Records from 2013 to 2026. Most recent: inspection, 24 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 22
24 April 2026
COI Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8355071
27 May 2025
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8145827
29 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7926940
24 April 2024
Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7903667
24 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7696060
15 June 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7478660
3 May 2022
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7443292
30 May 2021
Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 7254383
7 May 2021
DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7191731
5 May 2020
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6952310
18 March 2020
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6928729
3 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6827533
18 July 2019
Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6758555
13 May 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6675591
7 October 2018
Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6887301
26 May 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6436428
23 May 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6420952
25 April 2018
Plan Review "T" Boat
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6399303
23 April 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6397518
2 September 2017
Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 6262166
5 May 2017
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6166813
28 April 2016
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5875278
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 May 2025
Resolved
Engine room high water alarm is inoperable. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 3 June 2025
Resolution: operational, test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2025
Resolved
Prove proper operation of installed bilge system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 3 June 2025
Resolution: bilge pump repaired, tested sat
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 27 May 2025
Resolved
Provide proof of enrollment in CG approve drug testing program to include negative test results.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 9 June 2025
Resolution: received photos of neg test results
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 June 2022
Resolved
Conduct satisfactory test of fire detection system (heat sensor)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 24 August 2022
Resolution: Test swich was installed per manufacturer.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 May 2021
Resolved
The forwardspace and lazarette bilge pumps need to indicate visually in both automatic and manual mode at the helm station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 14 May 2021
Resolution: installed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 May 2021
Resolved
Replace all expired medicines that are required to be held onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 14 May 2021
Resolution: replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 7 May 2021
Resolved
Renew the FCC radio safety certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 14 May 2021
Resolution: renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 June 2020
Resolved
Due to COVID vessel plans to remain in drydock at local shipyard. Vessel to complete sea trials and drills with crew prior to carrying passengers if a plan to operate during CY 2020 is decided.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2020
Resolved 7 May 2021
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 June 2020
Resolved
Liferaft servicing needs to be valid for operation by an approved technician.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2020
Resolved 7 May 2021
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 June 2020
Resolved
Fire extinguishers and pre-engineered fire system needs to have valid servicing by an approved technician.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2020
Resolved 7 May 2021
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2019
Resolved
Engine driven bilge pump is not operating properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2019
Resolved
The electric submersible bilge pump under accommodations space must be permanently mounted to vessel
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 15 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2019
Resolved
Cap open ended wires (3) near forward starboard e/r bulkhead
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 15 May 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2019
Resolved
Replace rusted fuel shutoff valve at the starboard fuel tank
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 15 May 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2019
Resolved
Remote handles for fuel shutoff must be shielded from flames from the space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 15 May 2019
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 23 May 2018
Resolved
Mount bigle pump located in hold #2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 4 June 2018
Communications › Alarms/Indicators › High Water Alarm
Issued 23 May 2018
Resolved
High water alarm in #2 hold inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 4 June 2018
Electrical › Electric Supply System (service) › Cable
Issued 23 May 2018
Resolved
Dead end wires found in forward bunkroom, wire runs require wire clips.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 4 June 2018
Engineering › Steering Gear System › Rudder Bearing
Issued 23 May 2018
Resolved
Rudder packing leaking excessively.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 4 June 2018
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 May 2018
Resolved
Replace 09 Lifejackets
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 4 June 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2018
Resolved
Lifebuoy light battery requires replacement
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 4 June 2018
Construction/Loadline › Structures › End Bulkhead
Issued 23 April 2018
Resolved
Fiberglass delamination along the aft bulkhead in the bunkroom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 12 June 2018
Resolution: Vessel repaired fiberglass IAW NVIC and verified by MI.
Engineering › Bilge Water Management System › Pump
Issued 5 May 2017
Resolved
Permanently mount bilge pump in #2 hold.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 12 June 2018
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 5 May 2017
Resolved
Make repairs to collision bulkhead.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 12 June 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 May 2017
Resolved
Install instructions for fixed fire fighting extinguisher.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 12 June 2018
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 5 May 2017
Resolved
Clean oil water out of bilge in engine room.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 12 June 2018
Electrical › Electric Generation Source (service) › Generator
Issued 5 May 2017
Resolved
Make repairs to alternator belt on engine.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 12 June 2018
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 5 May 2017
Resolved
Replace cover on generator.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 12 June 2018
Engineering › Steering Gear System › Bracket/Clamp
Issued 5 May 2017
Resolved
Make repairs to rudder mount.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 12 June 2018