MAURY USCG vessel records Sign in
← All vessels

NEW HUCK FINN

NEW HUCK FINN is a 1977 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1984, most recently in March 2025, along with 196 deficiencies and 2 operational controls.

Records from 1984 to 2025. Most recent: inspection, 3 March 2025.

Built
1977
Last inspected
3 March 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN8040
Flag
UNITED STATES
366826890
Maury page id
psix-49123

Inspections, by type

…with no type recorded11
Years with a record 39 calendar years (1984–2025)
The 91 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)49.3 ft × 15.4 ft × 7.1 ft
Registered tonnagegross 45 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 10 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN8040MMSI 366826890 · active · compulsorily equipped · granted 13 May 2023, expires 13 May 2033
WDA6024MMSI 366826890 · expired · compulsorily equipped · granted 23 September 2011, cancelled 4 December 2021
WCP7931MMSI not assigned · expired · compulsorily equipped · granted 26 January 1995, cancelled 2 April 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JOHN O.K. Commercial Fishing Vessel · MISLE 59772 · 25 July 1993 · activity 65741JOHN O.K. Commercial Fishing Vessel · MISLE 59772 · 25 July 1993 · activity 104260STAR OF THE SEA Commercial Fishing Vessel · MISLE 69057 · 25 July 1993 · activity 104260

Inspection history · 91

3 March 2025 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8083719
6 January 2025 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043736
12 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7866222
6 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7662150
15 March 2023 Deficiency Check · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7651351
2 March 2023 In-Service Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7644629
13 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608577
28 February 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7403352
4 January 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7375393
10 April 2021 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 7172660
24 March 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7162204
20 January 2021 Hull Examination · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7127714
6 January 2020 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6883380
16 April 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6663969
4 March 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6635913
3 April 2018 Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6384447
6 April 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6118282
3 February 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6082595
17 March 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5834820
12 March 2014 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4817953
6 February 2012 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4266858
3 February 2012 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4237663
29 December 2011 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 4216089
1 December 2011 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4220165
1 December 2010 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3902183
10 March 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3692797
1 April 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3437161
11 February 2009 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3402240
13 March 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3155911
21 May 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2936635
8 May 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2925336
30 March 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2896936
2 March 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2880898
13 December 2005 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2547267
14 April 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2333677
30 March 2005 Hull Examination · Simplified Stability Test · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2321292
3 February 2005 Plan Review "T" Boat · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2286228
4 January 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2268718
13 January 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1975194
7 April 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1769667
18 March 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1752429
11 December 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1716694
6 December 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1382457
2 February 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1393332
23 February 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 799897
21 January 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805665
15 December 1998 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 809067
17 December 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1368528
13 February 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1107270
19 December 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1359319
6 December 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1411387
14 December 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 881569
12 April 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1155484
17 March 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 867404
16 December 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858354
16 December 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1160050
7 July 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1163752
1 March 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 853777
31 January 1994 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 852715
19 January 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658408
8 January 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 83574
8 January 1994 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1161178
7 January 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 119808
14 December 1993 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 849838
14 December 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1159840
27 July 1993 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156507
25 July 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 65741
25 July 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 104260
30 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140196
14 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 831107
11 December 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 831356
10 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1137729
1 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1143165
19 November 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 826519
30 July 1992 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1013215
8 January 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1262667
19 February 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 917217
19 February 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 925827
8 January 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1215720
12 January 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 917159
14 December 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 899569
1 February 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1209300
9 January 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1199624
19 January 1988 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012555
6 January 1988 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1317336
12 January 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1313059
8 January 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1313058
9 January 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1302945
18 December 1985 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1301621
18 January 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 980823
23 October 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 979037

Deficiency record · 196

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 January 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2025
Resolved 7 January 2025
Resolution: Vessel rep sent photo of updated FCC Station Authorization.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 March 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of fixed gas fire extinguishing system. During operational test of engine room pre-engineered fire fighting system, engines were unable to restart when activating the override function.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2024
Resolved 27 March 2024
Resolution: Visually verified override function of the vessel's engines.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical distribution panel in wheelhouse is missing labels for several breakers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2024
Resolved 27 March 2024
Resolution: Verified missing labels for breakers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in the spaces provided in 46 CFR 182.530(a). The vessel's audible alarm was not functioning.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 26 March 2024
Resolved 26 March 2024
Resolution: Issue resolved during exam.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 6 April 2023 Resolved
For a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include, but need not be limited to— (1) Training in the use and location of firefighting equipment and general firefighting knowledge, including: (i) Location of firefighting appliances and emergency escape routes; (ii) Types and sources of ignition; (iii) Flammable materials, fire hazards and spread of fire; (iv) The need for constant vigilance; (v) Actions to be taken on board; (vi) Fire and smoke detection and automatic systems on board; and (vii) Classification of fire and applicable extinguishing agents. Provide required crew training and document in drill log. 46 CFR 185.420 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2023
Resolved 13 May 2023
Resolution: Provided required crew training and documented in vessels log.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 April 2023 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessels FCC station license is expired. Provide proof of current, vailid Station License. 47 CFR 80.13 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2023
Resolved 13 May 2023
Resolution: Renewed and installed valid FCC station license on board vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 April 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. The following contents are expired: Eyewash saline, Aspirin. Provide first-aid kit with servicible contents. 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2023
Resolved 25 April 2023
Resolution: Replaced eyewash and aspirin.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 4 January 2022 Resolved
Fuel cocks are prohibited for use in fuel lines except those of the solid bottom type with tapered plugs and union bonnets. The vessel did not have the approved fuel cocks connected to its fuel filters. 46 CFR 182.20-40 (a)(4)(OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 13 January 2022
Resolution: The vessel removed the fuel cock from the fuel filter and installed plug.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 January 2022 Resolved
Machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads. Engine room had a sewage holding tank vent pipe that penetrated the watertight bulkhead that needs vapor seal. 46 CFR 182.35-1(a)(OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 12 January 2022
Resolution: Vessel operator sent in pictures of the connected piping to maintain vaportight integrity of the bulkhead.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 January 2022 Resolved
On a vessel of at least 26 ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. The bilge high level alarms did not indicate which space the high level alarm was going off on. 46 CFR 182.530(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 13 January 2022
Resolution: Picture received for rectifying the deficiency. Uploaded to vessel deficiencies documents folder.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 4 January 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The starboard fuel tank vent pipe did not have a removable flame screen. 46 CFR 182.450(e)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 12 January 2022
Resolution: Vessel operator sent in a picture with a newly installed flame screen.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 4 January 2022 Resolved
Vessels operated beyond the 20 nautical mile limitation, but not more than 100 nautical miles from the nearest land, must be equipped with a Medium Frequency- Digital Selective Calling frequency transmitter. The vessel did not have the corresponding MMSI number programmed within the radio to ensure proper DSC transmission. 47 CFR 80.905(a)(2)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2022
Resolved 28 February 2022
Resolution: Received photo of newly installed radio.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock, and minimize accidental personnel contact with energized parts. Dead end wire on PME Alternator. Remove unused wire or connect to adequate equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 11 May 2021
Resolution: Operator sent picture of properly installed wire connected to PME alternator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Broken outlet cover in aft Engine Room Space. Fix outlet cover. 46 CFR 183.200 (b)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 11 May 2021
Resolution: Operator sent picture of newly installed outlet cover in aft engine room space.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 April 2021 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected al required guards and protective devices must be in satisfactory condition. Excessive amounts of oil seen leaking from PME and SME on fuel injector lines. Determine source of oil and prevent further discharge. 46 CFR 176.830 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 11 May 2021
Resolution: Operator sent pictures of fuel injector lines on both SME and PME. No oil leaks present.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 January 2021 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against personnel injury. Discovered missing guard over gear driven electric clutch washdown pump on port engine, presenting a potential safety hazard to the crew.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 February 2021
Resolved 5 February 2021
Resolution: Washdown PTO pump guard installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2021 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Discovered exposed wires in fwd engine room and center compartment, presenting potential hazards to crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2021
Resolved 5 February 2021
Resolution: Verified owner removed dead-end electrical wires.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 January 2020 Resolved
Each window and its attachment to the deckhouse, must be capable of withstanding the maximum load from wave and wind conditions. Port forward and aft window on deckhouse is cracked. Replace window with glass or other glazing material that will not break into dangerous fragments if fractured. 46 CFR 177.1020
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 16 March 2020
Resolution: Cracked window replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2020 Resolved
All cable and wire must be installed with metal supports not spaced more than 24 inches apart. Wires in center compartment space is hanging and is required to be adequately supported. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 16 March 2020
Resolution: Cable supported by metallic clamps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2020 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] for light over SSDG is loosely installed causing the light to go on and off when touched. 46CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 16 March 2020
Resolution: Cable properly installed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 January 2020 Resolved
Vapor Barriers must be provided in spaces where vapors are present such as a machinery space. Aft bulkhead port side of Engine room has two inch hole in bulkhead. Seal hole to make vapor tight. 46 CFR 177.405 (e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 16 March 2020
Resolution: Firestop added to engine room bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2020 Resolved
Each Life Jacket must be marked with Type I retroflective material approved in 46 CFR 164.018. 5 Adult life jacket retroflective tape is worn. 46 CFR 185.604 (h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 16 March 2020
Resolution: Retroflective tape replaced on identified life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Two Kapok life jackets were not serviceable. 46 CFR 180.71 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2020
Resolved 8 January 2020
Resolution: Two new adult life jackets provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2019 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Vessel has installed "loose" 12V bait pump switch (main cabin below decks) in wiring secured with a copper conductor strap. Vsl should use switch box or fabricate panel for mounting switch safely using proper connectors.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 April 2019
Resolved 16 April 2019
Resolution: Vsl submitted photo of switch mounted to self fabricated panel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 April 2019 Resolved
Ring life buoys: A vessel must carry one floating waterlight. Vessel's waterlight does NOT float. Vessel needs to replace or repair floating waterlight.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 April 2019
Resolved 16 April 2019
Resolution: Cleared. Vsl submitted video of strobe floating at basin.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2019 Resolved
When a marine employer determines that a casualty or incident is, or is likely to become, an SMI, the marine employer must ensure that alcohol and drug testing is conducted (alcohol testing of an individual must be conducted within 2 hours of when the SMI occurred). No alcohol testing strips onboard during inspection. Vsl on 100 mile oceans route, should carry alcohol test strips onboard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 April 2019
Resolved 16 April 2019
Resolution: Vsl submitted photo of test strips.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 April 2019 Resolved
As appropriate for the intended voyage, a vessel must carry Charts, Coast Pilot [name withheld] and Inland Nav Rules. All found to be were dated (2015-16, and Inland Rules version B). Vsl needs to update charts and publications.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2019
Resolved 28 April 2019
Resolution: Received photo of Coast Pilot [name withheld] and Inland Nav Rules.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 April 2017 Resolved
Secure/remove dead end wiring on bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 17 April 2017
Resolution: Removed dead end wiring.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 April 2017 Resolved
Replace worn emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 17 April 2017
Resolution: Replaced emergency broadcast placard.
Lifesaving › Lifebuoys › Stowage
Issued 6 April 2017 Resolved
Change stowage location of ring buoy to a space where it is readily accessible and stowed in a way that it can be rapidly cast loose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 6 April 2017
Resolution: Changed location of ringbuoy to front of bridge near operaters station.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 April 2017 Resolved
Store all lifejackets in passenger accessible space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 6 April 2017
Resolution: Shifted passenger lifejackets to in cabin vice in crew space.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 March 2016 Resolved
Vessel route is restricted to within 20nm of shore until the single side band is onboard and operational. 47CFR80.905 & 80.913
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 10 April 2017
Resolution: Provided servicing report for single side band radio.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 March 2014 Resolved
Provide one Type 1 child PFD in accordance with COI.
Due 31 March 2014
Resolved 13 March 2014
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 March 2014 Resolved
Provide proof of DAPI program
Due 31 March 2014
Resolved 13 March 2014
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 March 2014 Resolved
Provide alcohol test strips
Due 31 March 2014
Resolved 26 March 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 March 2014 Resolved
Provide eye wash solution and ammonia inhalant sticks
Due 31 March 2014
Resolved 26 March 2014
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 March 2014 Resolved
Replace marine type light bulb on anchor light.
Due 31 March 2014
Resolved 13 March 2014
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 12 March 2014 Resolved
Provide proof of service report for IBA and new hydrostatic release.
Due 31 March 2014
Resolved 20 March 2014
Operations/Management › Equipment Service/Testing › EPIRB
Issued 12 March 2014 Resolved
Provide proof of new hydrostatic release for EPIRB. Limited vessel's route to no more than 3 NM offshore.
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 20 March 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 March 2014 Resolved
Provide proof service report for engine room pre-engineered system and all onboard portable extinguishers.
Due 31 March 2014
Resolved 20 March 2014
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 12 March 2014 Resolved
Provide certificate of completion for CPR course
Due 31 March 2014
Resolved 2 April 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 February 2012 Resolved
Provide iodine swabs and ammonia inhalants in first aid kit.
Condition: Placed in Improper Service
Due 3 March 2012
Resolved 23 April 2012
Resolution: Vessel representative provided iodine swabs and ammonia inhalants to first aid kit.
Documentation › Certificates/Documents › FCC SSL
Issued 3 February 2012 Resolved
Provide copy of FCC safety certificate that is current.
Condition: Invalid
Due 3 March 2012
Resolved 23 April 2012
Resolution: A current FCC safety certificate was onboard.
Engineering › Fuel Oil Service System › Filter
Issued 3 February 2012 Resolved
Install plug or cap on drain valves for generator fuel filters.
Condition: Improper Installation
Due 3 March 2012
Resolved 23 April 2012
Resolution: Installed the correct plug on the fuel filter.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 3 February 2012 Resolved
Properly bond fill ines for both fuel tanks.
Condition: Design Flaw
Due 3 March 2012
Resolved 23 April 2012
Resolution: Both fill lines for fuel tanks were properly bonded.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 3 February 2012 Resolved
Install plug or cap on day tank drain valve.
Condition: Design Flaw
Due 3 March 2012
Resolved 23 April 2012
Resolution: Installed the correct valve on the day tank.
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 February 2012 Resolved
Conduct annual inspection underway drills witnessed by USCG marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2012
Resolution: Conducted underway drills and exercises.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 December 2010 Resolved
Provide 9 Type I adult lifejackets w/markings and light. Limited to 40 adult passengers until corrected.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator provided 9 new type I lifejackets with markings and lights.
Documentation › Certificates/Documents › FCC SSL
Issued 1 December 2010 Resolved
Provide valid FCC Safety Radiotelephone Certificate.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 21 December 2010
Resolution: Operator provided valid FCC Safety Radiotelephone Certificate
Lifesaving › Lifefloat › Lifeline
Issued 1 December 2010 Resolved
Provide secure lifefloat lifeline attachment points equivalent to original in strength and number.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator provided acceptable secure attachment points for the lifeline that are equivalent to original strength and number.
Engineering › Sea-water System (primary cooling) › Valve
Issued 1 December 2010 Resolved
Renew SW isolation valve in fwd compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator renewed SW isolation valve in fwd compartment. Tested sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2010 Resolved
Remove extension cord for deck light and provide permanent marine grade wiring.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator removed extension cord and re-wired using marine grade wiring.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2010 Resolved
Properly hung waires above port main engine.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator properly hung wires above port main engine.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 1 December 2010 Resolved
Close protective cover on battery charger.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator properly closed the protective cover on the battery charger.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 December 2010 Resolved
Provide face-plate cover for electrical outlet box in machinery space.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator provided face plate for electrical outlet box.
Engineering › Bilge Water Management System › Pump
Issued 1 December 2010 Resolved
Securely mount/affix electric submersible bilge pump in sewage compartment.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator properly affixed bilge pump to vessel''s hull.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 1 December 2010 Resolved
Provide lable for lifejacket storage in crew cabin.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator provided label indicating type and number of lifejackets stored in crew cabin.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 1 December 2010 Resolved
Renew flex hose couplings on both main engine jacket water systems (red hoses). Replace with mfr recommended hose type.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 10 December 2010
Resolution: Operator took flex hoses to mfr rep at KKMI and was informed that the hoses were functioning correctly and were part of the air intake, and not jacket water.
Construction/Loadline › Structures › Superstructure
Issued 1 December 2010 Resolved
Provide total weight of crab block hydraulic system including tank, hoses, and frame.
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 20 December 2010
Resolution: Operator provided weights and installation details for the crab block hydraulic system.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 April 2009 Resolved
O/O unable to locate COD.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2009
Resolved 1 April 2009
Resolution: Spoke with the documentation center and they stated that his DOC is valid thru May 2009.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 1 April 2009 Resolved
Provide proof of Consortium enrollment.
Condition: Unknown
Due 1 May 2009
Resolved 1 April 2009
Resolution: Corrected
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 1 April 2009 Resolved
Provide evidence of monthly Epirb testing.
Due 1 May 2009
Resolved 1 April 2009
Resolution: Corrected
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 April 2009 Resolved
Provide up to date coast pilot.
Condition: Unknown
Due 1 May 2009
Resolved 1 April 2009
Resolution: Corrected
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 April 2009 Resolved
Double clamp through hull flex hoses for the bait pump and head pump.
Condition: Improper/Lack of Maintenance
Due 1 May 2009
Resolved 1 April 2009
Resolution: Corrected
Electrical › Electric Supply System (service) › Cable
Issued 1 April 2009 Resolved
Remove old loose, bare bonding wire from generator flat.
Condition: Improper Installation
Due 1 May 2009
Resolved 1 April 2009
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 March 2008 Resolved
Remove non-marine grade cable to water heater or install with marine grade cable IAW 33 CFR part 183
Due 14 March 2008
Resolved 13 March 2008
Resolution: Corrected on the spot.
Engineering › Bilge Water Management System › Pump
Issued 13 March 2008 Resolved
Repair Lazzarette bilge pump.
Due 14 March 2008
Resolved 13 March 2008
Resolution: Corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 March 2008 Resolved
Repair mast head light.
Due 14 March 2008
Resolved 13 March 2008
Resolution: Corrected on the spot.
Lifesaving › Hand Flares › Expired
Issued 13 March 2008 Resolved
Replace three expired red flares.
Due 14 March 2008
Resolved 13 March 2008
Resolution: Corrected on the spot.
Stability › Watertight Integrity › General
Issued 30 March 2007 Resolved
Found two watertight penetrations on the forward engine room bulkhead not watertight. Make bulkhead penetrations watertight. Corrected on the spot.
Due 30 March 2007
Resolved 30 March 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 30 March 2007 Resolved
Provide proof of NOAA registration for EPIRB.
Due 30 April 2007
Resolved 21 May 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 30 March 2007 Resolved
Make available to attending marine inspector current log entries of training and lifesaving equipment maintenance by next annual exam.
Due 13 December 2007
Resolved 13 March 2008
Engineering › Bilge Water Management System › Piping
Issued 19 December 2005 Resolved
Install 2 metallic shutoff valves for fwd accommodation space bilge through bulkhead piping in accordance with 46 CFR 182.720.
Due 20 February 2006
Resolved 2 March 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 December 2005 Resolved
Renew Electrical outlet cover in the center hold In accordance with 46 CFR 183.220 (General safety provisions)
Due 13 January 2006
Resolved 21 December 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 13 December 2005 Resolved
Provide a means to secure sewage overboard valve in the Closed (Locked) position IAW: 33 CFR 159.53
Due 13 January 2006
Resolved 21 December 2005
Engineering › Bilge Water Management System › Valve
Issued 13 December 2005 Resolved
Replace Lazarette bilge overboard positive shutoff valve with metallic positive shut off valve.
Due 13 January 2006
Resolved 21 December 2005
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 13 December 2005 Resolved
Provide documentation verifying supervisor received 1 hour EAP training.
Due 13 January 2006
Resolved 9 January 2006
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 13 December 2005 Resolved
Provide proof of MIS submission to the Coast Guard.
Due 13 January 2006
Resolved 9 January 2006
Navigation › Piloting/Steering › Marine Charts
Issued 7 April 2005 Resolved
Provide on board updated navigational charts for the vessel routes.
Due 29 April 2005
Resolved 14 April 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 April 2005 Resolved
Provide on board current applicable sections of Coast pilot.
Due 29 April 2005
Resolved 14 April 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 April 2005 Resolved
Provide on board cuurnt applicable sections of USCG Light list.
Due 29 April 2005
Resolved 14 April 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 April 2005 Resolved
Demonstrate man overboard and fire drill.
Due 29 April 2005
Resolved 14 April 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 7 April 2005 Resolved
Provide proof of employee enrollment in mandatory drug testing program.
Due 14 April 2005
Resolved 14 April 2005
Lifesaving › Hand Flares › Not on Board
Issued 7 April 2005 Resolved
Provide on board 3 hand held day/night red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 April 2005 Resolved
Renew batteries for all life jacket lights.
Due 29 April 2005
Resolved 14 April 2005
Lifesaving › Visual Distress Signals (General) › Condition
Issued 7 April 2005 Resolved
Renew batteries for life float and life bouy float lights.
Due 14 April 2005
Resolved 14 April 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 April 2005 Resolved
Provide on board Lifesaving equipment maintenance log.
Due 14 April 2005
Resolved 14 April 2005
Communications › Radio Communications › EPIRB
Issued 7 April 2005 Resolved
Provide and properly install new EPIRB hydrostatic release mechanism with valid expiration date. Vessel is restricted to operations not more than 3 miles from shore until corrected.
Action required: 705 - Other - as specified
Resolved 14 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 April 2005 Resolved
Provide on board aspirin with valid expiration date.
Due 14 April 2005
Resolved 14 April 2005
Stability › Unintentional Flooding › General
Issued 3 February 2005 Resolved
Operator shall install metallic thru hull fitting for galley sink overboard located starboard side amidshipsin accodance with 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 3 February 2005
Engineering › Bilge Water Management System › Piping
Issued 3 February 2005 Resolved
Operator shall make the installed bilge piping/system comply with 46 CFR 182.710 and 46 CFR 182.720 in way of PVC piping that penetrates water tight bulkheads.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 14 April 2005
Construction/Loadline › Hull › Hull Plating
Issued 4 January 2005 Resolved
Vessel must be hauled out for credit dry dock exam prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2005
Resolved 3 February 2005
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 January 2004 Resolved
Replace expired contents of the first aid kit and make water tight. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 31 January 2004
Resolved 5 February 2004
Operations/Management › Drug and Alcohol Testing
Issued 13 January 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 31 January 2004
Resolved 19 February 2004
Construction/Loadline › Structures
Issued 18 March 2003 Resolved
Repair as new, aft pilot house window. LEGACY COMPONENT DESC: Superstructure
Due 18 April 2003
Resolved 18 March 2003
Navigation › Piloting/Steering
Issued 18 March 2003 Resolved
Provide corrected chart for operating area. LEGACY COMPONENT DESC: Marine Charts
Due 18 April 2003
Resolved 3 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 18 March 2003 Resolved
Provide alternator belt guard for stbd main engine. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 18 April 2003
Resolved 3 April 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 18 March 2003 Resolved
Repair as new Port and Stbd fuel tank supply valves in way of leak. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2003
Engineering › Sea-water System (primary cooling)
Issued 18 March 2003 Resolved
Renew as original raw water supply and discharge hoses for port and stbd engines in way of engine room and tank space. LEGACY COMPONENT DESC: Piping
Due 18 April 2003
Resolved 3 April 2003
Lifesaving
Issued 18 March 2003 Resolved
Label all float lights with battery expiration dates.
Due 18 April 2003
Resolved 3 April 2003
Lifesaving › Lifebuoys
Issued 18 March 2003 Resolved
Provide detachable corrrosion resistant clip for ringbuoy float light. LEGACY COMPONENT DESC: Self-igniting Lights
Due 18 April 2003
Resolved 3 April 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 18 March 2003 Resolved
Provide approved fire extinguisher brackets for four B-II fire extinguishers. LEGACY COMPONENT DESC: Mounting Bracket
Due 18 April 2003
Resolved 3 April 2003
Construction/Loadline › Structures
Issued 18 March 2003 Resolved
Attach lanyard to hatch in way of lazarette scuttle. LEGACY COMPONENT DESC: Scuttle
Due 18 April 2003
Resolved 3 April 2003
Stability › Watertight Integrity
Issued 18 March 2003 Resolved
Make collision bulkhead watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2003
Engineering › Bilge Water Management System
Issued 18 March 2003 Resolved
Provide plans for installation of bilge alarm and pump in way of lazarette. LEGACY COMPONENT DESC: Pump
Due 18 April 2003
Resolved 3 April 2003
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 March 2003 Resolved
Repair as new automatic shut down for port MDE in way of fixed fire extinguishing system.
Due 18 March 2003
Resolved 18 March 2003
Unknown
Issued 2 February 2000 Resolved
Prior to carrying passengers for hire conduct fire and abandon ship drills to the satisfaction of the attending inspector.
Condition: Unknown
Due 2 February 2000
Resolved 2 February 2000
Navigation
Issued 2 February 2000 Resolved
Provide onboard a current Chart of the San Francisco Bay.
Condition: Unknown
Due 2 February 2000
Resolved 2 February 2000
Lifesaving
Issued 2 February 2000 Resolved
Replace expired hydrostatic release on the EPIRB.
Condition: Unknown
Due 2 February 2000
Resolved 2 February 2000
Lifesaving
Issued 19 December 1996 Resolved
REPAIR/PATCH SMALL HOLES IN LIFELOATS.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Lifesaving
Issued 19 December 1996 Resolved
PROVIDE PLACARD FOR CHILD PFD STOWAGE AREAS.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Documentation
Issued 19 December 1996 Resolved
PROVIDE PROOF OF CURRENT RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Engineering
Issued 19 December 1996 Resolved
REPLACE HANDLES FOR REMOTE FUEL SHUTOFFS AND DEMONSTRATE OPERATION.
Condition: Unknown
Due 25 December 1996
Resolved 19 December 1996
Electrical
Issued 19 December 1996 Resolved
PROVIDE AMMETER, VOLTMETER AND HERTZ METER PER 46 CFR 183.320(c).
Condition: Unknown
Due 19 December 1996
Resolved 19 December 1996
Construction/Loadline
Issued 19 December 1996 Resolved
MAKE AFT ENGINE ROOM BULKHEAD WATERTIGHT AROUND WIRE WAYS.
Condition: Unknown
Due 18 January 1997
Resolved 19 December 1996
Engineering
Issued 6 December 1996 Resolved
PROVIDE PICTURES OF REPAIR TO CRACKED AREAS ON STARBOARD RUDDER AND OF INSTALLED PROPELLERS.
Condition: Unknown
Due 6 December 1996
Resolved 6 December 1996
Construction/Loadline
Issued 6 December 1996 Resolved
TREAT FURRING ON 2 LONGITUDINAL DECK SUPPORT BEAMS IN ENGINEROOM.
Condition: Unknown
Due 6 January 1997
Resolved 20 December 1996
Navigation
Issued 16 December 1994 Resolved
REPLACE BROKEN LENS COVER ON PORT RUNNING LIGHT, PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 12 January 1995
Resolved 9 January 1995
Construction/Loadline
Issued 16 December 1994 Resolved
REPAIR AND MAKE WEATHERTIGHT FORWARD HATCH COVER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 January 1995
Resolved 9 January 1995
Engineering
Issued 16 December 1994 Resolved
REINSTALL PROPELLERS FOR INSPECTION PRIOR TO LAUNCHING
Condition: Unknown
Due 12 January 1995
Resolved 10 January 1995
Construction/Loadline
Issued 16 December 1994 Resolved
RENEW IN KIND DECK BEAM IN OVERHEAD IN ENGINE ROOM, STARBOARD SIDE, THIRD BEAM FROM AFT
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Construction/Loadline
Issued 16 December 1994 Resolved
MAKE WATERTIGHTSEAM IN DECK AROUNG WATERTIGHT HATCH TO STEERING COMPARTMENTAND REATTACH KEEPER CHAIN PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 12 January 1995
Resolved 9 January 1995
Engineering
Issued 16 December 1994 Resolved
REPLACE MISSING HOSE CLAMPS ON EXHAUST SYSTEM HOSES PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 12 January 1995
Resolved 9 January 1995
Electrical
Issued 16 December 1994 Resolved
PROVIDE GLASS GLOBES AND CAGES FOR ALL LIGHT FIXTURES IN ENGINE ROOM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Construction/Loadline
Issued 16 December 1994 Resolved
MAKE WATERTIGHT HULL AND DECK JOINT ON MAIN DECK FROM ENGINE ROOM TO TRANSOM
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Construction/Loadline
Issued 16 December 1994 Resolved
MAKE WATERTIGHT ACCESS PORT ON MAIN DECK IN WAY OF PORT MDE
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Construction/Loadline
Issued 16 December 1994 Resolved
TREAT FURRING IN ENGINE ROOM
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Accommodation/Occupational Safety
Issued 16 December 1994 Resolved
SEAL TOP EDGE OF FIRST WINDOW, STARBOARD SIDE ACCOMMODATION SPACE
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Construction/Loadline
Issued 16 December 1994 Resolved
MAKE WATERTIGHT BULKHEAD IN WAY OF ENGINE ROOM AND AFT STEERING COMPARTMENTPRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 12 January 1995
Resolved 9 January 1995
Construction/Loadline
Issued 16 December 1994 Resolved
SEAL OPENINGS IN HULL CAUSED BY REMOVAL OF BAIT TANK OVERFLOWS, PORT AND STARBOARD, IN AFT STEERING COMPARTMENT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 January 1995
Resolved 9 January 1995
Accommodation/Occupational Safety
Issued 16 December 1994 Resolved
CHAIN AND LOCK MSD DISCHARGE.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 16 December 1994 Resolved
PROVIDE FLAME INPINGEMENT BOWL FOR RACOR FUEL FILTER OR SPIN ON FILTER FOR GENERATOR SET.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 16 December 1994 Resolved
PROVIDE BELT GUARD FOR PORT SIDE ENGINE PTO.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Documentation
Issued 16 December 1994 Resolved
PROVIDE FCC RADIOTELEPHONY SAFETY CERTIFICATE AND SHIP & AIRCRAFT STATION LICENSE. INSPECTOR WILL ACCEPT APPLICATION MADE TO FCC FOR THESE DOCUMENTS.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Documentation
Issued 16 December 1994 Resolved
PROVIDE AMPLYFYING INFO FOR DRUG TEST PROGRAM OUTLINING PERIODIC, REASONABLE CAUSE, AND POST CASUALTY TESTING. LIST PORT MEDICAL AS MRO AND COLLECTION SITE, AND NATIONAL REFERENCE LAB AS NIDA APPROVED.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Lifesaving
Issued 16 December 1994 Resolved
ON LIFEFLOATS PROVIDE a) GRAB LINES FOR BOTH, b) ATTACH BOTH L/F'S AND HAVEONE PAINTER WITH SINGLE WEAK LINK, c) PROVIDE MARKED WEAK LINK (RATED 21+),d) PROVIDE SLATS BETWEEN L/F'S, e) MARK OARS WITH VESSEL'S NEW NAME AND ATTACH TO L/F'S.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Electrical
Issued 16 December 1994 Resolved
PROVE PROPER OPERATION OF LIGHT FIXTURE, PORTSIDE OUTBOARD OF PORT ENGINE.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Electrical
Issued 16 December 1994 Resolved
INSTALL GROMET TO WIRE RUNNING OUT OF BATTERY CHARGER.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Navigation
Issued 16 December 1994 Resolved
PROVIDE COPY OF RULES OF THE ROAD.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 16 December 1994 Resolved
PROVIDE LOW DUCTING FOR ENGINE ROOM.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Engineering
Issued 16 December 1994 Resolved
PULL BACK LAGGING AND INVESTIGATE POSSIBLE LEAK WHERE EXHAUST PIPING TEES INTO WATER DISCHARGE ON PORT ENGINE. PROVE NO EXHAUST LEAK EXISTS. MAY BE FROM WATER LEAK THROUGH DECK ABOVE PORT ENGINE.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Electrical
Issued 16 December 1994 Resolved
REWIRE AND PERMANENTLY ATTACH STARTER SWITCH FOR GENERATOR SET.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Construction/Loadline
Issued 8 January 1994 Resolved
MAKE PERMANENT REPAIRS TO GEL COAT DAMAGE TO BOW.
Condition: Unknown
Due 8 January 1994
Resolved 8 January 1994
Construction/Loadline
Issued 8 January 1994 Resolved
REPAIR RAILING TO BOW.
Condition: Unknown
Due 8 January 1994
Resolved 8 January 1994
Construction/Loadline
Issued 8 January 1994 Resolved
CROP OUT TO GOOD MATERIAL AND MAKE PERMANENT REPAIRS TO 12" X 12" AREA LOCATED 4" FROM THE BOW ON THE PORT SIDE.
Condition: Unknown
Due 8 January 1994
Resolved 8 January 1994
Construction/Loadline
Issued 14 December 1993 Resolved
REPAIR OR REPLACE DOGGING APPARATUS TO LAZARETTE HATCH TO RETURN HATCH TO FULL WATERTIGHT FUNCTION.
Condition: Unknown
Due 31 December 1993
Resolved 27 December 1993
Navigation
Issued 14 December 1993 Resolved
REPLACE2 CHAFED HYDRAULIC HOSES IN AUTOPILOT FEED TO STEERING RAM IN LAZARETTE. HOSES MUST MEET SAE J1942 STANDARD FOR HYDRAULIC SERVICE.
Condition: Unknown
Due 31 December 1993
Resolved 27 December 1993
Engineering
Issued 11 December 1992 Resolved
REPAIR JACKET WATER LEAK ON STBD MAIN ENGINE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Electrical
Issued 11 December 1992 Resolved
BLOCK AND BRACE BATTERIES.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Engineering
Issued 11 December 1992 Resolved
REPAIR AND PROVE OPERATION OF PORT FUEL OIL EMERGENCY SHUT-OFF PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Construction/Loadline
Issued 11 December 1992 Resolved
SEAL DECK FITTINGS AS FOLLOWS; 1) PORT AND STBD FUEL OIL SHUT-OFFS 2) BAIT TANK DRAIN. ALL THREE SPOTS ARE LEAKING INTO ENGINE ROOM.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Unknown
Issued 19 November 1992 Resolved
REMOVE ALL OIL FROM ENGINE ROOM BILGE PRIOR TO LEAVING DRYDOCK.
Condition: Unknown
Due 14 December 1992
Resolved 10 December 1992
Engineering
Issued 19 November 1992 Resolved
PROVE FIBERGLASS REPAIR OF PORT ENGINE EXHAUST PIPE INWAY OF AFT E/R BULKHEAD.
Condition: Unknown
Due 15 December 1992
Resolved 10 December 1992
Construction/Loadline
Issued 19 November 1992 Resolved
REMOVE BLISTERS FROM HULL PRIOR TO DEPARTING DRYDOCK.
Condition: Unknown
Due 15 December 1992
Resolved 1 December 1992
Construction/Loadline
Issued 30 July 1992 Resolved
PROVIDE PROPER SEAL IN OPENING ON COLLISSION BULKHEAD BELOW BULKHEAD DECK.
Condition: Unknown
Due 30 August 1992
Resolved 10 August 1992
Unknown
Issued 8 January 1992 Resolved
PROVIDE WASTE DISPOSAL PLAN.
Condition: Unknown
Due 16 February 1992
Resolved 16 January 1992
Lifesaving
Issued 8 January 1992 Resolved
MOUNT RING LIFE BUOY ON WEATHER DECK.
Condition: Unknown
Due 16 February 1992
Resolved 16 January 1992
Fire Fighting
Issued 8 January 1992 Resolved
PROVIDE ONE BI TYP FIRE EXTINGUISHER IN THE WHEEL HOUSE OF VSL.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Construction/Loadline
Issued 8 January 1992 Resolved
PROVIDE VISUAL ACCESS TO VESSEL BOTTOM IN FORWARD COMPARTMENT.
Condition: Unknown
Due 16 February 1992
Resolved 16 January 1992
Electrical
Issued 8 January 1992 Resolved
PROVIDE GLASS COVER FOR LIGHT FIXTURE IN WAY OF STBD ENGINE.
Condition: Unknown
Due 16 February 1992
Resolved 16 January 1992
Lifesaving
Issued 8 January 1992 Resolved
ATTACH PADDLES TO LIFE FLOATS.
Condition: Unknown
Due 16 February 1992
Resolved 16 January 1992
Unknown
Issued 8 January 1992 Resolved
PROVIDE LETTER DESIGNATING SENIOR DECK HAND(S).
Condition: Unknown
Due 16 February 1992
Resolved 16 January 1992
Unknown
Issued 8 January 1992 Resolved
PROVIDE PROOF OF CURRENT, RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 16 February 1992
Resolved 16 January 1992
Lifesaving
Issued 8 January 1992 Resolved
REPLACE WASTED LINE FESTOONED ON LIFE FLOAT. LINE MUST BE REPLACED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 16 February 1992
Resolved 16 January 1992
Lifesaving
Issued 8 January 1991 Resolved
STENCIL LIFEFLOAT PADDLES WITH VESSELS NAME.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Lifesaving
Issued 8 January 1991 Resolved
PROVIDE BRACKET AND MOUNT LIFE BUOY ON OPEN DECK WHERE ACCESSIBLE.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Fire Fighting
Issued 8 January 1991 Resolved
SERVICE B1 PORTABLE FIRE EXTINGUISHER IN WHEELHOUSE.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Electrical
Issued 8 January 1991 Resolved
REPLACE MISSING COVER ON LIGHT IN HEAD.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Engineering
Issued 8 January 1991 Resolved
INSTALL LAGGING ON MDE EXHAUSTS FROM EXHAUST MANIFOLD.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Engineering
Issued 8 January 1991 Resolved
MOUNT SPANNER WRENCH IN VICINITY OF REMOTE FUEL OIL SHUTOFFS.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Documentation
Issued 8 January 1991 Resolved
LOCATE AND POST STABILITY LETTER.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Engineering
Issued 8 January 1991 Resolved
REPLACE FLAME SCREEN PORT SIDE FUEL TANK VENT WITH APPROPRIATE 30X30 MESH.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Accommodation/Occupational Safety
Issued 8 January 1991 Resolved
REPLACE ALL DAMAGED OR CORRODED RAILING AND RAIL FITTINGS.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Construction/Loadline
Issued 12 January 1990 Resolved
2 REPLACE HANDLES ON SEA VALVES FOR STBD MAIN ENGINE COOLING SUCTION AND BILGE/FIRE PUMP SEA SUCTION. (JUST FORWARD OF PORT MAIN ENGINE)
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990
Engineering
Issued 12 January 1990 Resolved
1 REPAIR/REPLACE BOTH EXHAUST PIPES ON PORT MAIN ENGINE. BOTH ARE WASTED AND HOLED. REPAIR PRIOR TO GOING BACK IN WATER.
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990
Navigation
Issued 14 December 1989 Resolved
PROVIDE MAGNETIC COMPASS DEVIATION TABLE
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Accommodation/Occupational Safety
Issued 14 December 1989 Resolved
LABEL MSD OVERBOARD DISCHARGE "DO NOT OPEN WITHIN THREE MILES OF US COAST" AND PROVIDE LOCKING DEVICE
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Engineering
Issued 14 December 1989 Resolved
RE-INSTALL GUARDS ON MAIN ENGINE BELTS
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Engineering
Issued 14 December 1989 Resolved
ENCLOSE EMERGENCY FUEL SHUTOFF HANDLES SO AS TO BE OPERABLE FROM OUTSIDE THE FUEL TANK SPACE
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Construction/Loadline
Issued 14 December 1989 Resolved
REPAIR LAZARETTE DOG ACUATION GEAR AND PROVIDE NEW GASKET
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Engineering
Issued 14 December 1989 Resolved
PROVIDE WRENCH ACCESSIBLE TO PASSENGERS FOR EMERGENCY FUEL SHUTOFF COVERS
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Navigation
Issued 14 December 1989 Resolved
DRILL AND COTTER PIN STEERING GEAR LINKAGES.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Engineering
Issued 14 December 1989 Resolved
REPAIR LEAKING COOLING WATER LIND AT FLEX COUPLING AIN FRONT OF STARBOARD ENGINE.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Lifesaving
Issued 9 January 1989 Resolved
RENEW LIFELINE, PENDANTS AND INNER LINE OF LIFEFLOATS.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Engineering
Issued 9 January 1989 Resolved
PROVIDE PERSONNEL GUARDS FOR MAIN ENGINE FAN BELTS.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Lifesaving
Issued 9 January 1989 Resolved
PROVIDE SPACERS BETWEEN STACKED LIFEFLOATS.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Navigation
Issued 9 January 1989 Resolved
EPIRB: RENEW BATTERY; DEMONSTRATE OPERATION; PROVIDE MOUNTING IN A FLOAT- FREE LOCATION. VESSEL RESTRICTED TO NO MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Accommodation/Occupational Safety
Issued 9 January 1989 Resolved
CLEAN OIL FROM MIDSHIP COMPARTMENT BILGES.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Engineering
Issued 9 January 1989 Resolved
SECURE PORT FLAME SCREEN.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Fire Fighting
Issued 9 January 1989 Resolved
ATTACH INTAKE HOSE FOR HAND BILGE/FIRE PUMP.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Engineering
Issued 9 January 1989 Resolved
REPAIR LEAK IN PORT ENGINE EXHAUST COOLING PIPING.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Accommodation/Occupational Safety
Issued 18 December 1985 Resolved
PROVIDE LOCKING MECHANISM FOR MSD DISCHARGE.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Engineering
Issued 18 December 1985 Resolved
PROVIDE FOR INSPECTION OF TAILSHAFTS PRIOR TO REINSTALLATION.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Accommodation/Occupational Safety
Issued 18 December 1985 Resolved
PROVIDE LABELS FOR EMERGENCY EXIT.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Electrical
Issued 18 December 1985 Resolved
REMOVE TWIST-ON WIRE CONNECTORS AND INSTALL PROPER WIRE CONNECTIONS FOR PUMP WIRING AND WATER HEATER IN MID BODY.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Accommodation/Occupational Safety
Issued 18 December 1985 Resolved
PROVIDE DOUBLE CLAMP FOR MSD DISCHARGE.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985