10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 February 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Marine Inspector identified that the masthead light was inoperable. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 19 March 2025
Resolution: Provided photographs of operational masthead light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Marine Inspector identified that some waste receptacles on board the vessel were made of combustible materials. Replace waste receptacles with those constructed of noncombustible materials.
46 CFR 177.405(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 26 February 2025
Resolution: Sent documentation replacing waste receptacle.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 February 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retro reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring buoy missing reflective tape and was corrected during exam.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 20 February 2024
Resolution: Reflective tape applied during exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2023
Resolved
The bilge suctions shall be fitted with suitable
strainers having an open area not less than three times the area of the bilge pipe. ENG room bilge suction is insufficient size. Provide bilge suction strainer that meets this regulation to satisfaction of attending Marine Inspector.
46 CFR 182.25-5 (b) "OLD-T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 17 March 2023
Resolution: Installed acceptable bilge suction strainer in ENG room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 February 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Test strips on vessel are expired.
46 CFR 4.06-15
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 8 June 2023
Resolution: Alcohol test strips are readily accessible on board vessel.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 28 February 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel missing complete emergency instructions posted. Add missing heavy weather and man overboard instructions. 46 CFR 185.510 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 8 June 2023
Resolution: Sufficient emergency instructions posted.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 28 February 2023
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include - (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. OVBD Discharge is currently secured with a plastic tie wrap. Provide an acceptable method of securing the valve to satisfaction of attending Marine Inspector. 33 CFR 159.7 (c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 17 March 2023
Resolution: Secured OVBD discharge valve with locking shackle and chain in closed position.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 February 2023
Resolved
For a vessel described by 46 CFR175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include all items referenced in this part. Provide required training and log into vessels training/drills logs.
Federal Register/V.86 No. 245 46 CFR 185.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 8 June 2023
Resolution: Provided satisfactory evidence of required training and procedures into vessels log.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2022
Resolved
"All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment" Forward void missing bilge strainer. 46 CFR 182.25-1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2022
Resolved 5 April 2022
Resolution: Bilge strainer replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 March 2022
Resolved
"For fixed-gas fire extinguishing systems, the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector." Vessel missing documentation of Global Fire report. 46 CFR 176.810
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2022
Resolved 5 April 2022
Resolution: Vessel provided satisfactory report.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 17 March 2022
Resolved
"A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored and moored. The ground tackle must be satisfactory and subject to the approval of the cognizant OCMI." Corroded anchor chain shackle linkage. 46 CFR 184.200
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2022
Resolved 5 April 2022
Resolution: Vessel cleaned and provided evidence of satisfactory anchor chain shackle.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2022
Resolved
"All cable and wire must be installed in accordance with paragraph 14.h of ABYC E-8 and paragraph 15.h of ABCY E-9)." Multiple cable and wire transits connecting to battery bank. Current set up does not meet ABYC standards. 46 CFR 183.340
Submit plans to OCMI for plan review.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2022
Resolved 16 May 2022
Resolution: Vessel corrected electrical concerns IAW line drawing.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 30 March 2021
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Vessel's painter was improperly attached to the float free link for the inflatable buoyant apparatus.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2021
Resolution: Deficiency Corrected on the spot. Vessel corrected the rigging in accordance with manufacturer's instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 March 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Vessel's forepeak void did not have an audible bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2021
Resolution: Operator corrected the bilge alarm by adjusting its wiring. Bilge alarm now provides a visual and audible alarm at the bridge.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 30 March 2021
Resolved
Attachment plugs for portable lamps, tools, and similar apparatus operating at 100V or more, must have a grounding pole and a grounding conductor in the portable cord. Vessel's plug in 120V space heater in the accommodation space is not grounded and is unsuitable for marine application. 46 CFR 183.10-20(o).
Action required: 10 - Deficiency Rectified
Due 13 April 2021
Resolved 30 March 2021
Resolution: Operator removed the space heater from the vessel and will no longer use it onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 14 April 2020
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. COD on board listed vessel under previous name of New Salmon Queen and was expired.
46 CFR 67.313
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2020
Resolved 20 April 2020
Resolution: Provided picture of updated COD
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 April 2020
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. FCC radiotelephony did not have EPIRB listed as radio installations on board the vessel.
47 CFR 80.903
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2020
Resolved 28 May 2020
Resolution: Operator provided photo evidence of radiotelephony. Uploaded into documents tab.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 April 2020
Resolved
Man overboard drills and training shall be logged or otherwise documented at least once within a 3 month period. The drill entry shall include the date of the drill and training; and general description of the drill scenario and training topics.
46 CFR 185.520
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2020
Resolved 5 May 2020
Resolution: Operator sent picture of updated MOB drill log
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 April 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible. Vessel did not have up to date charts onboard.
46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2020
Resolved 5 May 2020
Resolution: Operator sent pictures of updated charts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2020
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light. 01 life jacket onboard was worn and inoperable.
46 CFR 180.75(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 May 2020
Resolved 16 April 2020
Resolution: Resolved on the spot with a replacement light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2019
Resolved
Flexible nonmetallic hose used in vital piping systems must meet SAE J-1942 or be specifically approved by the Commandant. The flexible fuel hoses and priming bulbs on the main engine fuel filters are not of an approved type. Remove permanent installation of hoses and install metallic cap to fitting to the satisfaction of the Marine Inspector.
46 CFR 182.720(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2019
Resolved 26 March 2019
Resolution: Received photograph of capped fuel manifold.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 March 2019
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. The strainers for the installed bilge system do not have an open area of three times the bilge pipe. Install bilge strainers that meet the requirements of 46 CFR 182.510 to the satisfaction of the Marine Inspector.
46 CFR 182.510(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2019
Resolved 10 April 2019
Resolution: Received photographs of replaced bilge strainers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2019
Resolved
An EAP training program must be conducted for the employer's crew members and supervisory personnel. The Captain did not receive at least 60 minutes of EAP training. Execute training requirements IAW 46 CFR 16.401 to the satisfaction of the Marine Inspector.
46 CFR 16.401(b)
Action required: 10 - Deficiency Rectified
Due 19 March 2019
Resolved 19 March 2019
Resolution: Operator conducted EAP training and provided proof of successful completion.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2019
Resolved
All marine employers must submit drug testing program data required by 49 CFR 40.26. The vessel could not provide proof of MIS submission. Provide proof that the MIS Data Collection Form IAW 46 CFR 16.500 has been submitted.
46 CFR 16.500(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2019
Resolved 16 May 2019
Resolution: Operator provided proof of submission via email to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 March 2019
Resolved
Each vessel certificated to operate on a coast wise route in cold water must be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 100% of the total persons permitted on board. As per the vessel's COI, the IBA on board only has a capacity to accommodate 71% of the total persons permitted on board. Provide survival craft to meet requirements of 46 CFR 180.204 by the next Annual Inspection. *Formal notification letter to follow.
46 CFR 180.204(b)
Action required: 705 - Other - as specified
Due 19 March 2020
Resolved 16 April 2020
Resolution: Amended COI to authorize 25 persons for oceans route; removed coastwise verbiage
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 June 2018
Resolved
Vessel's fixed bilge system is inoperable. 46 CFR 182.500
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2018
Resolved 25 June 2018
Resolution: Owner proved proper operation of the bilge system.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 June 2018
Resolved
Vessel does not have closure devices for supply duct openings for the engine room which is protected by a fixed gas fire extinguishing system. 46 CFR 182.465(h)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2018
Resolved 25 June 2018
Resolution: Vessel has securing devices for engine intake duct openings.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 June 2018
Resolved
Vessel does not have up to date charts onboard. 46 CFR 184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2018
Resolved 9 July 2018
Resolution: Vessel has up to date charts for operating area onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 June 2018
Resolved
Lighting fixtures are being used as connection boxes/outlet to supply other equipment. 46 CFR 183.410
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 25 June 2018
Resolution: Owner removed connection boxes from lighting fixtures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 June 2018
Resolved
The belt on the forward part of the port engine is exposed and is a hazard. 46 CFR 177.960
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 25 June 2018
Resolution: Guard was installed on port engine exposed belt.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2018
Resolved
Vessel has dead-end wiring throughout engine room. 46 CFR 183.340
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 25 June 2018
Resolution: Dead end wiring was removed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 June 2018
Resolved
Forward bulkhead in engine room has multiple holes and is not vapor tight. 46 CFR 177.405
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 25 June 2018
Resolution: Holes in the engine room bulkhead were made vapor tight.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 8 June 2018
Resolved
Master did not have Radio Operators Permit. 47 CFR 80.159
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2018
Resolved 12 July 2018
Resolution: Owner/Master has valid Radio Operators Permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 June 2018
Resolved
Vessel has expired Radiotelephony Certificate. 47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2018
Resolved 27 June 2018
Resolution: Valid radiotelephony certificate is onboard.
Operations/Management › Vessel Activity › Underway
Issued 4 May 2018
Resolved
Complete sea-trail after repower.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2018
Resolved 21 June 2018
Resolution: Vessel conducted satisfactory sea trials during Annual Inspection.
Engineering › Steering Gear System › Rudder Bearing
Issued 4 May 2018
Resolved
Tighten/repack starboard rudder post seal.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2018
Resolved 21 June 2018
Resolution: Starboard rudder post seal was fixed and showed no signs of leakage.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 May 2018
Resolved
Prove proper operation of engine shut down from fire system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2018
Resolved 21 June 2018
Resolution: Vessel proved proper operation of the engine shutdown from the vessel's pre-engineered fire system during Annual Inspection.
Construction/Loadline › Hull › Hull Plating
Issued 18 April 2018
Resolved
Vessel needs to complete dry dock exam. 46CFR176.600
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2018
Resolved 21 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 March 2017
Resolved
Properly secure dead end wires in engine room, cabin space, and forward compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 10 April 2017
Resolution: Received photos from vessel rep showing capped wires.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 28 March 2017
Resolved
Replace the following chafed/gouged flexible hoses on both engines: fuel injection, fuel return, raw water cooling.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 21 April 2017
Communications › Radio Communications › EPIRB
Issued 28 March 2017
Resolved
Provide proof of EPIRB registration sticker and affix to EPIRB.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 10 April 2017
Resolution: Vessel provided proof of sticker.