Records from 1980 to 1993. Most recent: inspection, 12 August 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
12 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 846894
16 November 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 960475
11 June 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399772
29 June 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1253441
10 August 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 441148
10 August 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 468608
1 July 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1235530
21 June 1990
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1211753
15 June 1990
COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1238798
4 August 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 896776
26 July 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212020
10 June 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889132
4 June 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002809
3 April 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998542
13 March 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 981315
28 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973431
19 January 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971264
10 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965765
24 December 1980
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968864
Navigation
Issued 15 June 1990
Resolved
RENEW PIN BUSHING FOR STEERING GEAR CONNECTING LINKAGES.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Engineering
Issued 15 June 1990
Resolved
SECURE DECK PLATES & INSTALL MACHINERY GUARDS.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Lifesaving
Issued 15 June 1990
Resolved
INSTALL SPACERS & ATTACH OARS TO LIFEFLOATS.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Navigation
Issued 15 June 1990
Resolved
OBTAIN UP TO DATE U.S. COAST PILOT AND LIGHT LIST.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Engineering
Issued 15 June 1990
Resolved
INSTALL DOUBLE NUTS TO SHAFT PACKING GLANDS.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Construction/Loadline
Issued 15 June 1990
Resolved
ADJUST WATERTIGHT DOOR ON MAIN DECK & BRIDGE DECK AFT.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Documentation
Issued 26 July 1989
Resolved
PROVIDE STABILITY BOOKLET DATED 31OCT77 REVISED 29APR78 BEARING USCG APPROVAL STAMP DATED 05JUN78 (REF 46 CFR 93.01-1).
Condition: Unknown
Due 26 July 1989
Resolved 26 July 1989