MAURY USCG vessel records Sign in
← All vessels

STINGRAY

STINGRAY is a 1988 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1988, most recently in October 2025, along with 88 deficiencies and 1 casualty investigation in 2011.

Records from 1988 to 2025. Most recent: inspection, 1 October 2025.

Built
1988
Last inspected
1 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN4811
490917
Flag
UNITED STATES
368284410
Maury page id
psix-490917

Inspections, by type

…with no type recorded1
Years with a record 30 calendar years (1988–2025)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 5 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS · TARPON SPRINGS, FL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portHOMESTEAD, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 28 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN4811MMSI 368284410 · active · compulsorily equipped · granted 5 November 2022, expires 5 November 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

1 October 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8243468
17 October 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8020948
25 September 2024 Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8008892
17 October 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7810136
18 December 2022 In-Service Inspection · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7610649
21 October 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7591106
20 October 2022 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7587813
31 August 2021 Internal Structural Exam · Construction Oversight · Administrative Inspection · Plan Review "T" Boat · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7335704
27 August 2021 Plan Review "T" Boat
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7343110
12 April 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7178370
13 March 2018 Damage Survey · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6371278
31 July 2017 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6340033
12 April 2017 Internal Structural Exam · DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6214427
14 January 2016 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5796982
23 July 2015 Drydock Exam · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5192151
12 June 2014 COI Inspection · Simplified Stability Test · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4914182
11 January 2011 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3919743
16 February 2010 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3680656
9 December 2009 Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3647208
21 January 2009 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3393128
17 January 2008 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3126580
4 December 2007 Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3109046
17 April 2007 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2908606
25 January 2007 Deficiency Check · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2861874
30 January 2006 COI Inspection · Hull Examination · Simplified Stability Test
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2571751
14 November 2001 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1076462
6 July 2000 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1401273
23 August 1999 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1421724
10 August 1999 Drydock Extension
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 776328
20 July 1999 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1432159
31 August 1998 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 796934
14 August 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 774779
8 July 1997 COI Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1422935
2 May 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1104607
14 April 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1093891
15 November 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1469474
25 July 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1087568
24 July 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1085209
16 July 1996 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1465875
14 August 1995 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1182804
2 August 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 875967
12 July 1995 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 883056
7 April 1995 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 836631
14 October 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 867472
12 July 1994 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 866628
9 June 1993 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 836800
5 May 1993 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1132566
21 April 1993 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 840567
20 May 1992 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1151609
13 May 1991 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1237133
12 March 1991 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 921079
4 September 1990 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1243092
21 August 1990 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1235576
6 July 1989 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1034032
15 May 1989 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1207659
20 May 1988 Initial Certification · Plan Review "T" Boat
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 896031
27 April 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1038379

Deficiency record · 88

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2025 Resolved
The lights prescribed in these rules shall have an intensity as specified...so as to be visible at the followign minimum ranges: a sidelight, 3 miles. The port sidelight was extinguished.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 20 November 2025
Resolution: Replaced bulb.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 October 2025 Resolved
A vessel on LBS.LC route must carry: 6 hand red flare distress signals and 6 hand orange smoke distress flares. Red hand flares may be substituted for the orange smoke distress flares. Vessel missing 7 distress signals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 20 November 2025
Resolution: Added distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2025 Resolved
Each lifering buoy must be marked in clearly legible block letters with the vessels name. Name was faded on the life ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 20 November 2025
Resolution: Renewed lettering.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 October 2025 Resolved
The owner must conduct all tests required by the [name withheld] to self reported engine failure, under way drills were not conducted. Man overboard and fire drill to be completed once engine is repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2025
Resolved 20 November 2025
Resolution: Completed drills.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 12 April 2017 Resolved
Port and STBD nav lights are installed incorrectly and do not provide proper angle of visibility. Remount to provide 112.5 degrees of visibility.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 27 April 2017
Resolution: Nav lights were remounted in the proper location.
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 April 2017 Resolved
Battery box is broken and will not protect the vessel if the battery leaks.Replace box.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 27 April 2017
Resolution: New battery box was installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 April 2017 Resolved
First aid kit is missing contents. Provide.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 27 April 2017
Resolution: New approved kit was provided.
Lifesaving › Lifebuoys › Approval
Issued 12 April 2017 Resolved
Life ring is missing retro tape. repair/renew.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 27 April 2017
Resolution: New retro tape was installed.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 12 April 2017 Resolved
Flares are not in the correct watertight container. Provide new container.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 27 April 2017
Resolution: New container was provided.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 12 April 2017 Resolved
Vessel is missing a waste management plan. Provide and post.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 27 April 2017
Resolution: Plan was created and posted.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 12 April 2017 Resolved
Vessel is missing emergency instructions list. Provide and post.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 27 April 2017
Resolution: Emergency instructions were printed and posted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 April 2017 Resolved
Vessel does not have COI or Stability letter posted. Post.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 27 April 2017
Resolution: COI and Stability letter were both properly posted.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 January 2011 Resolved
Provide evidence of a complete chemical testing program IAW 46CFR16. Shall be completed prior to 25JAN11.
Action required: 705 - Other - as specified
Due 25 January 2011
Resolved 26 January 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 January 2011 Resolved
Conduct and properly log drills every 03 months IAW 46CFR185.520. Shall be completed prior to 25JAN11.
Action required: 705 - Other - as specified
Due 25 January 2011
Resolved 26 January 2011
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 January 2011 Resolved
Provide current navigation publications to include U.S. Coast Pilot - CG Light List - Tide Tables - NAV Rules IAW 46CFR184.420. Shall be completed prior to 25JAN11.
Action required: 705 - Other - as specified
Due 25 January 2011
Resolved 26 January 2011
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 January 2011 Resolved
Provide/Install light for magnetic compass IAW 46CFR184.402. Limited to daytime trips until completed.
Action required: 705 - Other - as specified
Resolved 10 February 2011
Resolution: Vessel''''s magnetic compass has operational light.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 January 2011 Resolved
Provide crew emergency procedcueres on board vsl for fire and abandon ship IAW 46CFR185.510. Shall be completed prior to 25JAN11.
Action required: 705 - Other - as specified
Due 25 January 2011
Resolved 10 February 2011
Resolution: Vessel has onboard emergency proceedures, posted next to helm.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 January 2011 Resolved
Provide water light battery in compliance with manufacturer's recommendation IAW 46CFR180.70. Limited to daytime trips until corrected.
Action required: 705 - Other - as specified
Resolved 10 February 2011
Resolution: Water light batter installed and is in compliance with the manufacturer''''''''s recommendations.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 11 January 2011 Resolved
Replace fire extinguisher bracket on stern B-II mount IAW 46CFR176.810. Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 January 2011 Resolved
Repair replace rail course netting throughout vsl IAW 46CFR177.900. Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2011
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 22 February 2010 Resolved
Replace wing nuts on batteries with hex head nuts.
Due 22 February 2010
Resolved 23 February 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 February 2010 Resolved
Replace soft spot on decking forward on port side.
Due 22 February 2010
Resolved 23 February 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 February 2010 Resolved
Replace expired items in first aid kit.
Due 22 February 2010
Resolved 23 February 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2010 Resolved
Remove dead end wires and replace damaged wires.
Due 22 February 2010
Resolved 23 February 2010
Communications › Alarms/Indicators › Fire Alarm
Issued 17 January 2008 Resolved
Install smoke detector on vessel.
Due 20 January 2008
Resolved 24 January 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 25 January 2007 Resolved
Install cap fuel fill line
Due 30 January 2007
Resolved 30 January 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 25 January 2007 Resolved
Relocate one BII extinguisher forward.
Due 30 January 2007
Resolved 30 January 2007
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 30 January 2006 Resolved
PROVIDE EMERGENCY INSTRUCTION LIST THAT MATCHES VESSEL EQUIPMENT AND CAPABILITIES.
Due 13 February 2006
Resolved 1 February 2006
Documentation › Certificates/Documents › Stability Letter
Issued 30 January 2006 Resolved
PRIOR TO OPERATION PLACE A COPY OF THE NEW STABILITY LETTER ONBOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2006
Resolved 1 February 2006
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 30 January 2006 Resolved
LABEL FUEL EMERGENCY CUT-OFF VALVES.
Due 20 February 2006
Resolved 1 February 2006
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 30 January 2006 Resolved
PROVIDE A PROPER BELL ONBOARD OF AT LEAST 7.9 INCHES IN DIAMETER.
Due 20 February 2006
Resolved 1 February 2006
Electrical › Electric Generation Source (service) › Conductor
Issued 14 December 2005 Resolved
PROVIDE A LINE DIAGRAM OF ALL ELECTRICAL WIRES INCLUDING LENGTH OF WIRE, GUAGE, USE, AND MAX AMP DRAW OF THE DEVICE.
Due 26 January 2006
Resolved 14 December 2005
Electrical › Electric Generation Source (service) › Conductor
Issued 14 December 2005 Resolved
REMOVE ALL 16 AWG WIRE FROM LIGHTING CIRCUITS AND RENEW WITH 14 AWG OR LARGER GUAGE WIRE.
Due 26 January 2006
Resolved 25 January 2006
Construction/Loadline › Structures › Deck Plating
Issued 14 December 2005 Resolved
PROVIDE A LIST OF MATERIALS USED TO REBUILD DECK INCLUDING TYPE AND SIZE OF PLYWOOD, TYPE OF frp MAT AND RESIN, AND SIZE AND TYPE OF TRANSVERSE FRAMES INSTALLED.
Due 26 January 2006
Resolved 14 December 2005
Fire Fighting
Issued 6 July 2000 Resolved
TWO BII EXTINGUISHERS NEEDED.
Condition: Unknown
Due 21 July 2000
Resolved 19 July 2000
Lifesaving
Issued 6 July 2000 Resolved
EMERGENCY BROADCAST PLACARD MISSING.
Condition: Unknown
Due 21 July 2000
Resolved 19 July 2000
Documentation
Issued 6 July 2000 Resolved
STABILITY NOT POSTED.
Condition: Unknown
Due 21 July 2000
Resolved 19 July 2000
Lifesaving
Issued 6 July 2000 Resolved
24 LIFE JACKETS REJECTED DUE TO DEFECTS.
Condition: Unknown
Due 21 July 2000
Resolved 19 July 2000
Navigation
Issued 6 July 2000 Resolved
RUNNINGS LIGHTS INOPERABLE.
Condition: Unknown
Due 21 July 2000
Resolved 19 July 2000
Lifesaving
Issued 31 August 1998 Resolved
PROVIDE THREE ADDITIONAL HAND HELD FLARES. (OLIN FLARE PISTOL ABOARD IN INTERIM).
Condition: Unknown
Due 15 September 1998
Resolved 8 September 1998
Lifesaving
Issued 31 August 1998 Resolved
POST VESSEL NAME ON LIFE RING AND PROVIDE SIXTY FEET OF DARK OR UV RESISTANT FLOTATION LINE.
Condition: Unknown
Due 15 September 1998
Resolved 8 September 1998
Documentation
Issued 31 August 1998 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Engineering
Issued 31 August 1998 Resolved
REPLACE PORT OUTBOARD ENGINE STARTER SOLENOID.
Condition: Unknown
Due 15 September 1998
Resolved 8 September 1998
Lifesaving
Issued 31 August 1998 Resolved
POST EMERGENCY CHECKLIST.
Condition: Unknown
Due 15 September 1998
Resolved 8 September 1998
Lifesaving
Issued 31 August 1998 Resolved
PROVIDE NINE ADULT LIFE PRESERVERS. VESSEL RESTRICTED TO CARRIAGE OF 40 ADULT PASSENGERS UNTIL CORRECTED.
Condition: Unknown
Due 15 September 1998
Resolved 8 September 1998
Documentation
Issued 31 August 1998 Resolved
DISPLAY STATE REGISTRATION NUMBER ON BOTH BOWS (UNTIL DOCUMENTATION IS COMPLETE-IN PROCESS).
Condition: Unknown
Due 15 September 1998
Resolved 8 September 1998
Documentation
Issued 31 August 1998 Resolved
KEEP ORIGINAL CERTIFICATE OF INSPECTION ON BOARD.
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Accommodation/Occupational Safety
Issued 8 July 1997 Resolved
Replace three missing fasteners, in way of port Handrail stanchion #5.
Condition: Unknown
Due 8 August 1997
Resolved 24 November 1997
Construction/Loadline
Issued 8 July 1997 Resolved
Make repairs to fiberglass in way of forward-bow areas of stbd/port pontoons, and stbd corner wrapper, where so marked.
Condition: Unknown
Due 8 August 1997
Resolved 24 November 1997
Lifesaving
Issued 8 July 1997 Resolved
Conduct underway drills to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 8 August 1997
Resolved 24 November 1997
Lifesaving
Issued 8 July 1997 Resolved
INSTALL NAME OF VESSEL IN 2" CONTRASTING LETTERS ON RING BUOY.
Condition: Unknown
Due 8 August 1997
Resolved 24 November 1997
Lifesaving
Issued 8 July 1997 Resolved
Provide & post emergency checkoff list on board in a conspicuous location.
Condition: Unknown
Due 8 August 1997
Resolved 24 November 1997
Lifesaving
Issued 8 July 1997 Resolved
PROVE PROPER OPERATION OF RING BUOY LIGHT
Condition: Unknown
Due 8 August 1997
Resolved 24 November 1997
Engineering
Issued 8 July 1997 Resolved
Install 30x30 mesh screen in fuel tank vent gooseneck, in way of fuel tank.
Condition: Unknown
Due 8 August 1997
Resolved 24 November 1997
Accommodation/Occupational Safety
Issued 8 July 1997 Resolved
Repair head access door as original.
Condition: Unknown
Due 8 August 1997
Resolved 24 November 1997
Accommodation/Occupational Safety
Issued 8 July 1997 Resolved
Disconnect and remove from the vessel MSD electric pump and discharge hose in way of port pontoon.
Condition: Unknown
Due 8 August 1997
Resolved 24 November 1997
Engineering
Issued 15 November 1996 Resolved
CONDUCT OPERATIONAL TESTS UNDERWAY AND PROVE PROPER OPERATION OF STARBOARD ENGINE NLT 15 DEC 96.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Accommodation/Occupational Safety
Issued 15 November 1996 Resolved
REPAIR ALL CRACKS IN GUARD RAIL STANCHIONS IN WAY OF DECK NLT 31 JAN 97.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Navigation
Issued 15 November 1996 Resolved
AFFIX STARBOARD NAV LIGHT AND STERN LIGHT NLT 15 DEC 96. VESSEL RESTRICTEDTO DAYLIGHT OPERATIONS UNTIL IN COMPLIANCE.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Construction/Loadline
Issued 15 November 1996 Resolved
REPLACE APPROXIMATELY 8 X 8 FOOT SECTION OF MAIN DECK AT STARBOARD AFT CORNER NLT 31JAN97.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Documentation
Issued 16 July 1996 Resolved
PROVIDE RANDOM DRUG TESTING RESULTS FOR ONE MEMBER OF CREW PRIOR TO OPERATING WITH PASSENGERS IAW 46 CFR 16.230.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Lifesaving
Issued 16 July 1996 Resolved
PROVIDE WATER TIGHT CONTAINER OF A BRIGHT COLOR AND MARKED "DISTRESS SIGNALS" IAW 46 CFR 185.614._x001C_
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Documentation
Issued 16 July 1996 Resolved
PROVIDE COPY OF COMPANY DRUG TESTING POLICY NLT 23 JUL 96.
Condition: Unknown
Due 25 July 1996
Resolved 25 July 1996
Construction/Loadline
Issued 16 July 1996 Resolved
REPLACE APPROXIMATELY 8 X 8 FOOT SECTION OF MAIN DECK AT STARBOARD AFT CORNER NLT 31JAN97.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Documentation
Issued 16 July 1996 Resolved
PROVIDE PRE-EMPLOYMENT DRUG TESTING RESULTS FOR NEW MEMBER OF CREW PRIOR TOOPERATING WITH PASSENGERS IAW 46 CFR 16.210.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Unknown
Issued 16 July 1996 Resolved
CONDUCT OPERATIONAL TESTS IN PRESENCE OF COAST GUARD INSPECTOR NLT 16 AUG 96.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Unknown
Issued 16 July 1996 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 16 July 1996 Resolved
PROVIDE LIFE JACKET INSTRUCTION PLACARD IAW 46 CFR 185.516 NLT 16 AUG 96.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Engineering
Issued 16 July 1996 Resolved
PROVIDE 30X30 MESH FLAME SCREEN FOR FUEL TANK VENT PIPE PRIOR TO OPERATION IAW 46 CFR 182.450(e).
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Electrical
Issued 16 July 1996 Resolved
PERMANENTLY AFFIX NAV LIGHT WIRE CONNECTION LOCATED IN STARBOARD AFT SPONSON NLT 16AUG96 IAW 46 CFR 183.340(g).
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Fire Fighting
Issued 16 July 1996 Resolved
PROVIDE ONE B-II FIRE EXTINGUISHER PRIOR TO OPERATION WITH PASSENGERS.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Engineering
Issued 2 August 1995 Resolved
REMOVE GASOLINE TANK AND REPLACE WITH COAST GUARD APPROVED GASOLINE TANKS, AS PER ORIGINAL, IN ACCORDANCE WITH 46 CFR 176.20-1(a).
Condition: Unknown
Due 15 August 1995
Resolved 14 August 1995
Construction/Loadline
Issued 12 July 1995 Resolved
INSTALL BILGE SYSTEM IN ACCORDANCE WITH 46 CFR 182.25-1.
Condition: Unknown
Due 12 July 1995
Resolved 12 July 1995
Lifesaving
Issued 12 July 1995 Resolved
MARK LIFE PRESERVER STORAGE IN ACCORDANCE WITH 46 CFR 180.25-15.
Condition: Unknown
Due 12 July 1995
Resolved 12 July 1995
Fire Fighting
Issued 12 July 1994 Resolved
HAVE ALL THREE PORTABLE FIRE EXTINGUISHERS SERVICED BY A LICENSED SERVICINGFACILITY.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Documentation
Issued 9 June 1993 Resolved
PROVIDE EVIDENCE OF RANDOM DRUG TESTING PROGRAM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Navigation
Issued 9 June 1993 Resolved
PROVIDE INSPECTION REGS PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Fire Fighting
Issued 9 June 1993 Resolved
PROVIDE SUITABLE LENGTH HOSE FOR FIRE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Electrical
Issued 9 June 1993 Resolved
SECURE BATTERIES PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Engineering
Issued 9 June 1993 Resolved
PROVIDE USCG APPROVED FUEL LINES PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Navigation
Issued 9 June 1993 Resolved
PROVIDE 8 INCH BELL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Navigation
Issued 9 June 1993 Resolved
PROVIDE NAVIGATION RULES PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Electrical
Issued 13 May 1991 Resolved
PROVIDE PROPERY BATTERY BOXES AND COVERS FOR TWO 12-VOLT BATTERIES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Fire Fighting
Issued 13 May 1991 Resolved
PROVIDE U.S. COAST GUARD APPROVED BRACKETS FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Navigation
Issued 21 August 1990 Resolved
MAKE PERMANENT REPAIRS TO STERN LIGHT SCREEN.
Condition: Unknown
Due 21 August 1990
Resolved 21 August 1990
Engineering
Issued 21 August 1990 Resolved
PROVIDE APPROVED FUEL LINE FOR STBD ENGINE PRIOR TO CARRYING PASSENGERS FORHIRE.
Condition: Unknown
Due 21 August 1990
Resolved 21 August 1990
Fire Fighting
Issued 21 August 1990 Resolved
REPLACE B-I FIRE EXTINGUISHER AND PROVIDE PROPERLY INSTALLED BRACKET FOR SAME.
Condition: Unknown
Due 21 August 1990
Resolved 21 August 1990
Fire Fighting
Issued 21 August 1990 Resolved
PROVIDE AND INSTALL APPROVED BRACKET FOR B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 21 August 1990
Resolved 21 August 1990

Casualty record · 1

24 March 2011Routine · role: Involved in a Marine Casualty · activity 3970981
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.