Records from 1981 to 2019. Most recent: inspection, 3 December 2019.
Inspection history · 48
3 December 2019
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6867185
13 December 2016
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6057170
19 June 2012
Annual Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4329111
23 March 2010
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3700854
5 March 2009
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3427654
26 February 2008
Examination of Repairs · Hull Examination · Deficiency Check · Cargo Tank Internal · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3153629
27 June 2007
MTSA Verification · Re-Inspection · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977539
1 March 2007
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 3594858
6 April 2006
Ballast Water Examination · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2618047
12 April 2005
Examination of Repairs · Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2321243
24 March 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2336388
29 December 2004
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2265990
29 July 2004
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2148813
16 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971696
29 April 2003
Cargo Tank Internal · Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1782730
9 April 2003
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1772076
23 April 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1608250
8 May 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1063462
12 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 181189
6 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 4861
24 March 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455827
13 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 99898
11 May 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410103
21 September 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 117305
16 June 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459424
10 June 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454452
12 July 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 764816
12 June 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414656
19 May 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 203261
15 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 58610
15 April 1996
Permit to Proceed · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462495
16 June 1995
Hull Examination · COI Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380256
3 March 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 698353
3 March 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 708032
9 November 1994
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1178815
15 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 99720
15 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 109054
19 April 1994
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425457
9 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 121505
9 April 1994
Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1354655
7 April 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 698354
18 February 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444817
22 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330195
14 August 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273588
15 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287388
17 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973520
22 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277796
16 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975482
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 26 February 2008
Resolved
Provide 1 B-III Dry Chemical Fire Extinguisher for the carriage of Marine Portable Tanks.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2008
Resolution: 2 B-III fire extinguishers provided.
Electrical › Electrical Distribution System (service) › Cable
Issued 26 February 2008
Resolved
Remove un-authorized splice in main electrical cable to 440 volt panel in Lower Passageway.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2008
Resolution: Approved alternate splice with poured socket inside non-conductive housing.
Engineering › Fuel Oil Service System › Valve
Issued 26 February 2008
Resolved
Make Port Fuel Oil Daytank remote valve operational from the main deck.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2008
Resolution: Demonstrated operation of the remote valve.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 26 February 2008
Resolved
Provide application and scope of work for the Installation of New Engines and Reduction Gear.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 5 March 2009
Electrical › Electric Generation Source (service) › Generator
Issued 26 February 2008
Resolved
Provide application for the instalation of New Generators with Prime Movers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 5 March 2009
Stability › Weathertight Integrity › General
Issued 26 February 2008
Resolved
Install pins in all Port Light covers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2008
Resolution: Pins installed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 February 2008
Resolved
Pipe Washing Machine and AC drain into tank vice into bilge.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 5 March 2009
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 27 June 2007
Resolved
Tighten hand rail on bridge.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 28 June 2007
Engineering › Lubricating Oil Service System › Tank
Issued 27 June 2007
Resolved
Renew oil fill gasket on stbd eng.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 28 June 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 June 2007
Resolved
Remove water from batter boxes on bridge.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 28 June 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 June 2007
Resolved
Weld crack on stbd eng expansion tank.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2007
Resolved 28 June 2007
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 27 June 2007
Resolved
Repair stbd side fuel leak on fuel pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2007
Resolved 28 June 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 June 2007
Resolved
Repair multiple fuel and oil laks on pt and stbd engines.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2007
Resolved 28 June 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 June 2007
Resolved
Renew flex water hose on stbd eng outboard side and place double clamps on all sides.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 28 June 2007
Engineering › Lubricating Oil Service System › Flange
Issued 27 June 2007
Resolved
Repair front seal on port eng.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 28 June 2007
Construction/Loadline › Structures › Door
Issued 27 June 2007
Resolved
Replace multiple rubber gaskets on watertight doors and vents.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2007
Resolved 28 June 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 27 June 2007
Resolved
Adjust eng room door and renew cotter pins.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2007
Resolved 28 June 2007
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 27 June 2007
Resolved
Replace flame screens on waste oil tanks in eng room.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2007
Resolved 28 June 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 June 2007
Resolved
Renew leaking hose on port eng expansion tank.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 28 June 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 June 2007
Resolved
Repair port eng shut down on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2007
Resolved 28 June 2007
Communications › Internal Communications System › Sound-powered Telephone
Issued 29 July 2004
Resolved
Provide emergency power source to sound powered phone and light in engine room.
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 29 July 2004
Documentation › Certificates/Documents
Issued 9 July 2003
Resolved
Provide bridge to bridge certificate. LEGACY COMPONENT DESC: bridge to bridge
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 9 July 2003
Lifesaving › Line-Throwing Appliances › Lines
Issued 9 July 2003
Resolved
Provide 1 rocket impulse gun to bring the total to 4 complete rocket impulse guns.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 9 July 2003
Electrical › Electric Generation Source (service) › Switch
Issued 9 July 2003
Resolved
Repair port main shutdown switch.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 9 July 2003
Lifesaving › Hand Flares › Quantity
Issued 9 July 2003
Resolved
Provide 1 distress flare.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 16 July 2003
Engineering › Compressed Air System (start air) › Valve
Issued 9 July 2003
Resolved
Renew relief valves on both ships air receivers.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 9 July 2003
Communications › Visual Communication › Red Warning Signal
Issued 9 July 2003
Resolved
Label general alarm in engineroom.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 9 July 2003
Stability › Watertight Integrity
Issued 9 July 2003
Resolved
Renew watertight gasket on main deck hatch. LEGACY COMPONENT DESC: Emergency escape hatch
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2003
Resolved 9 July 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 9 July 2003
Resolved
Renew flame screen on port side liquid mud vent.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2003
Resolved 9 July 2003
Documentation › Logs/Records
Issued 23 April 2002
Resolved
PRE UNDERWAY CHECKS NOT BEING PERFORMED. LEGACY COMPONENT DESC: PRE UNDERWAY CHECKS
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 23 April 2002
Resolved
ALL REQUIRED NAV PUBLICATIONS NOT PROVIDED.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Engineering › Bilge Water Management System
Issued 23 April 2002
Resolved
INDIVIDUAL INDICATOR LIGHTS NOT PROVIDED FOR EACH HIGH BILGE SENSOR. LEGACY COMPONENT DESC: HIGH BILGE ALARM INDICATORS
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Lifesaving › Lifebuoys › Stowage
Issued 23 April 2002
Resolved
TWO RING BOUYS NOT ARRANGED FOR QUICK RELEASE.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Electrical › Lighting (service) › Lighting Fixture
Issued 23 April 2002
Resolved
TWO NAV LIGHTS NOT WORKING.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Construction/Loadline › Structures › Door
Issued 23 April 2002
Resolved
SEVERAL WATERTIGHT DOORS OUT OF ADJUSTMENT AND NOT STENCILED.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 23 April 2002
Resolved
ALL SMOKE DETECTORS NOT WORKING. LEGACY COMPONENT DESC: SMOKE DETECTORS.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 23 April 2002
Resolved
#2 LIQUID MUD PUMP REMOTE SHUT DOWN NOT WORKING.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Communications › Alarms/Indicators › General Alarm
Issued 23 April 2002
Resolved
GENERAL ALARM ROTATING BECON IN ENGINE ROOM NOT WORKING.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002
Electrical › Electric Generation Source (service)
Issued 23 April 2002
Resolved
GUARDS NOT INSTALLED AROUND ROTATING MACHINERY. LEGACY COMPONENT DESC: GUARDS
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2002
Resolved 23 April 2002