MAURY USCG vessel records Sign in
← All vessels

SEA SPIRIT

SEA SPIRIT is a 1977 passenger vessel (inspected). The Coast Guard has recorded 76 inspections since 1985, most recently in August 2026, along with 173 deficiencies — 4 with no resolution recorded —, 1 operational control and 1 casualty investigation in 2020.

Records from 1985 to 2026. Most recent: inspection, 20 August 2026.

Built
1977
Last inspected
20 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG6013
Flag
UNITED STATES
367552590
Maury page id
psix-49127

Inspections, by type

…with no type recorded5
…past their stated due date3
Years with a record 36 calendar years (1985–2026)
The 76 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)57.3 ft × 18.4 ft × 5.3 ft
Registered tonnagegross 49 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT L SHERBERT · PONCE INLET, FL, UNITED STATES · built 1977
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPONCE INLET, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 13 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG6013MMSI 367552590 · active · compulsorily equipped · granted 16 August 2022, expires 6 November 2032
WDA3256MMSI 366796340 · expired · compulsorily equipped · granted 10 November 2010, cancelled 13 February 2021
WTS9702MMSI not assigned · expired · compulsorily equipped · granted 12 November 1996, cancelled 14 April 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 76

20 August 2026 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8467492
23 October 2025 COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8245798
5 September 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8227615
7 March 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8091596
28 January 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8069124
6 November 2024 Simplified Stability Test · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8031327
9 September 2024 Plan Review "T" Boat · Examination of Repairs · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8000187
8 August 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7976848
4 January 2024 DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7845033
28 September 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7800769
9 March 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7648492
23 January 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7628112
22 June 2022 Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 7484861
28 January 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7378445
29 September 2021 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7322381
9 November 2020 COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7077657
25 August 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7042574
4 June 2020 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6967734
24 January 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6895745
27 August 2019 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6796478
8 February 2019 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6606305
12 February 2018 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6352635
20 September 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6269364
13 March 2017 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6104357
8 February 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6081871
24 February 2016 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5820806
16 November 2015 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5762333
6 October 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5718565
18 November 2010 COI Inspection · Deficiency Check · Internal Structural Exam · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3888931
24 December 2008 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3384455
27 November 2008 Drydock Extension · Internal Structural Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3369752
14 January 2008 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3127853
10 December 2007 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3113418
13 November 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3096013
17 November 2005 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2536672
22 November 2004 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2245704
26 January 2004 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1992770
19 November 2003 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1950187
11 October 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1688757
14 November 2001 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1450701
9 August 2001 Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1075095
8 January 2001 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1469008
6 March 2000 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1378929
14 December 1999 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1421773
4 January 1999 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1413459
23 February 1998 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 779111
30 January 1998 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1117745
14 January 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1099379
17 December 1996 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1095886
29 January 1996 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 881830
20 December 1995 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 880210
6 January 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1167643
27 December 1994 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1161629
9 February 1994 Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1162179
25 March 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 839447
19 February 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 835170
5 January 1993 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1140038
27 October 1992 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1267726
29 January 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1255214
7 January 1992 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1261272
18 April 1991 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 928178
14 January 1991 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 918931
7 February 1990 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1215782
6 February 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 901103
22 January 1990 Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 930642
7 March 1989 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1199443
7 September 1988 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1348156
26 July 1988 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1341722
22 March 1988 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1275269
21 December 1987 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1313086
7 October 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1320732
25 March 1987 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1327181
27 January 1987 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1318457
19 March 1986 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 992773
15 August 1985 Credit Drydock
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1294908
26 March 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1291046

Deficiency record · 173

10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 August 2026 No resolution recorded
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date. Vessel didn't have an up to date chart, U.S Coast pilot, and Coast Guard light list. 46 CFR 184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2026 — due date passed with no resolution recorded
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 20 August 2026 No resolution recorded
A vessel must comply with the applicable design, equipment, personnel, procedures, and record requirements of 33 CFR parts 151. Vessel didn't have a garbage management plan. 46 CFR 184.702
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2026 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 August 2026 No resolution recorded
The Rules concerning shapes shall be complied with by day. Vessel didn't have any day shapes. COLREG Rule 20
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2026 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 August 2026 No resolution recorded
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Vessel has expired chemical testing swabs onboard. 46 CFR 185.212
Condition: Invalid
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2025 Resolved
A suitable marine type strainer shall be fitted in the fuel supply line, valves shall be provided with caps or plugs to prevent fuel leakage. Add caps to the port and starboard engines and generator fuel strainers, also replace plastic fuel strainers with metal/glass. 46CFR182.20-40(5)(6)(7)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2025 Resolved
All vessels shall be provided with an approved adult life preserver for each person carried, in addition at least 10% child life preservers. 3 adult life preservers and 1 child life preserver are unsat. Vessel restricted to 66 total persons on board and 6 children until new life preservers are on board. 46CFR180.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 October 2025 Resolved
EPIRB must be stowed in a manner so that it will float free. Move EPIRB to a location that is not under any overhangs or obstructions. 46CFR180.40-1(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2025 Resolved
Fire hoses shall be UL-19, Federal Spec. ZZ-H-451E or garden type of good commercial grade. Replace port and starboard fire hoses. 46CFR181.15-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 October 2025 Resolved
All unsafe and hazardouse situations shall be corrected. Move cleaning supplies from wheelhouse fuse box cabinet. 46CFR176.25-50(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 23 October 2025 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure each marine sanitation device. Add means to secure each sanitation device. 33CFR159.7
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2025 Resolved
Each fire hydrant must have a valve installed to allow the firehose to be removed while the fire main is under pressure. Install valves on port and starboard fire hydrants. 46CFR181.310(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 October 2025 Resolved
Provisions shall be made to prevent the admission of air into the space protected. Fill gaps in aft engine room access hatch. 46CFR181.20-35(a)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 October 2025 Resolved
Each hatch exposed to the weather must be watertight, except a hatch that extends 12 inches above the weather deck may be weathertight. Lazarette trunk is not 12 inches above the weather deck. 46CFR171.124(a)91)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 30 October 2025
Resolution: Corrected to the satisfaction of the attending MIs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 October 2025 Resolved
A vessel 12 meters or more but less than 50 meters in length shall have a white, red, green or yellow all-around light, visible from a minimum of 2 miles. All around light is obstructed on port and starboard side. Move all around light to an unobstructed view point. 33CFR83.22(b)(v)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 5 November 2025
Resolution: Corrected to the satisfaction of the attending MIs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 January 2025 Resolved
Conduct operational test of bilge pump. Bilge test unsatisfactory. Limited to 49 pax.
Action required: 705 - Other - as specified
Due 4 February 2025
Resolved 7 March 2025
Resolution: Bilge test sat.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 28 January 2025 Resolved
Verify interconnected smoke detection system. Smoke detection system not provided. Vessel limited to 20nm from harbor of safe refuge.
Action required: 705 - Other - as specified
Due 4 February 2025
Resolved 29 January 2025
Resolution: Installed interconnected smoke detectors.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 January 2025 Resolved
Inspect ventilation dampers. Damper condition and arrangements unsatisfactory.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 29 January 2025
Resolution: Installed new fire dampers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 January 2025 Resolved
Fire hose must be corrosion resistant material. Nozzles were not present.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 5 February 2025
Resolution: Corrosion resistant nozzles installed on fire hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 January 2025 Resolved
Child size life jacket must be separate from adult sized life jacket. Child size life jackets were not separate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 29 January 2025
Resolution: Separated child and adult life jackets.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 January 2025 Resolved
Mark escape hatches. Forward escape hatch not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 24 February 2025
Resolution: Provided pictures of signs posted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 January 2025 Resolved
Vessel must carry first aid kit. First aid kit had expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 5 February 2025
Resolution: Satisfactory first aid kit provided.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 January 2025 Resolved
Vessel must comply with requirements of the FCC. GPS not programmed into DSC radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 5 February 2025
Resolution: VHF radio DSC function programmed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 November 2020 Resolved
Each vessel operating on oceans routes in warm water must be provided with IBAs at 67% or life floats at 100%. Install replacement IBAs. Vessel is restricted from carrying passengers until installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2020
Resolution: Evidence provided that IBAs satisfactorily serviced and installed.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 9 November 2020 Resolved
A vessel must comply with any radio as set forth by 47 CFR 80. Install correct MF/HF radio. Vessel is restricted to not more than 20 miles until replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 13 November 2020
Resolution: Evidence provided of proper radio installation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
Vessel must have mounted emergency instructions for heavy weather. Update emergency instructions and mount.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 12 November 2020
Resolution: Heavy weather emergency instructions provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 November 2020 Resolved
The number of each lifejackets must be marked on each storage container. Mark each container with correct number.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 17 November 2020
Resolution: Containers marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2020 Resolved
Non-metallic hoses must be ran to be protected from mechanical damage. Hydraulic lines for anchor windless needs to be properly mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 2 December 2020
Resolution: Flexible hoses mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2020 Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR 40. Have all marine employees enrolled in a testing program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 2 December 2020
Resolution: Proper documentation provided.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 November 2020 Resolved
A penetration in a watertight bulkhead must be made watertight. Numerous bulkhead penetrations in the engine room, forward compartment and forepeak have either deteriorated or missing seals. Repair/replace penetration seals by an approved method.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2020
Resolved 16 December 2020
Resolution: Penetrations sealed with approved material.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 November 2020 Resolved
Each ladder used for escape must be mounted. Engine room ladder must be mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 November 2020
Resolution: Ladder mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 January 2020 Resolved
Suitable covers shall be installed in way of exposed and hazardous places such as gears, machinery, etc. There is no guard covering the belt on the generator. Install a suitable cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 3 February 2020
Resolution: A suitable machinery cover was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 January 2020 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Identified a cracked weld on the railing on the STBD quarter. Replace that section of railing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 3 February 2020
Resolution: Railing section was cropped and renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 February 2019 Resolved
The battery for each ring life buoy waterlight must be in compliance with sub-chapter Q. The battery was expired. Replace with a new battery that is an acceptable model.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Battery replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 February 2019 Resolved
The battery for each buoyant apparatus waterlight must be in compliance with sub-chapter Q. The battery was the incorrect model and corroded. Replace with a new battery that is an acceptable model.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Battery replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 February 2019 Resolved
All vessels must have navigation lights that are in compliance with Navigation Rules. Starboard side lens was cracked. Replace lens.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Lens replaced.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 8 February 2019 Resolved
Vessels with a Type-III MSD must have an acceptable method of securing the device. Vessel had no means of securing MSD IAW 33 CFR. Provide an acceptable means of securing the MSD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Lock installed on MSD overboard valve.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 February 2019 Resolved
A vessel must comply with requirements for a station license and installation certificates issued by the FCC, as per 47 CFR part 80. The vessel had different call signs on Station Authorization & Safety Certificates. Determine correct call sign, update certificates accordingly, and ensure correct MMSI is programmed into VHF radio with Digital Selective Calling capability.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Call sign, certificates, and MMSI all sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 February 2019 Resolved
Placards containing instructions for the donning and use of life jackets must be posted in a conspicuous place. Instructions currently being used are not model specific. Replace existing instructions to match actual model of life jackets onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Instructions replaced.
Lifesaving › Hand Flares › Expired
Issued 12 February 2018 Resolved
08 red flares and 05 orange smokes onboard. All smokes expired. Provide 04 additional red flares or orange smokes.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2018
Resolved 12 February 2018
Resolution: Corrected before inspectors departed vessel.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 February 2018 Resolved
03 adult lifejackets found to not be serviceable. 01 new jacket provided on the spot. Passenger count reduced from 67 to 65 until 02 additional jackets can be provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 13 February 2018
Resolution: Master provided invoice of 3 lifejackets replaced on board 02/13/2018.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 12 February 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 13 February 2018
Resolution: Owner provided picture of Marine Radio Operator Permit.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 February 2018 Resolved
Seal multiple wire runs/penetrations in engine room fwd and aft bulkheads.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 13 February 2018
Resolution: Owner provided photo of Flamestopper 5000 receipt.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 12 February 2018 Resolved
Paper chart is not used and has not been updated since original issue in 2007. Provide updated paper chart.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 13 February 2018
Resolution: Owner provided photo of current chart.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 February 2017 Resolved
Replace 03 adult life jackets and 01 child lifejackets. Reduced passenger count to 64.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 10 February 2017
Resolution: Proof of purchase submitted via e-mail. Owner stated lifejackets marked and lights installed.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 8 February 2017 Resolved
Rewrite and post updated emergency procedures to reflect more spectific details.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 10 February 2017
Resolution: Proof of update received via e-mail.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 8 February 2017 Resolved
Replace forward window in card room. 46 CFR 177.1010
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 10 February 2017
Resolution: Proof of new window installation received.
Engineering › Fuel Oil Service System › Hose
Issued 8 February 2017 Resolved
Properly install fuel lines at watertight bulkhead in engine room to tank room. 46 CFR 182.20-40
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 13 March 2017
Resolution: Owner properly installed fuel lines.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 November 2015 Resolved
Prove proper operation of pre-enginered fire supression system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2015
Resolved 19 November 2015
Resolution: Attending MI witnessed proper operation.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 November 2015 Resolved
Provide audible and visual alram at the operating station to indicat discharge of pre-enginered fire supression systems.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 19 November 2015
Resolution: Attending MI witnessed proper operation.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 16 November 2015 Resolved
Replace broken window port side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 19 November 2015
Resolution: Attending MI witnessed proper repairs.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 16 November 2015 Resolved
Replace reflective tape and rename life jackets as indicated on 17 life jackets. Limit passenger count to 52 persons.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2015
Resolved 19 November 2015
Resolution: Attending MI witnessed proper repairs.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 November 2015 Resolved
Replace 05 expired batteries in floating life lights. Prior to operating at night.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2015
Resolved 19 November 2015
Resolution: Attending MI witnessed proper replacement.
Lifesaving › Lifefloat › Float-free Link
Issued 16 November 2015 Resolved
Ensure weak links on life floats are arranged in a float-free configuration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 19 November 2015
Resolution: Attending MI witnessed proper corrections.
Construction/Loadline › Hull › Hull Plating
Issued 18 November 2010 Resolved
PORT SIDE APPROXIMATELY 3 FEET FORWARD OF STERN, REPAIR GEL COATING WHERE WOOD IS EXPOSED.
Due 18 December 2010
Resolved 2 December 2010
Resolution: Gel coating repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 18 November 2010 Resolved
STARBOARD SIDE E/R TRANSVERSE DECK FRAME #6 FORWARD OF THE AFT BULKHEAD NEEDS TO BE REPLACED OR SISTERED AS MARKED. NEEDS TO BE REPAIRED DURNING NEXT DRY DOCK.
Due 30 November 2011
Resolved 13 June 2011
Resolution: Deck frame was found to be sistered to the satisfaction of the inspector.
Engineering › Bilge Water Management System › Hose
Issued 18 November 2010 Resolved
THE SUCTION HOSE FROM THE BILGE MANIFOLD TO THE FIRE PUMPS NEEDS TO REPLACED WITH AN APPROVED HOSE
Due 25 November 2010
Resolved 25 November 2010
Resolution: Replaced with approved hose.
Lifesaving › Lifebuoys › Serviceable
Issued 18 November 2010 Resolved
PORT SIDE LIFE RING BUOY NEEDS TO BE REPAIRED.
Due 25 November 2010
Resolved 25 November 2010
Resolution: Ring bouy repaired.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 November 2010 Resolved
LIFE FLOAT LIGHT FOR PORT SIDE FWD LIFE FLOAT NEEDS TO RENEW/REPLACE BATTERY WITH APPROVED TYPE AND WITH POST SCREW TYPE TERMINALS.
Due 18 December 2010
Resolved 2 December 2010
Resolution: Life float light renewed with battery.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 November 2010 Resolved
REPLACE 8 ADULT LIFE JACKETS WITH APPROVED TYPE.
Due 18 December 2010
Resolved 25 November 2010
Resolution: Life jackets replaced.
Engineering › Bilge Water Management System › Not Installed
Issued 18 November 2010 Resolved
INSTALL OR PROVE PRPER OPERATION OF VISUAL BILGE HIGH LEVEL INDICATORS AT OPERATING STATION. VISUAL INDICATORS FOR EACH SPACE BELOW THE WATER LINE.
Due 25 November 2010
Resolved 25 November 2010
Resolution: Proved proper operation of high level alarms.
Construction/Loadline › Hull › Transverse Frame
Issued 18 November 2010 Resolved
PROPERLY REPLACE OR SISTER #6 (FROM PORT) BULKHEAD FRAME ON STERN
Due 30 November 2011
Resolved 13 June 2011
Resolution: Bulkhead frame was found to be sistered to the satisfaction of the inspector.
Engineering › Lubricating Oil Service System › Hose
Issued 18 November 2010 Resolved
RENEW L/O LINE ON PORT ENGINE AS INDICATED.
Due 18 December 2010
Resolved 2 December 2010
Resolution: L/o line renewed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 November 2010 Resolved
CAP OFF OPEN EXHAUST LINE PENETRATING AFT E/R BULKHEAD.
Due 18 December 2010
Resolved 2 December 2010
Resolution: Open exhaust line capped.
Engineering › Bilge Water Management System › Not Operational
Issued 18 November 2010 Resolved
RENEW WIRE ON AFT E/R ELECTRIC BILGE PUMP
Due 25 November 2010
Resolved 25 November 2010
Resolution: Wire renewed.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 18 November 2010 Resolved
REATTACH BONDING CABLE ON THE PORT SHAFT STRUT IN THE STEERING COMPARTMENT
Due 25 November 2010
Resolved 25 November 2010
Resolution: Bonding cable reattached.
Construction/Loadline › Hull › Hull Plating
Issued 18 November 2010 Resolved
Properly seal port side wet joint in E/R as indictated
Due 18 December 2010
Resolved 2 December 2010
Resolution: Port side joint sealed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 December 2008 Resolved
Amend emergency instructions to reflect actual procedures
Action required: 705 - Other - as specified
Due 3 January 2009
Resolved 22 December 2008
Resolution: Instruction are amended.
Construction/Loadline › Structures › Deck Plating
Issued 3 December 2008 Resolved
Repair wasted deck area Port and STBD. IWO the fwd peck space as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2009
Resolved 22 December 2008
Resolution: The deck was crop and renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 December 2008 Resolved
Properly secure main deck railing as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2009
Resolved 22 December 2008
Resolution: Railing is secured
Lifesaving › Lifebuoys › Serviceable
Issued 3 December 2008 Resolved
Renew the ring buoy
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2008
Resolution: New ring buoy
Fire Fighting › Means of Escape › Stairways
Issued 3 December 2008 Resolved
Secure the ladder in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2009
Resolved 22 December 2008
Resolution: Ladder is secured.
Construction/Loadline › Hull › Hull Plating
Issued 3 December 2008 Resolved
Make repairs to the stern planking as needed. Next dry dock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2009
Resolved 24 November 2009
Resolution: Repaired all fractured vertical and transverse frames during scheduled dry-dock.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 November 2008 Resolved
Secure the lagging on the exhaust in the engine room and steering room.
Action required: 705 - Other - as specified
Due 3 January 2009
Resolved 22 December 2008
Resolution: Lagging is secured.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 10 December 2007 Resolved
Vessel to acquire updated Nav Pubs. Nav Pubs onboard are outdated and not being kept up with by NTMs.
Action required: 705 - Other - as specified
Due 10 January 2008
Resolved 14 January 2008
Resolution: New pubs are onboard.
Lifesaving › Lifefloat › Painter
Issued 10 December 2007 Resolved
Renew painter line of port aft lifefloat - line is dry rotted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2007
Resolution: Painter renewed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 December 2007 Resolved
Secure stbd nav light - light bracket is loose.
Action required: 705 - Other - as specified
Due 10 January 2008
Resolved 14 January 2008
Resolution: Bracket is repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 December 2007 Resolved
Replace deck lights thoughout vessel as needed.
Action required: 705 - Other - as specified
Due 10 January 2008
Resolved 14 January 2008
Resolution: Deck lights are working.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 December 2007 Resolved
Remove or secure aft ladder to engine room.
Action required: 705 - Other - as specified
Due 10 January 2008
Resolved 14 January 2008
Resolution: Ladder is secured.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 December 2007 Resolved
Install 60' of buoyant line to life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2007
Resolution: Line attached to life ring.
Engineering › Steering Gear System › Fastener
Issued 10 December 2007 Resolved
Secure steering arm bracket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2007
Resolution: Steering arm bracket secured.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 10 December 2007 Resolved
Make all ventilation colsures to teh engine room airtight - closure device to aft door engine room does not completely seal off, allowing air to enter engine room.
Action required: 705 - Other - as specified
Due 10 January 2008
Resolved 14 January 2008
Resolution: A bottom plate was put on the door to seal to the closure.
Construction/Loadline › Hull › Transverse Frame
Issued 10 December 2007 Resolved
Submit proposal to amke permanent repairs to underdeck supports in fuel tank space.
Action required: 705 - Other - as specified
Due 10 January 2008
Resolved 14 January 2008
Resolution: Proposal has been submitted.
Operations/Management › Drills/Instruction › Fire
Issued 10 December 2007 Resolved
Provide emergency instructions for crew; post as necessary.
Action required: 705 - Other - as specified
Due 10 January 2008
Resolved 14 January 2008
Resolution: E- Instructions are posted.
Engineering › Steering Gear System › Rudder Bearing
Issued 13 November 2007 Resolved
Renew port and stbd rudder bearings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2007
Resolution: Port and stbd rudder bearings renewed.
Construction/Loadline › Hull › Keel
Issued 13 November 2007 Resolved
Properly repair wooden worm show in way of fastners.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2007
Resolved 16 November 2007
Resolution: Worm Shoe repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 13 November 2007 Resolved
Crop and renew wasted wood near port rudder at stern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2007
Resolution: Area cropped and renewed.
Engineering › Bilge Water Management System › Piping
Issued 13 November 2007 Resolved
Properly secure bilge piping in steering compartment port side fwd. Crop and renew wasted bulkhead portside near bilge pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2007
Resolution: Bilge piping secured and bulkhead repaired.
Engineering › Bilge Water Management System › Piping
Issued 13 November 2007 Resolved
Remove pathc from bilge piping portside engine room and properly renew and secure as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2007
Resolution: Patch removed and pipe properly repaired.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 November 2007 Resolved
Secure all bulkhead penetrations throughout the vessel as needed.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 16 November 2007
Resolution: Penetrations secured.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 November 2007 Resolved
Properly secure portside exhaust brackets - engine room.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 16 November 2007
Resolution: Brackets secured.
Engineering › Bilge Water Management System › Not Operational
Issued 13 November 2007 Resolved
Make auto bilge floats operational throughout the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2007
Resolution: All bilge alarms operational.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 13 November 2007 Resolved
Properly secure all interior railing and ladders as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2007
Resolution: Ladders and rails secured.
Construction/Loadline › Structures › Deck Plating
Issued 13 November 2007 Resolved
Crop and renew wasted deck area portside at access point above port MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2007
Resolution: Deck cropped and renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 13 November 2007 Resolved
Make proper repairs to rotten gussets in way of chine bar and frames, as needed throughout the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2007
Resolution: Proper repairs to made.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 13 November 2007 Resolved
Repair fuel oil lead at stbed fuel oil tank cut off valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2007
Resolution: Valve repaired.
Lifesaving › Lifefloat › Float-free Link
Issued 22 November 2005 Resolved
Two of the life floats install on top of pilot house are installed in tandom, no weak link installed on painter attachment. Provide weak link and install according with the manufactures instructions.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 November 2005
Resolved 20 December 2005
Resolution: Link properly installed.
Lifesaving › Lifefloat › Markings
Issued 22 November 2005 Resolved
Retro Reflective tape on all six life floats is worn and lost effictiveness, renew all retro tape on all life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Retro Reflective tape installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 November 2005 Resolved
Life ring float light has excessive line and no quick disconnect clip attaching it to life ring. Install the required line ( ' to 6') with quick disconnect clip at life float.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Line and quick release properly insatlled.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 22 November 2005 Resolved
No emergency procedures posted as per 46 CFR 185.510, provide emergency procedures and display.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Instruction properly posted.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 November 2005 Resolved
Child size life jackets were stowed with adult life jackets. Provide separate stowage and properly lablel for all child life jackets
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Child life jackets properly installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 November 2005 Resolved
Exaust lagging on Port Engine inboard Turbo and Turbo elbow requires replacement, due to excessive wear and tear.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Lagging replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 November 2005 Resolved
Alternator belt assemble on port engine is located next to access ladder that does not have a guard installed, provide a guard and install to the satisfaction of attending marine inspector.
Condition: Improper Installation
Due 22 December 2005
Resolved 20 December 2005
Resolution: Guard installed..
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 November 2005 Resolved
Three 12v DC power distribution panels under starboard side of pilot house console require proper installation of covers, screws missing, open unsafe. Properly install covers with screws.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Panels covers properly secured..
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 November 2005 Resolved
Properly secure exterior passenger bench, port side of of house.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Exterior bench properly secured.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 November 2005 Resolved
Step box on stairs going up to pilot house from cabin is loose, broken. Repair step.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Step properly secured...
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 22 November 2005 Resolved
Two Type III MSD's installed, overboard discharge valves on both are frozen and can not be operated. Repair or replace to provide proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Valved are operational and closed while inport.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 November 2005 Resolved
All passenger benches inside cabin must be properly secured to the deck, to prevent movement while underway. As per 46 CFR 177.820
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Passenger bench properly secured.
Engineering › Bilge Water Management System › Valve
Issued 22 November 2005 Resolved
Electric submersible pumps installed must have a postitive closing valve located on the discharge side at the hull penetration provide valves on all installed electric submersible bilge pump discharge hoses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 January 2006
Resolved 20 November 2006
Resolution: Valves were installed.
Stability › Weathertight Integrity › General
Issued 17 November 2005 Resolved
Two broken windows in pilot house, one on starboard side forward, and one port side. Replace broken windows.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 20 December 2005
Resolution: Windows were replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 November 2004 Resolved
Renew -5- child and 16- adult PFDs with an approved type life jacket. Provide markings on same. Provide an approved PFD light for each PFD.
Due 30 December 2004
Resolved 13 December 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 November 2004 Resolved
Install an approved masthead light. Vessel is limited to daylight operations until this item is corrected. Install an approved anchor light in place of the general purpose light fixture.
Due 30 December 2004
Resolved 13 December 2004
Resolution: Combination light installed.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 22 November 2004 Resolved
Reattach the broken bonding ground wires in the lazarette.
Condition: Improper/Lack of Maintenance
Due 30 December 2004
Resolved 13 December 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 22 November 2004 Resolved
Remove all light fixtures with ceramic bases and install acceptable bases.
Condition: Improper Installation
Due 30 December 2004
Resolved 13 December 2004
Resolution: Recepticals renewed with U/L Listed phelonic base lamp holders.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 24 November 2003 Resolved
PROVIDE CLOSURE DEVICES FOR ALL VENTS TO THE ENGINE ROOM PER 46CFR182.465(h).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2003
Resolved 16 December 2003
Documentation › Certificates/Documents
Issued 24 November 2003 Resolved
CHANGE DOCUMENT TO "SEA SPIRIT" OR RE-LABEL LIFESAVING EQUIPMENT. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 24 December 2003
Resolved 26 January 2004
Stability › Incline Test
Issued 11 October 2002 Resolved
Stability letter missing from vessel
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2002
Resolved 12 October 2002
Resolution: Rcvd Letter from old owner
Lifesaving › Buoyant Apparatus
Issued 11 October 2002 Resolved
Lifejacket waterlights were missing from all jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2002
Resolved 12 October 2002
Resolution: New waterlights procured and placed in service
Lifesaving › Rigid Liferafts › Stability
Issued 11 October 2002 Resolved
Lifefloat need replacing
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2002
Resolved 12 October 2002
Resolution: New lifefloat procured
Navigation › Electronic Positioning
Issued 11 October 2002 Resolved
EPRIB Hydr release outdated
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2002
Resolved 12 October 2002
Resolution: New HYDRO installed
Engineering › Bilge Water Management System › Piping
Issued 11 October 2002 Resolved
Bilge system High water alarms missing inoperative and improper
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2002
Resolved 12 October 2002
Resolution: Bilge system alarms working proper and hooked up
Documentation › Logs/Records › Logbook (official)
Issued 11 October 2002 Resolved
Charts pub's Log book missing from vessel
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2002
Resolved 12 October 2002
Resolution: Pub, charts log book procured
Communications › Alarms/Indicators › General Alarm
Issued 11 October 2002 Resolved
No horn or bell on board vessel
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2002
Resolved 12 October 2002
Resolution: Vessel procured a horn and a bell as per Nav rule
Documentation › Certificates/Documents
Issued 11 October 2002 Resolved
Captain did not have license on board
Due 11 November 2002
Resolved 12 October 2002
Resolution: Sighted orginal license
Electrical › Lighting (service)
Issued 11 October 2002 Resolved
Dead end wires hanging in engine room
Due 11 November 2002
Resolved 12 October 2002
Resolution: Removed wires
Documentation › Markings/Placards
Issued 11 October 2002 Resolved
Lifejackets donning placard missing provide proper placards
Due 11 November 2002
Resolved 12 October 2002
Resolution: New placards sighted
Accommodation/Occupational Safety
Issued 6 March 2000 Resolved
RENEW BROKEN BRIDGE WINDOWS.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Construction/Loadline
Issued 6 March 2000 Resolved
Remove rotten aft deck area to good wood and replace broken and rotten deckbeams. have area inspected prior to replacement . Replace in kind.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Engineering
Issued 6 March 2000 Resolved
REPLACE FUEL PIPING FROM FUEL TANKS (PORT AND STABD) TO ENG COMPARTMENT.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Construction/Loadline
Issued 6 March 2000 Resolved
MAKE BOTH HATCHES ON BOW WEATHER TIGHT AND PROVIDE SECURING DEVICES AND ATTACHED TO FRAME BY SOME MEANS TO PREVENT LOSS.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Engineering
Issued 6 March 2000 Resolved
REMOVE SHAFTS AND MAKE AVALIABLE FOR INSPECTION.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Construction/Loadline
Issued 6 March 2000 Resolved
PROVIDE [name withheld] PROPOSAL OF ROTTEN HULL PLANKS AND REPLACEMENT OF RUB RAIL ON PORT AND STBD SIDES AFT.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Documentation
Issued 14 December 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 14 December 1999 Resolved
REPAIR/RENEW 2 LIFE ADULT JACKETS. VESSEL PASSENGER CAP. REDUCED TO 68 UNTIL JACKETS REPLACED.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 14 December 1999 Resolved
PROVIDE BILGE HIGH LEVEL ALARMS FOR ALL COMPARTMENTS BELOW THE WATER LINE.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 14 December 1999 Resolved
SEAL HOLES IN FWD ENGINE ROOM BULKHEAD FOR HYDRULIC HOSE TO THE FWD COLLISION BULKHEAD.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Fire Fighting
Issued 14 December 1999 Resolved
PROVIDE NEW FIRE HOSE PRIOR TO 14JAN00
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 4 January 1999 Resolved
MAKE VESSELS COLLISION BULKHEAD WATERTIGHT WHERE THE ANCHOR WINDLASS HYDRAULIC LINE PENETRATES THE BULKHEAD.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Navigation
Issued 4 January 1999 Resolved
REPAIR/ REPLACE THE SINGLE SIDE BAND RADIO. VESSELS ROUTE RESTRICTED TO COASTWISE 20 MILES UNTIL THE SSB RADIO IS OPERATIVE.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Documentation
Issued 4 January 1999 Resolved
RENEW AND PROVIDE A VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Accommodation/Occupational Safety
Issued 30 January 1998 Resolved
Properly mark lifejacket lockers with number of adult and child sized jackets.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Electrical
Issued 17 December 1996 Resolved
INSTALL PORTABLE EMER LIGHTS AT CONTROL STATION AND AT MACHINERY SPACE ENTRANCE.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Documentation
Issued 17 December 1996 Resolved
ESTABLISH TRAINING LOGS, POST PFD PLACARDS IAW 46 CFR 185 DTD 11MAR96.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Navigation
Issued 17 December 1996 Resolved
PROVIDE UPDATED COAST PILOT, TIDE/CURRENT TABLES, LIGHT LISTS, CHARTS FOR _x001C_AUTHORIZED ROUTE.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Accommodation/Occupational Safety
Issued 17 December 1996 Resolved
REPAIR 2ND AND 5TH LANDINGS OF STAIR TO LOWER PASSENGER SPACE.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 17 December 1996 Resolved
MARK EPRIB W/ VESSEL NAME.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Accommodation/Occupational Safety
Issued 17 December 1996 Resolved
MARK EXTERIOR OF ESCAPE HATCH.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 17 December 1996 Resolved
RENEW (7) ADULT SIZED PFD'S. UNTIL THIS REQUIREMENT IS MET, PASSENGER CARRIAGE IS REDUCED TO 57 PERSONS.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Navigation
Issued 29 January 1996 Resolved
REPAIR DETERIORATION OF STBD RUDDER.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Accommodation/Occupational Safety
Issued 29 January 1996 Resolved
CORRECT LEAK ON STBD 3" SEWAGE DISCHARGE VALVE.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Lifesaving
Issued 20 December 1995 Resolved
RENEW EPRIB BATTERY. VESSEL IS CONFINED TO RESTRICTED COASTWISE ROUTE OF WITHIN 20 MILES WITHIN A HARBOR OF SAFE REFUGE. _x001C_ _x001C_
Condition: Unknown
Due 20 January 1996
Resolved 8 January 1996
Lifesaving
Issued 20 December 1995 Resolved
RENEW WATERLIGHT ON 11 MAN LIFE FLOAT.
Condition: Unknown
Due 20 January 1996
Resolved 8 January 1996
Lifesaving
Issued 20 December 1995 Resolved
ARRANGE ALL LIFE FLOAT SEA PAINTERS TO ENSURE FREE RUN OUT OF LINE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 January 1996
Resolved 11 January 1996
Lifesaving
Issued 20 December 1995 Resolved
ATTACH PAINTER TO FORWARD 11 MAN LIFEFLOAT, INCLUDING WEAK LINK, TO VESSEL OR ATTACH TO FORWARD 15 MAN LIFEFLOAT. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 January 1996
Resolved 11 January 1996
Lifesaving
Issued 27 December 1994 Resolved
REPAIR/REPLACE FOUR ADULT TYPE 1 LIFE PRESERVERS.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Lifesaving
Issued 27 December 1994 Resolved
REPLACE FORWARD TOP LIFEFLOAT WATERLIGHT.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Lifesaving
Issued 19 February 1993 Resolved
PROVIDE ONE PORTABLE RESCUE LADDER/PLATFORM CAPABLE OF MOUNTING ON PORT OR STRB SIDES.
Condition: Unknown
Due 19 February 1993
Resolved 19 February 1993
Navigation
Issued 5 January 1993 Resolved
REPLACE BULB IN STERN LIGHT.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Lifesaving
Issued 5 January 1993 Resolved
STENCIL PFD STOWAGE CONTAINER ON TOP DECK.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Lifesaving
Issued 5 January 1993 Resolved
PROVIDE NEW BATTERY FOR VESSEL'S EPIRB.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Lifesaving
Issued 5 January 1993 Resolved
PROVIDE WATERLIGHT FOR FORWARD LIFEFLOAT.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Construction/Loadline
Issued 27 October 1992 Resolved
RENEW AFTERSTEERING BILGE PUMP OVERBOARD HOSE.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Construction/Loadline
Issued 27 October 1992 Resolved
RESEAL & BRACE INSTALLED REINFORCEMENT PLATE FOR CENTRAL BILGE PIPING AT BULKHEAD BETWEEN KLAZARETTE & ENGINEROOM.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Lifesaving
Issued 7 January 1992 Resolved
PROVIDE THREE ADULT TYPE 1 LIFE PRESERVERS.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Fire Fighting
Issued 7 January 1992 Resolved
INCREASE FIRE PUMP OUTPUT PRESSURE TO AN EFFECTIVE STREAM.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Engineering
Issued 22 January 1990 Resolved
RE-MARK FUEL OIL SHUT OFF REACH RODS.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Engineering
Issued 22 January 1990 Resolved
DEMONSTRATE OPERATION OF THE POWER BILGE PUMP.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Construction/Loadline
Issued 22 January 1990 Resolved
MAKE THE VESSEL AVAILABLE FOR AN INTERNAL EXAMINATION OF HULL WHILE WORKINGIN A SEAWAY.
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Fire Fighting
Issued 27 January 1987 Resolved
PROPERLY INSTALL PORTABLE FIRE EXTINGUISHER IN THE WHEELHOUSE.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Electrical
Issued 27 January 1987 Resolved
PROVIDE COVER ON ALL BATTERY BOX IN THE ENGINE ROOM.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Documentation
Issued 27 January 1987 Resolved
POST STABILITY LETTER IN THE WHEELHOUSE.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Lifesaving
Issued 27 January 1987 Resolved
PROPERLY STOW ALL CHILDS LIFEJACKET, STENCIL STOWAGE AREA WITH APPROPRIATE STENCIL.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Lifesaving
Issued 19 March 1986 Resolved
PROVIDE FOUR (4) PFD'S, TYPE I APPROVED TYPE AND IN GOOD CONDITION.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Lifesaving
Issued 26 March 1985 Resolved
4 ADULT PFD'S MISSING, 4 ADULT PFD'S AND ONE CHILD REJECTED DURING INSPECTION. REQUIRED REPLACEMENT OF THESE 9 PFD'S.
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985

Casualty record · 1

25 August 2020Routine · role: Involved in a Marine Casualty · activity 7042574
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.