Records from 2021 to 2026. Most recent: inspection, 21 May 2026.
Documentation record
Registered dimensions (L × B × D)48.5 ft × 15.6 ft × 5.2 ft
Registered tonnagegross 30 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderR W GREEN BOAT YARD · DELTAVILLE, VA, UNITED STATES · built 1977
Hull materialWood
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEA ISLE CITY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 23 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 6
21 May 2026
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8367208
15 September 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8259541
28 April 2025
Internal Structural Exam · Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8120219
11 July 2024
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7955360
12 October 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7807552
16 August 2021
COI Inspection · Drydock Exam · Internal Structural Exam · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7290227
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 May 2026
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. The starboard side side planking just forward of the transom and below the deck was rotting approximately 1" into the side plank.
46 CFR 176.802
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2026
Resolution: Verified plank and fasteners replaced in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2026
Resolved
Where provisions are made for charging batteries, there must be natural or induced ventilation sufficient to dissipate the gases generated. Bow thruster batteries were emitting H2S into the operating station.
46 CFR 183.350
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2026
Resolution: Batteries replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2026
Resolved
Except as otherwise provided in this section, propulsion machinery installations must comply with the provisions of this part. Vessels drip less shaft seal was leaking.
46 CFR 182.310
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2026
Resolved 27 June 2026
Resolution: Rcvd video from owner with no leaks found
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 May 2026
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The #2 high water alarm was not showing a visual indication.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2026
Resolved 22 May 2026
Resolution: Light replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 May 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements. MI witnessed fuel collecting around fuel hose connection on port side fuel line.
46 CFR 182.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 29 May 2025
Resolution: Vessel had line tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 May 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements. MI witnessed raw water leak from main engine’s head gasket.
46 CFR 182.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Replaced gasket. No longer leaking.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 May 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements. Vessel had Parker FR 221 fire rated SAE J-942 fuel hose IWO the primary fuel filter but only one of the 4 fittings was a proper field fit end. The other three were hose clamped fittings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2025
Resolved 15 July 2026
Resolution: Verified fuel lines were installed with proper fitting.