HOS THUNDERFOOT

Built
1999
Last inspected
12 June 2024
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 June 2024
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9211937
491232
Flag
MEXICO
Maury page id
psix-491232

Documentation record

Tonnage as PSIX records it1318 - Convention (Subpart B), Gross Ton
395 - Convention (Subpart B), Net Ton
1677 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 7 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

12 June 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7933518
22 July 2021 PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7263710
12 September 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6804085
6 December 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6588961
30 January 2017 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6079590
25 January 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6071916
8 January 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5789462

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 July 2021 Resolved
Fixed fire detection shall be capable of immediate operation at all times. The fixed fire alarm detection panel was not operable.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 3 August 2021
Resolution: Vessel provided photos of operational fire panel on the bridge
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 July 2021 No resolution recorded
Exposed hatches shall be provided with efficient watertight cover. Both, the starboard and port engine room escape hatchways had gaskets that were coming off of the hatchway, rendering the hatchways not watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 July 2021 Resolved
Ships shall be maintained in compliance with the structural requirements of a classification society. The aft steering compartment door was misaligned and unable to close properly.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2021
Resolution: Vessel provided photos of aft steering door closing properely
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 July 2021 Resolved
The means for securing the weathertight doors shall consist of gaskets and clamping devices that can be operated from both sides. The gasket on the emergency generator door was worn and the bottom left clamping device was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2021
Resolution: Vessel provided photos of new gasket material installed on emergency generator door.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 12 September 2019 Resolved
Oil filtering equipment shall be of a design approved by the Administration. In Considering the design, the Administration shall have regard to the specifications recommended by the Organization. Ships oil content meter is not the type specified by the IOPP supplement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 1 October 2019
Resolution: MSU Houma received updated IOPP supplement reflecting accurate content meter description.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 30 January 2017 Resolved
After any survey of the has been completed, no change shall be made to the machinery. DP failure caused vessel to be involved in collision.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 February 2017
Resolved 3 February 2017
Resolution: DP software issue rectified to satisfaction of RO. See ABS report.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 25 January 2017 Resolved
0735- Personal equipment Firefighting -The fire fighting out fit shall comply with the fire fighting systems Code. PSCO observed that one of the two required fire fighting suits SCBA is missing. 74 SOLAS am 04 II-2.10.1.1 - 60a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2017
Resolved 25 January 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 25 January 2017 Resolved
1030-Steering Gear Alarm- Any main and auxiliary steering gear control system operable from the bridge in the event of a failure of electrical power supply to the control system have an audible and visual alarms shall be given on the navigation bridge. PSCO observed that the Steering gear system alarm panel did not indicate that alarms had been activated. 74SOLAS 04 II-1/29.8.4. 16a
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
Construction/Loadline › Structures › Door
Issued 25 January 2017 Resolved
1270-Doors- After survey of the ship has been completed, no changes shall be made in the structure, equipment, arrangements, materials or scantlings covered by the survey without the sanctions of the administration. PSCO observed starboard side water tight self-closing door located between the engine room and mud room was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 25 January 2017 Resolved
0615-Rescue Boat- Before the ship leaves port and at all times during voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that the starboard side sponson on the rescue boat was deflated and was overdue for the annual inspection. Certificate expired 21 DEC 2016. 74 SOLAS III.20.2. 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 3 February 2017
Resolution: 03FEB2017: Received class report rectifying deficiency. MSU Houma Act#6079590