FOR SANITARY SYSTEM) AND MAKE AVAILABLE FOR TEST.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991
Resolved
INSTALL PERMANENT EMERGENCY LIGHTING FOR THE #3 LIFEBOAT STATION.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991
Resolved
PROVIDE COVERS FOR THE BLANKS WHERE MISSING IN THE DISTRIBUTION PANELS IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991
Resolved
MAKE PROPER REPAIRS TO THE FOLLOWING EMERGENCY LIGHT STATIONS: ENGINE CONTROL ROOM, PORT AFT 21 FT. LEVEL, PORT AFT MAIN DECK ELEVATOR SHAFT, ANDAT STARBOARD CRANE.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Engineering
Issued 7 March 1991
Resolved
TEST CLAYTON STEAM GENERATORS AUTOMATION PROCEDURES AND SAFETY VALVES.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991
Resolved
MAKE PROPER RERAIRS TO AND TEST #1 AND #2 SHIP SERVICE GENERATORS OVERSPEEDPROTECTION, LOW LUBE OIL SHUTDOWN, AND #1 TEMPERATURE ALARMS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991
Resolved
TEST REVERSE POWER RELAYS ON THE #1, 2, AND 3 SHIP SERVICE GENERATORS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991
Resolved
PROVIDE FOAM ANALYSIS REPORT.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991
Resolved
REPLACE BULBS IN ALL THE HELD DECK LIGHTING.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Accommodation/Occupational Safety
Issued 7 March 1991
Resolved
TEST RELIEF VALVES ON ALL PRESSURE VESSELS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Lifesaving
Issued 7 March 1991
Resolved
PROVIDE USCG APPROVED PROVISIONS FOR ALL LIFEBOATS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991
Resolved
LABEL ALL FIRE DAMPERS AND REMOTE FUEL SHUTOFFS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991
Resolved
REPAIR OR REPLACE FIRE DAMPERS NO. 8, 9, & 10.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Lifesaving
Issued 7 March 1991
Resolved
PROVIDE TWO SMOKE FLARES FOR EACH LIFEBOAT.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Lifesaving
Issued 7 March 1991
Resolved
PROVIDE USCG APPROVED WATER FOR THE #4 LIFEBOAT (SEE SPECIAL INSTRUCTIONS).
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Lifesaving
Issued 7 March 1991
Resolved
PROVIDE FISHING KITS AND DITTY BAGS FOR ALL LIFEBOATS IN ACCORDANCE WITH 46CFR 94.20-10.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Construction/Loadline
Issued 7 March 1991
Resolved
REPAIR OR REPLACE DOORS TO THE MUDPIT ROOM TO PROVIDE SELF-CLOSING, GASTIGHT DOORS IN ACCORDANCE WITH 46 CFR 108.175.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Engineering
Issued 30 August 1989
Resolved
CONDUCT OPERATIONAL TESTS OF VESSEL'S EIGHT THRUSTERS, PROPULSION AND DYNAMIC POSITIONING SYSTEMS PRIOR TO GETTING UNDERWAY; PROVIDE A COPY OF LOG ENTRY DOCUMENTING THE RESULTS OF SUCH TESTS TO THE ABOVE OFFICE.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Fire Fighting
Issued 30 August 1989
Resolved
PROVIDE THE FOLLOWING PLANS TO THE ABOVE OFFICE FOR COAST GUARD APPROVAL: (1) FIRE CONTROL PLAN (2) HAZARDOUS LOCATIONS DRAWING
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Fire Fighting
Issued 30 August 1989
Resolved
PROVIDE EVIDENCE OF ANNUAL SERVICING OF FIRE EXTINGUISHING SYSTEMS (COMPLETE REPORT) AND FOAM ANALYSIS TO THE ABOVE OFFICE. REF: 46CFR109.223
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Lifesaving
Issued 30 August 1989
Resolved
PROVIDE ONBOARD, REQUIRED LINE THROWING APPLIANCE AND MISSING LAUNCHING GEAR. REF: 46CFR109.320 & 108.517
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Documentation
Issued 30 August 1989
Resolved
SUBMIT FOR APPROVAL BY THE MARINE SAFETY CENTER, THE VESSEL'S (1) REVISED CONSTRUCTION PORTFOLIO AND (2) OPERATIONS MANUAL IN ACCORDANCE WITH 46CFR109.121. SEE SPECIAL INSTRUCTIONS FOR ADDRESS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989
Resolved
PROVIDE A SIGNED LOG ENTRY DOCUMENTING OPERATIONAL TESTS OF THE NO.2 SHIP'SSERVICE GENERATOR'S OVERSPEED SHUTDOWN, LOW LUBE OIL PRESSURE SHUTDOWN, ANDREVERSE POWER RELAY UPON COMPLETION OF REPAIRS. DEMONSTRATE THE SAME IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Lifesaving
Issued 30 August 1989
Resolved
AMEND VESSEL'S STATION BILL SO AS TO INCORPORATE THE ASSIGNMENT OF ALL FOUR LIFE BOATS. REF: 46CFR109.501-.505
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989
Resolved
PROVIDE A PRESSURE RELIEF VALVE OR RUPTURE DISC, SET AT OR BELOW MAWP OF TANK, ON AIR STORAGE VESSEL FOR DIESEL POWERED FORKLIFT; INSTALL AUDIBLE BACKING ALARM ON SAME VEHICLE.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Construction/Loadline
Issued 30 August 1989
Resolved
PROVIDE A COPY OF ABS REPORT DOCUMENTING THE RESULTS OF ANNUAL CRANE INSPECTION /TESTS; SATISFACTORY COMPLETION OF REPAIRS (PERMANENT) TO STARBOARD FORWARD 18FT COLUMN, AND STARBOARD AFT 30FT COLUMN; NO. 8 THRUSTER SHELL REPAIRS AND THRUSTER PEDESTAL REPAIRS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989
Resolved
INSTALL PROPER EXPLOSION PROOF ELECTRICAL EQUIPMENT AND FITTINGS IN DESIGNATED CLASS I DIV I LOCATIONS AS SHOWN ON EXISTING CLASSIFIED AREAS DRAWING OR SUBMIT REVISED HAZARDOUS LOCATION DRAWING TO THE ABOVE OFFICE FOR APPROVAL.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989
Resolved
PROVIDE A SIGNED LOG ENTRY DOCUMENTING SATISFACTORY OPERATIONAL TEST OF THE NO.1 SHIP SERVICE GENERATOR'S REVERSE POWER RELAY.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 20 February 1989
Resolved
TEST OVERSPEED TRIPS, LOW LUBE OIL PRESSURE AND HIGH WATER TEMP ALARMS ON #1 AND #2 SHIP'S SERVICE GENERATORS.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Lifesaving
Issued 20 February 1989
Resolved
WEIGHT TEST, OPERATE IN THE WATER AND ENERGIZE WATER SPRAY SYSTEM ON LIFEBOATS #1, #2, #3, AND #4.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Engineering
Issued 20 February 1989
Resolved
INTERNALLY INSPECT THE FOLLOWING TENSIONER BOTTLES AND TEST CORRESPONDING RELIEF VALVES: #1, #2, #3, #4, #5, #6, #7, #8, #9, #10, #11, #12, #13, #14,#15, #16, #17, #18, #19, #20, #21, #22, #23, #24, #25, #26, #28, #29 AND #30.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Lifesaving
Issued 20 February 1989
Resolved
CONDUCT ANNUAL SERVICING OF INFLATABLE LIFERAFTS #1, #2, #3, #4, AND #5 AT A U.S. COAST GUARD APPROVED FACILITY, IN THE PRESENCE OF A U.S. COAST GUARDINSPECTOR.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Fire Fighting
Issued 20 February 1989
Resolved
TEST THE FOLLOWING RELIEF VALVES: #1 AND #2 FIRE PUMPS AND #1 AND #2 CLAYTON BOILER FEED WATER PUMPS AND HALLIBURTON AIR RECEIVER LOCATED IN THEMUD PUMP ROOM.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Lifesaving
Issued 20 February 1989
Resolved
REPLACE GLAZED WINDOWS IN LIFEBOATS #1, #2, #3 AND #4.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Accommodation/Occupational Safety
Issued 20 February 1989
Resolved
REPAIR AND OR ADJUST, THEN DEMONSTRATE OPERATION OF THE FOLLOWING VENT CLOSURES: #124, #125, #128, #145, #154, #157, #166 AND #169.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Deck/Cargo
Issued 20 February 1989
Resolved
INTERNALLY INSPECT DRY BULK TANKS #8500 AND #8501, MIXING TANKS #8508 AND #8510 AND AIR RECEIVER #36. TEST RELIEF VALVE ON AIR RECEIVER #36.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Fire Fighting
Issued 15 April 1988
Resolved
PROVIDE A WORE/METALLIC SAFETY LINE FOR EMERGENCY GEAR BOXES AND HAVE ALL SELF CONTAINED BREATHING APPARATUS BOTTLES HYDRO STATICALLY TESTED. (46 CFR 108.497)
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Lifesaving
Issued 15 April 1988
Resolved
PROVIDE NEW EXHAUSTS FOR ALL LIFEBOATS AAND REPLACE ALL GLAZED WINDOWS. (46 CFR 160.035)
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Electrical
Issued 15 April 1988
Resolved
REPLACE WIRE TO MOTOR OF #2 LIFEBOAT. (46 CFR 108.507)
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Lifesaving
Issued 15 April 1988
Resolved
PROVIDE EVIDENCE OF LIFERAFT SERVICING, HYDRO RELEASE SERVICING AND DAVIT HOOK SERVICING. NOTE: WHEN REINSTALLING HYDRO RELEASE ENSURE THEY ARE STRETCHED TAUT TO SECOND NOTCH IN STEM. (46 CFR 107.231)
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Lifesaving
Issued 15 April 1988
Resolved
PROVIDE NEW LAUNCH INSTRUCTIONS FOR BOTH THE LIFERAFT AND THE DAVIT SYSTEM AT EACH LIFERAFT LOCATION. (46 CFR 108.508)
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Lifesaving
Issued 15 April 1988
Resolved
PROVIDE TABLE OF LIFESAVING SIGNALS FOR EACH LIFEBOAT AND POST SAME ON INTERIOR OF BOAT. (46 CFR 108.503(D))
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Deck/Cargo
Issued 15 April 1988
Resolved
PROVIDE DEADMAN NOZZLE FOR STBD CRANE. (46 CFR 108.600)
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Engineering
Issued 15 April 1988
Resolved
REPLACE BROKEN SIGHT GLASS ON TELRUS 46 TANK ON SPIDER DECK AND PROVIDE FLAME SCREENS FOR VENTS TO SAME. (46 CFR 56.50-80)
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Electrical
Issued 15 April 1988
Resolved
PROVIDE GUARDS FOR GLOBES ON PERIMETER OF HELODECK. (46 CFR 111.75-20)
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Lifesaving
Issued 21 February 1987
Resolved
PROVIDE SUITABLE COVERS FOR LIFE BOAT DAVIT EQUIPMENT IN ACCORDANCE WITH 46 CFR 94.30-5
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW FLASHLIGHT BATTERIES AND SPARES, ALL LIFE BOATS
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
PROVIDE CG APPROVED FIRST AID KIT FOR LIFE BOAT #4
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
PROVIDE COPY OF STRUCTURAL TEST REPORT (NDT TESTING) PERFORMED BY HANSON ENGINEERING LTD.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
PROVIDE BRACKET FOR FIRE EXTINGUISHER, LIFE BOAT #3
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
PROVIDE CG APPROVED FIRST AID KIT FOR LIFE BOAT #2
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW FLASHLIGHT BATTERIES AND SPARES FOR LIFE BOAT #1
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW 2 FLOATING ORANGE SMOKE SIGNALS FOR LIFE BOAT #1
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Engineering
Issued 21 February 1987
Resolved
PROVE OPERATION OF ALL ALARMS AND SHUTDOWNS ON TWO CLAYTON AND 2 PARKER BOILERS TO CG MARINE INSPECTOR.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
CLEAN BILGE/CONTAINMENT AREAS UNDER ALL MOTOR/GENERATOR SETS IN ENGINE ROOM
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
PROVIDE FLAME SAFETY LAMPS AT ALL EMERGENCY GEAR LOCKERS FOR FIREMAN'S OUTFITS
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
OPEN AND INSPECT FOR DAMAGE FROM OVER HEATING, THE BRAKE ASSEMBLY ON #4 LIFEBOAT DAVIT
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
LABEL WATER TIGHT DOOR AND ADJUST FOR PROPER CLOSURE, 30 FOOT COLUMN, PORT AFT, PUMP ROOM ACCESS
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
LABEL WATER TIGHT DOORS AND ADJUST FOR PROPER CLOSURE, 30 FOOT CLOUMN, PORTAFT, THRUSTERS #7 & #8 ACCESS ON 21 FT FLAT
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
LABEL WATER TIGHT DOOR, 30 FOOT LOUMN, PORT AFT, 21 FT FLAT, AS PER 46 CFR 97.37-60
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
ADJUST WATER TIGHT DOOR FOR PROPER CLOSURE, 30 FOOT COLUMN, PORT AFT, 90 FT FLAT
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
ADJUST WATER TIGHT DOOR FOR PROPER CLOSURE, 30 FOOT COLUMN, STBD AFT, PUMP ROOM ACCESS.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
ADJUST WATER TIGHT DOORS FOR PROPER CLOSURE, THRUSTERS #5 & #6 ACCESS, 30 FOOT COLUMN, STBD AFT, 21 FOOT FLAT.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
LABEL AND ADJUST WATER TIGHT DOOR FOR PROPER CLOSURE, 30 FOOT COLUMN, STBD AFT, 21 FOOT FLAT, ELEVATOR ACCESS.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
LABEL WATER TIGHT DOOR AND ADJUST FOR PROPER CLOSURE, 30 FOOT COLUMN, STBD AFT, 90 FOOT FLAT.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
ADJUST DOGS ON WATER TIGHT DOORS AND ASSURE PROPER CLOSURE, THRUSTERS #3 & #4 ACCESS DOORS. 30 FT COLUMN, STBD FWD, 21 FT FLAT.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
LABEL WATER TIGHT DOOR IN 30 FT COLUMN , STBD FWD, 21 FOOT FLAT, AS PER 46 CFR 97.37-60
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
LABEL WATER TIGHT DOOR IN 3O FT COLUMN STBD FWD 90 FOOT FLAT, AS PER 46CFR97.37-60
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
REPAIR HALIBURTON COMPRESSOR EXHAUST FIRE DAMPER (#174) RENEW DOG.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
REPAIR PORT HULL PUMP ROOM EXHAUST FIRE DAMPER (#169) RENEW DOG. (ON DECK)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
REPAIR LAUNDRY SUPPLY FIRE DAMPER (#LS)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
REPAIR GALLEY FIRE DAMPER (#SF1)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
REPAIR ENGINE ROOM SUPPLY FIRE DAMPER (#53) FROZEN OPEN.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
REPAIR SWITCH GEAR ROOM FIRE DAMPER (#31) BROKEN VANE
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
REPAIR MACHINE SHOP EXHAUST FIRE DAMPER (#27)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
REPAIR BOILER ROOM SUPPLY FIRE DAMPER (#48) SPRING CLOSURE DEVICE.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
STENCIL OARS AND BOOT HOOKS, LIFE BOAT #1
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW CAPS ON PROVISION LOCKERS AND MAKE WATER TIGHT, LIFE BOAT #1
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
PROVIDE MONKEY FISTS ON HEAVING LINES IN LIFE BOAT #1
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
CLEAN, REFURBISH AND REPAINT/REMARK WHITE LINE , RELEASING GEAR AND DRAIN PLUG LOCATIONS
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW CAPS ON PROVISION LOCKERS AND MAKE WATER TIGHT, LIFE BOAT #4
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
STENCIL LIFE RAFT BOARDING STATIONS IN ACCORDANCE WITH 46 CFR 97.37-40
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW ONE BOX OF SERVICE LINE FOR LINE GUN
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
MARK BOX CONTAINING LINE THROWING GUN AND PROJECTILES IN ACCORDNACE WITH 46 CFR 97.37-45
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW 12 RED PARACHUTE FLARES, LIFE BOAT #4
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW 12 HAND HELD RED FLARES, LIFE BOAT #4
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW TWO HAND HELD RED FLARES, LIFE BOAT #3
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW CAPS ON PROVISION LOCKERS AND MAKE WATER TIGHT, LIFE BOAT #2
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
ADJUST LIMIT SWITCH ACTUATOR ARM ON STBD DAVIT, LIFE BOAT #1
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
PROVIDE EXPLOSION PROOF 3 CELL FLASH LIGHT AT MUD PUMP ROOM EMERGENCY LOCKER FOR FIREMAN'S OUTFIT
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
STENCIL NO SMOKING SIGNS AT EACH ENTRANCE TO HELO DECK
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Navigation
Issued 21 February 1987
Resolved
REPAIR LIGHT SWITCH FOR GYRO REPEATER ON HELO DECK AND SHOW PROVE OPERATIONOF REPEATER
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
REPLACE MISSING NET OR PROVIDE HAND RAILS AROUND LADDER FROM HELO DECK TO BRIDGE
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Accommodation/Occupational Safety
Issued 21 February 1987
Resolved
PROVIDE HINGED UPPER BUNKS IN HOSPITAL SPACE, 46 CFR 92.20-35
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
REPLACE MISSING DECK SOCKET COVER FOR DECK SOCKET, IN WAY OF THE 18 FT COLUMN, STBD FWD.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
REPLACE OR REPAIR REACH ROD DECK SOCKET FOR SUMP VALVE IN WAY OF 18 FT COLUMN, STBD FWD.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
REPAIR AND ADJUST FOR PROPER CLOSURE, FIRE DOOR, MAIN DECK, PORT SIDE AFT ACCESS TO ACCOMODATIONS
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
PROVIDE COPY OF SERVICE REPORT AND FOAM ANALYSIS ON FIXED AND PORTABLE FIREFIGHTING EQUIPMENT. (DON BRENTON'S FIRE PROTECTION SERVICES)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Documentation
Issued 21 February 1987
Resolved
PROVIDE COPY OF LOAD LINE CERTIFICATE WHEN ISSUED BY ABS
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Documentation
Issued 21 February 1987
Resolved
PROVIDE COPY OF SAFETY CONSTRUCTION CERTIFICATE WHEN ISSUED BY ABS.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Documentation
Issued 21 February 1987
Resolved
PROVIDE COPY OF SAFETY CONSTRUCTION CERTIFICATE AMENDMENT WHEN ISSUED BY ABS.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
PROVIDE COPY OF DIVERS SURVEY REPORT AND VIDEOTAPE OF UNDERWATER BODY SURVEY CONDUCTED BY DOMINION DIVING.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
SHOW ALL GAS DETECTORS FUNCTION PROPERLY
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Navigation
Issued 21 February 1987
Resolved
PROVE OBSTRUCTION LIGHTS MEET INTENSITY AND ALIGNMENT RQMTS
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
MAKE PERMANENT REPAIRS TO CRACK ON PORT FWD COLUMN, IN WAY OF THE GUSSET FOR THE 4 FOOT TUBULAR DIAGONAL
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Documentation
Issued 21 February 1987
Resolved
UPDATE SAFETY PLAN TO SHOW NEW LIFERAFT LOCATIONS. SUBMIT CHANGES TO [name withheld]
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
PROVE OPERATION OF OVERSPEED TRIPS AND OTHER EMERGENCY SHUT DOWNS ON #8 MAIN ENGINE TO CG MARINE INSPECTOR.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Fire Fighting
Issued 21 February 1987
Resolved
PROVE OPERATION OF ALL EMERGENCY VENTILATION SHUTDOWNS TO CG MARINE INSPECTOR.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
PROVE OPERATION OF REVERSE CURRENT RELAY AND PARALLEL GENERATOR OPERATION TO CG MARINE INSPECTOR
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Unknown
Issued 21 February 1987
Resolved
REPAIR CHECK VALVE IN OVERBOARD DISCH LINE (8") STBD AFT COLUMN ON 21 FT FLAT. PROVE PROPER OPERATION.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Unknown
Issued 21 February 1987
Resolved
OPEN TWO AIR RECEIVERS (GARDNER-DENVER) FOR INTERNAL INSPECTION BY CG MARINE INSPECTOR. (ENG ROOM)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Accommodation/Occupational Safety
Issued 21 February 1987
Resolved
REPAIR ALL SHOWERS AND WASH BASINS TO PROVIDE HOT AND COLD WATER 46 CFR 92.20-25
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
REPAIR EXIT LIGHT NEAR CABINS 9 & 10 (EMERG LIGHT)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
REPAIR EXIT LIGHT NEAR CABINS 14 & 15 (EMERG LIGHT)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
REPAIR EXIT LIGHT AT PANTRY DOOR (EMERG LIGHT)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
REPAIR EXIT LIGHT AT QUARTERS DOOR EX 48
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
REPLACE LEAKING BATTERY IN FIRE DETECTION ALARM PANEL (EMERG BACKUP POWER)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Unknown
Issued 21 February 1987
Resolved
REPAIR HOLE CUT IN BATTERY ROOM BULKHEAD
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Engineering
Issued 21 February 1987
Resolved
REPLACE MISSING GLOBE FOR ROTATING BEACON ON #1 MAIN ENGINE
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Unknown
Issued 21 February 1987
Resolved
APPLY SUITABLE NON SKID SURFACE TO HELO DECK
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
LABEL WATER TIGHT DOOR AND ADJUST FOR PROPER CLOUSRE, 30 FOOT CLOUMN, PORT FWD, THRUSTER #2 ACCESS ON 21 FT FLAT
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
LABEL WATER TIGHT DOOR AND ADJUST FOR PROPER CLOSURE, 30 FOOT CLOUMN, PORT FWD, 90 FT FLAT
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Engineering
Issued 21 February 1987
Resolved
REPLACE MISSING GLOBE FOR ROTATING BEACON ON #2 MAIN ENGINE
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW TWO EXPIRED HAND HELD, RED FLARES FROM LIFE BOAT #1
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
ADJUST WATER TIGHT DOOR FOR PROPER CLOSURE, PORT FWD, MAIN DECK ELEVATOR ACCESS.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
ADJUST WATER TIGHT HATCH FOR PROPER CLOSURE, 30 FOOT COLUMN, PORT FWD, MAINDECK HATCH.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
RENEW GASKET AND ADJUST WATER TIGHT HATCH FOR PROPER CLOSURE, 18 FT COLUMN PORT FWD, MAIN DECK HATCH.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
ADJUST WATER TIGHT DOOR FOR PROPER CLOSURE, PORT AFT, MAIN DECK ELEVATOR ACCESS.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
RENEW DOGS AND ADJUST WATER TIGHT HATCH FOR PROPER CLOSURE, 30 FOOT COLUMN STBD AFT, MAIN DECK HATCH.
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
ADJUST WATER TIGHT DOOR FOR PROPER CLOSURE, STBD FWD, MAIN DECK ELEVATOR ACCESS
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 21 February 1987
Resolved
RENEW DOGS AND ADJUST FOR PROPER CLOSURE, 30 FOOT COLUMN, STBD FWD, MAIN DECK HATCH
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Engineering
Issued 21 February 1987
Resolved
REPLACE GLOBE ON ROTATING BEACON ON #3 MAIN ENGINE
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Lifesaving
Issued 21 February 1987
Resolved
RENEW ALL EXPIRED WATER LIGHT BATTERIES ON EXPOSURE SUITS, STENCIL AND PRESENT FOR INSPECTION
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
RENEW FAULTY TEMPERATURE GUAGE AT FWD END OF #3 MAIN ENGINE (LUBE OIL TEMP)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
REATTACH BY WELDING, THE PIPE HANGERS FOR (1/2"-3/4") PIPE OVER #3 MAIN ENG
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
REPLACE FAULTY TEMPERATURE GUAGE AT FWD END OF #4 MAIN ENGINE (LUBE OIL)
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Electrical
Issued 21 February 1987
Resolved
REPLACE FAULTY S.W. DISCHARGE GUAGE BETWEEN #4 AND #5 MAIN ENGINES
Condition: Unknown
Due 21 February 1987
Resolved 21 February 1987
Construction/Loadline
Issued 12 February 1986
Resolved
THE PROPOSED STRUCTURAL CHANGES TO THE WHEEL HOUSE MUST BE DONE IN ACCORD- ANCE WITH U.S. COAST GUARD APPROVED PLANS AND THE COMPLETED CHANGES MUST BEEXAMINED BY A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Fire Fighting
Issued 12 February 1986
Resolved
PROVIDE A COPY OF THE RESULTS OF LATEST FIXED FIRE FIGHTING SYSTEM TESTS.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Electrical
Issued 12 February 1986
Resolved
REPAIR SOUNDPOWERED PHONE SYSTEM TO ALL FOUR ELEVATORS.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Unknown
Issued 12 February 1986
Resolved
CONDUCT OPERATIONAL TEST OF DRILLERS CONSOLE PURGE SYSTEM.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Fire Fighting
Issued 12 February 1986
Resolved
TEST SMOKE DETECTION SYSTEM, WHEN INSTALLATION COMPLETED, IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 February 1986
Resolved 12 February 1986
Fire Fighting
Issued 1 May 1985
Resolved
D1 SUBMIT NEW FIRE CONTROL PLANS FOR APPROVAL SHOWING THE FOLLOWING: ALL DECKS, ACCOMMODATIONS, STRUCTURAL FIRE PROTECTION, FIREFIGHTING EQUIPMENT, ACCESSES, AND VENTILATION SHUTDOWNS.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985
Electrical
Issued 1 May 1985
Resolved
E4 RESTRAP ALL WIRES TO #5 THRUSTER SPACE AND MAKE BULKHEAD PENETRATIONS WATERTIGHT.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985
Electrical
Issued 1 May 1985
Resolved
E3 REPLACE CONTROL WIRING TO BOTH PARKER BOILERS. WIRING MUST BE IN ACCORDANCE WITH 46 CFR 111.60.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985
Unknown
Issued 1 May 1985
Resolved
E2 PROVIDE SHUTOFF VALVES TO ALL LINES COMING FROM THE WASTE OIL TANK.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985
Electrical
Issued 1 May 1985
Resolved
E1 REPAIR SOUND POWERED TELEPHONE IN STARBOARD AFT ELEVATOR.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985
Construction/Loadline
Issued 1 May 1985
Resolved
D2 TEST ALL CHAIN LOCKER SEALS.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985
Electrical
Issued 1 May 1985
Resolved
E6 PROVIDE GENERAL ALARM BELL TO ACCOMMODATION TRAILER.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985
Electrical
Issued 1 May 1985
Resolved
E5 TEST REVERSE POWER RELAY ON #3 AND #8 SHIP SERVICE GENERATORS.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985
Lifesaving
Issued 7 March 1985
Resolved
CONDUCT WEIGHT TEST AND OPERATIONAL TEST TO ALL LIFE BOATS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 7 March 1985
Resolved
CONDUCT EMERGENCY GENERATOR OPERATIONAL TEST
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 7 March 1985
Resolved
CONDUCT OPERATIONAL TEST TO EMERGENCY LIGHTING SYSTM
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Engineering
Issued 7 March 1985
Resolved
CONDUCT OPERATIONAL TEST TO ALL FUEL OIL REACHRODS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 7 March 1985
Resolved
CONDUCT OPERATIONAL TEST OF HAZAROUS ZONES VENT ALARMS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 7 March 1985
Resolved
CONDUCT OPERATIONAL TEST# 1 AND #4 MAIN ENGINE SHUT DOWNS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 7 March 1985
Resolved
CONDUCT OPERATIONAL TEST MAIN ENG GEN REVERSE POWER RELAYS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Engineering
Issued 7 March 1985
Resolved
OPEN FOR INTERNAL EXAMINATION ALL PRESSURE VESSELS IN THE ENG ROOM AND MMDPUMP ROOM.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Engineering
Issued 7 March 1985
Resolved
CONDUCT OPERATIONAL TEST TO ALL BOILERS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Engineering
Issued 7 March 1985
Resolved
REPAIR OR REPLACE #1 BOILER SAFETY VALVE
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Deck/Cargo
Issued 7 March 1985
Resolved
PROVIDE TEST REPORT FOR MARINE PORTABLE TANKS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Construction/Loadline
Issued 7 March 1985
Resolved
RETEST CHAIN LOCKER SEALS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Deck/Cargo
Issued 7 March 1985
Resolved
PROVIDE ANNUAL CRANE SURVEY REPORT
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Navigation
Issued 7 March 1985
Resolved
PROVIDE A NEW RADIO TELEGRAPH CERTIFICATE. CURRENT CERTIFICATE EXPIRES 9APR85
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Lifesaving
Issued 7 March 1985
Resolved
PROVIDE COPIES OF LIFERAFT SERVICE CERTIFICATE
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Fire Fighting
Issued 7 March 1985
Resolved
PROVIDE FOAM ANALYSIS REPORT
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Fire Fighting
Issued 7 March 1985
Resolved
REPAIR INOPERATIVE GER ALARM BELLS
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Lifesaving
Issued 7 March 1985
Resolved
TEST EMBARKATION LADDER
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Unknown
Issued 7 March 1985
Resolved
MAKE COMBUSTABLE GAS INDICATOR SENSOR FOR ROTARY TABLE OPERATIVE
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 7 March 1985
Resolved
ADJUST PA SYSTEM AFT OF SPIDER DECK
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Engineering
Issued 7 March 1985
Resolved
REPLACE ALL SIGHT GLASSES CONTAINING FLAMMABLE PRODUCTS WITH FIREPROOF SIGHT GLASSES
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 7 March 1985
Resolved
REPAIR INOPERATIVE SOUND POWER PHONE IN PORTAFT COLUMN ELEVATOR
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 7 March 1985
Resolved
TEST DRILLER CONSOLE PURGE SYSTEM
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Construction/Loadline
Issued 7 March 1985
Resolved
REPAIR OR REPLACE WEATHERTIGHT DOORS WHICH DO NOT PASS CHALK TEST
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Fire Fighting
Issued 7 March 1985
Resolved
SUBMIT NEW FIRE CONTROL PLAN SHOWING: DECKS, ACCOMODATIONS, BULKHEADS(FIRE RATINGS), EXTINGUSHER AND ALARM SYSTEM, ACCESSORIES, VENT SYSTEMS(SHUT DOWNS)
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985