LANA J

LANA J is a 1977 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1986, most recently in April 2026, along with 75 deficiencies and 1 casualty investigation in 2019.

Records from 1986 to 2026. Most recent: inspection, 27 April 2026.

Built
1977
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC9144
Flag
UNITED STATES
367098150
Maury page id
psix-49082

Inspections, by type

…with no type recorded4
Years with a record 39 calendar years (1986–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.9 ft × 13.0 ft × 5.6 ft
Registered tonnagegross 21 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMODUTECH MARINE, INC · TACOMA, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKODIAK, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 27 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC9144MMSI 367098150 · active · compulsorily equipped · granted 3 January 2026, expires 9 March 2036
WCX5455MMSI 366734910 · expired · voluntarily equipped · granted 17 June 1997, cancelled 19 August 2007 · licensed under a name not among this hull’s recorded names (not shown)
WCW3663MMSI not assigned · expired · compulsorily equipped · granted 26 March 1996, cancelled 27 May 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

27 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8356974
18 June 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8329436
26 June 2024 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7943031
27 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7725137
9 July 2022 Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7510592
21 June 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7483508
8 April 2022 Drydock Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7427563
19 August 2021 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7291784
2 June 2021 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7220821
11 September 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7058881
27 July 2019 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6792834
24 July 2019 Deficiency Check · Damage Survey · Drydock Exam · In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6792803
1 July 2019 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6732708
6 September 2018 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6534472
23 April 2018 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6398377
6 September 2017 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6262117
8 June 2016 COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 5899094
30 March 2016 Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 5851551
19 October 2015 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 5743478
17 October 2014 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 5032520
7 May 2012 Liferaft Servicing
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 4307857
5 August 2011 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 4106201
18 October 2010 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3870801
16 October 2008 MARPOL Annex V Examination · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3346352
4 October 2007 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3073966
18 April 2006 COI Inspection · Hull Examination · Internal Structural Exam · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2627775
10 June 2005 Re-Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2386580
6 April 2004 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2038779
26 June 2003 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 1827764
15 May 2003 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 1794151
30 April 2002 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 1622231
17 August 2001 Examination of Repairs · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1370193
6 May 2000 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1391291
28 January 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 815284
20 May 1999 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1375840
18 June 1998 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1129396
25 March 1998 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1129398
26 November 1997 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 761347
25 November 1997 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 208463
13 May 1997 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1368228
17 July 1996 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1088945
31 May 1996 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1191092
25 March 1996 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1077653
10 April 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1154148
10 March 1995 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360034
13 January 1995 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 865255
3 June 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1320461
3 May 1994 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1168400
11 March 1994 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1370795
17 December 1993 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1160097
5 March 1993 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1013119
24 June 1992 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1264902
6 March 1992 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1316809
11 April 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 902809
10 April 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 928908
22 March 1991 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1305939
13 April 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1233003
2 March 1990 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 899505
2 March 1989 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1199339
28 December 1988 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1346991
11 March 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1336375
1 July 1987 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1316668
27 March 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1327016
9 June 1986 Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 988441
28 February 1986 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1309249

Deficiency record · 75

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 June 2024 Resolved
Vessel shall have sufficient first aid in the event of a medical emergency. The Aspirin and Ammonia Inhalants in First Aid Kit are expired. Replace expired items.
Action required: 10 - Deficiency Rectified
Due 30 July 2024
Resolved 26 June 2024
Resolution: Replaced expired items.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2024 Resolved
Vessels must have emergency checkoff lists accessible to crew for rough weather, Man overboard, and Fire at sea. Vessel did not have emergency checkoff lists or instructions.
Action required: 10 - Deficiency Rectified
Due 26 July 2024
Resolved 26 June 2024
Resolution: Provided Emergency Instructions prior to completed inspection.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 June 2022 Resolved
Provision must be made for closing all supply duct cowls and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Vessel has no system designed specifically for closing ventilation, but has temporary system in place. 46 CFR 182.465 ((h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 9 July 2022
Resolution: Vessel has snap covers that can easily but put in place over engine room ventilation.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 21 June 2022 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Vessel's alternate master could not find his medical certificate. 46 CFR 10.301(a)
Action required: 10 - Deficiency Rectified
Due 21 July 2022
Resolved 22 June 2022
Resolution: Vessel secondary Master found and provided medical certificate.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 June 2022 Resolved
A vessel must carry up to date charts. Vessel's paper charts are out of date. 46 CFR 184.420 (a)(1)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 21 July 2022
Resolved 22 June 2022
Resolution: Vessel owner purchased new and updated charts.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 June 2022 Resolved
A vessel must carry up to date US Coast Pilot [name withheld] is out of date. 46 CFR 184.420 (a)(2)
Action required: 10 - Deficiency Rectified
Due 21 July 2022
Resolved 22 June 2022
Resolution: Vessel owner purchased new Coast Pilot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2022 Resolved
Connections must be made to battery terminals with permanent type connectors. Vessel has wing nuts for connectors. 46 CFR 183.370
Action required: 10 - Deficiency Rectified
Due 21 July 2022
Resolved 22 June 2022
Resolution: Permanent type connectors installed on batteries.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 June 2022 Resolved
A vessel must carry a first aid kit approved IAW 160.041 or equivalent. Vessel does not have aspirin on board. 46 CFR 184.710
Action required: 10 - Deficiency Rectified
Due 21 July 2022
Resolved 22 June 2022
Resolution: Vessel owner purchased new first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2022 Resolved
Where flexible fill pipe section is necessary, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Vessels fill pipes are not joined by a conductor. 46 CFR 182.445(g)
Action required: 10 - Deficiency Rectified
Due 21 July 2022
Resolved 22 June 2022
Resolution: Vessel owner bonded flexible hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 June 2021 Resolved
Fixed bilge system did not adequately move water from each required space. Make repairs and demonstrate proper operation to the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 3 June 2021
Resolution: Witnessed satisfactory operation of vessel's bilge pump.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 June 2021 Resolved
VHF Radio was not linked to DSC. Connect VHF radio to chart plotter to to display lat/long and MSSI #.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 3 June 2021
Resolution: VHF DSC connected to chart plotter and displaying lat/long and DSC.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 11 September 2020 Resolved
Alcohol test strips not onboard. Obtain and store 02 DOT approved alcohol test strips onboard the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2020
Resolved 15 September 2020
Resolution: Vessel obtained alcohol test strips
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2020 Resolved
Life ring water lights battery expired. Replace waterlight battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2020
Resolved 15 September 2020
Resolution: Battery replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 July 2019 Resolved
Vessel's starboard hull delaminated over a 16" x 30' section. Make permanent repairs, in accordance with an approved written repair proposal, to the satisfaction of an attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2020
Resolution: Vessel completed repairs to the satisfaction of attending Marine Inspector.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 18 October 2010 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 6 January 2011
Resolution: FCC Station License provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 18 October 2010 Resolved
Provide FCC Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 5 May 2011
Resolution: FCC Safety Radio Certificate provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 18 October 2010 Resolved
Provide FCC Marine Radio Operator Permit.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 5 May 2011
Resolution: FCC Marine Radio Operator Permit provided.
Communications › Radio Communications › EPIRB
Issued 18 October 2010 Resolved
Renew NOAA EPIRB registration.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 6 January 2011
Resolution: NOAA EPIRB registration renewed.
Electrical › Electrical Distribution System (service) › Switch
Issued 18 October 2010 Resolved
Blank off open circuit in AC switchboard.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 6 January 2011
Resolution: AC switchboard all SAT.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 October 2010 Resolved
Label high level alarms at operating station.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 6 January 2011
Resolution: High level alarms labeled.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 October 2010 Resolved
Provide emergency broadcast placard.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 6 January 2011
Resolution: Emergency broadcast placard posted.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 October 2010 Resolved
Provide emergency instructions.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 6 January 2011
Resolution: Emergency instructions posted.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 October 2010 Resolved
Provide 3-6 feet lanyard, securing the waterlight around the body of the ring life buoy.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 6 January 2011
Resolution: Lanyard provided on ring life buoy.
Stability › Watertight Integrity › General
Issued 18 October 2010 Resolved
Provide latching device to weather-exposed watertight hatch covers.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 6 January 2011
Resolution: Latching devices installed.
Engineering › Bilge Water Management System › Not Operational
Issued 18 October 2010 Resolved
Prove proper operation of fixed bilge system. **PTCP**
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 5 May 2011
Resolution: Tested bilge system - all SAT.
Accommodation/Occupational Safety › Heating › Heating Fuel
Issued 16 October 2008 Resolved
Owner had recently installed a small toyo 12v diesel fired heater in the passenger cabin. The fuel tank for the vessel was placed in an aluminum cradle on top of the passenger cabin. The fuel tank is a plastic tank. Required owner to install an ABYC or CFR approved fuel tank.
Action required: 705 - Other - as specified
Due 16 April 2010
Resolved 18 October 2010
Resolution: Plastic fuel tank removed from vessel.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 10 June 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2005
Resolved 29 August 2005
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 June 2005 Resolved
Eight PFD's were condemned by inspector for holes in the heat sealed bags containing fibrous glass. Need five adult and two child PFD's.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2005
Resolved 29 August 2005
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 10 June 2005 Resolved
Current coast pilot, light list and tide tables are required.
Due 30 June 2005
Resolved 29 August 2005
Engineering › Sea-water System (primary cooling)
Issued 9 April 2004 Resolved
Existing FRP wet exhaust was removed by owner/operator and replaced with PVC pipe. This installation in not in accordance with 46 CFR 182.710 (a) 6. Owner/operator cites letter from engine manufacturer allowing installation and will appeal. LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2004
Resolution: Viewed installation of engine manufacturer recommended FRP wet exhaust
Personnel › Certificates/Documents/Licenses
Issued 6 April 2004 Resolved
Owner Operator is required to maintain CPR qualification for employment on CG Base, but has lost certificate. He will renew certificate & present to inspector LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Due 12 June 2004
Resolved 24 May 2004
Personnel › Certificates/Documents/Licenses
Issued 6 April 2004 Resolved
Owner/operator will complete course and present First Aid card to inspector LEGACY COMPONENT DESC: Certificate, First Aid Course Completion
Due 12 June 2004
Resolved 24 May 2004
Navigation › Piloting/Steering
Issued 6 April 2004 Resolved
Provide tidal current information for area of operation LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 12 June 2004
Resolved 25 May 2004
Lifesaving › Lifejacket/PFD (General)
Issued 6 April 2004 Resolved
Label Child-size PFD storage locker LEGACY COMPONENT DESC: Storage
Due 12 June 2004
Resolved 25 May 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 May 2003 Resolved
Condemned 9 adult PFD's (kapok/fiberous glass style) for multiple leaks in plastic inserts. Owner provided new PFD's to replace within the same day.
Condition: Unknown
Due 30 May 2003
Resolved 30 May 2003
Documentation › Certificates/Documents
Issued 15 May 2003 Resolved
Owner did not have current COD on board. Owner stated that he received renewal notification and returned it to VDOC center, but has not received his new COD. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 30 June 2003
Resolved 18 June 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 30 April 2002 Resolved
MAKE PERMANENT REPAIR TO PORT AND STBD WET EXHAUST PIPES AT STERN WHERE FRP IS LEAKING. EFFECT TEMPORARY REPAIRS NOW AND CLEAR PERMANENT NO LATER THAN 15JUN02. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 14 June 2002
Fire Fighting
Issued 20 May 1999 Resolved
INSTALL FIRE CONTROL AND DETECTION SYSTEMS IN ACCORDANCE WITH 46CFR.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Lifesaving
Issued 20 May 1999 Resolved
PROVIDE 5 REPAIRED OR REPLACED PFD'S. LIMITED TO TOTAL OF 17 TOTAL ADULT CREW AND PASSENGERS COMBINED UNTIL CLEARED. MUST HAVE ONE CHILD'S JACKET FOR EACH CHILD ONBOARD.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Lifesaving
Issued 13 May 1997 Resolved
OBTAIN NEW IN-DATE FLARES.
Condition: Unknown
Due 13 June 1997
Resolved 21 August 1997
Lifesaving
Issued 13 May 1997 Resolved
REPLACE RETRO TAPE ON PFD'S AS DIRECTED.
Condition: Unknown
Due 13 June 1997
Resolved 21 August 1997
Navigation
Issued 13 May 1997 Resolved
OBTAIN UPDATED NAV PUBS FOR WHEELHOUSE.
Condition: Unknown
Due 13 June 1997
Resolved 21 August 1997
Navigation
Issued 13 May 1997 Resolved
OBTAIN SHIP'S BELL AND ANCHOR BALL.
Condition: Unknown
Due 13 June 1997
Resolved 21 August 1997
Documentation
Issued 31 May 1996 Resolved
PROVIDE ON BOARD AND POST VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Engineering
Issued 31 May 1996 Resolved
REPAIR EXCESSIVE LEAK ON STARBOARD SHAFT.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
REPLACE OUTDATED BATTERY FOR EPIRB.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
REMOVE PLASTIC BAGS FROM ALL LIFE PRESERVERS.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
PROVE PROPER OPERATION OF EPIRB.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Documentation
Issued 31 May 1996 Resolved
PROVIDE ON BOARD AND POST CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
CLEAN UP AND PROVE PROPER CLOSURE OF SNAPS ON 15 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Fire Fighting
Issued 31 May 1996 Resolved
PROVIDE ADDITIONAL BII FIRE EXTINGUISHER IN BRACKET OR ADDITIONAL BI FIRE EXTINGUISHER IN PROPER BRACKET.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Fire Fighting
Issued 31 May 1996 Resolved
INSTALL CORRECT SIZE BRACKET FOR BI FIRE EXTINGUISHER AFT IN CABIN.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
MARK LOCATION OF ALL STOWAGE OF LIFE PRESERVERS.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Documentation
Issued 31 May 1996 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING FOR CREW.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Construction/Loadline
Issued 31 May 1996 Resolved
REPAIR HINGE ON STARBOARD ENGINE ROOM HATCH.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Construction/Loadline
Issued 31 May 1996 Resolved
ATTACH SECURING DEVICE FROM LAZARETTE HATCH TO VESSEL.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
PROVIDE PROOF OF LIFE FLOAT CAPACITY AND MARK ACCORDINGLY ON LIFE FLOAT.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
ATTACH PAINTER TO WEAK LINK.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
PROVIDE ADDITIONAL WEAK LINK OR INSTALL CORRECT SIZE WEAK LINK FOR BOTH LIFE FLOATS.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
PROVIDE THREE ADDITIONAL ADULT LIFE PRESERVERS. PASSENGERS REDUCED TO 15 AND TOTAL PERSONS ALLOWED REDUCED TO 19 WITH 12 HOUR CLAUSE ALLOWING 17 PASSENGERS UNTIL ADDITIONAL PFD'S PROVIDED.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Lifesaving
Issued 31 May 1996 Resolved
PROVIDE 60' LINE AND ATTACH TO RING BUOY.
Condition: Unknown
Due 31 May 1996
Resolved 14 June 1996
Construction/Loadline
Issued 25 March 1996 Resolved
CROP OUT AND RENEW ROTTED PLYWOOD AND FRAME UNDER FRP DECK IN FORWARD LAZARETTE OVERHEAD WITH MARINE PLYWOOD AND TREATED WOOD.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Construction/Loadline
Issued 25 March 1996 Resolved
REPLACE 1 1/2 PVC NIPPLE AND BRASS CAP WITH 1 1/2 PLUG PORT SIDE FORWARD INENGINE ROOM ABOVE WATERLINE.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Construction/Loadline
Issued 25 March 1996 Resolved
CROP OUT AND RENEW ROTTED WOOD UNDER FRP DECK AFT OF ENGINE ROOM HATCHES WITH TREATED WOOD.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Construction/Loadline
Issued 25 March 1996 Resolved
INSTALL INSPECTION DECK PLATE ON MAIN DECK TO ALLOW ADEQUATE INSPECTION OF FOREPEAK. PLATE TO BE AT LEAST 6 INCHES.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Lifesaving
Issued 10 March 1995 Resolved
REPLACE SIX HAND FLARES WITH SIX ORANGE SMOKE FLARES.
Condition: Unknown
Due 19 March 1995
Resolved 19 March 1995
Lifesaving
Issued 10 March 1995 Resolved
REPLACE WEAK LINKS FOR BOTH LIFE FLOATS.
Condition: Unknown
Due 19 March 1995
Resolved 19 March 1995
Electrical
Issued 10 March 1995 Resolved
BATTERY BOXES MUST BE LINED WITH FIBER GLASS OR LEAD IAW 46 CFR 183.05-20.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Navigation
Issued 11 March 1994 Resolved
DEVIATION TABLE FOR MAGNETIC COMPASS NEEDS RENEWAL.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Navigation
Issued 11 March 1994 Resolved
NEED TO PROVIDE RADIO-TELEPHONY CERTIFICATE AS OUTLINED IN 47 CFR 80.903.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Engineering
Issued 11 March 1994 Resolved
WEAR PLATE NEEDS TO INSTALLED BETWEEN TRANSMISSION AND HULL.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Electrical
Issued 11 March 1994 Resolved
NEED TO PROVIDE WIRING SCHEMATIC FOR SHORE TIE DISTRIBUTION PANEL. (LINE DRAWING)
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Electrical
Issued 11 March 1994 Resolved
NEED TO REPAIR WIRING FOR WASHDOWN PUMP IN LAZARRETTE.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Engineering
Issued 22 March 1991 Resolved
PROVE PROPER OPERATION OF MAIN ENGINE AHEAD AND ASTERN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Documentation
Issued 22 March 1991 Resolved
PROVIDE VALID MARINE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991

Casualty record · 1

27 July 2019Routine · role: Involved in a Marine Casualty · activity 6792834
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record