← All vessels
CAPT. JEFF
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named CAPT. JEFF
CAPT. JEFF is a 1977 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1985, most recently in August 2025, along with 264 deficiencies — 2 with no resolution recorded — and 1 casualty investigation in 2025.
Records from 1985 to 2025. Most recent: inspection, 7 August 2025.
- Built
- 1977
- Last inspected
- 7 August 2025
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 264 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2025
Identity
580321
WDN8473
49087
Flag
UNITED STATES
368317890
Maury page id
psix-49087
Inspections, by type
…with no type recorded4
Years with a record
34 calendar years (1985–2025)
The 74 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)59.1 ft × 19.6 ft × 5.7 ft
Registered tonnagegross 53 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILL'S BOAT WORKS · HARKERS ISLAND, NC, UNITED STATES · built 1977
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Regulatory (Subpart C or D), Gross Ton
36 - Regulatory (Subpart C or D), Net Ton
36 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN8473MMSI 368317890 · active · compulsorily equipped · granted 3 June 2023, expires 3 June 2033
WDG6414MMSI 367556720 · expired · compulsorily equipped · granted 19 December 2012, cancelled 18 February 2023 · licensed under a name not among this hull’s recorded names (not shown)
WDA9988MMSI 366871130 · expired · compulsorily equipped · granted 8 October 2002, cancelled 8 December 2012 · licensed under a name not among this hull’s recorded names (not shown)
WCW6112MMSI not assigned · expired · compulsorily equipped · granted 28 May 1996, cancelled 29 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 74
7 August 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8204288
7 August 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8208979
27 March 2025
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8100166
13 March 2025
Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8093504
10 January 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8060771
18 March 2024
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7879788
3 July 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7730472
14 April 2023
COI Inspection · Deficiency Check · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7668679
10 September 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6808110
4 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6803525
2 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6364820
15 November 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6293240
28 September 2017
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6276829
2 November 2016
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6033716
21 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5837629
21 October 2015
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5747570
26 March 2014
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4823184
17 November 2010
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3868324
9 March 2010
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3661860
24 November 2008
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3368281
20 March 2008
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3168082
21 November 2007
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3102143
11 April 2006
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2621821
13 March 2006
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2604281
8 March 2005
Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2304800
14 April 2004
MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2040108
17 March 2004
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2024730
27 March 2003
Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1763851
17 October 2002
Administrative Inspection
Administrative · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1691453
22 April 2002
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1607659
9 April 2002
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1602852
25 January 2002
COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1482532
3 May 2001
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1452801
27 April 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1401459
25 October 2000
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1379212
4 October 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 823457
2 May 2000
Deficiency Check · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 820555
24 September 1999
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1393239
14 May 1999
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 795745
10 March 1999
COI Inspection · Plan Review "T" Boat
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1408268
7 December 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1390892
12 May 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 791076
27 April 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 790183
20 April 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1398883
21 November 1997
Plan Review "T" Boat · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1368500
3 July 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 777636
3 July 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1113226
3 June 1997
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1392703
2 October 1996
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 837132
21 May 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1085968
25 April 1996
COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1388017
23 April 1996
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1080369
27 March 1995
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1353722
8 June 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1321527
26 May 1993
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1432695
31 March 1993
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 838393
28 April 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1256268
2 July 1991
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 934379
5 June 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 930556
2 May 1991
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 928282
14 March 1990
Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 916070
2 August 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1344164
26 April 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1199835
7 November 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1202672
20 July 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1343238
9 June 1988
Hull Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 890143
5 February 1988
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017956
11 May 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1335621
11 May 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1335746
2 May 1986
Deficiency Check · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1308640
18 February 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1298905
25 November 1985
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 996031
13 November 1985
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 993867
19 August 1985
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 992885
Deficiency record · 264
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 August 2025
Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given
to the provision of a seaworthy hull. Vessel operator reported taking on significant amount of water through Engine Exhaust connections and partially sunk. Provide salvage plan and repair proposal satisfactory to attending Marine Inspector prior to vessel movement.
46 CFR 177.01-5 (OLD T)
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 August 2025
No resolution recorded
The intent of this part is to ensure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given to the provision of a seaworthy hull. Vessel operator reported taking on significant amount of water through Engine Exhaust connections and partially sunk. Vessel conducted repairs in repair plan and have made themselves ready to be towed. Vessel is authorized one time passage to be towed to Paradise Marina .
46 CFR 177.01-5 (OLD T)
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 March 2025
Resolved
"The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate... the recovery of persons who have fallen overboard." Vessel did not demonstrate satisfactory arrangement for recovering persons from the water. Carry out a drill with a satisfactory arrangement in the presence of a Marine Inspector.
46 CFR 185.520(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 March 2025
Resolved
"Gauges to indicate... jacket water discharge temperature... must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station." Jacket water gauge on the bridge was found inoperable. Repair gauge.
46 CFR 182.410(b)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 March 2025
Resolved
"All vessels... shall be provided with suitable steering apparatus." Port side rudder packing was found leaking. Repair rudder packing to ensure no leaking while vessel is operating.
46 CFR 182.30-1(a) (OLD T)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 March 2025
Resolved
"The lights prescribed by these Rules shall, if carried, also be exhibited from sunrise to sunset in restricted visibility and may be exhibited in all other circumstances when it is deemed necessary." Forward masthead light was found inoperable. Fix light.
33 CFR 83.20(c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2025
Resolved
"When the flexible section is a nondoncutor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling." Fuel pipe was observed with bonding not fixed.
46 CFR 182.20-30(d) (OLD T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2025
Resolved
"All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a)." Vessel did not have required portable hand pump onboard. Obtain portable hand pump.
46 CFR 82.25-10(a) (OLD T)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 March 2025
No resolution recorded
"A summary of survival craft requirements is provided in Table 180.200(c)." Vessel has 02 lifefloats that can accomodate a total of 44 POB. Prior to operations in cold water, operator must provide 100% primary lifesaving appliances.
46 CFR 180.200(c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2025
Resolved
Port engine has a damaged fuel line and the generator, in the engine room, has unapproved fuel line installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 March 2025
Resolved
Guards missing on rotating amchinery in the engine room on the Generator and both engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2025
Resolved
Lighting system in the engine room is wired using houshold romex cable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 March 2025
Resolved
Leak on the Port Engine raw water injector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 March 2025
Resolved
Port engine has a exhaust cooling water leak, aft inboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 March 2025
Resolved
Starboard Lazarette generator exhaust Leak.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 March 2025
Resolved
Fuel line in the engine room going forward is very loose, needs to be secured.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 January 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years... Vessel lapsed required DDX inspection date of 31Dec2024. Make vessel ready for drydock examination. Prior to the carriage of passengers, vessel must receive credit drydock.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 18 March 2024
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners… IDENTIFIED CAPTAIN TO BE WITHOUT A MEDICAL CERTIFICATE.
46 CFR 10.301
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 March 2024
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by non-combustible hangers or blocks. IDENTIFIED EXHAUST LEAK FROM TANK VOID.
46 CFR 182.430(b)
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 March 2024
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. VESSEL IS TAKING ON WATER ON LAZARETTE AND STEM. WATER EGRESS PORT SIDE STEM OBSERVED UNDER WAY. LAZARETTE WATER EGRESS APPEARS TO BE FROM RUDDER PACKING GLAND. PROVIDE REPAIR PLAN TO COAST GUARD.
46 CFR 177.10-1 OLD T
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 March 2024
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. PORT SIDE AFT VERTICAL STANCHION THAT SUPPORTS UPPER DECK SHOWS SIGN OF ROT WHERE IT PENETRATES MAIN DECK PROVIDE REPAIR PLAN.
46 CFR 177.10-1 OLD T
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 18 March 2024
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. IDENTIFIED SOFT SPOTS ON UPPER DECK. PASSENGERS RESTRICTED FROM ACCESS TO UPPER DECK.
46 CFR 177.10-1 OLD T
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2024
Resolved
The intent of this part is to ensure that the main propulsion machinery installed on each vessel is suitable for the purpose intended… IDENTIFIED BOTH STARBOARD AND PORT MAIN ENGINE TO HAVE OIL LEAKING. PROVIDE PLAN TO STOP LEAKING.
46 CFR 182.01-5 OLD T
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 March 2024
Resolved
Each survival craft required on a vessel by this part must meet one of the following… IDENTIFIED MISSING 01 LIFE FLOAT. RESTRICTED TO 44 PASSENGER IN COLD WATER CONDITIONS.
46 CFR 180.200
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 March 2024
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. PORT AND STARBOARD LONGITUDIAL UPPER DECK SUPPORTS ARE ROTTED AT AFT ENDS. PROVIDE REPAIR PLANS.
46 CFR 177.10-1 OLD T
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer In Charge, Marine Inspections. FORWARD GENERATOR SPACE (2ND VOID) REMOVE POWER STRIP THAT IS LOOPED AROUND EXHAUST.
46 CFR 183.01-15 OLD T
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer In Charge, Marine Inspections. CONDUIT AT STARBOARD SIDE ENGINE ROOM ATTACHED TO LIGHTING FIXTURE IS INOPERABLE. REPAIR AND PROPERLY SUPPORT.
46 CFR 183.01-15 OLD T
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 18 March 2024
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. TRANSVERSE DECK BEAMS AND DECK FASTENERS AT STARBOARD SIDE, OUTBOARD OF ENGINE NEEDS TO BE REPLACED. PROVIDED REPAIR PLAN.
46 CFR 177.10-1 OLD T
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 March 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection… PROVIDE COAST GUARD WITH EVIDENCE OF DAPI ENROLLMENT FOR NEW HIRES.
46 CFR 16.230
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 March 2024
Resolved
Vessels shall be equipped with a suitable number of portable battery lights. IDENTIFIED NONE ON VESSEL.
46 CFR 184.30-1 (OLD T)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock… IDENTIFIED DEAD END WIRING UNDERNEATH HELM AND BEHIND GENERATOR IN ENGINE ROOM LEADING INTO THE BILGE.
46 CFR 183.200
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. IDENTIFIED THAT THE ENGINE ROOM AUTOMATIC BILGE PUMPS WERE NOT OPERABLE.
46 CFR 182.530
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 March 2024
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. IDENTIFIED NO LOGS. PROVIDE COAST GUARD WITH EPIRB MONTHLY TEST LOGS AS WELL AS ABANDON SHIP, FIRE, AND MAN OVERBOARD DRILL LOGS.
46 CFR 185.728
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. IDENTIFIED NO EMERGENCY INSTRUCTIONS POSTED AT OPERATING STATION.
46 CFR 185.510
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 March 2024
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. IDENTIFIED MISSING GUARD ON LIGHTS IN TANK VOID, PORT DOOR NEXT TO PILOT HOUSE, AND NEAR STARBOARD ENGINE.
46 CFR 183.410
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 March 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. IDENTIFIED INADEQUATE GUARD ON GENERATOR IN ENGINE ROOM. MAKE BETTER EXISTING GUARD.
46 CFR 177.960
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 18 March 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines… IDENTIFIED PORT REACH ROD FOR FUEL SHUTOFF IN NEED OF SERVICING.
46 CFR 182.20-40 (b)
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 March 2024
Resolved
Installation shall be in accordance with 182.15-15. IDENTIFIED EXPOSED EXHAUST ON STARBOARD ENGINE. OUTFIT EXHAUST PIPING WITH PROPER INSULATION.
46 CFR 182.20-15 OLD T
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 March 2024
Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. IDENTIFIED IN PILOT HOUSE THAT PORT TEMPERATURE GAUGE IS INOPERABLE. Updated def- extended another 14 days gauge has been ordered. 15APR2024
46 CFR 182.20-5 OLD T
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 March 2024
Resolved
The rules concerning lights shall be complied with from sunset to sunrise, and during such times no other lights shall be exhibited… IDENTIFIED PORT LIGHTS NOT WORKING. CORRECTED ON THE SPOT.
33 CFR 83.20
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer In Charge, Marine Inspections. IDENTIFIED LOOSE CONNECTION ON STARTING WIRE TO SOLENOID ON STARBOARD ENGINE. CORRECTED ON SITE.
46 CFR 183.01-15 OLD T
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 July 2023
Resolved
Vessel has weeping at the bow stem, void #2 stbd side rot lwr plank as marked, weeping in the fuel tank space at the chine, and in the laz void. Must keep a log of all water disposal and vessel will be put on a one year DD cycle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 July 2023
Resolved
Vessel has water leaking from both P&S MDE exhaust, must repair to new condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 July 2023
Resolved
Vessel has major exhaust leak in the tank space setting off inspectors meter, must repair to new condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2023
Resolved
Vessel has a hydraulic leak in the Laz on the steering ram, must repair to new condition.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 July 2023
Resolved
Vessel has no ventilation closures for engine room (4); the space is protected by CO2 and must be vaportight. Temp closures are approved until 10JUL2023 (1 week).
46 CFR 181.20-35 (OLD T)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 July 2023
Resolved
All bilges have 6 inches of water, debris, rags, paint chips, and engine room bilge has oil. All bilges must be clean & dry prior to next inspection on 10JUL2023, while underway.
46 CFR 182.25-1 (OLD T)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 July 2023
Resolved
Starboard rudder has an excessive leak, must add packing to control water flow.
46 CFR 182.30-1 (OLD T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 July 2023
Resolved
Both starboard and port engines have oil leakin gfom head gasket and exhaust manifold gasket. Must provide a maintenance plan and conduct repairs to stop oil from entering the bilges.
46 CFR 182.01-5 (OLD T)
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 24 April 2023
Resolved
Each Vessel must have a Stability Letter issued by the Coast Guard. Stability Letter not on board the vessel.
OLD T 46 CFR 170.120
OLD T 46 CFR 185.12-1(a
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2023
Resolved
Fixed Hand Bilge pump shall be permanently connected to the bilge main. Vessel shall provide satisfactory arrangement for draining any watertight compartment. Vessel has no way of adequately draining the bilges.
OLD T 46 CFR 182.25-25-1(d)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 April 2023
Resolved
A life float approved under 160.027 may be used to meet the requirements of this part. Vessel did not have the correct number to accommodate all persons on board the vessel for its intended route.
46 CFR 180.200(a)(2)
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 24 April 2023
Resolved
There must be an individual holding an appropriate license. Master could not provide license during inspection.
46 CFR 15.805(a)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 April 2023
Resolved
Fixed Fire Extinguishing System must be installed in compliance with 181.410. CO2 cylinders/flexible connections require hydro or renewal. Marine Inspector shall be provided servicing report of final servicing of the system when completed.
46 CFR 181.410
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2023
Resolved
Vessels constructed of wood must be provided bilge high level alarms in all watertight compartments. Hold #4 bilge alarm was displaying a fault on the panel.
46 CFR 182.530
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2023
Resolved
Minimum number of portable fire extinguishers required on board each vessel shall be determined by the OCMI in accordance with Table 181.30-1(a). Extinguishers were not properly maintained, extinguishers/brackets were wasted and worn and past service life.
OLD T 46 CFR 181.30-1(a)
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 April 2023
Resolved
Each vessel that operates on the high sea must have an EPIRB. Vessel's EPIRB was not available for inspection.
46 CFR 180.64
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 April 2023
Resolved
Vessels name shall be affixed on each side of the port and starboard bow and on the stern in letter no less than 4".
46 CFR 67.123
OLD T 46 CFR 185.30-1
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 April 2023
Resolved
Vessels Navigation light configuration was incorrect. Vessel is required 1 (225 degree) masthead light and running lights with proper visibility.
33 CFR 83.23(a)
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 April 2023
Resolved
Vessel is required an illuminated magnetic compass. Compass was off by 40 degrees and deemed unsafe for it's intended service.
OLD T 46 CFR 184.20-1
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 24 April 2023
Resolved
FCC Permit, certification & FCC station license must be on board. Vessel radio's could not be tested nor verified in compliance with the FCC as 1 was deemed inoperable. Antenna wires were found severed.
47 CFR 80.13
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2023
Resolved
Vessel required 1 Ring Life Buoy. Vessel's ring buoy shall be marked with vessel's name, have throw line (60') attached tot he body of the buoy and the water light with lanyard (3-6') attached with corrosion clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2023
Resolved
TYPE I Life Jackets are required to be carried of adequate size for all persons on board. Many life jackets were deemed not adequate for service. Life preservers must be marked and have Retro reflective material attached per IMO Res. A.658.(16)
46 CFR 185.604
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 24 April 2023
Resolved
Vessel is required to implement a drug program. Alcohol test swabs were not on board during inspection. A DAPI program Audit must be completed prior to certification.
46 CFR 16.205
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 24 April 2023
Resolved
Vessel must carry an approved First Aid Kit. Fist Aid Kit currently on board does not meet USCG Approval requirement.
46 CFR 184.710
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 April 2023
Resolved
Maximum number of passengers permitted shall be determined by the [name withheld] upper deck was set to 17, however MI's question the available space determined by adequate passenger count criteria. pends.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 April 2023
Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers. Upper Port side rail is loose and insufficient in meeting an anticipated point load.
OLD T 177.35-19(a)
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 April 2023
Resolved
Suitable covers guards or rails shall be installed in way of all hazardous places such as gear, machinery. 271 Detroit genset has no guards around rotating machinery.
OLD T 177-.35-15
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 24 April 2023
Resolved
Vessels shall be fitted with such ground tackle (anchor) as deemed necessary by the [name withheld] chain missing and Danforth anchor deemed undersized for the size of the vessel.
OLD T 184.10-1(a)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 April 2023
Resolved
Gages to indicate...lubricating oil pressure for all propulsion engines shall be provided and be in view of the operator. MDE pressure gage line disconnected and crimped using vice grips.
OLD T 182.20-5(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023
Resolved
All machinery essential to the routine operation of the vessel shall be checked. During the inspection raw water intake pipe for the generator was found leaking.
OLD T 46 CFR 176.25-10(a)(4)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
Installations and equipment accepted by the Coast Guard as meeting the applicable requirements ...and which are maintained in serviceable condition to the satisfaction of the [name withheld] wiring was found on the aft deck junction box and conduit terminating on the aft deck.
OLD J 46 CFR 111.05-1(c)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 April 2023
Resolved
At each inspection the marine inspector shall examine and test main and auxiliary steering systems. Steering system was not made available for test during inspection
OLD T 176.25-35
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 April 2023
Resolved
It shall be the duty of the master of any vessel to provide the following: emergency instructions/safety orientation/emergency check off lists/man overboard & recovery procedures/Fire at sea/EPIRB checks.
OLD T 185.25-1(a)
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 24 April 2023
Resolved
The master shall conduct drills and give instructions as necessary to ensure that the crew members are familiar with their duties. No drill records provided.
OLD T 185.25-10
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 24 April 2023
Resolved
Rails or equivalent protection shall be installed to all areas accessible to passengers. Forward access ladder to the second deck was loose/rotten and missing hardware.
OLD T 177.35-1(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2023
Resolved
Shutoff valves, installed so as to close against the flow of fuel...the shutoff valve at the tank shall be operable from a space outside the tank compartment. Fuels shut off valve not properly fitted.
OLD T 182.20-40(b)(3)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
Electrical equipment should be so placed or protected as to minimize the possibility of mechanical injury or damage. Owner shall secure/remove all dead end wires throughout the vessel.
OLD J 46 CFR 111.05-15(a)(3)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023
Resolved
A Cable may be spliced under the following conditions. Wire Splice in electrical locker port side in galley, identify the circuit, make proper wire splice.
OLD J 46 CFR 111.80-35(a)(b)(c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2023
Resolved
Electrical equipment shall be installed to the satisfaction of the OCMI. Vessel is using extension cords throughout the vessel. Remove as appropriate.
OLD T 46 CFR 183.01-15(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
An ammeter that is readily visible shall be included in the battery charger circuit. Replace battery chargers
throughout the vessel. Chargers require an ammeter.
OLD T 46 CFR 183.05-20(f)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
Fixture globes shall be protected by guards. All light
fixtures throughout the vessel missing globe/guards.
OLD J 46 CFR 111.75-20(a)(3)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
Electrical equipment shall be installed to the satisfaction of the [name withheld] outlets and switches are without covers causing electrical hazard.
OLD T 46 CFR 183.01-15(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
Electrical equipment shall be installed to the satisfaction of the [name withheld] shall identify switch button in port side electrical locker.
OLD T 46 CFR 183.01-15(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
Batteries shall be so located to be as high as practical and secured against shifting. Loose battery found in engine room, remove or secure.
OLD T 46 CFR 183.05-20(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023
Resolved
A Cable may be spliced under the following conditions. Wire Splice on water pump in forward generator void is inadequate, cable material is an extension cord.
OLD J 46 CFR 111.80-35(a)(b)(c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2023
Resolved
Electrical equipment shall be installed to the satisfaction of the [name withheld] battery lead at battery lug on forward engine room port side & loose wire on battery lug on the starboard side engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023
Resolved
Electrical equipment shall be installed to the satisfaction of the [name withheld] solenoids not mounted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
Electrical equipment shall be installed to the satisfaction of the [name withheld] starter switch on the generator is wired with clips and is unmounted.
OLD T 46 CFR 183.01-15(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023
Resolved
Diesel engine exhaust installation requirements. Exhaust tubing on forward generator needs to be properly support throughout its length.
OLD T 46 CFR 183.20-20
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023
Resolved
Auxiliary machinery shall be suitable in type and design for its intended purpose. Emergency stop on the forward generator cable is wired to the air flab control lever.
OLD T 46 CFR 182.10-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023
Resolved
Auxiliary machinery shall be suitable in type and design for its intended purpose. Raw water cooling hose on the forward generator is damaged and needs renewal.
OLD T 46 CFR 182.10-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023
Resolved
Auxiliary machinery shall be suitable in type and design for its intended purpose. Pulley belt is in poor condition and requires renewal.
OLD T 46 CFR 182.10-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2023
Resolved
Propulsion machinery shall be suitable in type and design for its intended purpose. Air shut off valves, wired to the emergency stops are inoperable on both MDEs
OLD T 46 CFR 182.05-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2023
Resolved
Propulsion machinery shall be suitable in type and design, port MDE Morse trnasmission cable needs replace.
OLD T 46 CFR 182.05-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2023
Resolved
Propulsion machinery shall be suitable in type and design for its intended purpose. Cooling water crossover valve on the stbd MDE requires renewal.
OLD T 46 CFR 182.05-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2023
Resolved
Flexible hose may be used. Fuel line routed over the stbd MDE. Re-route as appropriate.
OLD T 46 CFR 182.20-40
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2023
Resolved
Flexible hose may be used. Fuel line between the first and second fuel filter for the generator is unrated hose
OLD T 46 CFR 182.20-40
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2023
Resolved
Fuel lines.shall be effectively secured against excessive movement. During inspection a kinked fuel line at the forward bulkhead penetration was identified.
OLD T 46 CFR 182.20-40(b)(2)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 April 2023
Resolved
At subsequent inspections for certification all accessible part of the exterior and interior of the hull shall be examined. Owner/Operator to secure make watertight bulkhead penetrations watertight. Secure make watertight engine room bulkhead watertight. Make all openings in the hull of the vessel watertight.
OLD T 46 CFR 176.25-5(a)(1)
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 15 November 2017
Resolved
Provide each new PFD with TYPE I retro reflective material. 46CFR185.604(h)
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 15 November 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Steering Gear System › Rudder Stock
Issued 2 November 2016
Resolved
Repair/tighten packing on rudder posts. Cleared on the spot
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 November 2016
Resolved
repair hydraulic fluid leak on steering arm in Laz.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 November 2016
Resolved
Provide 2 more adult PFD's (Pax count reduced, total persons =79). Cleared on the spot.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2016
Resolved
Provide new line for waterlight attached to RLB (3'-6' in length). Corrected on the spot.
Lifesaving › Lifefloat › Paddle
Issued 2 November 2016
Resolved
Provide 2 labeled paddles for 8 person lifefloat. Corrected on the spot.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 2 November 2016
Resolved
Provide 2 flashlights. 1 at operating station and one at entrance to engine compartment. (have one, need 2) Cleared on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 November 2016
Resolved
remove dead end wiring in engine room.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 November 2016
Resolved
Provide new battery box for 12volt batterin in fwd engine room (current one has no bottom.)
Communications › Radio Communications › VHF Radiotelephone
Issued 2 November 2016
Resolved
Update MMSI# into VHF/DSC capable radio.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 November 2016
Resolved
provide updated Coast Pilot for area of operation.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 November 2016
Resolved
Replace Light Guards on 1 port side accom space, and 1 port side operating station.
Stability › Weathertight Integrity › General
Issued 2 November 2016
Resolved
Replace broken window in port side accom space.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 2 November 2016
Resolved
Provide 2015 MIS report.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 2 November 2016
Resolved
Provide proof of DOT 5panel testing (provide last random)
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 2 November 2016
Resolved
Provide results for a pre-employment test.
Engineering › Sea-water System (primary cooling) › Valve
Issued 21 March 2016
Resolved
A worklist item was issued to replace the port MDE SW cooling spool piece block.
Engineering › Steering Gear System › Rudder Stock
Issued 21 October 2015
Resolved
leaking rudder post, tighten seals
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 October 2015
Resolved
Pay user fee
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 November 2010
Resolved
Repair mounts for main engine starting battery disconnect switch.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 17 November 2010
Resolved
Install overcurrent protection within 7" of each end of the DC + conductor connecting the battery charger to the engine starting batteries. The battery end of the conductor shall be connected to the battery at the main disconnect switch end of the + battery cable.
Electrical › Electric Supply System (service) › Cable
Issued 17 November 2010
Resolved
The battery charger at the port forward end of the engine space is rated for 30 amps maximum output. This requires a minimum 10 awg conductor. The conductor in use is only a 12 awg. Replace the conductor with the proper size and insure overcurrent protection provided and the wire is properly secured.
Electrical › Electrical Distribution System (service) › Conductor
Issued 17 November 2010
Resolved
All wiring in the machine spaces must be secured in place with insulated metallic wiring clamps.
Construction/Loadline › Hull › Stiffener
Issued 17 November 2010
Resolved
Conduct an examination of all the vertical frames penetrating the maindeck IWO the bulwarks. Submit a maintenance and repair plan to correct water leaks, renew any rotted wood and to dry and seal the penetration areas thru the deck.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 17 November 2010
Resolved
Secure the loose port fuel tank vent IWO the maindeck penetration and seal the deck penetration to prevent water entry thru the deck.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 November 2010
Resolved
Seal wiring penetration of engine room fwd bhd IWO the "GUEST" battery charge output cable.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 November 2010
Resolved
Insure all expired materials are removed from service and replaced w/ currently dated materials.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 November 2010
Resolved
Complete the servicing of the fixed fire extinguishing and detection system. Present a copy of the service report from the service company.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 November 2010
Resolved
Repair and prove operation of the high water alarm in the lazzerette.
Electrical › Electrical Distribution System (service) › Conductor
Issued 17 November 2010
Resolved
Secure loose wiring in fwd generator space. All Machine space wiring shall be secured in place w/ insulated metallic wiring clamps
Electrical › Electric Generation Source (service) › Generator Cable
Issued 17 November 2010
Resolved
The wiring connected the forward generator to the control system and monitor panel is hanging loose supported only by the ring-eyes crimped on the end of the wires. A proper strain relieve and wiring clamps are needed.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 9 March 2010
Resolved
Clean and examine stop valve in the equalizing piping between the port & stbd fuel tank. Determine the cause of the fuel leak and repair or replace valve and associated piping as necessary to stop the leak.
Engineering › Sea-water System (primary cooling) › Valve
Issued 9 March 2010
Resolved
Open, clean and lap surfaces if machinist determines necessary both the PMDE & SMDE sea suction plug cock valve.
To be completed prior to launching the vessel.
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 March 2010
Resolved
Renew as original the framing for the stbd engine hatch. The underdeck beam on the outboard side of the hatch is wasted.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 March 2010
Resolved
Complete repairs to collision BHD. Recently replaced plywood sections need to be made watertight. Fit w/ adequate battens and caulking.
Engineering › Bilge Water Management System › Hose
Issued 9 March 2010
Resolved
Replace corrugated plastic discharge hose for collision compartment submersible electric bilge pump. Use a BIA or ABYC accepted synthetic rubber water hose and insure hose has a loop at least one foot above the thru hull discharge to prevent sea surge from back filling the compartment via the bilge piping. Make sure check valve is free & Clean.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 March 2010
Resolved
Provide a wet location UL junction box for the wiring splice at the electric submersible bilge pump in the fuel tank compt. Make sure splice is well sealed and as high as practicable above the bilge.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 9 March 2010
Resolved
Component:: Wood Sampson posts on foredeck. They are wet and soft at the penetration of the deck and for about 1/4-1/2" of the thickness of the posts below the deck. Pull and examine condition and renew id soft wood penetrated beyond outer surface 1/2" of total.
Construction/Loadline › Hull › Transverse Frame
Issued 9 March 2010
Resolved
Replace broken & wasted bolt fastenings in transverse foundation for the bottom of the Sampson posts in the collision compartment.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 9 March 2010
Resolved
Provide additional venting for compartment where fuel tanks are stored. Compartment lacks sufficient air exchange resulting in excess moisture accumulation and deterioration of hull internals and fuel tank corrosion.
Documentation › Certificates/Documents › FCC SSL
Issued 24 November 2008
Resolved
Safety Radiotelephoney Certificate not aboard. Cell call to radio tech confirmed completion of test and mailing of FCC cert but Master thinks it may be at his home. Vessel is in winter lay-up at this time.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 November 2008
Resolved
Clean or renew white lamp lenses on masthead light and stern light. The plastic material appears to be damaged by exposure to U/V sun light.
Lifesaving › Lifefloat › Serviceable
Issued 24 November 2008
Resolved
U/V damage to web straps of L/F on top of stacked devises caused by exposure to the sun. Outer of the two straps has failed at several purchases for the pendants. The lack of a sun cover has accelerated the deterioration. Factory repair or replacement is required. Passenger count is reduced to 56 persons until this requirement is satisfied.
Electrical › Electric Generation Source (service) › Generator
Issued 24 November 2008
Resolved
Stbd MDE- alternator belts- worn loose and appear oil soaked. Clean pulleys and replace belts.
Electrical › Electric Generation Source (service) › Generator
Issued 24 November 2008
Resolved
Renew alternator belts for 12vdc battery charging system mounted on forward ship service GMC 2-71 genset.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 November 2008
Resolved
Replace missing electrical box covers for splice boxes in aft compartment and fuel tank compartment.
Engineering › Sea-water System (primary cooling) › Pump
Issued 24 November 2008
Resolved
Repair sea water cooling pump leak on GMC 2-71 service generator diesel. 12.31.08 Pump onback order.
Engineering › Bilge Water Management System › Valve
Issued 24 November 2008
Resolved
Replace missing handle for collision bhd bilge suction pipe valve.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 24 November 2008
Resolved
Clean & lubricate the end fittings on all MDE (main diesel engines) control cables.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 24 November 2008
Resolved
Provide proper draft marks on vessel's hull. When setting up location of marks contact USCG inspector to verify location prior to refloating vessel. Due by next drydocking. (see 46 CFR 185.602)
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 November 2008
Resolved
During last exam a small pocket of rot was noted at the upper end of the collision bhd IWO the access hatch. The O/O renewed the bhd in kind. Examined renewed bhd and found satisfactory during this exam. Pictures placed in permanent file.
Communications › Radio Communications › EPIRB
Issued 24 November 2008
Resolved
Provide EPIRB registration record with the 15 alfa-numeric ID from the EPIRB.
Communications › Radio Communications › EPIRB
Issued 24 November 2008
Resolved
[name withheld] hydrostatic release expiration date on EPIRB storage container.
Lifesaving › Lifefloat › Approval
Issued 21 November 2007
Resolved
Considerably aging 6 person life float had no approval label attached. Removed from vessel. Provide an approved replacement. Owner considered reducing passenger count, advised him to write OCMI with request. Total persons aboard count reduced to 75.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 21 November 2007
Resolved
Stbd main engine considerably rusted due to cooling water leak. Make appropriate repairs to all affected components of engine and schedule progress inspection PRIOR to painting, prior to carrying passengers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 November 2007
Resolved
Make full repairs to permanently installed engineroom lighting. Many lights did not work and Stbd side light fixture/conduit is dismantled, broken and unsecured. Remove all temporary lighting (drop lights) and extension cords.
Electrical › Electric Supply System (service) › Battery Charger
Issued 21 November 2007
Resolved
Remove temporary battery charger which is installed in an attempted permanent fashon. Spring clips are corroding, showing high resistance, and are prohibited. Remove extension cords. If desired, a marine grade charger may be permanently installed IAW 46 CFR Part 183.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 November 2007
Resolved
Provide sufficient evidence of required annual maintenance to installed engine room CO2 system, describing detailed testing of individual components. Prior to carrying passengers.
Engineering › Bilge Water Management System › Not Operational
Issued 11 April 2006
Resolved
Prove proper operation of bilge system.
Construction/Loadline › Penetrations › Valve Flange
Issued 11 April 2006
Resolved
Sea cock valve unoperable, stuck open. Connected new valve to inoperable vavle for short term fix. At next dry dock replace old sea cock valve.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 March 2005
Resolved
Tighten stbd shaft packing.
Stability › Watertight Integrity › General
Issued 8 March 2005
Resolved
Seal fwd deck around captain hydro line penetrations, make it watertight.
Engineering › Steering Gear System
Issued 14 April 2004
Resolved
Tighten packing on both rudder posts. LEGACY COMPONENT DESC: Rudder Bearing
Lifesaving › Buoyant Apparatus
Issued 14 April 2004
Resolved
Resurface top of upper lifefloat.
Documentation › Markings/Placards
Issued 14 April 2004
Resolved
Mark emergency fuel shutoffs.
Documentation › Certificates/Documents
Issued 14 April 2004
Resolved
Provide copy of valid document. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Navigation › Piloting/Steering
Issued 27 March 2003
Resolved
PROVIDE NAVIGATIONAL CHART FOR FOR AREA OF OPERATION. LEGACY COMPONENT DESC: Marine Charts
Navigation › Piloting/Steering
Issued 27 March 2003
Resolved
PROVIDE COPY OF INLAND/INTERNATIONAL NAVIGATION RULES. LEGACY COMPONENT DESC: Inland Navigation Rules
Fire Fighting › Remote Fuel Shutoff
Issued 27 March 2003
Resolved
RE-LABEL EMERGENCY FUEL SHUT OFFS. LEGACY COMPONENT DESC: labels
Documentation › Certificates/Documents
Issued 27 March 2003
Resolved
PROVIDE CURRENT COPY OF FCC SAFETY RADIO TELEPHONY CERTIFICATE. vESSEL IS RESTRICTED TO LESS THAN 1000 FEET FROM SHORE UNTIL PROVIDED. LEGACY COMPONENT DESC: FCC SSL
Fire Fighting › Nozzles
Issued 27 March 2003
Resolved
REPLACE FIRE NOZZLE. LEGACY COMPONENT DESC: Type
Engineering › Bilge Water Management System
Issued 27 March 2003
Resolved
INSTALL DOUBLE CLAMPS ON OVERBOARD DISCHARGE HOSE FOR BILGE SYSTEM. LEGACY COMPONENT DESC: Hose
Construction/Loadline › Hull
Issued 9 April 2002
Resolved
Clean & treat furring in engine room. LEGACY COMPONENT DESC: Stringer
Documentation › Certificates/Documents
Issued 25 January 2002
Resolved
POST PAGE TWO OF COI. LEGACY COMPONENT DESC: Certificate of Inspection
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 25 January 2002
Resolved
REMOUNT BRACKET FOR FIRE EXTINGUISHER IN MAIN CABIN. LEGACY COMPONENT DESC: Mounting Bracket
Engineering › Diesel Engine (propulsion-direct drive)
Issued 25 January 2002
Resolved
REPAIR OIL LEAK ON STARBOARD ENGINE. LEGACY COMPONENT DESC: Valve
Accommodation/Occupational Safety › Occupational Safety
Issued 25 January 2002
Resolved
INSTALL MACHINERY GUARDS ON BOTH MAIN ENGINE AND GENERATORS. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Engineering › Fuel Oil Service System
Issued 25 January 2002
Resolved
LABEL LOCATION FOR EMERGENCY FUEL SHUT OFF VALVES LEGACY COMPONENT DESC: Valve, Control
Electrical › Electric Generation Source (service)
Issued 25 January 2002
Resolved
INSTALL ELECTRICAL J-BOX FOR FWD GENERATOR START SWITCH. LEGACY COMPONENT DESC: Switch
Personnel › Training
Issued 25 January 2002
Resolved
PROVIDE CPR/FIRST AID CARD FOR 50% OF THE CREW. LEGACY COMPONENT DESC: First Aid/CPR
Electrical › Lighting (service)
Issued 25 January 2002
Resolved
INSTALL GUARDS FOR LIGHTING FIXTURES THROUGHOUT THE VESSEL. LEGACY COMPONENT DESC: Lighting Fixture
Lifesaving › Lifejacket/PFD (Type III)
Issued 25 January 2002
Resolved
RENEW (10) ADULT LIFE JACKETS AND LABEL WITH VESSEL NAME
Lifesaving › Lifejacket/PFD (Type III)
Issued 25 January 2002
Resolved
CLEAN ALL LIFE JACKETS AND REAPPLY RETRO REFLECTIVE TAPE.
Lifesaving › Lifejacket/PFD (Type III)
Issued 25 January 2002
Resolved
LABEL LIFE JACKETS STOWAGE COMPARTMENT WITH PROPERTY AMOUNT AND TYPE. LEGACY COMPONENT DESC: Storage
Accommodation/Occupational Safety › Washroom/Toilet
Issued 25 January 2002
Resolved
REPLACE VALVE HANDLE FOR WATER IN SINK FEMALE HEAD. LEGACY COMPONENT DESC: Washbasin
Electrical › Electric Generation Source (service)
Issued 25 January 2002
Resolved
REINSTALL MISSING GAUGE IN POWER PANELBOARD FOR FWD GENERATOR. LEGACY COMPONENT DESC: Panelboard
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 25 January 2002
Resolved
REPLACE WINDOW IN MAIN CABIN
Accommodation/Occupational Safety › Medical/First Aid
Issued 25 January 2002
Resolved
PROVIDE COAST GUARD APPROVED FIRST AID KIT OR EQUIVALENT LEGACY COMPONENT DESC: Medicine Chest
Lifesaving › Buoyant Apparatus
Issued 25 January 2002
Resolved
INSTALL DETACHABLE CLIP FOR WATERLIGHT ON RING BUOY
Engineering › Steering Gear System
Issued 25 January 2002
Resolved
SECURE BOLTS AND NUTS ON STEERING ASSEMBLY LEGACY COMPONENT DESC: Fastener
Electrical › Electric Generation Source (service)
Issued 25 January 2002
Resolved
INSTALL GUARD COVER OVER POWER SUPPLY ON FWD GENERATOR LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Engineering › Bilge Water Management System
Issued 25 January 2002
Resolved
RENEW AND PROVE PROPER OPERATION OF FWD COMPARTMENT BILGE VALVE LEGACY COMPONENT DESC: Valve
Engineering
Issued 27 April 2001
Resolved
MAKE PROPER COOLING WATER LEAK ON STARBOARD MDE.
Lifesaving
Issued 27 April 2001
Resolved
PROPERLY LABEL EMERGENCY EMERGENCY ESCAPE HATCHES IN ENGINEROOM AND GENERATOR SPACE.
Electrical
Issued 27 April 2001
Resolved
PROVIDE COVER FOR ELECTRICAL SWITCH BOX ON PORT FORWARD BULKHEAD IN ENGINEROOM.
Electrical
Issued 27 April 2001
Resolved
PROVIDE BATTERY BOX COVER FOR STBD FWD BATTERY BOX IN ENGINEROOM.
Engineering
Issued 27 April 2001
Resolved
MAKE PROPER REPAIRS TO EXHAUST COOLOING WATER LEAK ON PORT MDE.
Engineering
Issued 27 April 2001
Resolved
MAKE PROPER REPAIRS TO LEAK ON COOLING WATER TEMPERATURE SENSOR.
Accommodation/Occupational Safety
Issued 27 April 2001
Resolved
PROVE PROPER OPERATION OF MALE MSD.
Accommodation/Occupational Safety
Issued 27 April 2001
Resolved
PROVIDE RUNNING WATER TO BOTH MALE AND FEMALE HEADS.
Lifesaving
Issued 27 April 2001
Resolved
LABEL LIFEJACKET STOWAGE COMPARTMENTS WITH PROPER TYPE AND NUMBER.
Electrical
Issued 27 April 2001
Resolved
PROVIDE GUARDS FOR LIGHT FIXTURES IN GENERATOR SPACE.
Fire Fighting
Issued 27 April 2001
Resolved
PROVIDE OPERATING INSTRUCTIONS FOR FIXED CO2 SYSTEM AT THE PULL STATION.
Construction/Loadline
Issued 27 April 2001
Resolved
REMOVE EXCESS OIL AND WATER FROM BILGE UNDER GENERATOR.
Engineering
Issued 27 April 2001
Resolved
PROVIDE GUARDS FOR ROTATING MACHINERY ON STARBOARD MDE AT BOTTOM OF LADDER.
Fire Fighting
Issued 27 April 2001
Resolved
PROVIDE APPROVED BRACKET FOR PORTABLE FIRE EXTINGUISHER IN ENGINEROOM.
Lifesaving
Issued 27 April 2001
Resolved
RELABEL LIFEJACKETS WITH VESSEL NAME WHERE FADED.
Electrical
Issued 25 October 2000
Resolved
REPAIR PORT OUTBOARD LIGHT IN E/R BY PMDE.
Construction/Loadline
Issued 25 October 2000
Resolved
REPAIR #3 RIB (LOWER) PORT SIDE IN BOW COMPT.
Engineering
Issued 25 October 2000
Resolved
FUEL TANK SPACE (STBD.) GENERATOR EXHAUST LINE NEEDS A SUPPORT BRACKET.
Construction/Loadline
Issued 25 October 2000
Resolved
FUEL TANK SPACE (STBD) OVERBOARD DISCHARGE NEEDS TO BE CAPPED.
Engineering
Issued 25 October 2000
Resolved
RECLAMP STARBOARD MDE EXHAUST PIPE HOSE AFT END IN FUEL TANK COMPARTMENT.
Construction/Loadline
Issued 25 October 2000
Resolved
REFASTEN #1 RIB (UPPER) PORT SIDE BOW COMPT.IT IS LOOSE.
Construction/Loadline
Issued 25 October 2000
Resolved
REFASTEN #1 TRANSVERSE ON STBD. SIDE OF BOW COMPT.
Construction/Loadline
Issued 25 October 2000
Resolved
REFASTEN #3 TRANSVERSE ON STBD. SIDE OF BOW COMPT.
Electrical
Issued 25 October 2000
Resolved
REPLACE ELEC. BOX COVER IN E/R ON AFT BULKHEAD.
Engineering
Issued 2 May 2000
Resolved
PROVIDE FLAME BOWL FOR GENERATOR FUEL FILTER.
Fire Fighting
Issued 2 May 2000
Resolved
REPAIR AND PROVE PROPER OPERATION OF PORT MAIN ENGINE DRIVEN FIRE PUMP.
Construction/Loadline
Issued 2 May 2000
Resolved
RENEW SALT WATER SUCTION VALVE IN ENGINE ROOM.
Lifesaving
Issued 2 May 2000
Resolved
PROVIDE CREW TRAINING LOG IN ACCORDANCE WITH 46 CFR 185.520 AND 185.524.
Fire Fighting
Issued 2 May 2000
Resolved
PROVIDE COPY OF FIRE SERVICE REPORT.
Navigation
Issued 2 May 2000
Resolved
PROVIDE CURRENT COPY OF TIDE AND CURRENT TABLES.
Lifesaving
Issued 2 May 2000
Resolved
PLACE NAME OF VESSEL ON RING BUOY.
Fire Fighting
Issued 10 March 1999
Resolved
VESSEL IS TO INSTALL A FIXED FIRE EXTINGUISHING SYSTEM IN THE ENGINE COMPARTMENT IAW 46 CFR SUBPART D AND THE VESSELS APPROVED PLANS.
Construction/Loadline
Issued 20 April 1998
Resolved
INSTALL METALIC SHUT OFF VALVE AT THE THRU HULL FITTING LOCATED AT STERN PENETRATION LEADING FROM FISH BAIT BOX.
Engineering
Issued 20 April 1998
Resolved
REPACK PROPELLER SHAFTS AND RUDDER STOCK PACKING GLANDS TO REDUCE EXCESSIVEWATER FROM ENTERING COMPARTMENTS.
Lifesaving
Issued 20 April 1998
Resolved
PROVIDE 406 MHZ EPIRB TO REPLACE INOPERABLE 121.5 CLASS A EPIRB. VESSEL RESTRICTED TO OPERATE NO MORE THAN THREE MILES FROM COASTLINE UNTIL REPLACED.
Engineering
Issued 20 April 1998
Resolved
REPLACE STBD ENGINE EXHAUST HOSE CLAMPS AT THE ELBOW WITH SERVICABLE CLAMPS.
Fire Fighting
Issued 20 April 1998
Resolved
PROVIDE PROOF OF RECENT SERVICING OF THE PORTABLE FIRE EXTINGUISHERS ONBOARD VESSEL.
Construction/Loadline
Issued 21 November 1997
Resolved
REPLACE BILGE PIPE HANGER LOCATED IN ENGINE COMPARTMENT.
Construction/Loadline
Issued 21 November 1997
Resolved
PROVIDE PLANS SHOWING DIMENSIONS AND MATERIAL USED TO BUILD BOW PULPIT._x001C_
Accommodation/Occupational Safety
Issued 21 November 1997
Resolved
PRIOR TO CARRYING PASSENGERS, RE-INSTALL HAND RAILS AROUND MAIN DECK FORWARD OF AMIDSHIPS, PORT AND STBD SIDES.
Engineering
Issued 21 November 1997
Resolved
REPLACE DETERIORATED HOSE CLAMPS ON BOTH MDE'S OVERBOARD DISCHARGE PIPING._x001C__x001C_
Electrical
Issued 21 November 1997
Resolved
REMOVE DEAD END WIRE LEADING FROM RECTIFIER ON GENERATOR LOCATED IN ENGINE COMPARTMENT._x001C_
Engineering
Issued 3 June 1997
Resolved
REPAIR PORT ENGINE EXHAUST ELBOW THAT IS LEAKING WATER THROUGH WELD PINHOLE
Lifesaving
Issued 3 June 1997
Resolved
replace the day and night emergency flares.
Engineering
Issued 3 June 1997
Resolved
REPLACE DETERIATING HOSE CLAMPS ON ENGINE EXHAUST AND RAW WATER COOLING SYSTEMS
Navigation
Issued 3 June 1997
Resolved
PROVIDE CURRENT TIDE AND CURRENT TABLES.
Construction/Loadline
Issued 3 June 1997
Resolved
install positive closure valve on old generator exhaust through hull fitting located in eng room.
Fire Fighting
Issued 3 June 1997
Resolved
REPLACE PORTABLE F/E BRACKET LOCATED IN FORWARD GENERATOR COMPARTMENT.
Lifesaving
Issued 2 October 1996
Resolved
UNTIL DEFECTIVE LIFE PRESERVERS ARE REPLACED WITH SERVICABLE TYPE I LIFE PRESERVERS OF APPRORIATE SIZE, THE VESSEL'S CERTIFICATE OF INSPECTION WILL REFLECT A REDUCTION IN TOTAL PERSONS FROM 112 (108 PAX/4 CREW) TO 81 (77 PAX/4CREW) 160.055/79/0
Construction/Loadline
Issued 25 April 1996
Resolved
COMPLETE INSTALLATION OF ENGINE ROOM VENTILATION DUCTING
Electrical
Issued 25 April 1996
Resolved
COMPLETE THE INSTALLATION OF SHIP SERVICE GENERAL IN MAIN ENGINE ROOM
Engineering
Issued 25 April 1996
Resolved
INSTALL VENT SCREENS IN ENGINE VENTILATION OPENINGS TO PREVENT TRASH FROM ENTERING COMPARTMENT.
Lifesaving
Issued 25 April 1996
Resolved
FABRICATE RESCUE LADDER PLATFORM FOR THIS VESSEL.
Navigation
Issued 25 April 1996
Resolved
REPAIR HYDRAULIC LINE FITTINGS AT STEERING PUMP (STOP SEEPING OF FLUID)_x001C_
Lifesaving
Issued 28 April 1992
Resolved
D1-VESSEL IS RESTRICTED TO COASTWISE ROUTE, UNITL A EPIRB MANLUFACTURE AFTER OCT 1, 1988.
Lifesaving
Issued 5 June 1991
Resolved
VESSEL IS RESTRICTED TO COASTWISE ROUTE UNTIL 11 ADULT LIFEJACKETS WITH LIGHTS ARE PROVIDED._x001C_ _x001C_ _x001C_
Navigation
Issued 5 June 1991
Resolved
REPLACE NAVIGATION CHARTS 12304 AND 12214 WITH UPDATED EDITIONS
Construction/Loadline
Issued 2 May 1991
Resolved
PRIOR TO RETURNING TO WATER REFASTEN STBD RUDDER.
Engineering
Issued 26 April 1989
Resolved
INSTALL HEAT DEFLECTOR SHIELD ON RACOR FUEL FILTER. ORIGINAL COMPLIANCE DATE IS 26MAY89.
Electrical
Issued 9 June 1988
Resolved
PROVIDE PLANS FOR ALL NEW ELECTRICAL INSTALLATIONS AND ALL NEW HULL MODIFICATIONS TO MSO PHILADELPHIA FOR APPROVAL.
Lifesaving
Issued 9 June 1988
Resolved
PROVIDE NEW DATED BATTERIES FOR ALL PFD LIGHTS ON 114 ADULT AND 12 CHILD PFD'S.
Lifesaving
Issued 9 June 1988
Resolved
PROVIDE WEAK LINK FOR LIFE FLOAT PAINTER.
Lifesaving
Issued 9 June 1988
Resolved
RENEW BATTERY FOR EPIRB.
Electrical
Issued 9 June 1988
Resolved
RENEW BATTERY BOXES FOR MAIN ENGINE STARTING BATTERIES.
Construction/Loadline
Issued 11 May 1987
Resolved
RENEW #3 FRAME ON STERN IN BOARD OF THE STARBOARD STERN FRAME.
Electrical
Issued 13 November 1985
Resolved
REMOVE ALL DEAD END WIRING.
Engineering
Issued 13 November 1985
Resolved
REPLACE BEARINGS, ON FWD AND AFT STRUTS, PORT SHAFT.
Electrical
Issued 13 November 1985
Resolved
PROPERLY SPLICE WIRING UNDER CONTROL PANEL IN PILOT HOUSE AND TO BILGE PUMPIN FORWARD COMPARTMENT.
Electrical
Issued 13 November 1985
Resolved
REATTACH GROUNDING WIRES ON BOTH BILGE DISCHARGES IN ENGINE ROOM.
Construction/Loadline
Issued 13 November 1985
Resolved
REATTACH SECOND BRACE AFT, PORT SIDE, IN FORWARD COMPARTMENT. .
Construction/Loadline
Issued 13 November 1985
Resolved
RENEW FIRST SECTION OF DECK TRIM, MAIN DECK, FROM BOW, PORT SIDE.
Casualty record · 1
7 August 2025Routine · role: Involved in a Marine Casualty · activity 8208979
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.