MAURY USCG vessel records Sign in
← All vessels

POLARSTREAM

POLARSTREAM is a 1999 freight ship. The Coast Guard has recorded 25 inspections since 1999, most recently in November 2017, along with 9 deficiencies and 3 operational controls.

Records from 1999 to 2017. Most recent: inspection, 22 November 2017.

Built
1999
Last inspected
22 November 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9189885 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
490887
Flag
LIBERIA
—
Maury page id
psix-490887

Inspections, by type

…with no type recorded6
Years with a record 14 calendar years (1999–2017)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11417 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

22 November 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6311322
13 March 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6103562
10 January 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6068863
4 March 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5826906
26 October 2015 ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5751027
8 August 2014 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4948198
3 January 2012 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4216216
3 January 2012 PII Safety Exam · COE-Offshore · ISPS I Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4217248
30 December 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4215920
28 December 2010 PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3917215
28 December 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3917750
23 March 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3701817
13 January 2010 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3663056
27 July 2009 Random ISPS/MTSA-No PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3547807
28 January 2009 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3401410
7 January 2009 ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3390072
27 February 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3154598
28 January 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3137393
29 January 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2863221
10 March 2006 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2599801
10 January 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2563896
23 February 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1748341
3 September 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1667820
16 August 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1662230
12 November 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 435345

Deficiency record · 9

Electrical › Electric Generation Source (service) › Switch
Issued 3 January 2012 Resolved
0950-Emergency generator sets shall be capable of readily being started. Emergency generator automatic-manual switch, not responding properly. 74SOLAS(1997cons) II-1/44.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2012
Resolved 18 December 2012
Resolution: Received class report attesting to repair of emergency generator automatic-manual switch.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 3 January 2012 Resolved
0950-The machinery shall be adequate for the service for which they are intended. Tachometer not functioning on port outboard generator. 74SOLAS(1997cons) 50(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2012
Resolved 18 December 2012
Resolution: Received class report attesting to the operation of tachometer on port outboard generator.
Navigation › Collision/Grounding Avoidance › Radar
Issued 30 December 2011 Resolved
Vessel Request LOD inoperable RADAR and ARPA
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2012
Resolution: Received class report attesting to repair of radar and ARPA.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 January 2010 Resolved
1730- Oily-water separator equipment - The OWS shall ensure that any oily water mixture discharged into the sea does not exceed 15ppm. Vsl was not able to run the OWS for any length of time without exceeding 15ppm or when trying to just test the OCM the system would trip at .01ppm. Vsl is to retain all oily waste on board and only discharge to a reception facility. MARPOL 06 Annex I Reg 14.6
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 February 2010
Resolved 18 January 2010
Resolution: Received a statement from Class informing that the OWS is now temporarily out of service. All oil is to be retained on board and to be discharged to a reception facility only. A condition issued until 31 Jan 2010.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 January 2009 Resolved
1230 - Railing Cat Walks - While conducting deck walk, PSCO's found broken rail on starboard side adjacent to cargo crane #3 between cargo holds #4 and #3. Vessel is required to make proper repairs and have class attest to repairs.
Action required: 705 - Other - as specified
Due 4 February 2009
Resolved 7 January 2009
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 January 2009 Resolved
1735 - Pumping Discharge Arrangements - Vessel has not had its bunker lines tested since 16 Dec. 2007, missing its required annual bunker line test. Vessel must have bunker lines tested prior to next U.S. port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 January 2009
Resolution: Engineering journal entry of bunker line testing was given to PSCO''''s. Testing had been done in November of 2008.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 10 January 2006 Resolved
Both Port and Starboard lifeboats do not have required amount of rations. Only 12 per side & 25 is required. Vessel is in violation of LSA Code Chapter IV 4.1.5.1.18
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2006
Resolution: Recieved fax report for the purchase of 26 required lifeboat food rations.
Construction/Loadline › Markings
Issued 16 August 2002 Resolved
THE CLASS SOCIETY ID NEEDS TO BE PERMANTLY AFFIXED TO BOTH LOADLINES WHEN THE VESSEL GOES TO DRYDOCK IN JAN OF 2003. LEGACY COMPONENT DESC: Load Line Assigning Authority Mark
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 20 February 2003
Resolution: Plimsoll marks. Manufacture and welding IR letters.. Surveyed by class, satisfactorily
Construction/Loadline › Markings
Issued 16 August 2002 Resolved
BOTH LOADLINES NEED TO BE PAINTED IN A CONTRASTING COLOR TO THE HULL. LEGACY COMPONENT DESC: Load Line Mark
Action required: 15 - Rectify deficiencies by next port
Resolved 3 September 2002

Ownership record