Records from 1999 to 2007. Most recent: inspection, 14 December 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
14 December 2007
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3115863
27 July 2005
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2441670
11 June 2003
Passenger/Freight Vessel Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1901708
21 May 2003
Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1804030
24 June 2002
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1646917
16 April 2002
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1601267
3 April 2002
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1603164
6 November 2001
Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1436653
23 May 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393706
16 June 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821247
28 July 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1105401
20 July 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1101194
8 April 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 773096
8 April 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1469289
5 March 1999
Initial Certification · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1390959
Construction/Loadline › Hull › Side Shell
Issued 27 July 2005
Resolved
Make proper repairs to numerous injurious scars to gel coat exposing FRP laminate in way of stem and forward Vee body below the water line (as a result of contact with trailer).
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 15 August 2005
Construction/Loadline › Structures › Deck Plating
Issued 27 July 2005
Resolved
Make proper repairs to bow deck core material decayed and delaminated (soft). Make temporary repairs to shore area up prior to carrying passengers.
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 15 August 2005
Resolution: Bow deck sufficiently repaired temporarily to allow safe operations. Plans to permanently repair by in kind replacement of entire bow deck area.
Construction/Loadline › Hull › Stiffener
Issued 27 July 2005
Resolved
Make proper repairs to forward end of outboard bilge stringer (stiffener) tab fractured.
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 15 August 2005
Construction/Loadline › Structures › Door
Issued 27 July 2005
Resolved
Repair broken access hatch in way of forward bow area.
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 15 August 2005
Communications › Radio Communications
Issued 3 April 2002
Resolved
Obtain FCC Marine Radio Operator permit for Capt
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2002
Resolved 3 April 2002
Resolution: Captain obtained FCC Marine radio operator permit.
Fire Fighting
Issued 6 November 2001
Resolved
RENEW PORTABLE FIRE EXTINGUISHER BRACKETS IAW 46 CFR 181.500 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner renewed portable brackets.
Electrical
Issued 6 November 2001
Resolved
PROVIDE PORTABLE EMERGENCY LIGHTS IAW 46 CFR 183.430.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner provided portable emergency lights.
Engineering
Issued 6 November 2001
Resolved
REPAIR FUEL TANK MOUNTS STBD SIDE E/R PRIOR TO CARRYING PASSENGERS OR PRIORTO 06JAN01.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner repaired fuel tank mounts.
Documentation
Issued 6 November 2001
Resolved
PROVIDE FCC SAFETY CERTIFICATE AND LICENSE IAW 47 CFR PART 80, PRIOR TO OPERATING BEYOND 1000 FEET FROM SHORE OR PRIOR TO 06DEC01.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner provided Certificates.
Construction/Loadline
Issued 6 November 2001
Resolved
REPAIR BILGE HIGH LEVEL ALARM IAW 46 CFR 182.530 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner repaired bilge high level alarms.
Construction/Loadline
Issued 6 November 2001
Resolved
RENEW BILGE FLEXIBLE HOSE WITH APPROVED TYPE IAW 46 CFR 182.720 PRIOR TO 06JAN01.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner renewed flexible hose with approved hose.
Electrical
Issued 6 November 2001
Resolved
REPAIR BILGE WIRE WITH COMPRESSION CONNECTOR AND REMOVE DEAD END CABLES IAW46 CFR 183.340.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner repaired bilge wire.
Engineering
Issued 6 November 2001
Resolved
REPAIR E/R BLOWER TRUNK IAW 46 CFR 182.465 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner repaired E/R blower trunk.
Lifesaving
Issued 6 November 2001
Resolved
PROVIDE EMERGENCY INSTRUCTION LIST IAW 46 CFR 185.510 PRIOR TO 06JAN01.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner provided Emergency instruction list.
Lifesaving
Issued 6 November 2001
Resolved
PROVIDE FIRST AID KIT IAW 46 CFR 184.710 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner provided first aid kit.
Documentation
Issued 6 November 2001
Resolved
PROVIDE ORIGINAL CERTIFICATE OF DOCUMENTATION IAW 46 CFR PART 67.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner provided COD.
Engineering
Issued 6 November 2001
Resolved
REPAIR FUEL TANK VENT PORT SIDE IAW 46 CFR182.450 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner repaired fuel tank vent.
Lifesaving
Issued 6 November 2001
Resolved
PROVIDE LIFE JACKET DONNING PLACARD IAW 46 CFR 185.516 PROIR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner provided Lifejacket donning placard.
Lifesaving
Issued 6 November 2001
Resolved
RENEW RING BUOY IAW 46 CFR 180.70 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner purchased new ring buoy.
Navigation
Issued 6 November 2001
Resolved
REPAIR NAVIGATION LIGHTS (STBD RUNNING LIGHT) IAW 33 CFR PART 84 PRIOR TO NIGHT OPERATION.
Condition: Unknown
Due 6 January 2002
Resolved 3 April 2002
Resolution: Owner repaired navigation lights.
Lifesaving
Issued 5 March 1999
Resolved
Provide working water light for life ring._x001C_
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Documentation
Issued 5 March 1999
Resolved
Provide licenced operatorin a drug testing program and conduct fire and manoverboard drills prior to operating._x001C_
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Documentation
Issued 5 March 1999
Resolved
Post marpol placard for garbage and oil._x001C_
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Engineering
Issued 5 March 1999
Resolved
Mark winch control._x001C_
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Lifesaving
Issued 5 March 1999
Resolved
Post life jacket donning placard._x001C_
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Construction/Loadline
Issued 5 March 1999
Resolved
TEST FWD BILGE ALARM._x001C_
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999