← All vessels
C-PROVIDER
Offshore Supply Vessel · Offshore class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named C-PROVIDER
C-PROVIDER is a 1999 offshore supply vessel. The Coast Guard has recorded 29 inspections since 1999, most recently in July 2020, along with 24 deficiencies and 1 casualty investigation in 2015.
Records from 1999 to 2020. Most recent: inspection, 30 July 2020.
- Built
- 1999
- Last inspected
- 30 July 2020
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2015
Identity
1077918
9213014 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCZ2441
491015
Flag
UNITED STATES
338461000
Maury page id
psix-491015
Inspections, by type
…with no type recorded2
Years with a record
17 calendar years (1999–2020)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)221.5 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,092 / net 627
ITC dimensions (L × B × D)221.5 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,092 / net 627
BuilderNORTH AMERICAN FAB.LLC · HOUMA, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2092 - Convention (Subpart B), Gross Ton
627 - Convention (Subpart B), Net Ton
3228 - Dead Weight, Ton
627 - Convention (Subpart B), Net Ton
3228 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCZ2441MMSI 338461000 · active · compulsorily equipped · granted 16 March 2019, expires 6 May 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 29
30 July 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7019949
26 July 2017
Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6221816
27 June 2017
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6189784
19 October 2016
Administrative Inspection · Annual Inspection · ACP Periodic Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6026973
22 September 2015
Administrative Inspection · ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5726206
13 February 2012
ACP Annual Oversight · Annual Inspection · MARPOL Annex IV Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4228525
26 January 2011
DAPI Audit · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3880560
8 April 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3448591
3 December 2008
MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3364569
31 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245335
21 September 2007
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3070625
29 May 2007
ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2967109
11 October 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2798631
16 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750173
2 July 2006
Internal Structural Exam · Cargo Tank Internal · Hull Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2724415
18 November 2005
ACP Annual Oversight
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2537164
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501701
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2294006
17 June 2004
MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2064793
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979598
22 August 2003
ACP COI Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1937056
14 August 2003
Hull Examination · Cargo Tank Internal · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1875411
25 June 2002
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1636467
19 October 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439279
24 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 47710
27 June 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373524
25 October 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1057261
10 July 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433697
30 June 1999
Initial Construction-Excluding Oversight · Initial Certification · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430713
Deficiency record · 24
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 26 July 2017
Resolved
Three life raft hydrostatic release units were installed incorrectly. Install hydrostatic release units so life rafts will float free.
Lifesaving › Launching Appliances › Davit
Issued 13 February 2012
Resolved
Rescue boat crane inoperable due to faulty hydraulic valves. Prove proper operation of the rescue boat crane to launch and retrieve.
Stability › Watertight Integrity › General
Issued 13 February 2012
Resolved
Make welding repairs to Z-drive room escape hatch and adjust to make watertight.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 February 2012
Resolved
Make operable emergency light in Emergency Generator Room.
Stability › Watertight Integrity › General
Issued 13 February 2012
Resolved
Adjust all watertight doors throughout Engine Room.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 February 2012
Resolved
Adjust both vestibule doors to Laundry Room and Passageway.
Communications › Radio Communications › EPIRB
Issued 13 February 2012
Resolved
Replace EPIRB mount.
Construction/Loadline › Markings › Load Line Mark
Issued 13 February 2012
Resolved
Paint stbd deck line.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 13 February 2012
Resolved
Provide and install flame screens for all fuel, oil, liquid mud, and sewage tanks.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 February 2012
Resolved
Provide whistles for 3 lifejackets.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 February 2012
Resolved
Replace stbd bridge wing floatlight battery.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 13 February 2012
Resolved
Provide CG approved portable fire extinguishers (one) in Engine Room and (one) in Tank Room.
Lifesaving › Rocket Parachute Flares › General
Issued 13 February 2012
Resolved
Provide CG approved red rocket flares.
Engineering › Fuel Oil Service System › Hose
Issued 13 February 2012
Resolved
Replace (3) fuel hoses on stbd generator and (2) fuel hoses on port generator to those meeting the SAE J-1942 standard.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 26 January 2011
Resolved
Provide drug and alcohol testing policy in accordance with 46 CFR, Part 16. Vessel does not currently conduct random testing on Brazilian mariners.
Construction/Loadline › Structures › Door
Issued 26 January 2011
Resolved
Replace gaskets and adjust dogs on water tight doors at upper entrance to engine room and aft engine room door.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 18 November 2005
Resolved
Prior to operation beyond the Baia De Todos Brazil the following documents shall be properly endorsed by the ABS. A) Safety Construction Certificate. B) Safety Equipment Certificate. C) IOPP
Engineering › Diesel Engine (propulsion-direct drive)
Issued 25 June 2002
Resolved
NO CHAFFING GEAR INSTALLED ON Z-DRIVE UNITS. LEGACY COMPONENT DESC: Z-DRIVE HOSES
Communications › Visual Communication › Signalling Lamp
Issued 25 June 2002
Resolved
NO VISUAL INDICATOR IN Z-DRIVE ROOM FOR SOUND POWERED PHONE.
Electrical › Electric Supply System (service)
Issued 25 June 2002
Resolved
IMPROPER BATTERY INSTALLATION ON 02 LEVEL LOCATED INSIDE AIR CONDITIONING SPACE. LEGACY COMPONENT DESC: Battery Installation
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 25 June 2002
Resolved
FUEL OIL TRANSFER PROCEDURES MISSING.
Documentation › Markings/Placards
Issued 25 June 2002
Resolved
SEVERAL IMO SYMBOLS MISSINGTHROUGHOUT VESSEL. LEGACY COMPONENT DESC: IMO SYMBOLS
Navigation
Issued 10 July 2000
Resolved
Demonstrate proper operation of echo depth sounder recording device to the satisfaction of the attending marine inspector.
Documentation
Issued 10 July 2000
Resolved
PROVIDE USCG APPROVAL AND APPROVED DRAWINGS FOR FUEL SYSTEM PIPING MODIFICATION. MAKE MODIFIED PIPING AVAILABLE FOR INSPECTION BY MARINE INSPECTOR PRIOR TO USING MODIFIED PIPING.
Casualty record · 1
31 October 2015Routine · role: Involved in a Marine Casualty · activity 5774499
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National