Records from 2016 to 2026. Most recent: inspection, 19 May 2026.
Documentation record
Registered dimensions (L × B × D)28.0 ft × 10.0 ft × 4.0 ft
Registered tonnagegross 7 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON · built 1999
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portTALKEETNA, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
19 May 2026
Simplified Stability Test · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8320123
21 May 2025
DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8117922
24 October 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8024043
5 June 2024
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7889639
22 May 2023
Drydock Exam · Annual Inspection · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7694114
23 May 2022
DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7443311
2 June 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7221463
20 April 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7174625
3 June 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6966399
22 May 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6839188
9 April 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6658533
23 August 2018
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6520870
12 June 2018
COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6504079
11 June 2018
Simplified Stability Test · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6441232
17 July 2017
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6212156
15 June 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5907665
18 May 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5845573
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 June 2026
Resolved
Prove proper operation of installed horn. Provide temporary hand airhorn until fixed.
Action required: 10 - Deficiency Rectified
Due 4 June 2026
Resolved 4 June 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 June 2026
Resolved
Make transom water tight on port side where wash down pump switch plate is located. Wash down pump running indicator light is missing and switch is no longer used.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2026
Resolved 5 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 May 2023
Resolved
Vessel is required to have a sound producing device. (whistle) Vessels installed sound producing device is non-functional. Provide proof of satisfactory operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2023
Resolution: Verified horn operational via movie from O/O.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 May 2022
Resolved
repair anchor light
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 22 June 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 May 2022
Resolved
Replace all combustible trash cans with non-combustible ones with no opens in the side or bottoms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 22 June 2022
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2022
Resolved
replace life ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 22 June 2022
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 June 2021
Resolved
Prove proper operation of the installed bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2021
Resolved 3 June 2021
Resolution: Repaired
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 June 2021
Resolved
Prove proper operation of the vapor detection system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2021
Resolved 3 June 2021
Resolution: New sensor installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 April 2021
Resolved
Make proper repairs to cracked frame, port side, second back from operators station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Resolution: Frame repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2020
Resolved
Prove proper operaton of stbd main engine prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2020
Resolved 4 June 2020
Resolution: Ring gear replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 June 2020
Resolved
Prove proper operation of the port running light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 7 July 2020
Resolution: Light repaird.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2020
Resolved
Mark childrens lifejackets location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 7 July 2020
Resolution: Storage marked.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 June 2018
Resolved
Correct name and port on the life ring.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 June 2018
Resolved 23 August 2018
Resolution: Life rings correctly marked.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 June 2018
Resolved
Properly mark life jackets with vessel name.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 June 2018
Resolved 23 August 2018
Resolution: Life jackets correctly marked.
Lifesaving › Lifejacket/PFD (General) › Size
Issued 12 June 2018
Resolved
Provide two child life jackets. No persons under 90 pounds may be carried until the correct life jackets are on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 June 2018
Resolved 23 August 2018
Resolution: Added life jackets as required.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 August 2017
Resolved
Conduct drills prior to carrying passengers in the presence of a marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2018
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 22 August 2017
Resolved
Conduct Fire Boy/Engine shutdowns Check, prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2018
Engineering › Non-conventional Propulsion/Steering › Shaft (jet)
Issued 22 August 2017
Resolved
Conduct function check of both Main Diesel Engines, Prior to carrying Passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2018
Communications › Radio Communications › EPIRB
Issued 16 June 2016
Resolved
Provide proof of EPIRB registration, Prior to carrying passengers
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2016
Resolved 28 June 2016
Resolution: Provided proof of up to date EPIRB registration.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2016
Resolved
Provide an approved first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 28 June 2016
Resolution: Provided an approved first aid kit.
Navigation › Piloting/Steering › Marine Charts
Issued 16 June 2016
Resolved
Provide updated charts, ligt list, Coast pilot and rules of the road.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 7 November 2016
Resolution: Administratively closed at Sector Anchorage