Records from 2016 to 2026. Most recent: inspection, 20 August 2026.
Inspection history · 26
20 August 2026
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8467492
23 October 2025
COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8245798
5 September 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8227615
7 March 2025
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8091596
28 January 2025
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8069124
6 November 2024
Simplified Stability Test · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8031327
9 September 2024
Plan Review "T" Boat · Examination of Repairs · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8000187
8 August 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7976848
4 January 2024
DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7845033
28 September 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7800769
9 March 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7648492
23 January 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7628112
22 June 2022
Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 7484861
28 January 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7378445
29 September 2021
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7322381
9 November 2020
COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7077657
25 August 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7042574
4 June 2020
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6967734
24 January 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6895745
27 August 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6796478
8 February 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6606305
12 February 2018
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6352635
20 September 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6269364
13 March 2017
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6104357
8 February 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6081871
24 February 2016
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5820806
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 August 2026
No resolution recorded
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date. Vessel didn't have an up to date chart, U.S Coast pilot, and Coast Guard light list.
46 CFR 184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2026
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 20 August 2026
No resolution recorded
A vessel must comply with the applicable design, equipment, personnel, procedures, and record requirements of 33 CFR parts 151. Vessel didn't have a garbage management plan.
46 CFR 184.702
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 August 2026
No resolution recorded
The Rules concerning shapes shall be complied with by day. Vessel didn't have any day shapes.
COLREG Rule 20
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 August 2026
No resolution recorded
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Vessel has expired chemical testing swabs onboard.
46 CFR 185.212
Condition: Invalid
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2025
Resolved
A suitable marine type strainer shall be fitted in the fuel supply line, valves shall be provided with caps or plugs to prevent fuel leakage. Add caps to the port and starboard engines and generator fuel strainers, also replace plastic fuel strainers with metal/glass.
46CFR182.20-40(5)(6)(7)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2025
Resolved
All vessels shall be provided with an approved adult life preserver for each person carried, in addition at least 10% child life preservers. 3 adult life preservers and 1 child life preserver are unsat. Vessel restricted to 66 total persons on board and 6 children until new life preservers are on board.
46CFR180.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 October 2025
Resolved
EPIRB must be stowed in a manner so that it will float free. Move EPIRB to a location that is not under any overhangs or obstructions.
46CFR180.40-1(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2025
Resolved
Fire hoses shall be UL-19, Federal Spec. ZZ-H-451E or garden type of good commercial grade. Replace port and starboard fire hoses.
46CFR181.15-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 October 2025
Resolved
All unsafe and hazardouse situations shall be corrected. Move cleaning supplies from wheelhouse fuse box cabinet.
46CFR176.25-50(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 23 October 2025
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure each marine sanitation device. Add means to secure each sanitation device.
33CFR159.7
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2025
Resolved
Each fire hydrant must have a valve installed to allow the firehose to be removed while the fire main is under pressure. Install valves on port and starboard fire hydrants.
46CFR181.310(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 October 2025
Resolved
Provisions shall be made to prevent the admission of air into the space protected. Fill gaps in aft engine room access hatch.
46CFR181.20-35(a)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 October 2025
Resolved
Each hatch exposed to the weather must be watertight, except a hatch that extends 12 inches above the weather deck may be weathertight. Lazarette trunk is not 12 inches above the weather deck.
46CFR171.124(a)91)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 October 2025
Resolved
A vessel 12 meters or more but less than 50 meters in length shall have a white, red, green or yellow all-around light, visible from a minimum of 2 miles. All around light is obstructed on port and starboard side. Move all around light to an unobstructed view point.
33CFR83.22(b)(v)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 5 November 2025
Resolution: Corrected to the satisfaction of the attending MIs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 January 2025
Resolved
Conduct operational test of bilge pump. Bilge test unsatisfactory. Limited to 49 pax.
Action required: 705 - Other - as specified
Due 4 February 2025
Resolved 7 March 2025
Resolution: Bilge test sat.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 28 January 2025
Resolved
Verify interconnected smoke detection system. Smoke detection system not provided. Vessel limited to 20nm from harbor of safe refuge.
Action required: 705 - Other - as specified
Due 4 February 2025
Resolved 29 January 2025
Resolution: Installed interconnected smoke detectors.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 January 2025
Resolved
Inspect ventilation dampers. Damper condition and arrangements unsatisfactory.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 29 January 2025
Resolution: Installed new fire dampers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 January 2025
Resolved
Fire hose must be corrosion resistant material. Nozzles were not present.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 5 February 2025
Resolution: Corrosion resistant nozzles installed on fire hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 January 2025
Resolved
Child size life jacket must be separate from adult sized life jacket. Child size life jackets were not separate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 29 January 2025
Resolution: Separated child and adult life jackets.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 January 2025
Resolved
Mark escape hatches. Forward escape hatch not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 24 February 2025
Resolution: Provided pictures of signs posted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 January 2025
Resolved
Vessel must carry first aid kit. First aid kit had expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 5 February 2025
Resolution: Satisfactory first aid kit provided.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 January 2025
Resolved
Vessel must comply with requirements of the FCC. GPS not programmed into DSC radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 5 February 2025
Resolution: VHF radio DSC function programmed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 November 2020
Resolved
Each vessel operating on oceans routes in warm water must be provided with IBAs at 67% or life floats at 100%. Install replacement IBAs. Vessel is restricted from carrying passengers until installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2020
Resolution: Evidence provided that IBAs satisfactorily serviced and installed.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 9 November 2020
Resolved
A vessel must comply with any radio as set forth by 47 CFR 80. Install correct MF/HF radio. Vessel is restricted to not more than 20 miles until replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 13 November 2020
Resolution: Evidence provided of proper radio installation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020
Resolved
Vessel must have mounted emergency instructions for heavy weather. Update emergency instructions and mount.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 12 November 2020
Resolution: Heavy weather emergency instructions provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 November 2020
Resolved
The number of each lifejackets must be marked on each storage container. Mark each container with correct number.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 17 November 2020
Resolution: Containers marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2020
Resolved
Non-metallic hoses must be ran to be protected from mechanical damage. Hydraulic lines for anchor windless needs to be properly mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 2 December 2020
Resolution: Flexible hoses mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020
Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR 40. Have all marine employees enrolled in a testing program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 2 December 2020
Resolution: Proper documentation provided.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 November 2020
Resolved
A penetration in a watertight bulkhead must be made watertight. Numerous bulkhead penetrations in the engine room, forward compartment and forepeak have either deteriorated or missing seals. Repair/replace penetration seals by an approved method.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2020
Resolved 16 December 2020
Resolution: Penetrations sealed with approved material.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 November 2020
Resolved
Each ladder used for escape must be mounted. Engine room ladder must be mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 November 2020
Resolution: Ladder mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 January 2020
Resolved
Suitable covers shall be installed in way of exposed and hazardous places such as gears, machinery, etc. There is no guard covering the belt on the generator. Install a suitable cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 3 February 2020
Resolution: A suitable machinery cover was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 January 2020
Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Identified a cracked weld on the railing on the STBD quarter. Replace that section of railing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 3 February 2020
Resolution: Railing section was cropped and renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 February 2019
Resolved
The battery for each ring life buoy waterlight must be in compliance with sub-chapter Q. The battery was expired. Replace with a new battery that is an acceptable model.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Battery replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 February 2019
Resolved
The battery for each buoyant apparatus waterlight must be in compliance with sub-chapter Q. The battery was the incorrect model and corroded. Replace with a new battery that is an acceptable model.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Battery replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 February 2019
Resolved
All vessels must have navigation lights that are in compliance with Navigation Rules. Starboard side lens was cracked. Replace lens.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Lens replaced.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 8 February 2019
Resolved
Vessels with a Type-III MSD must have an acceptable method of securing the device. Vessel had no means of securing MSD IAW 33 CFR. Provide an acceptable means of securing the MSD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Lock installed on MSD overboard valve.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 February 2019
Resolved
A vessel must comply with requirements for a station license and installation certificates issued by the FCC, as per 47 CFR part 80. The vessel had different call signs on Station Authorization & Safety Certificates. Determine correct call sign, update certificates accordingly, and ensure correct MMSI is programmed into VHF radio with Digital Selective Calling capability.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Call sign, certificates, and MMSI all sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 February 2019
Resolved
Placards containing instructions for the donning and use of life jackets must be posted in a conspicuous place. Instructions currently being used are not model specific. Replace existing instructions to match actual model of life jackets onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Instructions replaced.
Lifesaving › Hand Flares › Expired
Issued 12 February 2018
Resolved
08 red flares and 05 orange smokes onboard. All smokes expired. Provide 04 additional red flares or orange smokes.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2018
Resolved 12 February 2018
Resolution: Corrected before inspectors departed vessel.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 February 2018
Resolved
03 adult lifejackets found to not be serviceable. 01 new jacket provided on the spot. Passenger count reduced from 67 to 65 until 02 additional jackets can be provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 13 February 2018
Resolution: Master provided invoice of 3 lifejackets replaced on board 02/13/2018.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 12 February 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 13 February 2018
Resolution: Owner provided picture of Marine Radio Operator Permit.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 February 2018
Resolved
Seal multiple wire runs/penetrations in engine room fwd and aft bulkheads.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 13 February 2018
Resolution: Owner provided photo of Flamestopper 5000 receipt.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 12 February 2018
Resolved
Paper chart is not used and has not been updated since original issue in 2007. Provide updated paper chart.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 13 February 2018
Resolution: Owner provided photo of current chart.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 February 2017
Resolved
Replace 03 adult life jackets and 01 child lifejackets. Reduced passenger count to 64.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 10 February 2017
Resolution: Proof of purchase submitted via e-mail. Owner stated lifejackets marked and lights installed.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 8 February 2017
Resolved
Rewrite and post updated emergency procedures to reflect more spectific details.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 10 February 2017
Resolution: Proof of update received via e-mail.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 8 February 2017
Resolved
Replace forward window in card room. 46 CFR 177.1010
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 10 February 2017
Resolution: Proof of new window installation received.
Engineering › Fuel Oil Service System › Hose
Issued 8 February 2017
Resolved
Properly install fuel lines at watertight bulkhead in engine room to tank room. 46 CFR 182.20-40
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 13 March 2017
Resolution: Owner properly installed fuel lines.